{"title":"Allen-Bradley Point I\/O","description":"\u003cp\u003eThis collection includes Allen-Bradley Point I\/O modules from the 1734 series, widely used for distributed I\/O applications in industrial automation and control environments.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1734-aent-point-i-o-ethernet-ip-communication-adapter-module","title":"Allen-Bradley 1734-AENT POINT I\/O EtherNet\/IP Communication Adapter Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-AENT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance EtherNet\/IP communication adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O platform\u003c\/strong\u003e, providing a reliable interface between distributed I\/O modules and a centralized EtherNet\/IP controller. Acting as the gateway for a POINT I\/O assembly, it enables high-speed exchange of real-time I\/O data and diagnostic information over standard Ethernet networks.\u003c\/p\u003e\n\u003cp\u003eDesigned for flexible, distributed control architectures, the 1734-AENT helps reduce wiring costs and improve system scalability. A single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10\/100 Mbps RJ45 Ethernet port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith auto-negotiation supports common\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estar and tree topologies\u003c\/strong\u003e, while integrated status LEDs allow quick, localized diagnostics of module, network, and POINTBus operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1734-AENT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × RJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps, full or half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStar, Tree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 6 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePOINTBus Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 A @ 5 V DC (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT5 shielded or unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Red\/Green LEDs (Module, Network, POINTBus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.23 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eCore Application Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Architectures\u003c\/strong\u003e\u003cbr\u003eLocating POINT I\/O racks close to machines while maintaining high-speed connectivity to ControlLogix or CompactLogix controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Process Monitoring\u003c\/strong\u003e\u003cbr\u003eTransferring digital and analog I\/O data together with module diagnostics for enhanced visibility and predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Expansion\u003c\/strong\u003e\u003cbr\u003eAdding new I\/O nodes to an existing EtherNet\/IP network without major control system redesign.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many POINT I\/O modules can the 1734-AENT support?\u003c\/strong\u003e\u003cbr\u003eA: Up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e63 POINT I\/O modules\u003c\/strong\u003e, provided the total backplane current consumption does not exceed the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0 A POINTBus limit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1734-AENT support Device Level Ring (DLR)?\u003c\/strong\u003e\u003cbr\u003eA: No. The standard 1734-AENT has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle Ethernet port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand supports star or tree topologies only. For DLR, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENTR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(dual-port) adapter is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IP address be set manually?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The IP address can be configured using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eon-board thumbwheel switches\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBOOTP\/DHCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware tools.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52524455035064,"sku":"1734-AENT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-AENT1.jpg?v=1770084426"},{"product_id":"1734-ib8-allen-bradley-point-i-o-8-point-digital-dc-sinking-input-module","title":"1734-IB8 | Allen-Bradley | POINT I\/O 8-Point Digital DC Sinking Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IB8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-density, distributed I\/O solution within the POINT I\/O family. This module provides eight digital input channels for 24V DC sinking applications, allowing your PLC system to monitor sensors, switches, and other discrete field devices. Its modular, \"slice\" design significantly reduces the footprint within control cabinets while maintaining high-speed data throughput. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automated systems benefit from factory-certified components and maximum operational life.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital DC Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSinking (24V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBase Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-TB or 1734-TBS Terminal Base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Style (IP20)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11 lbs (0.05 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Compact Slice Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-IB8 utilizes a slim profile that maximizes I\/O density in cramped control panels. Engineers can scale system capacity by adding modules horizontally without expanding the vertical height of the assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability (RIUP):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). Maintenance teams replace faulty modules without shutting down the entire backplane, drastically reducing downtime in continuous manufacturing processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module mates with 1734-TB or 1734-TBS terminal bases. This separation of the electronic module from the wiring base allows for pre-wiring of the cabinet and simplifies module replacement without disturbing field connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Point Bus Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-IB8 transmits digital signals directly through the POINT I\/O backplane to the communication adapter. This eliminates the need for individual signal wires to the main PLC rack, lowering installation labor and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between a sinking input and a sourcing input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA