{"title":"Bently Nevada 990 \u0026 991 Series","description":"\u003cp\u003eThis collection includes Bently Nevada 990 and 991 series vibration monitoring products designed for machinery protection and continuous condition monitoring.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-990-04-70-01-00-990-series-vibration-transmitter","title":"Bently Nevada 990-04-70-01-00 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eProduced in the United States by Bently Nevada, the\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e990-04-70-01-00\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered 990 Series Vibration Transmitter for industrial machinery condition monitoring. Pre-configured with application-specific specs for on-site adaptability, an optional Certificate Of Origin (COO) is available for this unit. It is exclusively integrated with Bently Nevada’s 3300 NSv Proximity Probe line for reliable vibration signal detection and transmission on critical industrial equipment.\u003c\/p\u003e\n\u003ch3\u003eCore Custom Configuration Options\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-scale range: \u003c\/strong\u003e0-4 mils pp (0-100 µm pp), configuration code 04\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem length: \u003c\/strong\u003e7.0 metres (23.0 feet), configuration code 70\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting type:\u003c\/strong\u003e 35 mm DIN rail clips, configuration code 01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency approval:\u003c\/strong\u003e No third-party certifications required, configuration code 00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInput\u003c\/span\u003e: 1 non-contacting 3300 NSv Proximity Probe + matching extension cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e:\u003c\/strong\u003e +12 Vdc to +35 Vdc, direct input at transmitter terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature: \u003c\/strong\u003e-35 °C to +85 °C (-31 °F to +185 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature: \u003c\/strong\u003e-51 °C to +100 °C (-60 °F to +212 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet weight: \u003c\/strong\u003e0.54 Kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: United States of America\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCOO\u003c\/span\u003e: Optional, available upon customer request\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e990-04-70-01-00\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003evibration transmitter is designed for continuous real-time vibration monitoring of rotating industrial equipment. It is widely applied to electric motors, centrifugal pumps, industrial compressors, gas turbines and heavy-duty gearboxes, and is suitable for manufacturing facilities, power generation plants, oil and gas processing sites and other heavy industrial settings where equipment reliability and uptime are critical.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhat sensing device is compatible with the 990-04-70-01-00?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis transmitter is only compatible with a single non-contacting 3300 NSv Proximity Probe, which must be used with a corresponding extension cable to ensure proper signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat mounting method is used for this vibration transmitter?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt is equipped with 35 mm DIN rail clips, enabling standard, tool-friendly mounting in industrial control cabinets and electrical enclosures for easy installation and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan I get a Certificate Of Origin for the 990-04-70-01-00?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eYes, a formal Certificate Of Origin (COO) is an available add-on for the\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e990-04-70-01-00\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003etransmitter, and can be provided upon your specific request.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52513549516984,"sku":"990-04-70-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-70-01-00__1.jpg?v=1769765243"},{"product_id":"bently-nevada-990-series-vibration-transmitter-990-04-70-02-00","title":"Bently Nevada 990 Series Vibration Transmitter – 990-04-70-02-00","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e990-04-70-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evibration transmitter from Bently Nevada is engineered for continuous, high-fidelity monitoring of machinery vibration in demanding industrial environments. Designed as part of the 990 Series, this device converts dynamic mechanical motion into a standardized analog signal for integration with plant-wide condition monitoring and protection systems.\u003c\/p\u003e\n\u003cp\u003eBuilt with robust electronics and housed in a compact, rugged enclosure, it ensures long-term reliability across extreme temperature conditions while maintaining signal integrity and measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (a Baker Hughes business)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e990-04-70-02-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: 990 Vibration Transmitter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e: Absolute vibration (velocity or displacement, depending on configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4–20 mA, linearly proportional to RMS or peak vibration amplitude\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: Typically 10 Hz to 1 kHz (configurable based on sensor input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: –35 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e: 18–30 VDC (loop-powered)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail or panel mount; compact footprint for confined spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Native integration with Bently Nevada 3500, System 1, and other Modbus\/TCP-enabled platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: IP66\/NEMA 4X (suitable for washdown and outdoor use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE, ATEX (optional), IECEx (optional, depending on variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbomachinery health monitoring (compressors, turbines, pumps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical asset protection in oil \u0026amp; gas, power generation, and chemical processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofitting legacy machinery with modern predictive maintenance capabilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Does the 990-04-70-02-00 require an external power supply?\u003c\/strong\u003e\u003cbr\u003eA: No—it is loop-powered via the 4–20 mA output circuit, requiring only 18–30 VDC from the monitoring system or PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it interface with non-Bently Nevada systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The 4–20 mA output is industry-standard and compatible with most DCS, PLC, and SCADA platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it differ from the 990-04-70-01-00?\u003c\/strong\u003e\u003cbr\u003eA: The “02” suffix typically denotes a velocity-based output scaled in mm\/s RMS, whereas the “01” variant may be configured for displacement (µm) or acceleration (g). Always verify calibration settings per application.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52513563508920,"sku":"990-04-70-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-70-01-00_3fdaff0c-4944-4e5f-b635-37547a528e9e.jpg?v=1769767600"},{"product_id":"bently-nevada-990-04-xx-01-00-990-vibration-transmitter","title":"Bently Nevada 990-04-XX-01-00 990 Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-04-XX-01-00 (MOD:147202-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance vibration transmitter designed for continuous machinery protection. This compact device integrates the proximity probe driver and signal conditioning into a single unit. It converts the complex signal from a proximity probe into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e, allowing direct integration into PLCs or DCS without requiring an external rack system. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanufactured in the USA.