{"title":"ABB Bailey Net 90 and Infi 90","description":"\u003cp data-start=\"2833\" data-end=\"2999\"\u003eThis collection includes ABB Bailey Net 90 and Infi 90 DCS components used for maintaining, upgrading, and supporting legacy industrial automation systems.\u003c\/p\u003e","products":[{"product_id":"tps02-abb-bailey-turbine-protection-slave-module-for-infi-90-symphony-plus","title":"TPS02 | ABB Bailey Turbine Protection Slave Module for INFI 90 \/ Symphony Plus","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTPS02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated turbine protection interface module developed by ABB Bailey for integration into INFI 90 and Symphony Plus distributed control systems. It functions as a safety-critical slave unit that directly interfaces with turbine emergency trip circuits, enabling ultra-fast response to overspeed or process fault conditions in steam and gas turbine applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike general-purpose I\/O modules, the TPS02 operates on a deterministic hardware-level logic path, bypassing standard system scan cycles to guarantee sub-millisecond trip activation when thresholds are exceeded. It continuously monitors redundant speed sensor inputs (typically from magnetic pickups or proximity probes) and hardwired trip signals, then drives high-integrity relay outputs that trigger solenoid valves or breaker coils in the turbine shutdown train.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB (formerly Bailey Controls)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTPS02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e: INFI 90, Symphony Plus (with appropriate expander hardware)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Turbine Protection System (TPS) Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Occupies one slot in a standard Module Mounting Unit (MMU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: +5 VDC via backplane (no external power required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e: Dedicated Slave Expander Bus (SEB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2–4 redundant overspeed detection inputs (accepts AC\/DC tachometer or pulse signals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple hardwired trip request inputs (voltage-free contacts or 24 VDC logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Solid-state drivers energizing fail-safe trip relays (external or internal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrip Logic\u003c\/strong\u003e: Hardwired or firmware-configurable voting logic (e.g., 2oo3 overspeed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 °C to +70 °C (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Features\u003c\/strong\u003e: Built-in self-test (BIT), watchdog timer, and status reporting to master controller via SEB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Isolation\u003c\/strong\u003e: Optical or transformer-based isolation between logic and field-side trip circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: Designed to meet IEC 61508 SIL 2\/3 requirements in properly architected systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency overspeed protection in fossil, nuclear, and combined-cycle power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with mechanical-hydraulic trip systems requiring electronic backup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit projects upgrading legacy turbine controls to digital DCS platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can the TPS02 operate independently of the Symphony Plus controller?\u003c\/strong\u003e\u003cbr\u003eA: No—it requires a master module (such as the TPS01) on the same expander bus to configure logic and monitor health, though trip execution is hardware-accelerated and does not rely on host CPU cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support triple-modular redundancy (TMR)?\u003c\/strong\u003e\u003cbr\u003eA: The TPS02 itself is a single-channel module, but multiple units can be deployed in redundant configurations (e.g., 2oo3 voting across three TPS02 modules) when paired with appropriate input\/output hardware and logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is diagnostics information accessed?\u003c\/strong\u003e\u003cbr\u003eA: Status bits (OK, fault, trip active) are communicated over the Slave Expander Bus to the master protection module, which forwards them to the DCS operator station for alarm annunciation and logging.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52513616527544,"sku":"TPS02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TPS02____1.jpg?v=1769768630"},{"product_id":"abb-bailey-imfcs01-frequency-counter-slave-module-for-infi-90-symphony-plus","title":"ABB Bailey IMFCS01 Frequency Counter Slave Module for INFI 90 \/ Symphony Plus","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIMFCS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated frequency measurement slave module developed by ABB Bailey for use in INFI 90 and Symphony Plus distributed control systems. It provides high-resolution, real-time acquisition of periodic signals from field instruments—such as magnetic pickups on turbine shafts, vortex flow meters, or encoder outputs—and converts them into precise digital frequency values for process control and monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike general-purpose analog inputs, the IMFCS01 employs hardware-timed counters with adaptive signal conditioning to accurately capture frequencies across a wide dynamic range, even in electrically noisy environments typical of power generation and heavy industry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB (formerly Bailey Controls)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIMFCS01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e: INFI 90, Symphony Plus (with Harmony or Master controller support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Frequency Counter Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Single slot in standard Module Mounting Unit (MMU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: +5 VDC via system backplane (no external wiring required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e: Internal Slave Expander Bus (SEB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 4 independent frequency input channels (typical configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSine wave: 0.2 Vrms to 10 Vrms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSquare\/pulse wave: 2 V to 24 VDC (TTL\/CMOS compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero-crossing AC signals from passive magnetic pickups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Measurement Range\u003c\/strong\u003e: 0.1 Hz to 10 kHz (configurable per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: Up to 0.01 Hz (depending on gate time and firmware settings)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: Onboard Schmitt trigger, programmable hysteresis, and low-pass filtering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Immunity\u003c\/strong\u003e: Differential inputs with common-mode rejection; opto-isolation optional in some variants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Continuous self-check of input circuitry, counter integrity, and bus communication; front-panel LED status indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: Configurable (typically 100 ms to 1 s per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine and motor speed monitoring (RPM calculation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow rate derivation from pulse-output flow meters (e.g., turbine or vortex types)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConveyor belt speed verification in material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSynchronization of rotating equipment in combined-cycle or co-generation plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can the IMFCS01 be used without a master module?\u003c\/strong\u003e\u003cbr\u003eA: No—it operates as a slave device and requires a master controller (e.g., HMEI01 or TPS01) on the same expander bus to configure parameters and read data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support fail-safe behavior on signal loss?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Each channel can be configured to output a defined “bad” value or trigger an alarm if input signal amplitude drops below threshold or frequency stalls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it differ from the IMASI01 analog input module?\u003c\/strong\u003e\u003cbr\u003eA: The IMASI01 handles continuous voltage\/current signals, while the IMFCS01 is optimized for discrete, time-based frequency inputs. They serve complementary roles—IMFCS01 for speed\/flow pulses, IMASI01 for pressure, temperature, or position.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52513629307064,"sku":"IMFCS01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMFCS01.jpg?v=1769768922"},{"product_id":"abb-ntdi01-digital-i-o-termination-unit-symphony-harmony-infi-90","title":"ABB NTDI01 Digital I\/O Termination Unit | Symphony Harmony \u0026 INFI 90","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eNTDI01\u003c\/strong\u003e Digital I\/O Termination Unit is a compact module designed for installation in control cabinets, providing reliable signal termination for ABB Symphony Harmony and INFI 90 systems. With a single channel configuration and 24 VDC input\/output voltage, the \u003cstrong\u003eNTDI01\u003c\/strong\u003e ensures stable operation in industrial environments. Its lightweight design and small footprint make it suitable for space-constrained applications while maintaining compatibility with ABB’s control architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eNTDI01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital I\/O Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput\/Output Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e As per ABB specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 48.3 × 25.4 × 10.2 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.32 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e ABB Symphony Harmony, ABB INFI 90\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Lithuania (LT), India (IN)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for easy cabinet installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSingle-channel termination for precise signal handling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with ABB Symphony Harmony and INFI 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight construction for simplified integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for stable 24 VDC operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl cabinet installations requiring digital I\/O termination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB Symphony Harmony and INFI 90 system expansions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial environments with limited installation space\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What voltage does the NTDI01 operate on?\u003c\/strong\u003e  A: 24 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which ABB systems are supported?\u003c\/strong\u003e  A: Symphony Harmony and INFI 90.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels does this unit provide?\u003c\/strong\u003e  A: One channel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the NTDI01?\u003c\/strong\u003e  A: Approximately 0.32 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTDI01:\u003c\/strong\u003e Single-channel termination, compact design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTDI02:\u003c\/strong\u003e Multi-channel variant for higher density applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTDI03:\u003c\/strong\u003e Enhanced termination features with extended compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521181413560,"sku":"NTDI01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTDI01.jpg?v=1770024426"},{"product_id":"abb-ntr002-a-temperature-sensor-interface-module-rtd-thermocouple","title":"ABB NTR002-A Temperature Sensor Interface Module | RTD \u0026 Thermocouple","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eNTR002-A\u003c\/strong\u003e Temperature Sensor Interface Module is designed to connect RTDs and thermocouples directly to ABB’s distributed control systems, enabling precise and stable temperature measurement across a wide operating range. With dual sensor channels, high-resolution conversion, and robust environmental tolerance, the \u003cstrong\u003eNTR002-A\u003c\/strong\u003e ensures accurate data acquisition for critical industrial processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eNTR002-A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Temperature Sensor Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Sensor Types:\u003c\/strong\u003e RTD, Thermocouple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e –200 °C to +1800 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit analog-to-digital conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLength: 100 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 50 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 30 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +50 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Tolerance:\u003c\/strong\u003e 10%–90% RH, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual-channel input for flexible sensor integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh accuracy and resolution for precise monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide measurement range suitable for extreme industrial conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for easy installation in control cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with ABB distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess industries requiring precise temperature monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation and chemical plants with high-temperature operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems integrating RTDs and thermocouples\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironments demanding reliable sensor-to-system connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What sensor types are supported by the NTR002-A?\u003c\/strong\u003e  A: RTDs and thermocouples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels are available?\u003c\/strong\u003e  A: Two independent sensor channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the accuracy of this module?\u003c\/strong\u003e  A: ±0.1 °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it operate in high humidity environments?\u003c\/strong\u003e  A: Yes, up to 90% RH non-condensing.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521213198520,"sku":"NTR002-A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTR002-A1__1.jpg?v=1770024803"},{"product_id":"mfec12-abb-analog-input-module-15-channel","title":"MFEC12 | ABB Analog Input Module | 15-Channel","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eIMFEC12\u003c\/strong\u003e Analog Input Module is a dedicated interface unit designed for use with multifunction processors (MFP) and multifunction controllers (MFC). Supporting up to 15 analog input channels, the \u003cstrong\u003eIMFEC12\u003c\/strong\u003e is optimized for integration with conventional transmitters such as BC, EQ, and PT, ensuring accurate and stable signal acquisition in industrial control systems. Its robust construction and compact design make it suitable for demanding environments where reliability and precision are critical.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eIMFEC12\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 15\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Systems:\u003c\/strong\u003e Multifunction Processor (MFP), Multifunction Controller (MFC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Inputs:\u003c\/strong\u003e Conventional transmitters (BC, EQ, PT) and standard analog signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.476 kg (net), 1 kg total\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePackaging Dimension Weight:\u003c\/strong\u003e 3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e15-channel analog input capability for versatile signal handling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeamless integration with ABB multifunction processors and controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatibility with conventional transmitter types\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact and durable construction for industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial process control systems requiring multiple analog inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration with ABB Symphony Harmony or INFI 90 architectures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring of conventional transmitters in chemical, power, and manufacturing plants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels does the IMFEC12 provide?\u003c\/strong\u003e  A: 15 analog input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which ABB modules is the IMFEC12 compatible with?\u003c\/strong\u003e  A: It connects only to multifunction processors (MFP) or multifunction controllers (MFC).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What types of transmitters can be used with this module?