sinking input module like the 1734-IB8 provides a path to the negative common (ground). You must use \"Sourcing\" field devices (PNP) that provide the positive 24V DC signal to the module to complete the circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1734-IB8 require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You must install the 1734-IB8 onto a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal base assembly. The base provides the physical connection to the POINT I\/O backplane and the screw or spring-clamp terminals for your field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module with an Ethernet communication adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. The 1734-IB8 works seamlessly with 1734-AENT or 1734-AENTR Ethernet\/IP adapters, as well as ControlNet or DeviceNet adapters, making it a versatile choice for distributed I\/O architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the IP20 rating affect installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IP20 \"Open Style\" rating means the module lacks protection against liquids. You must install the 1734-IB8 inside a properly rated industrial enclosure (NEMA 4, 12, or IP65) to protect the electronics from moisture, conductive dust, and other environmental contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414131925176,"sku":"1734-IB8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-IB8.jpg?v=1777366632"},{"product_id":"allen-bradley-1734-ob8-point-i-o-8-point-digital-dc-sourcing-output-module","title":"Allen-Bradley 1734-OB8 POINT I\/O 8-Point Digital DC Sourcing Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OB8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital sourcing output module within the versatile POINT I\/O system. This module provides eight independent channels to drive 24V DC loads, including solenoids, actuators, and indicator lights. Its granular \"slice\" architecture allows engineers to scale distributed I\/O systems with precision, minimizing cabinet space while maintaining high-speed control logic. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing factory-sealed hardware to ensure the highest electrical integrity for your automation infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10V DC to 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Amp per channel (2.0 Amps max per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax On-State Voltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Delay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 Milliseconds (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amps for 10 ms (Repeatable every 3 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Signal Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA maximum signal delay of only 0.1 milliseconds ensures near-instantaneous execution of control commands. This high-speed performance targets precision applications where timing synchronization between the CPU and field actuator remains critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Current Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel supports a 1.0 Amp current rating, allowing the module to drive larger loads directly without interposing relays. The hardware manages surge currents up to 2 Amps for 10 milliseconds, effectively handling the initial inrush of inductive components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Diagnostic Matrix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module faceplate features 8 yellow status LEDs for individual output monitoring and 2 bi-color (Green\/Red) LEDs for module and network health. This comprehensive display allows maintenance teams to identify faulty channels or communication drops at a glance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Modular Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-OB8 utilizes a compact, 12mm wide \"slice\" design. This solves the challenge of high-density I\/O requirements in limited cabinet spaces, allowing for expanded I\/O counts without significantly increasing the DIN rail footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does \"Sourcing\" mean for the 1734-OB8 outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a sourcing module, the 1734-OB8 supplies the positive voltage (L1) to the field load. To complete the circuit, you must connect the other side of your field device to the common ground (L2). This module pairs perfectly with sinking input field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1734-OB8 handle inductive loads like solenoid valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The 0.2V maximum voltage drop and its ability to handle repeatable 2 Amp surges make it suitable for small to medium inductive loads. However, for maximum contact life and EMI reduction, we recommend using external suppression (diodes) at the load site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You must install the 1734-OB8 onto a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal base assembly. The terminal base provides the physical mounting to the DIN rail and the connection points for your field-side wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the 50V continuous isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe isolation barrier protects the internal POINT I\/O backplane and the connected communication adapter from electrical noise or voltage spikes occurring on the field-side 24V DC wiring. This ensures a localized fault does not compromise the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414133825720,"sku":"1734-OB8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-OB8.jpg?v=1777366752"},{"product_id":"1734-ep24dc-allen-bradley-point-i-o-24v-dc-expansion-power-supply","title":"1734-EP24DC | Allen-Bradley | POINT I\/O 24V DC Expansion Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-EP24DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical infrastructure component for extended POINT I\/O configurations. This Expansion Power Supply breaks the internal communication bus to provide additional supplemental power when the current draw of the I\/O modules exceeds the capacity of the network adapter. It regenerates the 5V system power for the backplane and provides a fresh 10A field power bus to drive downstream sensors and actuators. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your distributed I\/O rack maintains stable voltage levels and noise isolation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10V DC to 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Bus Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Amps Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 17 Modules (Based on current load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Amps for 10 Milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.8 Watts @ 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 BTU\/hr @ 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 lbs (0.17 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtends System Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-EP24DC overcomes the power limitations of standard communication adapters. By injecting fresh power into the backplane, it allows for the expansion of up to 17 additional I\/O modules, facilitating large-scale distributed control without adding a second network node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Zone Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides 50V continuous isolation between the input power and the backplane. This barrier prevents electrical noise or field-side surges from propagating back to the CPU or network adapter, protecting sensitive logic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Inrush Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe circuitry handles inrush currents of up to 6 Amps for 10 milliseconds. This capability prevents nuisance tripping during system startup when multiple downstream inductive loads or capacitive sensors energize simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostic Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo dedicated green LEDs provide immediate visual confirmation of system health. One indicator monitors the 24V field power status, while the second verifies the 5V system logic power, allowing maintenance teams to differentiate between field-side and logic-side power failures instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: When do I specifically need to add a 1734-EP24DC to my POINT I\/O rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must install a 1734-EP24DC when the total current required by your I\/O modules exceeds the output of your adapter (typically 1 Amp for 5V system power). Additionally, you use it to create separate \"power groups\" if you need to isolate certain modules from others for safety or noise reasons.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the 1734-EP24DC to provide different voltages to the field bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This model specifically targets 24V DC systems. It passes the 24V DC input directly to the internal field power bus. If your application requires AC power for specific I\/O modules, you must utilize the 1734-FPD (Field Power Distributor) or an AC-rated expansion supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1734-EP24DC occupy a network node address?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The expansion power supply does not communicate data and does not require an IP address or node ID. It functions purely as a power hardware component, though it does physically occupy one slot on the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should I calculate the number of modules this supply can support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSum the \"PointBus Current\" (5V) and the \"Field Power Current\" (24V) for each module placed to the right of the 1734-EP24DC. Ensure the total PointBus current does not exceed the supply’s rating and that the total field current remains under 10 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414136479928,"sku":"1734-EP24DC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-EP24DC.jpg?v=1777366940"},{"product_id":"allen-bradley-1734-top-point-i-o-one-piece-terminal-base-assembly","title":"Allen-Bradley 1734-TOP POINT I\/O One-Piece Terminal Base Assembly","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-TOP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the essential mounting and wiring foundation for the POINT I\/O system. This one-piece terminal base assembly provides the physical interface between the PointBus backplane and the functional I\/O module. It facilitates secure field wiring via eight screw-clamp terminals while distributing field-side power to the installed module. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring a precise mechanical fit and optimal electrical conductivity for your distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAssembly Design\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne-Piece Module Base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 300V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Terminal Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Top Hat)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated DIN Rail Grounding\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Keying\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded (Prevents incorrect module insertion)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 lbs (0.11 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified One-Piece Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated design combines the terminal block and the mounting base into a single unit. This reduces installation time and eliminates the risk of misplacing sub-components during high-volume cabinet assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Mechanical Keying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-TOP features a mechanical keying system. This safeguard prevents the accidental insertion of a module into an incompatible base, protecting your hardware from voltage-level mismatches and wiring errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe base handles up to 8 Amps of terminal current. This capacity supports high-demand field devices and ensures that the integrated field power bus maintains stable delivery without overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Grounding Path:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly establishes a direct grounding connection through the DIN rail mounting clip. This design simplifies the grounding process and improves the system's resistance to electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main difference between the 1734-TOP and the 1734-TB?