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990 series utilizes a specific coding structure to define mounting options and certifications. While the \"XX\" in your specific request denotes variable configurations, the standard structure for the 990-04 follows this logic:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (4-20mA Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRepresents a 0-4.0 mil (0-100 µm) pp range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefines ATEX, CSA, or IECEx hazardous area ratings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN rail mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBarrier Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo barrier required \/ Standard configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table highlights the core technical performance of the 990-04-XX-01-00:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe (3300 or 3300 XL 8mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA DC (Proportional to vibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 0.8 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 cm x 2.0 cm x 2.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.02 kg (including housing\/packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ultra-compact footprint eliminates the need for bulky monitoring racks. Engineers mount these units directly onto the machine skid or inside local junction boxes to save significant enclosure space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect PLC Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA loop-powered design simplifies wiring. You connect the transmitter directly to any standard analog input card, reducing installation costs and complex software configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990-04-XX-01-00 provides a separate buffered output. This allows technicians to connect portable data collectors for diagnostic analysis without interrupting the primary 4-20 mA safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliability in Extreme Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt with rugged internal circuitry, this transmitter handles the high-temperature and high-vibration conditions common in gas turbine and compressor applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require a separate Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-04-XX-01-00 functions as both the driver and the transmitter. It replaces the traditional Proximitor by outputting a 4-20 mA signal directly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat probe system is compatible with the 990-04?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates optimally with Bently Nevada 3300 or 3300 XL 8mm proximity probes. Ensure the system length (probe plus extension cable) matches the transmitter calibration (typically 5 or 9 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the output accuracy during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the \"Prox\" and \"COM\" terminals to measure the gap voltage. This allows you to set the mechanical gap of the probe accurately before relying on the 4-20 mA vibration reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit suitable for hazardous area installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, depending on the \"XX\" option code. Most 990 units carry North American (CSA) and European (ATEX\/IECEx) certifications for Zone 0, 1, and 2 environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224517894328,"sku":"990-04-XX-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001.png?v=1775182005"},{"product_id":"bently-nevada-990-04-xx-03-00-990-series-vibration-transmitter","title":"Bently Nevada 990-04-XX-03-00 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-04-XX-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates a Proximitor sensor and signal conditioner into a single, compact unit. This two-wire, loop-powered transmitter interfaces directly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv proximity probes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand extension cables. It converts radial vibration into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e, enabling direct machinery monitoring via a PLC or DCS without the need for a separate monitoring rack. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-04 series follows a specific configuration logic to match industrial requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Wire Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 4.0 mils pp (0 to 100 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple options (e.g., ATEX, CSA, IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail mount (Ruggedized clip)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBarrier Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard (No specialized barrier)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following parameters define the operational envelope of the 990-04-XX-03-00:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 NSv Proximity Probe \u0026amp; Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to peak-to-peak vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLoop-powered (12 to 35 Vdc).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.43 kg (0.95 lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 300 meters (1,000 feet) of field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of External Drivers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated design combines the Proximitor and transmitter. This reduces component count, simplifies the bill of materials, and lowers potential failure points in the signal chain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Tight Spaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe small form factor allows for installation in high-density junction boxes or directly on the machine skid where space remains at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter conditions the high-frequency eddy current signal into a robust 4-20 mA loop locally. This protects the data integrity from electromagnetic interference (EMI) during long-distance transmission to the control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Commissioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features a non-interacting zero and span adjustment. Maintenance teams calibrate the loop quickly without the iterative \"seesaw\" adjustments required by older analog models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 990-04-XX-03-00 with a standard 3300 XL 8mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific model (03 mounting) specifically targets the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv (Narrow Side View)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobe system. The NSv system addresses applications with small target areas or confined spaces where standard probes cannot function due to side-viewing interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the probe gap during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter includes a \"Gap\" terminal. You can connect a standard digital multimeter (DVM) to measure the voltage, ensuring the probe sits within the linear range before locking the mounting hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit require a specific orientation when mounting on a DIN rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 990-04-XX-03-00 utilizes a rugged 35mm DIN rail clip. While it functions in any orientation, we recommend vertical mounting in high-vibration environments to ensure maximum clip retention and heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or surplus unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We guarantee this product is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original Bently Nevada stock\u003c\/strong\u003e, shipped in factory packaging with full manufacturer traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224588574904,"sku":"990-04-XX-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-00_c545002a-2d71-4ddf-9b81-682f7039f2cb.png?v=1775182225"},{"product_id":"990-05-50-02-01-bently-nevada-990-series-vibration-transmitter","title":"990-05-50-02-01 | Bently Nevada 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-50-02-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides continuous machinery protection by converting vibration data into a robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC signal\u003c\/strong\u003e. This two-wire, loop-powered transmitter specifically interfaces with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv Proximity Probes\u003c\/strong\u003e, making it the primary choice for monitoring centrifugal air compressors or other machinery with small shaft diameters. We offer this unit as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory component\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum system uptime.