\u003c\/strong\u003e  A: Conventional transmitters such as BC, EQ, and PT.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the net weight of the IMFEC12?\u003c\/strong\u003e  A: Approximately 1 kg including packaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIMFEC12:\u003c\/strong\u003e 15-channel analog input, designed for MFP\/MFC modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIMFEC11:\u003c\/strong\u003e Lower channel density, suited for smaller systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIMFEC13:\u003c\/strong\u003e Expanded input capability with enhanced diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521241215160,"sku":"IMFEC12","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMFEC12.jpg?v=1770025117"},{"product_id":"abb-imdso14-digital-slave-output-module-16-channel","title":"ABB IMDSO14 Digital Slave Output Module | 16-Channel","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eIMDSO14\u003c\/strong\u003e Digital Slave Output Module is a compact and reliable unit designed for industrial automation systems. It provides 16 digital output channels with robust isolation and electromagnetic compatibility, ensuring stable performance in demanding environments. Operating on a 5 VDC supply, the \u003cstrong\u003eIMDSO14\u003c\/strong\u003e is engineered to deliver consistent output control for a wide range of industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eIMDSO14\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Slave Output Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage: 5 VDC (±5%)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTypical Current: 275 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Current: 370 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLogic Dissipation: 1.375 W (typical), 1.850 W (maximum)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNumber of Channels: 16 digital outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLoad Voltage: 24 VDC, 48 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Load Current: 250 mA (24 VDC), 125 mA (48 VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff-State Leakage Current: ≤10 μA at 70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOn-State Voltage Drop: ≤2 V at 70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption per Output:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAt 24 VDC: 150 mA typical, 250 mA maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAt 48 VDC: 75 mA typical, 125 mA maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e Overvoltage category II, IEC 1010-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e16-channel digital output capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh isolation and EMC compliance for industrial reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for cabinet integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStable operation across multiple load voltages\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring multiple digital outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl cabinets with space constraints\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplications needing reliable signal isolation and low leakage current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many digital outputs does the IMDSO14 provide?\u003c\/strong\u003e  A: 16 channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What supply voltage is required?\u003c\/strong\u003e  A: 5 VDC (±5%).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum load current supported?\u003c\/strong\u003e  A: 250 mA at 24 VDC, 125 mA at 48 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module comply with IEC standards?\u003c\/strong\u003e  A: Yes, it meets IEC 1010-1 overvoltage category II.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIMDSO14:\u003c\/strong\u003e 16-channel digital output, 5 VDC supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIMDSO12:\u003c\/strong\u003e Lower channel density, suited for smaller systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIMDSO16:\u003c\/strong\u003e Expanded output capability with enhanced current handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521262547128,"sku":"IMDSO14","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMDSO14.jpg?v=1770025367"},{"product_id":"ntmp01-abb-bailey-multi-function-processor-termination-unit","title":"NTMP01 | ABB Bailey Multi-Function Processor Termination Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eNTMP01\u003c\/strong\u003e Multi-Function Processor Termination Unit is designed to provide reliable connectivity and signal termination for ABB’s distributed control systems. This module supports multiple processor types including BRC, MFP, IET, ICT, and NKTU, ensuring flexible integration across system architectures. With dual RS-232-C ports or a combination of RS-232-C and RS-485, the \u003cstrong\u003eNTMP01\u003c\/strong\u003e enables stable communication links for control stations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts construction meets industrial requirements for durability, with PVC and non-PVC cable insulation options rated for high temperature operation. The unit requires no active cooling when installed in Bailey cabinets and is engineered to operate within defined environmental limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eNTMP01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Multi-Function Processor Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules:\u003c\/strong\u003e BRC, MFP, IET, ICT, NKTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo RS-232-C serial ports, or\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne RS-232-C port and one RS-485 port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne control station serial link\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCable Insulation Ratings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePVC (UL CL2): 80 °C at 300 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-PVC (UL PLTC): 90 °C at 300 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectromagnetic\/Radio Frequency Interference:\u003c\/strong\u003e Cabinet doors must remain closed; avoid communication equipment within 2 meters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCooling Requirements:\u003c\/strong\u003e None required when installed in Bailey cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to 70 °C (32 °F to 158 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5%–90% up to 70 °C, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Compact form factor (noted as 2.5 kg + 1 kg packaging weight; corrected net weight 0.3 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible communication options with RS-232-C and RS-485 support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for ABB Bailey distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo cooling required under normal operating conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRugged design with high-temperature cable insulation ratings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact and lightweight for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration into ABB Symphony Harmony and INFI 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial control cabinets requiring processor termination units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironments with strict EMI\/RFI management requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which ABB modules are supported by the NTMP01?\u003c\/strong\u003e  A: BRC, MFP, IET, ICT, and NKTU.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication interfaces are available?\u003c\/strong\u003e  A: Two RS-232-C ports, or one RS-232-C and one RS-485 port.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the NTMP01 require cooling?\u003c\/strong\u003e  A: No, cooling is not necessary when installed in Bailey cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e  A: 0 °C to 70 °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTMP01:\u003c\/strong\u003e Standard termination unit with RS-232-C\/RS-485 support.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTMP02:\u003c\/strong\u003e Enhanced communication options with additional redundancy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTMP03:\u003c\/strong\u003e Higher channel density for expanded system integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521278668984,"sku":"NTMP01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTMP01.jpg?v=1770025628"},{"product_id":"abb-innis01-network-interface-slave-module-infi-90","title":"ABB INNIS01 Network Interface Slave Module | INFI 90","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eINNIS01\u003c\/strong\u003e Network Interface Slave Module is a communication interface unit designed for ABB’s INFI 90 OPEN control systems. It provides reliable connectivity between controllers and distributed nodes, supporting high-speed data transfer rates and flexible integration with multiple interface types. With robust memory capacity and efficient power requirements, the \u003cstrong\u003eINNIS01\u003c\/strong\u003e ensures stable operation in complex industrial networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eINNIS01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Network Interface Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRAM: 208 kB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eROM: 64 kB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e+5 VDC: 900 mA (4.50 W nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e+15 VDC: 5 mA (0.08 W nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e–15 VDC: 200 mA (3.00 W nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Capability:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Nodes in System: 62,500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNodes per Loop: 250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Interfaces:\u003c\/strong\u003e PCU, MCS, OIS, ICI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Rates:\u003c\/strong\u003e 10 Mbaud or 2 Mbaud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Occupies one slot in INFI 90 OPEN module mounting unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.93 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-speed communication with selectable baud rates\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge system capacity supporting up to 62,500 nodes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible interface compatibility for diverse system configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for easy integration into INFI 90 OPEN racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStable performance with efficient power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems requiring reliable communication modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation networks with large node capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB INFI 90 OPEN system expansions and upgrades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication speeds does the INNIS01 support?\u003c\/strong\u003e  A: 10 Mbaud and 2 Mbaud.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many nodes can be supported in a system?\u003c\/strong\u003e  A: Up to 62,500 nodes, with 250 nodes per loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which ABB interfaces are compatible?\u003c\/strong\u003e  A: PCU, MCS, OIS, and ICI interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is the module installed?\u003c\/strong\u003e  A: It occupies one slot in a standard INFI 90 OPEN mounting unit.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521294233784,"sku":"INNIS01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INNIS01.jpg?v=1770025830"},{"product_id":"abb-ntcl01-infi-net-communication-link-termination-unit","title":"ABB NTCL01 INFI-Net Communication Link Termination Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eNTCL01\u003c\/strong\u003e INFI-Net Communication Link Termination Unit is engineered to provide reliable signal termination and communication support within ABB’s INFI-Net network. Designed for use with NIS and NKLS modules, the \u003cstrong\u003eNTCL01\u003c\/strong\u003e ensures stable data transfer and system integrity in distributed control environments. Its compact dimensions allow easy installation in control cabinets while maintaining robust performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eNTCL01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e INFI-Net Communication Link Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules:\u003c\/strong\u003e NIS, NKLS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Facilitates communication over INFI-Net network\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth\/Length: 96.52 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 236.22 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 220.98 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides secure termination for INFI-Net communication links\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatibility with NIS and NKLS modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact form factor for efficient cabinet integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures reliable communication across distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB INFI-Net distributed control system installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation networks requiring stable communication links\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl cabinets with NIS and NKLS module integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which modules are supported by the NTCL01?\u003c\/strong\u003e  A: It is designed for use with NIS and NKLS modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the NTCL01?\u003c\/strong\u003e  A: It provides termination and facilitates communication over the INFI-Net network.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the NTCL01 be installed in standard control cabinets?\u003c\/strong\u003e  A: Yes, its compact dimensions allow easy integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTCL01:\u003c\/strong\u003e Standard termination unit for NIS\/NKLS modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTCL02:\u003c\/strong\u003e Enhanced termination with extended communication diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTCL03:\u003c\/strong\u003e Multi-link termination for larger system configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521309438136,"sku":"NTCL01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTCL01.jpg?v=1770026084"},{"product_id":"abb-bailey-ntai06-analog-input-termination-unit-plc-module","title":"ABB Bailey NTAI06 | Analog Input Termination Unit | PLC Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eNTAI06\u003c\/strong\u003e Analog Input Termination Unit is a robust module engineered for precise signal termination in PLC-based automation systems. Designed to handle analog input channels efficiently, it ensures reliable connectivity and streamlined integration within control racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eNTAI06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs \/ Machine Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSubcategory:\u003c\/strong\u003e PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth \/ Length: 96.52 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 236.22 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 218.44 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.635 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e WEEE Category 5 (Small Equipment, no external dimension exceeding 50 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Requirement:\u003c\/strong\u003e None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring analog signal termination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePLC racks in manufacturing and process control environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical monitoring systems with multiple analog input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl panels where compact and reliable termination units are essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the function of the ABB Bailey NTAI06 unit?\u003c\/strong\u003e  A: It provides termination for analog input signals in PLC systems, ensuring accurate signal transmission and system stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the unit require batteries?\u003c\/strong\u003e  A: No, the NTAI06 does not require any batteries for operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the module compliant with WEEE regulations?\u003c\/strong\u003e  A: Yes, it falls under WEEE Category 5 for small equipment.