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-TOP features a one-piece assembly design, whereas the 1734-TB consists of a separate mounting base and a removable terminal block. The 1734-TOP simplifies initial installation, but the 1734-TB allows for easier terminal block replacement without removing the base from the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1734-TOP support spring-clamp wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 1734-TOP utilizes screw-clamp terminals. If your application requires vibration-resistant spring-clamp terminations, you should select the 1734-TOP3 or 1734-TBS models instead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I set the mechanical keying for a specific module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou manually rotate the orange keying switch on the 1734-TOP to the position specified in your I\/O module’s installation manual. This physical barrier ensures only the correctly assigned module type seats into the base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the 1734-TOP with any POINT I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The 1734-TOP provides a universal backplane interface and 8 terminals, making it compatible with the vast majority of digital and analog POINT I\/O modules, provided the module’s pinout matches an 8-terminal configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414137790648,"sku":"1734-TOP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-TOP2.jpg?v=1777367134"},{"product_id":"allen-bradley-1734-ow4-point-i-o-4-channel-relay-output-module","title":"Allen-Bradley 1734-OW4 POINT I\/O 4-Channel Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OW4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density, 4-channel electromechanical relay output module within the POINT I\/O family. It provides four Form A (normally open) isolated contacts to control a variety of load types, including solenoids, contactors, and motor starters. This module bridges the gap between low-voltage logic and high-power field devices across distributed I\/O networks. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains factory-spec switching integrity and long-term cycle life.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OW4 utilizes high-grade contact materials to handle significant inductive and resistive loads:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Form A Isolated (N.O.) Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V AC, 2.0 A @ 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5…30V DC, 2.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous), Tested @ 2550V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V DC, 90 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 Hz max @ rated load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100,000 operations (minimum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25…2.5 mm² (22…14 AWG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.06 kg (0.13 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OW4 addresses specific field integration challenges through its compact, modular design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 250V continuous isolation between individual contact sets and the field-side to system-side. This architecture protects sensitive backplane electronics from voltage spikes and transients generated by high-power field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimal Heat Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a maximum power dissipation of only 0.5 W, this module facilitates high-density mounting. It prevents heat saturation in small enclosures, even when multiple relay modules operate simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe POINT I\/O form factor allows you to add relay channels in increments of four. This solves the problem of \"over-provisioning,\" where engineers previously had to buy 8 or 16-channel blocks for small-scale switching tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Snubber Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated snubber circuit manages off-state leakage and protects the contacts during inductive \"break\" operations (180 VA break rating). This extends the mechanical life of the relay beyond standard commercial-grade components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1734-OW4 switch both AC and DC loads on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because each of the four relay outputs is isolated, you can mix different voltage levels and types (AC or DC) across the channels, provided each remains within the 250V isolation and 2.0 A current limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum switching speed for this relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module supports a maximum switching frequency of one operation every three seconds (0.3 Hz). Exceeding this rate with a full rated load will significantly reduce the expected electrical life of the contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-OW4 installs into a 1734-TB or 1734-TBS terminal base. The base determines the final screw torque, but the module itself handles the signal routing. Ensure you select the base that matches your wiring preference (screw or spring clamp).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with any POINT I\/O adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-OW4 maintains universal compatibility with all POINT I\/O adapters, including EtherNet\/IP (1734-AENT), ControlNet, and DeviceNet versions. It draws 90 mA from the backplane, so you must calculate your power budget when assembling large I\/O racks.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53423144304824,"sku":"1734-OW4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-OW4.jpg?v=1777540892"},{"product_id":"allen-bradley-1734-tb-point-i-o-screw-clamp-terminal-base-assembly","title":"Allen-Bradley 1734-TB POINT I\/O Screw-Clamp Terminal Base Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the essential mounting and wiring infrastructure for the POINT I\/O system. This terminal base assembly comprises the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB mounting base\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-RTB removable terminal block\u003c\/strong\u003e, forming a complete unit that supports secure module installation and field-side wiring. It establishes the backplane connection for signal and power distribution across the I\/O rack. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring optimal contact integrity for your distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-TB utilizes a robust open-style design optimized for standard industrial enclosures:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Base Assembly (Complete)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponents Included\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-MB (Mounting Base) \u0026amp; 1734-RTB (Removable Block)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Screw-Clamp Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField-side wiring to I\/O module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal or Vertical DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBody Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Style\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 lbs (0.10 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAll 1734 POINT I\/O Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-TB solves critical wiring and maintenance challenges in high-density automation environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance (RTB Design):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe removable terminal block allows technicians to replace I\/O modules without disconnecting individual field wires. This feature eliminates wiring errors and drastically reduces Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Screw-Clamp Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8-point screw-clamp mechanism ensures high-vibration resistance. It provides a gas-tight connection that prevents signal intermittent faults in harsh industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid System Scaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe base snaps directly onto standard 35mm DIN rails and interlocks with adjacent bases. This modular \"slide-and-lock\" mechanism allows for instantaneous expansion of the I\/O rack without complex mechanical fasteners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical\/Horizontal Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe open-style chassis supports both vertical and horizontal mounting. This flexibility allows engineers to fit POINT I\/O racks into shallow junction boxes or narrow cable ducts where space remains at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1734-TB and the 1734-TBS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-TB utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew-clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminals for traditional, high-torque wire retention. The 1734-TBS utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espring-clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminals for faster, tool-free wiring. Both bases provide the same electrical functionality and backplane connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-TB include the mounting base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1734-TB is a complete assembly that includes both the 1734-MB (mounting base) and the 1734-RTB (removable terminal block). You do not need to purchase these components separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this terminal base compatible with all POINT I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-TB supports most digital and analog POINT I\/O modules. However, high-density modules (such as those with more than 8 points) may require a different terminal base configuration. Always check your specific I\/O module's wiring requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure a Brand New unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that every 1734-TB unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ships in its original Allen-Bradley factory packaging. We do not sell \"new-other\" or refurbished bases, ensuring the screw threads and gold-plated backplane pins remain in pristine, unused condition.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53423191359672,"sku":"1734-TB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-OW4__1_e3f47d0e-d44d-45c8-98f7-6177bcdeaaad.jpg?v=1777540995"},{"product_id":"allen-bradley-1734-ie4s-point-i-o-safety-analog-input-module","title":"Allen-Bradley 1734-IE4S POINT I\/O Safety Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE4S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, safety-rated analog input module within the POINT Guard I\/O™ family. This module enables the integration of safety-critical analog devices—such as pressure transducers, temperature sensors, and flow meters—into a standard POINT I\/O rack. It provides 4 channels of single-ended inputs and supports complex safety functions up to SIL 3 and PLe standards. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety instrumented systems (SIS) operate with maximum integrity from day one.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IE4S delivers precise signal acquisition through the following technical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 \/ PLe capable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 Volts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermocouples (TC) and RTDs (Pt, Ni, Cu)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePer-channel isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Platform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINTBus backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.19 lbs (0.09 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact POINT I\/O footprint allows engineers to deploy safety-rated analog sensing in extremely tight control cabinets. This eliminates the need for bulky traditional safety relays or oversized chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Sensor Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module accepts a wide variety of inputs, including RTDs, Thermocouples, and standard 4-20mA signals. This versatility reduces your spare parts inventory by consolidating multiple sensing needs into a single module type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-IE4S continuously monitors channel health. It detects short circuits, open wires, and out-of-range fluctuations instantly, triggering a safe state to protect both personnel and machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePer-channel isolation prevents ground loops and minimizes the impact of electromagnetic interference (EMI) in noisy industrial environments. This ensures high-fidelity data transmission for critical safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1734-IE4S operate in a standard POINT I\/O rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module interfaces via the standard POINTBus backplane. However, you must use a GuardLogix® controller or a similar safety-capable processor to manage the safety instructions and achieve SIL\/PL ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support 4-20 mA loop-powered sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The module handles standard 0-20 mA and 4-20 mA current loops, providing the precision required for high-stakes safety analog sensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product factory sealed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee every 1734-IE4S we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the original manufacturer’s packaging with all factory seals intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle RTD temperature