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-50-02-01 configuration utilizes the following engineering logic:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils pp (0 to 125 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA Division 2 (Non-Incendive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter conditions signals with high precision for direct PLC\/DCS integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 NSv Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA (proportional to peak-to-peak vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Hz to 1,000 Hz (600 to 60,000 cpm) ±10%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCalibrated for a 5-meter total electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 35 mm DIN rail installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA Division 2 for hazardous area safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 0.43 kg (unit only).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Contained Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990-05-50-02-01 eliminates the need for external Proximitor units. This reduces the total footprint in control cabinets and simplifies field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter includes a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTest Input\u003c\/strong\u003e. Maintenance personnel can inject a signal from a function generator to verify the 4-20 mA loop integrity without dismantling the probe assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Narrow Targets:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for the 3300 NSv system, this transmitter maintains signal linearity even when monitoring shafts with small diameters or when the probe faces restricted side clearances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CSA Division 2 approval ensures safe operation in environments containing volatile gases, protecting your facility against ignition risks in standard industrial processing zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a 9-meter cable with this specific transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"50\" option code designates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5-meter system length\u003c\/strong\u003e. You must use a combination of probe and extension cable that totals 5 meters to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this transmitter handle power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a loop-powered device, the transmitter signal drops below 3.6 mA or to 0 mA upon power failure, allowing the connected PLC\/DCS to trigger a \"Sensor Fault\" or \"Not OK\" alarm immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs any specialized software required for calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-05-50-02-01 provides a linear 4-20 mA output. You simply scale the analog input on your control system to match the 0-5 mils pp range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit come with a warranty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since we supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware, the product includes the standard manufacturer's assurance of quality and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224588902584,"sku":"990-05-50-02-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_e5e28c55-e32c-431f-b4d4-290df53194cb.png?v=1775182365"},{"product_id":"990-series-bently-nevada-990-05-70-01-00-vibration-transmitter","title":"990 Series | Bently Nevada 990-05-70-01-00 Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-70-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a specialized 2-wire vibration transmitter that integrates Proximitor sensor functionalities into a single, compact housing. It simplifies machinery monitoring by outputting a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC signal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproportional to radial vibration. Designed specifically for integration with PLC and DCS architectures, this unit eliminates the requirement for centralized monitoring racks. We provide this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e, manufactured in the USA.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-70-01-00 utilizes the following technical configuration:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Loop-Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-5 mils pp (0-125 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 meters (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot required \/ Standard version\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe unit converts complex eddy current signals into precise analog data:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to peak-to-peak vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 125 μm (0 to 5 mils) peak-to-peak.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFixed for 7.0-meter probe\/cable combinations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc (Loop-powered).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure DIN rail interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Field Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter installs near the machine skid, reducing the need for long, expensive coaxial cable runs back to a control room. The robust 4-20 mA signal travels over standard twisted-pair wiring with high resistance to electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Reach with 7m Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"70\" system length option provides additional flexibility during installation. It allows engineers to route extension cables through complex conduit paths or larger machine frames where standard 5-meter systems fall short.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Cabinet Utilization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 35 mm DIN rail clips facilitate rapid high-density mounting. This design maximizes enclosure space, allowing multiple vibration points to be monitored from a single compact junction box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated test input allows technicians to verify loop performance using a function generator. This feature permits full loop checks from the transmitter to the DCS without disturbing the proximity probe installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this 7-meter transmitter with a 5-meter probe\/cable set?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The internal circuitry is calibrated for the specific impedance and electrical length of a 7.0-meter system. Using a different length will cause significant measurement errors and non-linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support 3300 XL 8mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this transmitter typically interfaces with Bently Nevada 3300 XL 8mm probes and extension cables, provided the total electrical length equals 7.0 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe signal is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter features an \"OK\" circuit logic. If the probe signal disappears or the cable breaks, the 4-20 mA output typically drops below 3.6 mA, signaling a \"Not OK\" status to your control system to prevent false vibration alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product used or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely not. We only supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand new, original factory units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure the integrity of your machinery protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224589721784,"sku":"990-05-70-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_27036fa9-3bf6-40e6-8c9e-be143b031f4a.png?v=1775182498"},{"product_id":"990-05-70-01-01-bently-nevada-990-series-vibration-transmitter","title":"990-05-70-01-01 | Bently Nevada | 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-70-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision, two-wire vibration transmitter that bridges the gap between proximity probes and control systems. It integrates the driver and signal conditioner into one compact module, converting radial vibration into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e. This model supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7.0-meter system length\u003c\/strong\u003e, allowing for flexible field wiring without sacrificing signal accuracy. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original factory equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-70-01-01 follows a modular configuration to meet specific industrial requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Loop-Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-5 mils pp (0-125 µm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 meters (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA\/NRTL\/C (Class I, Div 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe transmitter conditions signals for high-reliability machinery monitoring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 or 3300 XL 8mm Proximity Probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Linear to peak-to-peak vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCalibrated for exactly 7.0 meters of total electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Hz to 1,000 Hz (600 to 60,000 cpm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRackless Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a 4-20 mA signal directly, this transmitter removes the need for expensive rack-based monitoring systems. Engineers connect the device directly to any standard analog input card on a PLC or DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConverting high-frequency eddy current signals into a 4-20 mA current loop locally prevents signal degradation over long distances. This ensures high noise immunity in environments with heavy electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 7-meter system length provides the necessary reach for large machinery where the probe and the transmitter must reside in separate locations or within complex enclosure layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Field Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features a buffered voltage output. Maintenance personnel connect a portable data collector to this port to analyze vibration waveforms in real-time without interrupting the primary safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I use a 5-meter probe with this 7-meter transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system will lose calibration accuracy. The 990-05-70-01-01 requires a combined probe and extension cable length of exactly 7.0 meters to maintain the specified linearity and scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-05-70-01-01 is loop-powered. It draws its required operating voltage directly from the 4-20 mA signal loop provided by the control system (PLC\/DCS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the \"OK\" status of the sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the transmitter detects a probe fault or cable break, the 4-20 mA signal typically drops below 3.6 mA. Your control system should be configured to recognize this low current as a \"Not OK\" status rather than a vibration alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product ready for immediate installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit shipped in original packaging, fully tested and calibrated according to Bently Nevada factory standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224590508216,"sku":"990-05-70-01-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_0e555b8a-4612-498b-bca4-6b146dba76dc.png?v=1775182831"},{"product_id":"bently-nevada-990-05-70-02-00-990-series-vibration-transmitter","title":"Bently Nevada 990-05-70-02-00 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-70-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a streamlined solution for machinery protection by converting radial vibration into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC signal\u003c\/strong\u003e. Primarily designed for OEMs of centrifugal air compressors, small pumps, and motors, this transmitter integrates the proximitor and signal conditioner into a single unit. It eliminates the need for external racks, allowing direct input into a PLC or DCS. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-70-02-00 model utilizes a specific configuration to match 7-meter probe systems:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Loop-Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils pp (0 to 125 µm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 meters (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulkhead Mounting (Non-DIN Rail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Approvals Required \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers precise signal conditioning under extreme industrial conditions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp (Transmitter):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp (Probe):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-52°C to +177°C (-62°F to +351°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Tip Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePolyphenylene sulfide (PPS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Case Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAISI 303 or 304 Stainless Steel (SST).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75Ω coaxial, Fluoroethylene Propylene (FEP) insulated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.43 kg (Transmitter only); 0.82 kg (Typical system total).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% condensing (non-submerged).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless OEM Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA loop-powered design reduces the complexity of machinery control systems. This allows manufacturers of small pumps and fans to implement vibration monitoring without installing high-cost, specialized hardware racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe probe utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePPS tip\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStainless Steel casing\u003c\/strong\u003e, which resists chemical corrosion and high-temperature exposure. This ensures long-term stability when installed inside high-speed centrifugal compressors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Tensile Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe interface between the probe case and lead withstands up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e222 N (50 lbf)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof tension. This prevents signal loss during installation through tight conduit paths or areas with significant physical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect-to-DCS Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy conditioning the signal locally, the 990-05-70-02-00 minimizes the risk of signal interference over long field wiring runs. The low-impedance 4-20 mA loop maintains high data integrity in noisy electrical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a 5-meter probe with this 990-05-70-02-00 transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This transmitter is calibrated specifically for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7.0-meter system length\u003c\/strong\u003e. Using a 5-meter cable will result in a scale factor error and inaccurate vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is loop-powered, typically drawing power from the 24V DC supply of the PLC or DCS analog input card. You do not need a separate power source for the transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the Bulkhead Mounting (02 option)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bulkhead mounting option provides a flat-surface securement method, ideal for mounting directly onto machine skids or inside custom junction boxes where DIN rails are not available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the probe included in this part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 990-05-70-02-00 refers to the transmitter unit. You must order the 3300 or 3300 XL 8mm probe and extension cable separately, ensuring the total length matches the 7.0-meter requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224598044856,"sku":"990-05-70-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-00_079c58ca-aacb-4947-91ce-6d7e53fd590d.png?v=1775183079"},{"product_id":"bently-nevada-990-series-vibration-transmitter-990-05-70-03-00","title":"Bently Nevada 990 Series Vibration Transmitter | 990-05-70-03-00","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-70-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision, loop-powered vibration transmitter designed for direct integration with industrial control systems. It accepts signals from a proximity probe and extension cable, converting the complex eddy current data into a linear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproportional to peak-to-peak vibration amplitude. This \"rackless\" solution enables critical machinery monitoring without the cost or footprint of a dedicated monitoring rack. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-70-03-00 configuration follows Bently Nevada's modular logic for 7-meter systems:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils pp (0 to 125 µm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 meters (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips (High-density)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Agency Approvals Required \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter conditions signals with high accuracy for 24VDC loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 XL 8mm Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 125 µm (0 to 5 mils) peak-to-peak.