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848546644152,"sku":"NTAI06","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTAI06_5a3c34b7-35e8-45a6-bc6e-36f34a726f60.jpg?v=1770888274"},{"product_id":"imdsi14-abb-bailey-16-point-digital-input-module-slave-input-unit","title":"IMDSI14 | ABB Bailey 16-Point Digital Input Module | Slave Input Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMDSI14\u003c\/strong\u003e Digital Slave Input Module is a high-performance unit designed to provide reliable digital input functionality for ABB’s Infi 90 and Net 90 control systems. With 16 dedicated input channels, this module ensures accurate signal acquisition and seamless integration into industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIMDSI14\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Code \/ Order No.:\u003c\/strong\u003e \u003cstrong\u003eIMDSI14\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Slave Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16 digital inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 48 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 7.0 in (17.8 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 12.5 in (31.8 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 1.5 in (3.8 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg (8.0 oz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e ABB Bailey Infi 90 and Net 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Compact rack-mounted design for efficient space utilization\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration into ABB Bailey Infi 90 and Net 90 distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring multiple digital input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMachine control environments with high reliability demands\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess monitoring systems where precise digital signal acquisition is critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many input channels does the IMDSI14 provide?\u003c\/strong\u003e  A: The module supports 16 digital input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What voltage level is supported?\u003c\/strong\u003e  A: The IMDSI14 is designed for 48 VDC digital input signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this module compatible with ABB Bailey Infi 90 systems?\u003c\/strong\u003e  A: Yes, it is specifically designed for ABB Bailey Infi 90 and Net 90 systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the module?\u003c\/strong\u003e  A: The unit weighs approximately 0.2 kg (8.0 oz).\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848588849336,"sku":"IMDSI14","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMDSI14_ae45b373-eae3-4c19-9d38-08da092261f0.jpg?v=1770888332"},{"product_id":"imhss03-abb-bailey-symphony-hydraulic-servo-module-turbine-control-unit","title":"IMHSS03 | ABB Bailey Symphony Hydraulic Servo Module | Turbine Control Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMHSS03\u003c\/strong\u003e Hydraulic Servo Module is a specialized control unit engineered for turbine regulation within INFI 90 and Symphony Harmony platforms. It serves as the interface between processor outputs and hydraulic actuators, enabling precise positioning of turbine throttle valves through servo valves or I\/H converters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIMHSS03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Hydraulic Servo Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e INFI 90 \/ Symphony Harmony Rack I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Interface:\u003c\/strong\u003e Compatible with IMMFP01, IMMFP02, and IMMFP03 Multi-Function Processor Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Handling:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccepts position demand signals from MFP processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDrives servo valve currents for turbine throttle valve actuation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcesses LVDT feedback for closed-loop position control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBus Communication:\u003c\/strong\u003e Integrated with INFI 90 bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOnboard CPU Functions:\u003c\/strong\u003e Gain tuning, fault buffering, and loop closure management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 120 × 80 × 60 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e Switzerland\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTurbine control systems requiring precise hydraulic actuation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation plants using ABB Bailey INFI 90 or Symphony Harmony platforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironments where closed-loop feedback and high accuracy are critical for turbine throttle valve regulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary role of the IMHSS03 module?\u003c\/strong\u003e  A: It bridges processor outputs to hydraulic actuators, ensuring accurate turbine throttle valve positioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which processor modules are supported?\u003c\/strong\u003e  A: The IMHSS03 works with IMMFP01, IMMFP02, and IMMFP03 multi-function processor modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module provide closed-loop control?\u003c\/strong\u003e  A: Yes, it processes LVDT feedback to maintain precise closed-loop position control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Where is the IMHSS03 manufactured?\u003c\/strong\u003e  A: The unit is produced in Switzerland.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848597532856,"sku":"IMHSS03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMHSS03.jpg?v=1770888474"},{"product_id":"abb-imasi23-analog-input-module-plc-signal-processing-unit","title":"ABB IMASI23 | Analog Input Module | PLC Signal Processing Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eIMASI23\u003c\/strong\u003e Analog Input Module is a precision-engineered unit designed for advanced signal acquisition and processing in PLC systems. It provides reliable analog input handling with integrated diagnostic features, ensuring accurate conversion and monitoring of signals in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product No.:\u003c\/strong\u003e \u003cstrong\u003eIMASI23\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChannel and cold junction reference switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProgramming of A\/D converters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReading A\/D converters with correction factor application\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterface to switches and diagnostic LEDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackground integrity checking for system reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRead\/write operations for signal management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Compact rack-mounted design for PLC integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Built-in LED indicators for fault detection and system monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring precise analog signal acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePLC-based process control environments with multiple analog channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems where diagnostic monitoring and integrity checking are critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturing plants requiring reliable analog-to-digital conversion modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary role of the IMASI23 module?\u003c\/strong\u003e  A: It handles analog input signals, performs A\/D conversion, and applies correction factors for accurate data processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module include diagnostic features?\u003c\/strong\u003e  A: Yes, it integrates switches and LEDs for diagnostic mode and background integrity checking.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the IMASI23?\u003c\/strong\u003e  A: The unit weighs approximately 0.4 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the IMASI23 compatible with ABB PLC racks?\u003c\/strong\u003e  A: Yes, it is designed for seamless integration into ABB PLC systems\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848752361656,"sku":"IMASI23","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMASI23.jpg?v=1770888699"},{"product_id":"imdsm04-abb-bailey-pulse-input-slave-module-plc-signal-interface","title":"IMDSM04 | ABB Bailey | Pulse Input Slave Module | PLC Signal Interface","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMDSM04\u003c\/strong\u003e Pulse Input Slave Module is designed to capture pulse signals from external devices and convert them into digital inputs for processing within Bailey control systems. This module ensures accurate signal acquisition and reliable communication with PLCs, making it suitable for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eIMDSM04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Pulse Input Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e +5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 1.5 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Voltage:\u003c\/strong\u003e +24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Current:\u003c\/strong\u003e 80 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth \/ Length: 71.12 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 271.78 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 358.14 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e Compact and robust construction for rack-mounted PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Fully supported within Bailey control system architectures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePulse signal acquisition from sensors, counters, and external devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration into Bailey PLC racks for process monitoring and control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring reliable pulse-to-digital conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironments where compact modules with stable performance are essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the IMDSM04?\u003c\/strong\u003e  A: It receives pulse inputs from external devices and converts them into digital signals for PLC processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What voltage levels does the module operate on?\u003c\/strong\u003e  A: The IMDSM04 operates with a +5 VDC input and provides a +24 VDC secondary output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the module compatible with Bailey control systems?\u003c\/strong\u003e  A: Yes, it is specifically designed for Bailey control system integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the IMDSM04?\u003c\/strong\u003e  A: The unit weighs approximately 0.3 kg.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848761536696,"sku":"IMDSM04","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMDSM04.jpg?v=1770888898"},{"product_id":"abb-ntai05-analog-input-termination-unit-16-channel-high-level-module","title":"ABB NTAI05 | Analog Input Termination Unit | 16-Channel High-Level Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eNTAI05\u003c\/strong\u003e Analog Input Termination Unit is a high-level signal interface module designed to support 16 analog input channels. Built for integration with FEC and NKTU modules, it ensures reliable signal termination and stable performance in ABB automation systems. Its compact design and robust construction make it suitable for demanding industrial environments where precision and durability are essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Type Designation:\u003c\/strong\u003e \u003cstrong\u003eNTAI05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID:\u003c\/strong\u003e \u003cstrong\u003eNTAI05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Description:\u003c\/strong\u003e High-Level Analog Input Termination, 16 Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Designed for use with FEC and NKTU modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHS Code:\u003c\/strong\u003e 853710 – Electrical control panels and connectors (≤1000 V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCustoms Tariff Number:\u003c\/strong\u003e 85371091\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth \/ Length: 78.74 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 215.9 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 233.68 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.552 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Rack-mounted termination unit for PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal interfacing in ABB automation platforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial control systems requiring reliable analog input termination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse with FEC and NKTU modules in distributed control environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturing plants and process industries where precise analog input handling is critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels does the NTAI05 support?\u003c\/strong\u003e  A: The module provides 16 high-level analog input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which ABB modules is the NTAI05 designed to work with?\u003c\/strong\u003e  A: It is specifically intended for use with FEC and NKTU modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the unit?\u003c\/strong\u003e  A: The NTAI05 weighs approximately 0.552 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the module compliant with international tariff classifications?\u003c\/strong\u003e  A: Yes, it is classified under HS Code 853710 and Customs Tariff Number 85371091.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848797286584,"sku":"NTAI05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTAI05.jpg?v=1770889096"},{"product_id":"abb-ntdi21a-termination-unit-compact-plc-module","title":"ABB NTDI21A | Termination Unit | Compact PLC Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eNTDI21A\u003c\/strong\u003e Termination Unit is a precision-engineered module designed to provide reliable signal termination within ABB automation systems. Manufactured in Switzerland, this unit combines compact dimensions with robust construction, ensuring dependable performance in industrial control environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Type Designation:\u003c\/strong\u003e \u003cstrong\u003eNTDI21A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 18 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 17.6 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.36 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Compact design for rack-mounted PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Provides termination interface for signal connections in ABB control platforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal termination in ABB PLC racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring compact termination modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl environments where space efficiency and reliability are critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the NTDI21A?\u003c\/strong\u003e  A: It serves as a termination interface for signal connections in ABB automation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Where is the NTDI21A manufactured?\u003c\/strong\u003e  A: The unit is produced in Switzerland.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the dimensions of the module?\u003c\/strong\u003e  A: The NTDI21A measures 18 cm × 17.6 cm × 2 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How much does the unit weigh?\u003c\/strong\u003e  A: The module weighs approximately 0.36 kg.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848799383736,"sku":"NTDI21-A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTDI21-A.jpg?v=1770889260"},{"product_id":"nths03-abb-bailey-hydraulic-servo-termination-unit-infi-90-module","title":"NTHS03 | ABB Bailey Hydraulic Servo Termination Unit Infi 90 Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eNTHS03\u003c\/strong\u003e Hydraulic Servo Termination Unit is designed for seamless integration with hydraulic servo modules in the Infi 90 control system. This termination unit provides reliable interfacing for modules such as IM\/SPHSS03, IM\/SPHSS04, IM\/SPHSS05, and IM\/SPHSS13, ensuring stable connections and dependable performance in turbine and process control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Type Designation:\u003c\/strong\u003e \u003cstrong\u003eNTHS03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID:\u003c\/strong\u003e \u003cstrong\u003eNTHS03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Hydraulic Servo Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Description:\u003c\/strong\u003e Hydraulic Servo TU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for IM\/SPHSS03, IM\/SPHSS04, IM\/SPHSS05, IM\/SPHSS13 modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth \/ Length: 25.4 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 195.58 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 195.58 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e WEEE Category 5 (Small Equipment, no external dimension exceeding 50 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Requirement:\u003c\/strong\u003e None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination interface for hydraulic servo modules in ABB Bailey Infi 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTurbine control environments requiring precise hydraulic actuation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems where reliable termination units are essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which modules are supported by the NTHS03?\u003c\/strong\u003e  A: It is compatible with IM\/SPHSS03, IM\/SPHSS04, IM\/SPHSS05, and IM\/SPHSS13.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the NTHS03 require batteries?\u003c\/strong\u003e  A: No, the unit does not require any batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the environmental classification of this unit?