measurements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes built-in linearization and compensation for Platinum (Pt), Nickel (Ni), and Copper (Cu) RTD types. You simply configure the sensor type in the Studio 5000® environment to begin accurate safety-rated temperature monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53459798753464,"sku":"1734-IE4S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-IE4S.jpg?v=1778659730"},{"product_id":"1734-oe4c-allen-bradley-point-i-o-1734-analog-output-module","title":"1734-OE4C Allen-Bradley | Point I\/O 1734 Analog Output Module","description":"\u003ch4\u003eProduct Overview\u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1734-OE4C\u003c\/strong\u003e is a high-precision analog output module belonging to the versatile Point I\/O 1734 series. Engineers deploy this module to drive analog actuators, control valves, and regulate variable frequency drives within distributed control systems. It converts digital control signals into accurate current outputs, ensuring seamless integration between your PLC logic and physical field devices. We supply this product as 100% Brand New and in original packaging, guaranteeing optimal performance for your automation infrastructure.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePoint I\/O 1734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4 Single-Ended Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCurrent Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Conversion Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 microsecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e75 mA at 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSigned Integer Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-20 to 55°C (-4 to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEngineering Advantages\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eRapid and Flexible DIN Rail Installation\u003c\/strong\u003e\u003cbr\u003eThe 1734-OE4C features a compact, modular design that significantly reduces panel space requirements. You can mount this module directly onto a standard DIN rail, allowing for quick installation and effortless replacement in tight control cabinets. Its modular architecture lets you scale your I\/O configuration precisely to your application's needs, eliminating wasted resources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Process Control\u003c\/strong\u003e\u003cbr\u003eWith an output conversion rate of just 1 microsecond, this module delivers near-instantaneous response times. This speed is critical for applications requiring tight closed-loop control, such as regulating chemical dosing pumps or adjusting motor speeds in real-time. The module outputs precise 0-20 mA or 4-20 mA current signals, which resist electrical noise over long cable runs, ensuring your field devices receive accurate commands.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized for Harsh Industrial Environments\u003c\/strong\u003e\u003cbr\u003eDesigned to withstand demanding factory conditions, the 1734-OE4C operates reliably in temperatures ranging from -20 to 55 degrees Celsius. It also withstands operating shocks up to 30 G, making it suitable for heavy machinery and vibrating environments. This durability minimizes unplanned downtime and protects your investment in critical control hardware.\u003c\/p\u003e\n\u003ch4\u003eFAQs\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of analog signals does this module output?\u003c\/strong\u003e\u003cbr\u003eA: The 1734-OE4C provides 4 channels of current output. You can configure each channel to output either a 0 to 20 mA or a 4 to 20 mA signal, making it compatible with a wide range of industrial actuators and control valves.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How fast does the module update its output signals?\u003c\/strong\u003e\u003cbr\u003eA: The module features a rapid output conversion rate of 1 microsecond. This ensures that your control system can react almost instantly to changes in the process, which is essential for high-speed automation tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I install this module in a high-vibration environment?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The 1734-OE4C is rated for an operating shock of 30 G. Its robust construction allows it to maintain stable performance even in environments with significant mechanical vibration, such as packaging lines or heavy manufacturing floors.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53468255748280,"sku":"1734-OE4C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-OE4C.jpg?v=1778834367"},{"product_id":"allen-bradley-1734-ie8c-point-i-o-8-channel-analog-current-input-module","title":"Allen-Bradley 1734-IE8C POINT I\/O 8-Channel Analog Current Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-IE8C functions as a high-density analog current input module within the POINT I\/O distributed hardware platform. This compact module digitizes raw 4–20 mA or 0–20 mA current loops from field transmitters, including pressure sensors, flow meters, and temperature transducers, converting them into precise signed integer data values for the host controller. We distribute this critical network slice exclusively in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure exact out-of-the-box calibration, prevent channel-to-channel crosstalk, and maintain uninterrupted signal tracking across your remote I\/O nodes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRockwell Automation \/ Allen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-IE8C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e612598347872\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Analog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Single-Ended Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Range Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA or 0 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Conversion Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigma-Delta Converter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNative Data Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigned Integer Format\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Absolute Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1% Full Scale at 25°C (77°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA at 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 Watts Maximum at 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Keyswitch Position\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePosition 3 Setup Location\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 G