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProximity Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.25 to 1.65 mm (10 to 65 mils).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24VDC loop-powered (Two-wire).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35mm DIN rail clips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.90 kg (Approximate system weight).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Proximitor Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter combines the probe driver and signal conditioner into a single module. This eliminates the need for external drivers and reduces the number of termination points in your junction box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy converting the high-frequency probe signal to a 4-20 mA current loop locally, the unit minimizes electromagnetic interference (EMI) risks. This ensures clean data transmission over long distances to the PLC\/DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for 7-Meter Runs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"70\" calibration accommodates larger machines or complex cable routing where standard 5-meter cables fall short. It maintains full signal linearity across the entire 7-meter electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimple Maintenance Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990-05-70-03-00 provides a buffered voltage output. Technicians connect a portable analyzer directly to the transmitter to view the raw vibration waveform without disconnecting any wiring or interrupting the control loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this transmitter with a 3300 XL 5-meter probe?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This model is factory-calibrated for a 7.0-meter system. Using a 5.0-meter probe and cable will cause significant scale factor errors and inaccurate vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 990-05-70-03-00 require an external power supply?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit is a two-wire, loop-powered device. It draws the necessary power from the 24VDC supply provided by your PLC or DCS analog input card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe cable disconnects?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter includes an \"OK\" circuit logic. Upon cable failure or probe fault, the 4-20 mA output typically drops below 3.6 mA, allowing the control system to distinguish between a sensor failure and a high-vibration event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product refurbished or \"new-surplus\"?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand new, factory-original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware. Each unit ships in its original manufacturer packaging with full traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224603254968,"sku":"990-05-70-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_608df7a9-3b99-4721-b5a4-f8e8dc7d36a0.png?v=1775183219"},{"product_id":"990-05-xx-03-05-990-series-vibration-transmitter-bently-nevada","title":"990-05-XX-03-05 990 Series Vibration Transmitter | Bently Nevada","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-XX-03-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance, two-wire vibration transmitter engineered for critical machinery protection. It accepts signals from proximity probes and converts them into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproportional to peak-to-peak vibration. This specific configuration includes high-level agency approvals, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX, CSA, and ABS maritime certifications\u003c\/strong\u003e, making it the primary choice for offshore, marine, and hazardous area applications. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-XX-03-05 configuration utilizes the following technical coding:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils (0 to 125 µm) peak-to-peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 (5.0 meters) or 70 (7.0 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips and mounting screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA Div 2, ATEX Zone 0\/2, and ABS Maritime Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers precise signal conditioning for modern control architectures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA loop (1,000 Ω maximum loop resistance).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 Hz to 6,000 Hz ±0.3 dB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires +12 to +35 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 mm to 1.75 mm (20 mils to 55 mils).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75Ω coaxial, Fluoroethylene Propylene (FEP) insulated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTensile Strength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e222 N (50 lbf) maximum probe case to lead tension.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Certified Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"05\" approval suffix enables global deployment. It satisfies stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements for explosive atmospheres and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards for marine vessels and offshore platforms, reducing the need for localized inventory variants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-interacting external adjustments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor zero and span. Technicians calibrate the loop quickly without the signal \"drift\" common in lower-quality analog transmitters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Impedance Loop Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1,000 Ω of loop resistance\u003c\/strong\u003e, this unit maintains signal accuracy even over long field wiring runs to remote control rooms or high-input-impedance PLC cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFEP-insulated coaxial cables resist chemical exposure and moisture. The transmitter maintains high frequency-response linearity (±0.3 dB), ensuring that the control system receives a true representation of the machine's vibration profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the ABS maritime approval on this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ABS (American Bureau of Shipping) certification verifies that the transmitter meets specific vibration, environmental, and electrical standards required for use on ships and offshore drilling rigs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I adjust the vibration range in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 0-5 mils full-scale range is factory-set. However, you can use the non-interacting zero and span adjustments to fine-tune the 4-20 mA output to match your control system's scaling precisely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose between the 50 and 70 \"XX\" options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must match the \"XX\" code to your existing probe and extension cable length. A \"50\" transmitter requires a 5-meter total system length, while a \"70\" requires a 7-meter system. Mixing lengths will cause severe measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit come in original packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We only sell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware in original factory packaging, complete with all necessary documentation and traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224645591224,"sku":"990-05-XX-03-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_c4b33cb9-c238-41d2-a7bc-ee7a494c9760.png?v=1775183478"},{"product_id":"bently-nevada-990-05-xx-03-cn-990-series-vibration-transmitter-4-20ma","title":"Bently Nevada 990-05-XX-03-CN 990 Series Vibration Transmitter | 4-20mA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-XX-03-CN (104M1359-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core component for machinery condition monitoring, converting radial vibration into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e. This loop-powered transmitter eliminates the need for external Proximitor units or rack-based monitoring, allowing direct integration into a PLC or DCS. This specific CN-variant meets localized industrial standards while maintaining the high-precision eddy current measurement technology Bently Nevada pioneered. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanufactured in the USA.