\u003c\/strong\u003e  A: It falls under WEEE Category 5 for small equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the dimensions of the NTHS03?\u003c\/strong\u003e  A: The unit measures 25.4 mm × 195.58 mm × 195.58 mm.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848801972408,"sku":"NTHS03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTHS03.jpg?v=1770889433"},{"product_id":"abb-bailey-ntro12-a-analog-input-terminal-board-12-channel-signal-module","title":"ABB Bailey NTRO12-A | Analog Input Terminal Board | 12-Channel Signal Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eNTRO12-A\u003c\/strong\u003e Analog Input Terminal Board is a high-precision interface module designed for industrial automation and data acquisition systems. Supporting both voltage and current inputs, it ensures accurate signal conversion and reliable integration into control environments. With advanced isolation and compliance to international standards, this board is engineered for robust performance in demanding applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eNTRO12-A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Terminal Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Types:\u003c\/strong\u003e Analog voltage or current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Range:\u003c\/strong\u003e -10 V to +10 V or 4 mA to 20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 2 MΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 250 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -55 °C to +85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Tolerance:\u003c\/strong\u003e 0% to 95% RH (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 140 mm × 60 mm × 20 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Polycarbonate housing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e DIN rail or panel mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e 2 kV between channels and ground\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEMI\/RFI Protection:\u003c\/strong\u003e IEC 61000-4-3 and IEC 61000-4-6 compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial control systems requiring precise analog signal acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomation platforms with multiple analog input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData acquisition systems where accuracy and resolution are critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironments with high EMI\/RFI exposure requiring protected modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels does the NTRO12-A support?\u003c\/strong\u003e  A: It provides 12 analog input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What input ranges are supported?\u003c\/strong\u003e  A: The module supports -10 V to +10 V voltage signals and 4 mA to 20 mA current signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the NTRO12-A include isolation?\u003c\/strong\u003e  A: Yes, it offers 2 kV isolation between channels and ground.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848803709112,"sku":"NTR012","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTR012-A.jpg?v=1770889645"},{"product_id":"innpm22-abb-bailey-infinet-network-processor-module-symphony-plus","title":"INNPM22 | ABB Bailey InfiNet Network Processor Module | Symphony Plus","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eINNPM22\u003c\/strong\u003e Network Processor Module is a communication interface designed for Symphony Plus and Infi 90 systems. It provides supervised and redundant power input capability, ensuring reliable operation in distributed control environments. Compatible with HR Series Harmony Rack hardware, the module enables efficient data exchange across InfiNet networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eINNPM22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Symphony Plus, HR Series Harmony Rack hardware\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNetwork processor for InfiNet communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupervised power inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundant power supply capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth \/ Length: 73.66 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 360.68 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 279.4 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWEEE Category 5 (Small Equipment, no external dimension exceeding 50 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Information:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNumber of Batteries: 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType: Lithium button cell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeight: 5 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication backbone for ABB Symphony Plus distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration into HR Series Harmony Rack hardware for process automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial environments requiring redundant and supervised power inputs for reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What systems are supported by the INNPM22?\u003c\/strong\u003e  A: It is compatible with Symphony Plus and HR Series Harmony Rack hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module support redundant power supplies?\u003c\/strong\u003e  A: Yes, it is designed with redundant power input capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of battery is included?\u003c\/strong\u003e  A: A lithium button cell battery weighing 5 g.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the INNPM22?\u003c\/strong\u003e  A: The module weighs approximately 0.35 kg.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848805413048,"sku":"INNPM22","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INNPM221.jpg?v=1770889819"},{"product_id":"abb-immpi01-multi-function-processor-interface-communication-module","title":"ABB IMMPI01 | Multi-Function Processor Interface | Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eIMMPI01\u003c\/strong\u003e Multi-Function Processor Interface is a communication module designed to manage data exchange between host computers and the \u003cstrong\u003eINICT03\u003c\/strong\u003e module in Bailey control systems. Supporting both SCSI and RS-232-C interfaces, it provides flexible connectivity options and can operate as either data communication equipment (DCE) or data terminal equipment (DTE).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis single-slot printed circuit board integrates microprocessor-based communication circuitry, ensuring reliable performance in industrial automation environments. The module includes multiple edge connectors for external signals and power, enabling seamless integration with termination units and associated hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product No.:\u003c\/strong\u003e \u003cstrong\u003eIMMPI01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Multi-Function Processor Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTwo RS-232-C ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne SCSI port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e +5 VDC at 415 mA (2.08 W typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eP1: Common and +5 VDC power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eP2: Not used\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eP3: Cable connection to NTMP01 termination unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eP6: Ribbon cable connection to INICT03 module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Single PCB, occupies one slot in module mounting unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication interface between host computers and ABB Bailey INICT03 modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring RS-232-C or SCSI connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control environments where redundancy and flexibility are critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary role of the IMMPI01 module?\u003c\/strong\u003e  A: It serves as the communication interface between host computers and the INICT03 module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which communication standards are supported?\u003c\/strong\u003e  A: The IMMPI01 supports RS-232-C and SCSI interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How does the module connect to termination units?\u003c\/strong\u003e  A: Connector P3 links the module to an NTMP01 termination unit, while P6 connects to the INICT03 module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the power requirement for the IMMPI01?\u003c\/strong\u003e  A: It requires +5 VDC at 415 mA, with a typical consumption of 2.08 W.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848806920376,"sku":"IMMPI01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMMPI01.jpg?v=1770889982"},{"product_id":"abb-bailey-inict03a-cnet-to-computer-transfer-module-communication-interface","title":"ABB Bailey INICT03A | Cnet-to-Computer Transfer Module | Communication Interface","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eINICT03A\u003c\/strong\u003e Cnet-to-Computer Transfer Module is a high-capacity communication interface designed to connect Bailey control systems with host computers. It provides flexible data transfer options through RS-232-C or SCSI communication, supporting large tag capacities and fast processing speeds. With robust memory resources and reliable power requirements, the module ensures efficient integration into industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product No.:\u003c\/strong\u003e \u003cstrong\u003eINICT03A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Cnet-to-Computer Transfer Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e512 KB ROM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 MB RAM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e +5 VDC at 2 A (10 W typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Rates:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS-232-C: User-selectable up to 19.2 kbaud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCSI: Up to 4 MB\/sec\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTag Capacity (Point Definitions):\u003c\/strong\u003e 30,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Single-slot PCB for Bailey control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHost computer integration with Bailey control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring high-speed communication interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge-scale process control environments with extensive tag definitions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems needing flexible RS-232-C or SCSI connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the INICT03A?\u003c\/strong\u003e  A: It transfers data between Bailey control systems and host computers via RS-232-C or SCSI interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum tag capacity supported?\u003c\/strong\u003e  A: The module can handle up to 30,000 point definitions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication speeds are available?\u003c\/strong\u003e  A: RS-232-C supports up to 19.2 kbaud, while SCSI allows up to 4 MB\/sec.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the memory specifications?\u003c\/strong\u003e  A: The module includes 512 KB ROM and 2 MB RAM.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848810983608,"sku":"INICT03A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INICT03A.jpg?v=1770890185"},{"product_id":"abb-bailey-iimcp02-infi-net-multibus-communication-processor","title":"ABB Bailey IIMCP02 | Infi-Net Multibus Communication Processor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIIMCP02\u003c\/strong\u003e Infi-Net Multibus Communication Processor Module is a dedicated communication card engineered for ABB’s Infi-Net distributed control systems. Designed to manage multibus communication, it ensures stable data transfer and reliable integration across automation platforms. Manufactured in Switzerland, the module combines compact dimensions with robust construction, making it suitable for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eIIMCP02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Multibus Communication Processor Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 2.2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 12.4 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 12.6 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e PCB-based communication processor card for rack-mounted systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Provides communication processing for Infi-Net multibus systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication backbone for ABB Bailey Infi-Net distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation environments requiring reliable multibus data exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess control systems where stable communication modules are essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the IIMCP02?\u003c\/strong\u003e  A: It serves as a communication processor for Infi-Net multibus systems, ensuring reliable data transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Where is the IIMCP02 manufactured?\u003c\/strong\u003e  A: The module is produced in Switzerland.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the physical dimensions of the unit?\u003c\/strong\u003e  A: The IIMCP02 measures 2.2 cm × 12.4 cm × 12.6 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How much does the module weigh?\u003c\/strong\u003e  A: The unit weighs approximately 1.5 kg.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848812032184,"sku":"IIMCP02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IIMCP02.jpg?v=1770890370"},{"product_id":"abb-bailey-iimcp02-infi-net-multibus-communication-processor-副本","title":"IEPAS02 | ABB Bailey Power Module 24 VDC | AC System Supply Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIIMCP02\u003c\/strong\u003e Infi-Net Multibus Communication Processor Module is a dedicated communication card engineered for ABB’s Infi-Net distributed control systems. Designed to manage multibus communication, it ensures stable data transfer and reliable integration across automation platforms. Manufactured in Switzerland, the module combines compact dimensions with robust construction, making it suitable for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eIIMCP02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Multibus Communication Processor Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 2.2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 12.4 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 12.6 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e PCB-based communication processor card for rack-mounted systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Provides communication processing for Infi-Net multibus systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication backbone for ABB Bailey Infi-Net distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation environments requiring reliable multibus data exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess control systems where stable communication modules are essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the IIMCP02?\u003c\/strong\u003e  A: It serves as a communication processor for Infi-Net multibus systems, ensuring reliable data transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Where is the IIMCP02 manufactured?\u003c\/strong\u003e  A: The module is produced in Switzerland.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the physical dimensions of the unit?\u003c\/strong\u003e  A: The IIMCP02 measures 2.2 cm × 12.4 cm × 12.6 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How much does the module weigh?\u003c\/strong\u003e  A: The unit weighs approximately 1.5 kg.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848812851384,"sku":"IEPAS02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IEPAS02.jpg?v=1770890553"},{"product_id":"abb-bailey-iniit03-infi-net-local-transfer-module-communication-interface","title":"ABB Bailey INIIT03 | Infi-Net Local Transfer Module | Communication Interface","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eINIIT03\u003c\/strong\u003e Infi-Net to Infi-Net Local Transfer Module is a communication interface designed to enable seamless data transfer between Infi-Net networks. Built for Bailey INFI 90 and NET 90 systems, this module ensures reliable connectivity and efficient communication across distributed control environments. Multiple alternate part numbers are available, making it adaptable to various system configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ASEA Brown Boveri (ABB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Bailey Controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eINIIT03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Part Numbers:\u003c\/strong\u003e YINIIT03, RINIIT03, PINIIT03, INIIT03R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e Bailey INFI 90 \/ NET 90\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Provides local transfer capability between Infi-Net networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Rack-mounted communication module for distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocal transfer of data between multiple Infi-Net networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration into Bailey INFI 90 and NET 90 distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation environments requiring reliable communication modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the INIIT03?