Peak Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Assembly Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 lbs (0.11 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximizes Channel Density in Cramped Enclosures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module packs eight independent analog input channels into an ultra-slim, 0.25 lbs physical footprint. This high-density arrangement allows control engineers to expand analog instrumentation counts inside small remote terminal boxes and machine-mount junction panels without upgrading enclosure sizes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilters Out Severe Plant-Floor Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard Sigma-Delta conversion engine oversamples the incoming current waves, filtering out high-frequency electrical harmonics and common-mode noise generated by nearby variable frequency drives (VFDs). This processing delivers an absolute accuracy of 0.1% full scale directly to your master control registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLowers Panel Power and Cooling Burden:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe optimized circuit design draws a minimal 75 mA from the 5V DC POINTBus backplane while limiting internal power dissipation to 0.6 Watts at 28.8V DC. This low thermal output prevents localized heat pockets within tightly packed DIN-rail assemblies, extending the operating life of adjacent communications adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGuarantees Mistake-Proof Field Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module chassis keys directly into Position 3 on standard 1734-TB terminal bases. This mechanical interlock blocks installers from accidentally sliding a digital or high-voltage module into an analog slot during rapid field maintenance, preventing component over-voltage destruction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module supply loop power directly to 2-wire field transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-IE8C measures incoming current signals but does not distribute 24V DC loop power to active field devices. You must route your 2-wire transmitters through an external bulk power source or utilize a 1734-FPD Field Power Distributor module to energize the current loops before tying them into the module terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this analog input card an authentic factory-new component or a cleaned surplus unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product is 100% brand new, factory-original, and completely unused automation stock. It ships inside its authentic manufacturer packaging with unmarred backplane blade links, intact factory serialization labels, and untouched calibration parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I scale the 4-20mA signal into engineering units directly on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IE8C transmits data to the processor exclusively in signed integer format. You handle final engineering unit scaling—such as converting raw counts to PSI, GPM, or degrees—within your Logix5000 controller software program using the scaling (SCL) instruction or simple mathematical rungs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53478671483064,"sku":"1734-IE8C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-IE8C1.jpg?v=1779097641"},{"product_id":"allen-bradley-1734-acnr-point-i-o-controlnet-adapter-module","title":"Allen-Bradley 1734-ACNR POINT I\/O ControlNet Adapter Module","description":"\u003cp\u003eConfigured for distributed I\/O management within ControlNet network platforms, the \u003cstrong\u003eAllen-Bradley 1734-ACNR\u003c\/strong\u003e (\u003cstrong\u003e1734-ACNR\u003c\/strong\u003e ControlNet Adapter Module) provides direct physical execution of data exchange between the network medium and the POINTBus backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-ACNR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 1734 POINT I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e6 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.8 W at 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 1734-ACNR facilitates deterministic network communication by acting as the gateway between the ControlNet bus and connected POINT I\/O modules. It supports I\/O density scaling by allowing the connection of multiple terminal bases to a single adapter, optimizing backplane bus communication velocity. The module is compatible with standard firmware updates to maintain network synchronization and protocol integrity. By managing the backplane power distribution, the adapter ensures that individual I\/O modules receive consistent voltage levels, with reverse polarity protection included to prevent damage during installation or power surges.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1734-ACNR support hot-swapping of connected I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the POINT I\/O system supports Removal and Insertion Under Power (RIUP). However, always verify that the adapter and the associated backplane are in a non-fault state before removing any I\/O module to prevent interruption of the ControlNet bus traffic.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the adapter in a ControlNet configuration?\u003c\/p\u003e\n\u003cp\u003eA: The adapter serves as the coordinator for the POINT I\/O node. It translates the ControlNet protocol into the internal POINTBus protocol, allowing the controller to scan and manage the status of all digital and analog I\/O modules installed on the backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the DIN rail is securely mounted and grounded to the cabinet backplane to facilitate proper chassis ground connection for the adapter.\u003c\/li\u003e\n\u003cli\u003eSlide the adapter onto the DIN rail until the locking mechanism engages; confirm the module is flush with adjacent terminal bases to maintain backplane bus continuity.\u003c\/li\u003e\n\u003cli\u003eTerminate 24 VDC input power to the designated terminals, ensuring the wire gauge is sufficient to handle the 6 A inrush current and continuous current requirements.\u003c\/li\u003e\n\u003cli\u003eConnect the ControlNet media cable to the BNC or tap connector on the adapter, ensuring proper termination to prevent signal reflections on the network.\u003c\/li\u003e\n\u003cli\u003eVerify that the total current draw of all installed POINT I\/O modules does not exceed the 1000 mA capacity provided by the 1734-ACNR backplane bus power supply.