\u003c\/strong\u003e  A: It enables local transfer of data between Infi-Net networks in Bailey control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which systems are supported by the INIIT03?\u003c\/strong\u003e  A: It is compatible with Bailey INFI 90 and NET 90 systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Are there alternate part numbers for this module?\u003c\/strong\u003e  A: Yes, the INIIT03 is also available under YINIIT03, RINIIT03, PINIIT03, and INIIT03R.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of module is the INIIT03?\u003c\/strong\u003e  A: It is a communication module designed for distributed control environments.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848813703352,"sku":"INIIT03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INIIT031.jpg?v=1770890783"},{"product_id":"abb-bailey-imset01-sequence-of-event-timing-module-i-o-synchronization-unit","title":"ABB Bailey IMSET01 | Sequence of Event Timing Module | I\/O Synchronization Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMSET01\u003c\/strong\u003e Sequence of Event Timing Module is an I\/O synchronization unit designed to provide precise time-stamping and event sequencing within Bailey control systems. By ensuring accurate time synchronization, this module supports reliable event logging and system diagnostics in distributed automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eIMSET01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Sequence of Event Timing Module (I\/O Module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Description:\u003c\/strong\u003e Sequence of Events Time Synchronization\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 76.2 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 358.14 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 279.4 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Rack-mounted module for Bailey control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Provides time synchronization and event sequencing for system monitoring and diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvent logging in Bailey INFI 90 and NET 90 distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation environments requiring precise time synchronization\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess monitoring systems where accurate event sequencing is critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the IMSET01 module?\u003c\/strong\u003e  A: It synchronizes event timing and provides accurate time-stamping for system diagnostics and monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of module is the IMSET01?\u003c\/strong\u003e  A: It is an I\/O module designed for sequence of event timing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the physical dimensions of the IMSET01?\u003c\/strong\u003e  A: The unit measures 76.2 mm × 358.14 mm × 279.4 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the IMSET01 compatible with Bailey control systems?\u003c\/strong\u003e  A: Yes, it is designed for integration into Bailey distributed control platforms.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848814260408,"sku":"IMSET01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMSET01.jpg?v=1770890970"},{"product_id":"abb-bailey-imset01-sequence-of-event-timing-module-i-o-synchronization-unit-副本","title":"IMSED01 | ABB Bailey Sequence of Events Digital Input Module | SOE Slave Card","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMSED01\u003c\/strong\u003e Sequence of Events Digital Input Module is engineered for high-speed discrete signal monitoring in Bailey \u003cstrong\u003eINFI 90\u003c\/strong\u003e and \u003cstrong\u003eSymphony Plus\u003c\/strong\u003e control systems. Unlike conventional digital input modules, the IMSED01 is optimized for Sequence of Events (SOE) applications, where precise timing of state transitions is critical. It captures and timestamps input changes with millisecond resolution, ensuring accurate event logging for diagnostics, fault reconstruction, and system analysis in mission-critical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eIMSED01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e SOE Digital Input Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Series:\u003c\/strong\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e 16 discrete input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTimestamp Resolution:\u003c\/strong\u003e 1 millisecond\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Options:\u003c\/strong\u003e 24 VDC, 48 VDC, or 125 VDC (depending on termination)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e +5 VDC (backplane powered)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to 70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-speed event capture beyond standard controller scan cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSynchronization with \u003cstrong\u003eIMSET01\u003c\/strong\u003e for unified time base across racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHardware debouncing and software filtering for noise immunity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocal signal conditioning and autonomous timestamping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time fault reporting via front-panel LEDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-swappable design for easy expansion and maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation plants requiring precise SOE monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvent logging for protective relays, circuit breakers, and emergency stop switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems where millisecond-level event capture is essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems needing synchronized event records across multiple racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What makes the IMSED01 different from standard digital input modules?\u003c\/strong\u003e  A: It is designed specifically for Sequence of Events applications, offering millisecond timestamping and synchronization with master time-keeper modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many input channels are supported?\u003c\/strong\u003e  A: The IMSED01 provides 16 discrete input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What input voltages can the module handle?\u003c\/strong\u003e  A: It supports 24 VDC, 48 VDC, or 125 VDC depending on termination configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module support hot-swapping?\u003c\/strong\u003e  A: Yes, it can be installed or removed under power for system scalability and maintenance.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848819667128,"sku":"IMSED01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMSED01.jpg?v=1770891402"},{"product_id":"abb-bailey-ipfld125-distributed-power-system-filter-module","title":"ABB Bailey IPFLD125 | Distributed Power System Filter Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIPFLD125\u003c\/strong\u003e Distributed Power System Filter Module is a discontinued power conditioning unit originally designed for Bailey INFI 90 and NET 90 systems. It provides stable filtering and regulated power distribution for field applications, supporting both AC and DC inputs. Despite being discontinued by the manufacturer, the module remains relevant in legacy installations where reliable power filtering is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB (ASEA Brown Boveri)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Bailey Controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003eIPFLD125\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Distributed Power System Filter Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs \/ Machine Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSubcategory:\u003c\/strong\u003e PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Ratings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e120 VAC, 50\/60 Hz, 4 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e240 VAC, 50\/60 Hz, 2 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e125 VDC, 4 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.00 lbs (approx. 2.27 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus:\u003c\/strong\u003e Discontinued by manufacturer (factory warranty may not apply)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e Radwell 2-year warranty available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy Bailey INFI 90 and NET 90 distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial environments requiring stable AC\/DC power filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacement module for discontinued ABB Bailey power supply units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the IPFLD125 still in production?\u003c\/strong\u003e  A: No, it has been discontinued by ABB.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What input voltages are supported?\u003c\/strong\u003e  A: The module supports 120 VAC, 240 VAC, and 125 VDC inputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What systems is the IPFLD125 compatible with?\u003c\/strong\u003e  A: It was designed for Bailey INFI 90 and NET 90 systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the factory warranty apply?\u003c\/strong\u003e  A: Factory warranty may not apply, but Radwell offers a 1-year warranty.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848871571640,"sku":"IPFLD125","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IPFLD125_1c15c806-f953-4b1f-80b2-a8b1f4521392.jpg?v=1770891659"},{"product_id":"abb-bailey-inict01-infi-net-to-computer-transfer-module-communication-interface","title":"ABB Bailey INICT01 | Infi-Net to Computer Transfer Module | Communication Interface","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eINICT01\u003c\/strong\u003e Infi-Net to Computer Transfer Module is a communication interface designed to connect Infi-Net networks with host computers. It ensures secure and efficient data transfer, supporting critical applications across industrial automation, building management, and energy systems. Compact and durable, the module integrates seamlessly into existing Bailey infrastructures, providing reliable RS-232 connectivity and consistent performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ASEA Brown Boveri (ABB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Bailey Controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eINICT01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Infi-Net Computer Transfer Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Facilitates data transfer between Infi-Net networks and computers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e RS-232 computer interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransfer Rate:\u003c\/strong\u003e Up to 19.2 kbps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Compact rack-mounted design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.588 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeamless integration with Infi-Net networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure and consistent data transfer for mission-critical applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser-friendly interface for simplified setup and configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVersatile use across industrial automation, building management, and energy systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring computer-to-network communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilding management platforms needing reliable data transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnergy management systems where secure communication is essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the INICT01?\u003c\/strong\u003e  A: It enables secure data transfer between Infi-Net networks and host computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication interface does it use?\u003c\/strong\u003e  A: The module supports RS-232 connectivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum transfer rate?\u003c\/strong\u003e  A: Up to 19.2 kbps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What power supply is required?\u003c\/strong\u003e  A: The INICT01 operates on 24 VDC.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848910860472,"sku":"INICT01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INICT01.jpg?v=1770891848"},{"product_id":"imdso04-abb-bailey-digital-output-slave-module-infi-90","title":"IMDSO04 | ABB Bailey Digital Output Slave Module | Infi 90","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMDSO04\u003c\/strong\u003e Digital Output Slave Module is designed for use within the Infi 90 distributed control system. It provides reliable digital output functionality with robust isolation and surge protection, ensuring safe and consistent operation in industrial environments. The module occupies one slot in a standard Infi 90 rack and is CSA-certified for process control applications in non-hazardous locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product Number:\u003c\/strong\u003e \u003cstrong\u003eIMDSO04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Output Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLogic Power Requirements:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage: +5 VDC (±5%)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Consumption: 135 mA typical, 200 mA maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower Dissipation: 750 mW typical, 1.2 W maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad Ratings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage: 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent: 250 mA maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOff Leakage Current: ≤10 µA at 70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOn-State Voltage Drop: ≤2.4 V at 70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e 300 V rms between output and logic circuitry, and output-to-output (CSA approved)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSurge Withstand Capability:\u003c\/strong\u003e ANSI\/IEEE C37.90A-1974 compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Single-slot installation in Infi 90 module mounting unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Conditions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e0–95% up to 55 °C (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e0–45% up to 70 °C (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Temperature: 0 °C to 70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelative Humidity:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAtmospheric Pressure: Sea level to 3 km (1.86 miles)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAir Quality: Non-corrosive environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCertification:\u003c\/strong\u003e CSA certified for ordinary (non-hazardous) locations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital output control in Bailey Infi 90 distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring isolated and surge-protected outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnvironments where reliable discrete signal switching is critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum load current supported by the IMDSO04?\u003c\/strong\u003e  A: The module supports up to 250 mA per channel at 24 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the IMDSO04 provide isolation?\u003c\/strong\u003e  A: Yes, it offers 300 V rms isolation between outputs and logic circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What surge protection standard does the module meet?\u003c\/strong\u003e  A: It complies with ANSI\/IEEE C37.90A-1974 guidelines for surge withstand capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of certification does the IMDSO04 carry?\u003c\/strong\u003e  A: It is CSA certified for use in ordinary (non-hazardous) industrial locations.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848925343928,"sku":"IMDSO04","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMDSO04.jpg?v=1770892030"},{"product_id":"abb-bailey-innis11-symphony-network-interface-module-infi-net-communication","title":"ABB Bailey INNIS11 | Symphony Network Interface Module | Infi-Net Communication","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eINNIS11\u003c\/strong\u003e Symphony Network Interface Module is a high-performance communication unit designed to provide reliable data transfer between Infi-Net networks and connected nodes. Supporting multiple communication protocols, this module ensures efficient integration across industrial automation platforms. Built with robust construction and wide operating temperature tolerance, it is suitable for demanding environments where secure and stable communication is essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ASEA Brown Boveri (ABB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Bailey Controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Product ID:\u003c\/strong\u003e \u003cstrong\u003eINNIS11\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Part Numbers:\u003c\/strong\u003e YINNIS11, RINNIS11, PINNIS11\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Network Interface Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Description:\u003c\/strong\u003e Infi-Net to Node Communication Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 73.66 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 358.14 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 271.78 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 24 VDC, 2 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -40 °C to +85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for Symphony Plus and Infi 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-performance communication capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupport for multiple communication protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReliable operation across industrial applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of Infi-Net networks with Symphony Plus distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring stable communication interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh environments where wide temperature tolerance is critical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the INNIS11?\u003c\/strong\u003e  A: It provides communication between Infi-Net networks and connected nodes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which systems are supported by the INNIS11?\u003c\/strong\u003e  A: It is compatible with Bailey INFI 90 and Symphony Plus systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the power requirements?\u003c\/strong\u003e  A: The module operates on 24 VDC at 2 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e  A: It can function reliably between -40 °C and +85 °C.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52848976756920,"sku":"INNIS11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INNIS11A.jpg?v=1770892219"},{"product_id":"abb-bailey-imrio02-remote-i-o-slave-module","title":"ABB Bailey IMRIO02 Remote I\/O Slave Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMRIO02 is a Remote I\/O Slave Module designed for Bailey INFI 90 process control systems. It provides communication between Multi-Function Processor modules and remotely located slave modules, enabling distributed process control and remote data exchange.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Remote I\/O Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMRIO02\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90\u003c\/li\u003e\n\u003cli\u003eCompatible Processor: IMMFP01, IMMFP02, IMMFP03\u003c\/li\u003e\n\u003cli\u003eCommunication Rate: 1 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eMaximum Remote Distance: 3000 m\u003c\/li\u003e\n\u003cli\u003eSupported Media: Coaxial Cable, Twinaxial Cable, Fiber Optic Cable\u003c\/li\u003e\n\u003cli\u003eStatic RAM: 8 KB\u003c\/li\u003e\n\u003cli\u003eShared RAM: 8 KB\u003c\/li\u003e\n\u003cli\u003eROM Capacity: 32 KB\u003c\/li\u003e\n\u003cli\u003eOperating Voltage (+5 VDC): 1.45 A Typical, 1.80 A Maximum\u003c\/li\u003e\n\u003cli\u003eOperating Voltage (+15 VDC): 17.5 mA Typical, 20 mA Maximum\u003c\/li\u003e\n\u003cli\u003eOperating Voltage (-15 VDC): 80 mA Typical, 90 mA Maximum\u003c\/li\u003e\n\u003cli\u003ePower Consumption (+5 VDC): 7.25 W Typical, 9.0 W Maximum\u003c\/li\u003e\n\u003cli\u003ePower Consumption (+15 VDC): 0.26 W Typical, 0.30 W Maximum\u003c\/li\u003e\n\u003cli\u003ePower Consumption (-15 VDC): 1.20 W Typical, 1.35 W Maximum\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 90% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides remote communication between Multi-Function Processors and slave modules\u003c\/li\u003e\n\u003cli\u003eSupports data transmission at 1 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eSupports coaxial, twinaxial, and fiber optic communication media\u003c\/li\u003e\n\u003cli\u003eAllows remote I\/O deployment up to 3000 meters from the controller\u003c\/li\u003e\n\u003cli\u003eIncludes internal diagnostics for module and communication link monitoring\u003c\/li\u003e\n\u003cli\u003eSupports redundant communication hardware configurations\u003c\/li\u003e\n\u003cli\u003eIntegrates with ABB Bailey INFI 90 distributed control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within the Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003eConfigure module addresses and operating options using onboard DIP switches\u003c\/li\u003e\n\u003cli\u003eConnect communication cabling through the appropriate termination unit or module\u003c\/li\u003e\n\u003cli\u003eVerify communication media compatibility before system commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of communication cables\u003c\/li\u003e\n\u003cli\u003eConfirm communication status using front-panel LED indicators during startup\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613431783608,"sku":"IMRIO02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMRIO02_2r270.png?v=1782114798"},{"product_id":"abb-bailey-immfp12-multifunction-processor-module","title":"ABB Bailey IMMFP12 Multifunction Processor Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMMFP12 is a Multi-Function Processor Module designed for INFI 90 OPEN process control systems. It executes analog, sequential, batch, and advanced control strategies while providing data acquisition, information processing, and peer-to-peer communication capabilities.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Multi-Function Processor Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMMFP12\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eMicroprocessor: 32-bit Processor\u003c\/li\u003e\n\u003cli\u003eProcessor Frequency: 16 MHz\u003c\/li\u003e\n\u003cli\u003eROM Memory: 512 KB\u003c\/li\u003e\n\u003cli\u003eRAM Memory: 512 KB\u003c\/li\u003e\n\u003cli\u003eNVRAM Memory: 256 KB\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 2 A\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 10 W Typical\u003c\/li\u003e\n\u003cli\u003eSerial Ports: Two RS-232-C Ports or One RS-232-C and One RS-485 Port\u003c\/li\u003e\n\u003cli\u003eSerial Communication Rate: Up to 19.2 kbaud\u003c\/li\u003e\n\u003cli\u003eRedundant Communication Link: 1 Mbaud Serial Link\u003c\/li\u003e\n\u003cli\u003eMaximum Station Support: 64 IISAC01 Stations or 8 NDCS03\/NDIS01 Stations\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure: Sea Level to 3000 m\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in Standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 177.8 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 35.5 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 298.4 mm\u003c\/li\u003e\n\u003cli\u003eShipping Weight: 1.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExecutes analog, sequential, batch, and advanced control applications\u003c\/li\u003e\n\u003cli\u003eProvides peer-to-peer communication within INFI 90 OPEN systems\u003c\/li\u003e\n\u003cli\u003eSupports redundant processor configurations through a 1 Mbaud communication link\u003c\/li\u003e\n\u003cli\u003eSupports programming using Function Codes, C, BASIC, Batch 90, and Ladder Logic\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostics during operation\u003c\/li\u003e\n\u003cli\u003eSupports communication with multiple remote control and operator stations\u003c\/li\u003e\n\u003cli\u003eProcesses control algorithms and data acquisition functions within a single module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within a standard INFI 90 module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect serial communication interfaces according to ABB wiring documentation\u003c\/li\u003e\n\u003cli\u003eVerify processor configuration before placing the module into service\u003c\/li\u003e\n\u003cli\u003eEnsure proper cabinet grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eMaintain the specified environmental operating conditions during operation\u003c\/li\u003e\n\u003cli\u003eVerify communication status and diagnostic indicators during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613488537784,"sku":"IMMFP12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMMFP12r270.png?v=1782114783"},{"product_id":"imaso11-abb-bailey-analog-output-slave-module","title":"IMASO11 | ABB Bailey | Analog Output Slave Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMASO11 is an Analog Output Slave Module designed for INFI 90 OPEN process control systems. It converts digital control signals from the control system into analog output signals for field devices such as control valves, actuators, and instrumentation equipment.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Analog Output Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMASO11\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eOutput Channels: 16\u003c\/li\u003e\n\u003cli\u003eOutput Signal Range: 4 to 20 mA\u003c\/li\u003e\n\u003cli\u003eOutput Resolution: 12 Bits\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 100 ms\u003c\/li\u003e\n\u003cli\u003eCommunication Interface: INFI-NET Slave Bus\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 0.55 A\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in Standard Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 177.8 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 35.5 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 297.2 mm\u003c\/li\u003e\n\u003cli\u003eShipping Weight: 0.9 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides sixteen independent analog output channels\u003c\/li\u003e\n\u003cli\u003eSupports standard 4 to 20 mA industrial control signals\u003c\/li\u003e\n\u003cli\u003eConverts digital process commands into analog field outputs\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eIntegrates with ABB Bailey INFI 90 OPEN control architectures\u003c\/li\u003e\n\u003cli\u003eSupports connection to control valves, recorders, and process instrumentation\u003c\/li\u003e\n\u003cli\u003eDesigned for distributed process control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within the module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect field wiring through the appropriate analog output termination unit\u003c\/li\u003e\n\u003cli\u003eVerify output signal configuration before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and cable shielding practices\u003c\/li\u003e\n\u003cli\u003eConfirm channel operation using system diagnostics during startup\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613498630328,"sku":"IMASO11","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMASO11_2.png?v=1782114753"},{"product_id":"innis21-abb-bailey-infi-90-network-interface-slave-module","title":"INNIS21 | ABB Bailey INFI 90 Network Interface Slave Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey INNIS21 is a Network Interface Slave Module designed for INFI 90 OPEN process control systems. It provides high-speed communication between process control modules and the INFI-NET communication network, enabling data exchange across distributed control system nodes.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Network Interface Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: INNIS21\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eNetwork Type: INFI-NET\u003c\/li\u003e\n\u003cli\u003eCommunication Rate: 10 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eProcessor: Motorola 68020\u003c\/li\u003e\n\u003cli\u003eMemory Type: Dynamic RAM and Read-Only Memory\u003c\/li\u003e\n\u003cli\u003eRedundancy Support: Yes\u003c\/li\u003e\n\u003cli\u003eCommunication Media: Coaxial Cable\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in Standard Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 177.8 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 35.5 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 297.2 mm\u003c\/li\u003e\n\u003cli\u003eShipping Weight: 1.4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides high-speed communication with the INFI-NET network\u003c\/li\u003e\n\u003cli\u003eSupports distributed process control system architectures\u003c\/li\u003e\n\u003cli\u003eFacilitates data exchange between network nodes and control modules\u003c\/li\u003e\n\u003cli\u003eSupports redundant network interface configurations\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eEnables communication across multiple INFI 90 OPEN system stations\u003c\/li\u003e\n\u003cli\u003eDesigned for mission-critical industrial automation applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within the module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect network cabling according to ABB INFI-NET installation requirements\u003c\/li\u003e\n\u003cli\u003eVerify network addressing and communication parameters before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of communication cables\u003c\/li\u003e\n\u003cli\u003eConfirm network status through module diagnostic indicators during startup\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613500301496,"sku":"INNIS21","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INNIS21.png?v=1782114833"},{"product_id":"innpm12-abb-bailey-network-processor-module","title":"INNPM12 | ABB Bailey Network Processor Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey INNPM12 is a Network Processing Module designed for INFI 90 OPEN process control systems. It manages network communications, message routing, and data transfer functions across the INFI-NET network, supporting efficient communication between distributed control system nodes.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Network Processing Module\u003c\/li\u003e\n\u003cli\u003ePart Number: INNPM12\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eNetwork Type: INFI-NET\u003c\/li\u003e\n\u003cli\u003eCommunication Rate: 10 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eProcessor Type: Motorola 68020 Microprocessor\u003c\/li\u003e\n\u003cli\u003eMemory Type: Dynamic RAM and Read-Only Memory\u003c\/li\u003e\n\u003cli\u003eRedundancy Support: Yes\u003c\/li\u003e\n\u003cli\u003eCommunication Media: Coaxial Cable\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in Standard Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 177.8 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 35.5 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 297.2 mm\u003c\/li\u003e\n\u003cli\u003eShipping Weight: 1.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides network processing and communication management functions\u003c\/li\u003e\n\u003cli\u003eSupports message routing across the INFI-NET communication network\u003c\/li\u003e\n\u003cli\u003eEnables data exchange between distributed process control nodes\u003c\/li\u003e\n\u003cli\u003eSupports redundant network communication architectures\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eOptimizes communication performance within INFI 90 OPEN systems\u003c\/li\u003e\n\u003cli\u003eIntegrates with ABB Bailey network interface and control modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within the module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect network communication cabling according to ABB installation documentation\u003c\/li\u003e\n\u003cli\u003eVerify network configuration and addressing before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of communication cables\u003c\/li\u003e\n\u003cli\u003eConfirm communication status using module diagnostic indicators during startup\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613501284536,"sku":"INNPM12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INNPM12_2.png?v=1782114846"},{"product_id":"abb-bailey-immfp02-multi-function-processor-module","title":"ABB Bailey IMMFP02 Multi-Function Processor Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMMFP02 is a Multi-Function Processor Module designed for INFI 90 OPEN process control systems. It executes control strategies, performs data acquisition and processing functions, and provides communication with other modules and system nodes within the distributed control architecture.