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53537327513784,"sku":"1734-ACNR","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-ACNR.jpg?v=1780372558"},{"product_id":"allen-bradley-1734-fpd-point-i-o-field-potential-distributor","title":"Allen-Bradley 1734-FPD Point I\/O Field Potential Distributor","description":"\u003cp\u003eConfigured for power isolation and potential distribution in Point I\/O platforms, the \u003cstrong\u003eAllen-Bradley 1734-FPD\u003c\/strong\u003e (\u003cstrong\u003e1734-FPD\u003c\/strong\u003e Field Potential Distributor) provides direct physical and electrical execution of circuit segmentation across the POINTBus architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-FPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to manufacturing batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Point I\/O module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePass-through (10 A max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC, 12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 1734-FPD is installed between I\/O modules to create separate power groups within a single POINT I\/O assembly. It facilitates I\/O density scaling by allowing mixed voltage levels or isolated power segments while maintaining the continuous POINTBus communication path. The module is strictly a pass-through device for the internal bus; therefore, it does not support firmware flash compatibility independently, as it functions purely as an electrical distribution node within the system topology.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1734-FPD provide overcurrent protection for the field power circuit?\u003c\/p\u003e\n\u003cp\u003eA: No. The 1734-FPD is a distribution module. It does not contain internal fuses or overcurrent protection circuitry. External protection must be provided by the user in accordance with the system power requirements.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1734-FPD be used to isolate communication signals?\u003c\/p\u003e\n\u003cp\u003eA: No. The module only distributes field-side potential. The internal POINTBus communication signals pass through the module unimpeded and are not electrically isolated from the rest of the communication chain.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlacement:\u003c\/strong\u003e Position the 1734-FPD at the point in the POINT I\/O rack where a new power potential is required or where galvanic isolation between groups of I\/O modules is necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module onto a 35 mm DIN rail. Ensure the locking mechanism is fully engaged to maintain electrical contact with the POINTBus and adjacent terminal bases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field power to the distributor terminals. Use the specified 0.6 Nm screw torque to ensure reliable contact and prevent thermal degradation of the connection under continuous 10 A loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e While the module distributes field potential, ensure the common reference for the connected field power source is appropriately tied to the cabinet's protective earth ground to minimize potential differences and surge risks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53548995608760,"sku":"1734-FPD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-FPD.png?v=1780625525"},{"product_id":"allen-bradley-1734-vtm-point-i-o-voltage-terminal-module","title":"Allen-Bradley 1734-VTM Point I\/O Voltage Terminal Module","description":"\u003cp\u003eConfigured for voltage distribution in Point I\/O platforms, the \u003cstrong\u003eAllen-Bradley 1734-VTM\u003c\/strong\u003e (\u003cstrong\u003e1734-VTM\u003c\/strong\u003e Voltage Terminal Module) provides direct physical and electrical execution of 8-point voltage terminal access across POINTBus architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-VTM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to manufacturing batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Points\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Rating\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Range\u003c\/td\u003e\n\u003ctd\u003e10-28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 1734-VTM module operates as a terminal base expansion component, allowing for the direct connection of field devices to a centralized voltage potential. It enables efficient I\/O density scaling by providing 8 dedicated voltage terminals within a single slot width, reducing the need for external terminal blocks within the control cabinet. The internal bus structure maintains backplane bus communication integrity while the module serves as a passive distribution node. Firmware flash compatibility is not applicable, as the module contains no active logic or programmable components.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1734-VTM provide electrical isolation between the 8 voltage terminals?\u003c\/p\u003e\n\u003cp\u003eA: No. The 8 voltage points are internally commoned to distribute a shared potential. Users must ensure that the voltage level applied to the module is compatible with all connected field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be installed in a hot-swapped configuration?\u003c\/p\u003e\n\u003cp\u003eA: While the Point I\/O system supports hot-swapping for specific active modules, the 1734-VTM is a passive terminal block. It should be installed or removed only when the field power is isolated to prevent accidental short circuits or arc damage to the terminal contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module onto a 35 mm DIN rail. Ensure the terminal base is fully seated and the locking tab is engaged to provide mechanical stability and maintain contact with the POINTBus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize 22-14 AWG stranded or solid copper conductors. Tighten the screw clamp terminals to the recommended torque specifications to maintain a low-resistance connection and prevent wire pull-out under vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity and Voltage:\u003c\/strong\u003e Verify that the field voltage applied to the terminal points does not exceed the 240 VAC or 28.8 VDC rating. Confirm that the incoming power source is protected by appropriate external fuses or circuit breakers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e As a passive distribution component, ensure the connected field power common is referenced to the system ground where required by the specific application circuit design to maintain signal integrity and safety compliance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53549008584888,"sku":"1734-VTM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-VTM1.png?v=1780626370"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/allen-bradley-point-i-o.oembed","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}