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Multi-Function Processor Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMMFP02\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eProcessor Type: 32-bit Microprocessor\u003c\/li\u003e\n\u003cli\u003eMemory Type: RAM, ROM, and Non-Volatile Memory\u003c\/li\u003e\n\u003cli\u003eControl Functions: Regulatory, Sequential, Batch, and Logic Control\u003c\/li\u003e\n\u003cli\u003eCommunication Interface: Controlway Communication Link\u003c\/li\u003e\n\u003cli\u003eRedundancy Support: Yes\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure: Sea Level to 3000 m\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in a Standard Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExecutes multiple process control strategies within a single module\u003c\/li\u003e\n\u003cli\u003eSupports distributed control system architectures\u003c\/li\u003e\n\u003cli\u003eProvides communication with other INFI 90 OPEN modules\u003c\/li\u003e\n\u003cli\u003eSupports redundant processor configurations\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eSupports custom and application-specific control programs\u003c\/li\u003e\n\u003cli\u003eIntegrates with ABB Bailey process management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within the module mounting unit\u003c\/li\u003e\n\u003cli\u003eConfigure module parameters according to system requirements before commissioning\u003c\/li\u003e\n\u003cli\u003eConnect communication interfaces according to ABB installation documentation\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eVerify processor operation using system diagnostic functions\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613505315000,"sku":"IMMFP02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMMFP02_2r270.png?v=1782114847"},{"product_id":"abb-bailey-tas01-turbine-auto-sync-module-for-infi-90","title":"ABB Bailey TAS01 Turbine Auto Sync Module for INFI 90","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey TAS01 is a Termination Adapter Module designed for INFI 90 OPEN process control systems. It provides signal routing and interface connections between field wiring termination units and system modules, supporting reliable signal transmission within distributed control applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Termination Adapter Module\u003c\/li\u003e\n\u003cli\u003ePart Number: TAS01\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eFunction: Signal Routing and Interface Adaptation\u003c\/li\u003e\n\u003cli\u003eApplication: Field Wiring Termination Interface\u003c\/li\u003e\n\u003cli\u003eModule Interface: INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003eInstallation Method: Backplane Connection\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides interface connections between field devices and control modules\u003c\/li\u003e\n\u003cli\u003eSupports signal routing within INFI 90 OPEN systems\u003c\/li\u003e\n\u003cli\u003eSimplifies field wiring installation and maintenance\u003c\/li\u003e\n\u003cli\u003eDesigned for integration with ABB Bailey control architectures\u003c\/li\u003e\n\u003cli\u003eSupports reliable signal transmission between system components\u003c\/li\u003e\n\u003cli\u003eFacilitates organized termination and cabling arrangements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module according to ABB mounting requirements\u003c\/li\u003e\n\u003cli\u003eConnect field wiring to the designated termination unit\u003c\/li\u003e\n\u003cli\u003eVerify wiring assignments before system commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eInspect all connections for secure installation\u003c\/li\u003e\n\u003cli\u003eConfirm correct module interfacing during startup procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613521469624,"sku":"TAS01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TAS01.png?v=1782114799"},{"product_id":"abb-bailey-imfec11-ield-equipment-communication-module","title":"ABB Bailey IMFEC11 ield Equipment Communication Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMFEC11 is a Field Equipment Communication Module designed for INFI 90 OPEN process control systems. It provides communication between Multi-Function Processor modules and field equipment interfaces, supporting analog input signal acquisition and distributed process control applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Field Equipment Communication Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMFEC11\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eFunction: Field Equipment Communication and Analog Input Processing\u003c\/li\u003e\n\u003cli\u003eAssociated Processor Modules: IMMFP01, IMMFP02, IMMFP03, IMMFP11, IMMFP12\u003c\/li\u003e\n\u003cli\u003eCommunication Interface: Field Equipment Bus\u003c\/li\u003e\n\u003cli\u003eCommunication Rate: 2 Mbaud\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure: Sea Level to 3000 m\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: One Slot in a Standard Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides communication between Multi-Function Processor modules and field equipment interfaces\u003c\/li\u003e\n\u003cli\u003eSupports analog input data acquisition for process control applications\u003c\/li\u003e\n\u003cli\u003eEnables distributed field I\/O communication\u003c\/li\u003e\n\u003cli\u003eSupports high-speed field equipment bus communication\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eSupports integration within INFI 90 OPEN control architectures\u003c\/li\u003e\n\u003cli\u003eFacilitates reliable transmission of process measurement data\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a designated slot within the module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect field equipment communication cabling according to ABB installation documentation\u003c\/li\u003e\n\u003cli\u003eVerify communication configuration before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of communication cables\u003c\/li\u003e\n\u003cli\u003eCheck module status indicators during startup procedures\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613521928376,"sku":"IMFEC11","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMFEC11_3r270.png?v=1782114838"},{"product_id":"iisac01-abb-bailey-analog-control-station-module","title":"IISAC01 | ABB Bailey Analog Control Station Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IISAC01 is an Intelligent I\/O Slave Analog Control Module designed for INFI 90 OPEN process control systems. It provides analog signal processing and control functions for distributed process automation applications, enabling communication between field devices and the control system.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Intelligent I\/O Slave Analog Control Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IISAC01\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eFunction: Analog Signal Processing and Control\u003c\/li\u003e\n\u003cli\u003eCommunication Interface: Intelligent I\/O Bus\u003c\/li\u003e\n\u003cli\u003eInput Signal Type: Analog Input\u003c\/li\u003e\n\u003cli\u003eOutput Signal Type: Analog Output\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure: Sea Level to 3000 m\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: Standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides intelligent analog control functions for distributed process applications\u003c\/li\u003e\n\u003cli\u003eSupports analog signal acquisition and output processing\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with INFI 90 OPEN control architectures\u003c\/li\u003e\n\u003cli\u003eSupports communication through the Intelligent I\/O network\u003c\/li\u003e\n\u003cli\u003ePerforms continuous self-diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eSupports distributed field control strategies\u003c\/li\u003e\n\u003cli\u003eFacilitates integration of field instrumentation and control devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible INFI 90 module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to ABB installation documentation\u003c\/li\u003e\n\u003cli\u003eVerify signal configuration before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eCheck module diagnostics during startup procedures\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613537591480,"sku":"IISAC01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IISAC01.png?v=1782114854"},{"product_id":"iimlm01-abb-bailey-multibus-loop-module","title":"IIMLM01 | ABB Bailey | Multibus Loop Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IIMLM01 is a Loop Interface Module designed for INFI 90 OPEN process control systems. It provides communication between process control modules and remote loop devices, enabling data exchange and control signal transmission within distributed automation applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Loop Interface Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IIMLM01\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eFunction: Loop Communication Interface\u003c\/li\u003e\n\u003cli\u003eCommunication Type: Process Loop Data Exchange\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure: Sea Level to 3000 m\u003c\/li\u003e\n\u003cli\u003eMounting Requirement: Standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides communication between process control modules and loop devices\u003c\/li\u003e\n\u003cli\u003eSupports distributed process control architectures\u003c\/li\u003e\n\u003cli\u003eFacilitates transmission of process data and control information\u003c\/li\u003e\n\u003cli\u003eIntegrates with ABB Bailey INFI 90 OPEN systems\u003c\/li\u003e\n\u003cli\u003eSupports reliable communication within automation networks\u003c\/li\u003e\n\u003cli\u003ePerforms communication management functions for connected devices\u003c\/li\u003e\n\u003cli\u003eSupports continuous process monitoring and control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible INFI 90 module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect loop communication wiring according to ABB installation documentation\u003c\/li\u003e\n\u003cli\u003eVerify communication parameters before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eCheck communication status during startup procedures\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within the specified operating limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613570654392,"sku":"IIMLM01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IIMLM01.png?v=1782114840"},{"product_id":"abb-bailey-iemmu01-module-mounting-unit-for-infi-90","title":"ABB Bailey IEMMU01 Module Mounting Unit for INFI 90","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IEMMU01 is a Module Mounting Unit designed for INFI 90 OPEN process control systems. It provides mechanical mounting, backplane connections, and power distribution for INFI 90 control and communication modules within distributed automation applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003ePart Number: IEMMU01\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 OPEN\u003c\/li\u003e\n\u003cli\u003eFunction: Module Mounting and Backplane Interconnection\u003c\/li\u003e\n\u003cli\u003eModule Capacity: 12 Module Slots\u003c\/li\u003e\n\u003cli\u003eBackplane Type: Integrated Module Backplane\u003c\/li\u003e\n\u003cli\u003ePower Distribution: Internal Module Power Distribution\u003c\/li\u003e\n\u003cli\u003eInstallation Type: Rack Mount\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5% to 95% Non-Condensing\u003c\/li\u003e\n\u003cli\u003eAtmospheric Pressure: Sea Level to 3000 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides mounting space for INFI 90 system modules\u003c\/li\u003e\n\u003cli\u003eSupports backplane communication between installed modules\u003c\/li\u003e\n\u003cli\u003eDistributes power to control and communication modules\u003c\/li\u003e\n\u003cli\u003eSupports modular system expansion and maintenance\u003c\/li\u003e\n\u003cli\u003eIntegrates with ABB Bailey INFI 90 OPEN architectures\u003c\/li\u003e\n\u003cli\u003eFacilitates organized installation of automation hardware\u003c\/li\u003e\n\u003cli\u003eDesigned for industrial process control environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the unit in a suitable control cabinet or equipment rack\u003c\/li\u003e\n\u003cli\u003eSecure the mounting unit according to ABB installation requirements\u003c\/li\u003e\n\u003cli\u003eVerify power connections before installing modules\u003c\/li\u003e\n\u003cli\u003eInsert modules into designated slots and ensure proper seating\u003c\/li\u003e\n\u003cli\u003eEnsure proper cabinet grounding practices\u003c\/li\u003e\n\u003cli\u003eInspect backplane and module connections during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613609287864,"sku":"IEMMU01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IEMMU01.png?v=1782114794"},{"product_id":"abb-bailey-imamm03-analog-master-module-for-infi-90-network-90","title":"ABB Bailey IMAMM03 Analog Master Module for INFI 90\/Network 90","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMAMM03 is an Analog Master Module designed for INFI 90 and Network 90 process control systems. It manages analog input processing and communicates with analog slave modules to acquire, condition, and transfer process measurement data to the control system.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Analog Master Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMAMM03\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 and Network 90\u003c\/li\u003e\n\u003cli\u003eSupported Slave Modules: IMASM01, IMASM02, IMASM03, IMASM04\u003c\/li\u003e\n\u003cli\u003eMaximum Input Capacity: Up to 64 Analog Inputs\u003c\/li\u003e\n\u003cli\u003eSupported Signal Types: High-Level Voltage, Thermocouple, Millivolt, and RTD Inputs\u003c\/li\u003e\n\u003cli\u003eRAM Memory: 24 KB\u003c\/li\u003e\n\u003cli\u003eROM Memory: 36 KB\u003c\/li\u003e\n\u003cli\u003eBattery-Backed RAM: 6 KB\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: +5 VDC, +15 VDC, -15 VDC\u003c\/li\u003e\n\u003cli\u003eInstallation Requirement: One Slot in a Standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManages communication with analog slave modules\u003c\/li\u003e\n\u003cli\u003eSupports up to 64 analog input channels\u003c\/li\u003e\n\u003cli\u003eProcesses multiple analog signal types within a single system\u003c\/li\u003e\n\u003cli\u003eProvides high-resolution analog input acquisition\u003c\/li\u003e\n\u003cli\u003eSupports thermocouple, RTD, millivolt, and voltage measurements\u003c\/li\u003e\n\u003cli\u003eIntegrates with INFI 90 and Network 90 control architectures\u003c\/li\u003e\n\u003cli\u003eSupports distributed process monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003eConfigure module address settings before installation\u003c\/li\u003e\n\u003cli\u003eConnect the appropriate termination or redundancy cables to the backplane\u003c\/li\u003e\n\u003cli\u003eVerify slave module configuration before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eConfirm communication and input status during startup procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613648380088,"sku":"IMAMM03","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMAMM03r270.png?v=1782114806"},{"product_id":"imasm02-abb-bailey-isolated-analog-input-module","title":"IMASM02 | ABB Bailey Isolated Analog Input Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMASM02 is an Analog Input Slave Module designed for INFI 90 process control systems. It acquires low-level analog signals from field instruments such as thermocouples, millivolt sources, and resistance inputs, and transmits the measured data to the Analog Master Module for processing and control.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Analog Input Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMASM02\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\u003cli\u003ePower Supply: +5 VDC (±5%)\u003c\/li\u003e\n\u003cli\u003eAdditional Supply: +15 VDC \/ -15 VDC \/ +24 VDC (via TU\/TM)\u003c\/li\u003e\n\n\u003cli\u003ePower Consumption:\n  \u003cul\u003e\n    \u003cli\u003e+5 VDC: 400 mA\u003c\/li\u003e\n    \u003cli\u003e+15 VDC: 80 mA\u003c\/li\u003e\n    \u003cli\u003e-15 VDC: 45 mA\u003c\/li\u003e\n    \u003cli\u003e+24 VDC: 5 mA\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003ePower Dissipation:\n  \u003cul\u003e\n    \u003cli\u003e+5 VDC: 2.0 W\u003c\/li\u003e\n    \u003cli\u003e+15 VDC: 1.2 W\u003c\/li\u003e\n    \u003cli\u003e-15 VDC: 0.7 W\u003c\/li\u003e\n    \u003cli\u003e+24 VDC: 0.015 W\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eInput Channels: 8 low-level analog inputs\u003c\/li\u003e\n\n\u003cli\u003eSupported Signal Types:\n  \u003cul\u003e\n    \u003cli\u003eThermocouple: E, J, K, R, S, T (including Chinese E, S)\u003c\/li\u003e\n    \u003cli\u003eMillivolt: -100 mV to +100 mV\u003c\/li\u003e\n    \u003cli\u003eResistance: up to 200 kΩ\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eNormal Mode Rejection: ≥ 80 dB at 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommon Mode Voltage: ±250 V (maximum)\u003c\/li\u003e\n\u003cli\u003eCommon Mode Rejection: ≥ 120 dB at 60 Hz\u003c\/li\u003e\n\n\u003cli\u003eTermination Modules:\n  \u003cul\u003e\n    \u003cli\u003eNTAI02\u003c\/li\u003e\n    \u003cli\u003eNTTA01\u003c\/li\u003e\n    \u003cli\u003eNIAI02\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eInstallation: Standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports multiple types of low-level analog input signals\u003c\/li\u003e\n\u003cli\u003eProvides high accuracy signal acquisition for process control\u003c\/li\u003e\n\u003cli\u003eIntegrates with IMAMM series Analog Master Modules\u003c\/li\u003e\n\u003cli\u003eSupports industrial noise rejection for stable measurement\u003c\/li\u003e\n\u003cli\u003eCompatible with standard INFI 90 termination units\u003c\/li\u003e\n\u003cli\u003eDesigned for distributed analog input applications\u003c\/li\u003e\n\u003cli\u003eSupports high isolation common-mode voltage handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a standard INFI 90 module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect field wiring through approved termination units (NIAI02 \/ NTAI02 \/ NTTA01)\u003c\/li\u003e\n\u003cli\u003eVerify power supply rails before energizing the system\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of analog signal wiring\u003c\/li\u003e\n\u003cli\u003ePerform system calibration according to ABB INFI 90 procedures\u003c\/li\u003e\n\u003cli\u003eConfirm signal integrity during commissioning and startup\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613746061496,"sku":"IMASM02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMASM02r270.png?v=1782114774"},{"product_id":"imasm03-abb-bailey-analog-slave-module","title":"IMASM03 | ABB Bailey Analog Slave Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMASM03 is a Universal Analog Input Slave Module designed for INFI 90 process control systems. It acquires multiple types of analog field signals and transmits the processed data to the Analog Master Module for use in distributed control applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Universal Analog Input Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMASM03\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\u003cli\u003eInput Channels: 16 analog inputs\u003c\/li\u003e\n\u003cli\u003eSupported Signal Types:\n  \u003cul\u003e\n    \u003cli\u003eThermocouple: E, J, K, L, N, R, S, T, U (including Chinese E, S)\u003c\/li\u003e\n    \u003cli\u003eMillivolt: -100 mV to +100 mV\u003c\/li\u003e\n    \u003cli\u003eVoltage: -10 V to +10 V\u003c\/li\u003e\n    \u003cli\u003eCurrent: 4–20 mA\u003c\/li\u003e\n    \u003cli\u003eRTD: 10 Ω copper, 100 Ω platinum, 120 Ω nickel\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eSignal Processing:\n  \u003cul\u003e\n    \u003cli\u003eAnalog-to-digital conversion up to 24-bit resolution\u003c\/li\u003e\n    \u003cli\u003eChannel isolation per input\u003c\/li\u003e\n    \u003cli\u003eOpen circuit detection\u003c\/li\u003e\n    \u003cli\u003eAuto calibration and drift compensation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eCommunication Interface: Slave Expander Bus to MFP module\u003c\/li\u003e\n\n\u003cli\u003eInstallation Requirement: Standard INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to 16 isolated analog input channels\u003c\/li\u003e\n\u003cli\u003eCompatible with thermocouple, RTD, millivolt, voltage, and current signals\u003c\/li\u003e\n\u003cli\u003eProvides high-resolution signal acquisition up to 24-bit conversion\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration and temperature drift compensation\u003c\/li\u003e\n\u003cli\u003eSupports engineering unit conversion for temperature inputs\u003c\/li\u003e\n\u003cli\u003eIndividually configurable input channels\u003c\/li\u003e\n\u003cli\u003eDesigned for integration in INFI 90 distributed control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a standard INFI 90 module mounting unit\u003c\/li\u003e\n\u003cli\u003eConnect field wiring via approved termination units\u003c\/li\u003e\n\u003cli\u003eConfigure channel types and address settings before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure correct grounding and shielding for analog signal stability\u003c\/li\u003e\n\u003cli\u003eVerify communication with the Analog Master Module during startup\u003c\/li\u003e\n\u003cli\u003ePerform system validation according to ABB INFI 90 procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613754482872,"sku":"IMASM03","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMASM02_2r270.png?v=1782114778"},{"product_id":"abb-bailey-imblk01-blank-module-slot-filler-for-infi-90","title":"ABB Bailey IMBLK01 Blank Module Slot Filler for INFI 90","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMBLK01 is a Blank Module Assembly designed for INFI 90 process control systems. It is used to occupy unused slots in a Module Mounting Unit (MMU) to maintain proper mechanical protection and system configuration integrity.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Blank Module Assembly\u003c\/li\u003e\n\u003cli\u003ePart Number: IMBLK01\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\u003cli\u003eCatalog Description: Blank Faceplate\u003c\/li\u003e\n\u003cli\u003eProduct Function: Slot Occupancy \/ Mechanical Protection\u003c\/li\u003e\n\u003cli\u003eMounting Location: Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003cli\u003ePhysical Dimensions: 187.96 mm × 76.2 mm × 48.26 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOccupies unused module slots in INFI 90 system racks\u003c\/li\u003e\n\u003cli\u003eMaintains system mechanical structure and alignment\u003c\/li\u003e\n\u003cli\u003eProvides protective cover for open MMU positions\u003c\/li\u003e\n\u003cli\u003eEnsures proper cabinet configuration and installation standard\u003c\/li\u003e\n\u003cli\u003eSupports standardized INFI 90 module layout\u003c\/li\u003e\n\u003cli\u003eCompatible with ABB Bailey system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in unused slots of INFI 90 Module Mounting Units\u003c\/li\u003e\n\u003cli\u003eEnsure full insertion into backplane connector position\u003c\/li\u003e\n\u003cli\u003eDo not connect field wiring or signal cables\u003c\/li\u003e\n\u003cli\u003eMaintain correct slot mapping for system configuration\u003c\/li\u003e\n\u003cli\u003eVerify mechanical fixation during cabinet assembly\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613756022968,"sku":"IMBLK01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMBLK01.png?v=1782114737"},{"product_id":"abb-bailey-imcis02-control-i-o-slave-module-for-infi-90","title":"ABB Bailey IMCIS02 Control I\/O Slave Module for INFI 90","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMCIS02 is a Control I\/O Slave Module designed for INFI 90 process control systems. It provides both analog and digital signal acquisition and output functions, enabling interface between field devices and the Multi-Function Processor (MFP) for process control and monitoring.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Control I\/O Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMCIS02\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\n\u003cli\u003eInput\/Output Capability:\n  \u003cul\u003e\n    \u003cli\u003eAnalog Inputs: 4 channels\u003c\/li\u003e\n    \u003cli\u003eDigital Inputs: 3 channels\u003c\/li\u003e\n    \u003cli\u003eAnalog Outputs: 2 channels\u003c\/li\u003e\n    \u003cli\u003eDigital Outputs: 4 channels\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eDigital Input Types:\n  \u003cul\u003e\n    \u003cli\u003e24 VDC\u003c\/li\u003e\n    \u003cli\u003e125 VDC\u003c\/li\u003e\n    \u003cli\u003e120 VAC\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eAnalog Input Range:\n  \u003cul\u003e\n    \u003cli\u003e1–5 VDC (single-ended or differential)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eDigital Output:\n  \u003cul\u003e\n    \u003cli\u003e24 VDC open collector outputs\u003c\/li\u003e\n    \u003cli\u003eUp to 250 mA sink capability\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eAnalog Output:\n  \u003cul\u003e\n    \u003cli\u003eSelectable current or voltage mode (via configuration switch)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003ePower Supply:\n  \u003cul\u003e\n    \u003cli\u003e+5 VDC\u003c\/li\u003e\n    \u003cli\u003e+15 VDC\u003c\/li\u003e\n    \u003cli\u003e-15 VDC\u003c\/li\u003e\n    \u003cli\u003e+24 VDC (from TU\/TM)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eMounting: Standard INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003cli\u003eCommunication: Slave Expander Bus to MFP module\u003c\/li\u003e\n\u003cli\u003eHot Swap: Supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates analog and digital I\/O within a single module\u003c\/li\u003e\n\u003cli\u003eSupports multiple industrial digital input voltage standards\u003c\/li\u003e\n\u003cli\u003eProvides configurable analog output modes\u003c\/li\u003e\n\u003cli\u003eCommunicates directly with Multi-Function Processor via expander bus\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for maintenance without system shutdown\u003c\/li\u003e\n\u003cli\u003eSuitable for distributed process control applications\u003c\/li\u003e\n\u003cli\u003eCombines signal acquisition and output control functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a standard INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003cli\u003eConnect field wiring through appropriate TU\/TM termination units\u003c\/li\u003e\n\u003cli\u003eEnsure correct slave address configuration before operation\u003c\/li\u003e\n\u003cli\u003eVerify power rails before system energization\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of field wiring\u003c\/li\u003e\n\u003cli\u003eConfirm communication status with MFP during startup\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613757137080,"sku":"IMCIS02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMCIS02_3r270.png?v=1782114821"},{"product_id":"abb-bailey-imcis22-control-i-o-slave-module","title":"ABB Bailey IMCIS22 Control I\/O Slave Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMCIS22 is a Control Input\/Output Slave Module designed for INFI 90 process control systems. It provides an interface between field digital\/analog signals and the control system, enabling both signal acquisition and control output functions within distributed automation applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Control I\/O Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMCIS22\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Symphony\u003c\/li\u003e\n\n\u003cli\u003eNet Weight: 0.2 kg\u003c\/li\u003e\n\u003cli\u003eShipping Weight: 1.5 kg\u003c\/li\u003e\n\n\u003cli\u003ePower Supply: 24 VDC (system backplane)\u003c\/li\u003e\n\n\u003cli\u003eSignal Types Supported:\n  \u003cul\u003e\n    \u003cli\u003eDigital Inputs (24 VDC, 48 VDC, 125 VDC, 120 VAC)\u003c\/li\u003e\n    \u003cli\u003eAnalog Inputs (1–5 VDC)\u003c\/li\u003e\n    \u003cli\u003eAnalog Outputs (configuration dependent)\u003c\/li\u003e\n    \u003cli\u003eDigital Outputs (24 VDC open collector \/ relay depending on configuration)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eMounting: Standard INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003cli\u003eCommunication: I\/O Expander Bus\u003c\/li\u003e\n\u003cli\u003eFunction: Mixed Control I\/O (Analog + Digital)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCombines analog and digital I\/O functions in a single module\u003c\/li\u003e\n\u003cli\u003eSupports flexible field signal interfacing for control applications\u003c\/li\u003e\n\u003cli\u003eProvides direct communication with INFI 90 controller modules\u003c\/li\u003e\n\u003cli\u003eDesigned for distributed process control architectures\u003c\/li\u003e\n\u003cli\u003eSupports industrial signal isolation and filtering functions\u003c\/li\u003e\n\u003cli\u003eEnables compact I\/O integration in rack systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003eConnect field wiring through appropriate termination units\u003c\/li\u003e\n\u003cli\u003eVerify backplane and I\/O expander bus connection before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure correct grounding and shielding of field wiring\u003c\/li\u003e\n\u003cli\u003eConfirm module configuration and addressing before operation\u003c\/li\u003e\n\u003cli\u003eFollow ABB INFI 90 installation procedures for commissioning\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613757792440,"sku":"IMCIS22","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMCIS22_2.png?v=1782114732"},{"product_id":"imcpm02-abb-bailey-communication-port-module","title":"IMCPM02 | ABB Bailey | Communication Port Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMCPM02 is a Communication Port Module designed for INFI 90 process control systems. It provides communication interface capabilities between control system components and external communication networks, supporting data exchange and system integration functions.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Communication Port Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMCPM02\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\u003cli\u003eFunction: System Communication Interface\u003c\/li\u003e\n\u003cli\u003eCommunication Role: Data Transfer Between Control Modules and External Systems\u003c\/li\u003e\n\u003cli\u003eMounting: Standard INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003cli\u003eBus Interface: Controlway \/ System Communication Backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides communication interface for INFI 90 control systems\u003c\/li\u003e\n\u003cli\u003eSupports data exchange between system modules\u003c\/li\u003e\n\u003cli\u003eEnables integration with external communication networks\u003c\/li\u003e\n\u003cli\u003eDesigned for distributed control system architecture\u003c\/li\u003e\n\u003cli\u003eSupports reliable system-level communication handling\u003c\/li\u003e\n\u003cli\u003eCompatible with ABB Bailey INFI 90 modular systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003eEnsure correct backplane connection for communication bus\u003c\/li\u003e\n\u003cli\u003eVerify system configuration before commissioning\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding and shielding practices\u003c\/li\u003e\n\u003cli\u003eFollow ABB INFI 90 installation procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613758677176,"sku":"IMCPM02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMCPM02r270.png?v=1782114790"},{"product_id":"imdsm05-abb-bailey-digital-i-o-module-for-infi-90","title":"IMDSM05 | ABB Bailey | Digital I\/O Module for INFI 90","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMDSM05 is a Digital Slave Module (DSM) used in the INFI 90 Process Management System. It interfaces up to sixteen digital field signals with Multi-Function Processor (MFP) or Logic Master Module (LMM) for process monitoring and control.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Digital Slave Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMDSM05\u003c\/li\u003e\n\u003cli\u003eSystem: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\n\u003cli\u003eI\/O Capacity: 16 digital I\/O circuits\u003c\/li\u003e\n\u003cli\u003eSignal Type: Digital inputs \/ outputs (24 VDC field signals)\u003c\/li\u003e\n\n\u003cli\u003ePower Supply:\n  \u003cul\u003e\n    \u003cli\u003e+5 VDC (logic power)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eBackplane Communication:\n  \u003cul\u003e\n    \u003cli\u003eSlave Expander Bus (to MFP \/ LMM)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eMounting:\n  \u003cul\u003e\n    \u003cli\u003eSingle slot Module Mounting Unit (MMU)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eTermination:\n  \u003cul\u003e\n    \u003cli\u003eTerminal Unit (TU) via P3 connector\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003eConfiguration:\n  \u003cul\u003e\n    \u003cli\u003eAddress set via dipswitch (S1)\u003c\/li\u003e\n    \u003cli\u003eFunction Code 84 in master module configuration\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 16 independent digital I\/O circuits\u003c\/li\u003e\n\u003cli\u003eEach circuit can be configured as input or output\u003c\/li\u003e\n\u003cli\u003eProvides interface between field devices and INFI 90 system\u003c\/li\u003e\n\u003cli\u003eSupports LED status indication for all I\/O points\u003c\/li\u003e\n\u003cli\u003eHot-swappable module design (system dependent)\u003c\/li\u003e\n\u003cli\u003eSupports integration with MFP, LMM, and MFC modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003cli\u003eConnect via Slave Expander Bus to master module\u003c\/li\u003e\n\u003cli\u003eSet module address using S1 dipswitch\u003c\/li\u003e\n\u003cli\u003eConfigure Function Code 84 in master module\u003c\/li\u003e\n\u003cli\u003eConnect field wiring via termination unit (TU)\u003c\/li\u003e\n\u003cli\u003eEnsure correct alignment of P1, P2, P3 connectors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613759463608,"sku":"IMDSM05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMDSM05_1.png?v=1782114845"},{"product_id":"abb-bailey-imdsi02-digital-slave-input-module","title":"ABB Bailey IMDSI02 Digital Slave Input Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe ABB Bailey IMDSI02 is a Digital Slave Input (DSI) module designed for INFI 90 process control systems. It brings sixteen separate digital field signals into the INFI 90 system for processing and monitoring, where they are used by master modules for control functions.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Digital Slave Input Module\u003c\/li\u003e\n\u003cli\u003ePart Number: IMDSI02\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: ABB Bailey INFI 90 \/ Network 90\u003c\/li\u003e\n\u003cli\u003eInput Channels: 16 digital inputs\u003c\/li\u003e\n\u003cli\u003eInput Devices: Contact closure, switch, solenoid\u003c\/li\u003e\n\u003cli\u003eFunction: Field digital signal acquisition\u003c\/li\u003e\n\u003cli\u003eCommunication: Slave module via INFI 90 system architecture\u003c\/li\u003e\n\u003cli\u003eMounting: Standard INFI 90 Module Mounting Unit (MMU)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides acquisition of sixteen discrete field input signals\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with INFI 90 control system architecture\u003c\/li\u003e\n\u003cli\u003eSupports monitoring and control of process field devices\u003c\/li\u003e\n\u003cli\u003eDesigned for distributed control system applications\u003c\/li\u003e\n\u003cli\u003eCompatible with standard INFI 90 slave module framework\u003c\/li\u003e\n\u003cli\u003eEnables reliable transmission of digital field status signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a standard INFI 90 Module Mounting Unit\u003c\/li\u003e\n\u003cli\u003eConnect field wiring from contact closure or switching devices\u003c\/li\u003e\n\u003cli\u003eVerify module seating and backplane connection before commissioning\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of field wiring\u003c\/li\u003e\n\u003cli\u003eConfirm input status during system startup and testing\u003c\/li\u003e\n\u003cli\u003eFollow ABB INFI 90 installation and maintenance procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53613759987896,"sku":"IMDSI02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IMDSI02.png?v=1782114856"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/abb-bailey-net-90-and-infi-90.oembed?page=4","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}