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-XX-03-CN configuration identifies the following technical specifications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils pp (0 to 125 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMatches 5.0m (50) or 7.0m (70) cable lengths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips and mounting screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegional specialized industrial certification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter provides high-linearity signal conditioning for industrial rotating assets:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 5 mils peak-to-peak.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.2 cm x 12.4 cm x 12.6 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 kg (Unit only).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc (Loop-powered).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Device:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 or 3300 XL Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReduced System Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ultra-slim 2.2 cm width allows for high-density mounting within local junction boxes. Engineers maximize cabinet space by utilizing the integrated 35 mm DIN rail clips for rapid installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Field-to-Controller Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a 4-20 mA current loop, the 990-05-XX-03-CN removes the complexity of specialized vibration monitoring hardware. It drives the signal over standard twisted-pair wiring, ensuring high noise immunity across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Output Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter includes a separate buffered voltage signal. This allows maintenance teams to connect portable vibration analyzers for diagnostic \"deep dives\" without disconnecting the primary safety loop or interrupting the 4-20 mA signal to the DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Asset Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter provides real-time data for centrifugal compressors and pumps. Its fast response time ensures the control system detects sudden vibration excursions immediately, preventing catastrophic machinery failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter replace the 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, in applications where you only require a 4-20 mA signal. The 990 transmitter combines the driver and signal conditioner, so you do not need a separate Proximitor to send vibration data to your PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the probe gap during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect a multimeter to the \"Prox\" and \"COM\" terminals. This measures the DC gap voltage, allowing you to position the probe at the precise electrical center of the linear range before finalizing the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system length must I use with the \"XX\" code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must match the transmitter to your cable length. If the code is 50, use a 5-meter probe\/cable system; if 70, use a 7-meter system. Mixing lengths will invalidate the calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit an authentic Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee the 990-05-XX-03-CN is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and genuine\u003c\/strong\u003e. Each unit undergoes factory calibration in the USA to ensure full compliance with machinery protection standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224654897336,"sku":"990-05-XX-03-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_bc11328d-7d81-4b2a-a1e7-1c43338b731d.png?v=1775183988"},{"product_id":"990-08-xx-01-00-bently-nevada-990-series-vibration-transmitter","title":"990-08-XX-01-00 | Bently Nevada 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-08-XX-01-00 (MOD:283278-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides continuous machinery protection by converting radial vibration into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC signal\u003c\/strong\u003e. This loop-powered transmitter integrates the Proximitor sensor functionality and signal conditioning into a single, compact housing. It eliminates the requirement for external racks, allowing direct connection to a PLC or DCS analog input card. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanufactured in the USA.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-08 configuration identifies the specific measurement and mounting parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 8 mils pp (0 to 200 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMatches 5.0m (50) or 7.0m (70) probe\/cable lengths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard \/ No Agency Approvals Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter conditions signals with high linearity for critical rotating assets:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-Scale Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 8 mils peak-to-peak (200 μm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.5 cm x 22.4 cm x 3.3 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 kg (Unit only).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 or 3300 XL Proximity Probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc (Loop-powered).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for High Vibration Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0-8 mils full-scale range accommodates machinery with higher vibration thresholds, providing sufficient headroom for monitoring larger centrifugal compressors and fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Signal Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter converts the complex eddy current signal to a robust 4-20 mA current loop locally. This protects data integrity from electromagnetic interference (EMI) during transmission to remote control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Output Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes a separate buffered voltage signal. Maintenance teams connect portable data collectors directly to this port for real-time wave-form analysis without interrupting the primary safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 35 mm DIN rail clip mounting enables high-density installation within local junction boxes. The slim profile saves significant enclosure space compared to traditional rack-mounted monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require a separate Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-08-XX-01-00 combines the probe driver and the signal conditioner. It replaces the Proximitor by outputting a 4-20 mA signal directly to your control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the probe gap during setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter provides \"Prox\" and \"COM\" terminals. Use a digital multimeter to measure the DC gap voltage. This ensures the probe resides in the center of the linear range before you finalized the mechanical mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I use a 5-meter probe with a 7-meter (XX=70) transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system will lose calibration. You must match the transmitter’s \"XX\" code to the total electrical length of your probe and extension cable to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee the 990-08-XX-01-00 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original factory stock\u003c\/strong\u003e. Every unit comes in original packaging with full manufacturer traceability from the USA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224660107448,"sku":"990-08-XX-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_789ad371-b986-414e-8d9e-66f55ba078cc.png?v=1775184287"},{"product_id":"990-08-xx-03-00-bently-nevada-990-series-vibration-transmitter","title":"990-08-XX-03-00 | Bently Nevada 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-08-XX-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates a proximity probe driver and signal conditioner into a single, compact module. It converts radial vibration data into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e, enabling direct machinery monitoring via a PLC or DCS without requiring an external monitor rack. This unit specifically accepts inputs from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv proximity probes\u003c\/strong\u003e, making it the primary choice for monitoring shafts with small diameters or restricted side clearances. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-08 series configuration follows a modular logic to match specific system requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-8 mils pp (0-200 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMatches 5.0m (50) or 7.0m (70) electrical lengths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN-rail clips and bulkhead mounting screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo approvals required \/ Standard configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 990-08-XX-03-00 conditions signals with high precision for industrial rotating assets:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 3300 NSv proximity probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response (± 10%):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Hz to 1 kHz (600 cpm to 60 kcpm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response (± 3 dB):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 Hz to 10 kHz (60 cpm to 600 kcpm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.2 mV\/m\/s² (100 mV\/g) ± 20%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both 35mm DIN-rail and bulkhead screw mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc (Loop-powered).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Restricted Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for use with the 3300 NSv (Narrow Side View) probe, this transmitter maintains signal linearity in tight mechanical spaces where standard probes suffer from \"side-view\" interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRackless Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe loop-powered design removes the need for centralized monitoring racks. Engineers mount the transmitter directly in local junction boxes near the machine skid, reducing cabling costs and cabinet footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter conditions the sensitive high-frequency eddy current signal into a robust 4-20 mA current loop locally. This ensures data integrity over long distances, even in environments with heavy electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Mounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"03\" option provides both DIN-rail clips for rapid cabinet installation and bulkhead screws for high-vibration mounting scenarios where extra physical security is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a standard 3300 XL 8mm probe with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This model specifically matches the impedance and calibration of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e. Using a standard 8mm probe will cause significant measurement errors and non-linear output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the probe gap during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter features \"Prox\" and \"COM\" terminals. Connect a digital multimeter to these points to measure the DC gap voltage. This allows you to set the mechanical gap accurately before finalizing the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe cable breaks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter includes an \"OK\" circuit logic. If the system detects a probe fault or cable rupture, the 4-20 mA signal drops below 3.6 mA. This allows your PLC\/DCS to identify a sensor fault rather than triggering a false high-vibration alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit refurbished or new surplus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNeither. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, factory-original Bently Nevada stock\u003c\/strong\u003e, shipped in original packaging with full manufacturer traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224662761656,"sku":"990-08-xx-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_0acc42e5-e433-4f57-990e-5329be53115b.png?v=1775184569"},{"product_id":"990-04-50-02-00-bently-nevada-990-series-vibration-transmitter","title":"990-04-50-02-00 | Bently Nevada 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-04-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision, two-wire vibration transmitter designed for continuous machinery protection. It accepts signals from a proximity probe and extension cable, converting the complex eddy current data into a linear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproportional to peak-to-peak vibration. This \"rackless\" solution enables critical monitoring of centrifugal compressors, pumps, and fans without the cost or footprint of a dedicated monitoring rack. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-50-02-00 configuration utilizes Bently Nevada’s modular logic for 5-meter systems:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 4 mils pp (0 to 100 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulkhead Mounting (Screw-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Agency Approvals Required \/ Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter conditions signals with high accuracy for 24VDC loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-Scale Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 4 mils peak-to-peak (100 μm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFixed for 5.0-meter probe\/cable combinations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 or 3300 XL 8mm Proximity Probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc (Loop-powered).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.43 kg (0.9 lb) typical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless PLC\/DCS Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter converts raw proximity signals into a standard 4-20 mA current loop locally. This allows engineers to connect the device directly to any standard analog input card, eliminating the need for specialized vibration monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Bulkhead Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"02\" mounting option provides a flat-surface, screw-down interface. This is ideal for mounting the transmitter directly onto machine skids or inside custom junction boxes where DIN rails are not available or where high-vibration security is paramount.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy conditioning the signal at the source, the 990-04-50-02-00 protects data integrity from electromagnetic interference (EMI) during long-distance transmission to the control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Buffered Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit includes a separate buffered voltage signal. Maintenance personnel connect portable data collectors directly to the transmitter to analyze vibration waveforms in real-time without interrupting the primary 4-20 mA safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a 7-meter extension cable with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-04-50-02-00 is factory-calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter total system length\u003c\/strong\u003e. Using a 7-meter cable will result in a scale factor error and inaccurate vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990 series integrates the Proximitor driver and transmitter into a single module. It replaces the traditional Proximitor for 4-20 mA applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe gap is set incorrectly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter provides \"Prox\" and \"COM\" terminals. You should measure the DC gap voltage with a multimeter during installation to ensure the probe is positioned in the center of its linear range (typically -10V DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein original Bently Nevada packaging with full manufacturer traceability and quality assurance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224665940152,"sku":"990-04-50-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-00_ca697c44-5d39-4574-a673-c963943570ad.png?v=1775184717"},{"product_id":"bently-nevada-990-05-50-01-cn-990-series-vibration-transmitter","title":"Bently Nevada 990-05-50-01-CN 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-50-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision, two-wire vibration transmitter designed for immediate machinery health assessment. It accepts input from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv proximity probes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand converts the signal into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproportional to peak-to-peak vibration. This compact, loop-powered device eliminates the need for external Proximitor units, allowing direct integration into a PLC or DCS for early detection of potential machinery faults. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-50-01-CN follows a specific configuration for 5-meter monitoring systems:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Integrated Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils pp (0 to 125 μm pp)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegional specialized industrial certification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe transmitter utilizes rugged materials to ensure high-linearity data in industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to vibration amplitude).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300 NSv Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Tip Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePolyphenylene sulfide (PPS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCase Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAISI 303 or 304 Stainless Steel (SST).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFluoroethylene propylene (FEP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% condensing (potted construction).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.82 kg (Typical system weight).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Restricted Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter specifically interfaces with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv (Narrow Side View)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. It maintains measurement accuracy on shafts with small diameters or in confined spaces where standard probes suffer from side-view interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe potted construction protects internal circuitry from high-humidity and condensing environments. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST housing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePPS tip\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eresist chemical corrosion, ensuring long-term durability when mounted directly on bearing housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990-05-50-01-CN supports both DIN-rail mounting for cabinet efficiency and bulkhead mounting for secure field installation. The two-wire, loop-powered design reduces wiring costs and simplifies the overall architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FEP-insulated 75Ω coaxial cable maintains signal purity across the 5-meter system length. The transmitter resists electromagnetic interference (EMI), delivering a stable 4-20 mA signal over long distances to the control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-05-50-01-CN is loop-powered. It draws its required operating voltage directly from the 4-20 mA signal loop provided by the PLC or DCS analog input card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the probe gap during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter includes dedicated terminals to measure the DC gap voltage. Use a digital multimeter to confirm the probe resides in the center of its linear range before finalized mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum tensile strength of the probe lead?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe case to probe lead connection withstands a maximum tensile force of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e222 N (50 lbf)\u003c\/strong\u003e, preventing damage during cable routing through tight conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this unit with a standard 8mm 3300 XL probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This model is factory-calibrated for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobe system. Using a standard 8mm probe will lead to significant calibration errors and inaccurate vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224668463288,"sku":"990-05-50-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_cb999cae-0176-48d0-8c35-e02f17acabe0.png?v=1775184832"},{"product_id":"bently-nevada-990-08-xx-01-cn-3300-nsv-proximity-transmitter","title":"Bently Nevada 990-08-XX-01-CN 3300 NSv Proximity Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-08-XX-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision vibration transmitter within the 3300 NSv series. This device interfaces directly with non-contacting proximity probes to monitor radial vibration or axial position on rotating machinery. It converts the complex eddy current signal into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA current loop output\u003c\/strong\u003e, allowing operators to integrate critical vibration data directly into a DCS or PLC without requiring a dedicated rack-based monitor. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum plant safety and sensor longevity.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-08-XX-01-CN follows a specific configuration logic to match your industrial requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Proximity Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5.0 mils (127 µm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecified by client (e.g., DIN rail or Panel mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Approvals (ATEX\/IECEx\/CSA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegional Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecifically configured for the Chinese industrial market\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers high-fidelity data even in electrically noisy environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires +12 to +35 Vdc input at the transmitter terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 to 5.0 mils (12.7 to 127 microns).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA current loop (Proportional to vibration\/position).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 12,000 cpm (0 to 200 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates reliably from -50°C to 120°C (-58°F to 248°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e23 mA typical to protect downstream circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-08-XX-01-CN solves specific installation and environmental challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output eliminates the need for expensive monitoring racks. You can wire the transmitter directly into your existing control system, saving significant cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust design withstands temperatures up to 120°C. This allows for installation in close proximity to gas turbines or steam valves where standard electronics often fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Shaft Specialists:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard proximity systems, the NSv (Narrow Side View) technology excels in tight geometries. It minimizes side-view interference and allows for accurate measurement on shafts with diameters smaller than 50 mm (2 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990 series arrives factory-calibrated for the 3300 NSv probe system, reducing commissioning time and eliminating the need for field adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with standard 3300 XL 8mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-08-XX-01-CN specifically requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e. Using standard 3300 XL probes will result in incorrect scale factors and inaccurate vibration readings due to different coil characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter provide a buffered output for diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the primary output is 4-20 mA, the unit includes a dynamic signal output. Technicians can connect portable vibration analyzers (like the Scout or VB series) to the BNC terminal to perform spectrum analysis and detailed fault diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply do I need for a multi-transmitter setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach transmitter draws a maximum of approximately 23 mA. For multiple units, ensure your power supply provides between +12 and +35 Vdc with enough total amperage to cover the combined draw of all transmitters on the loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or surplus item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware. Each unit ships in original packaging with the manufacturer’s certification of compliance, ensuring the full lifespan of the internal capacitors and circuitry.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224669282488,"sku":"990-08-XX-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_cad98481-fae6-42c7-a1dc-16e545de9f37.png?v=1775185062"},{"product_id":"990-05-70-03-05-3300-xl-vibration-transmitter-bently-nevada","title":"990-05-70-03-05 | 3300 XL Vibration Transmitter | Bently Nevada","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-08-XX-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision vibration transmitter within the 3300 NSv series. This device interfaces directly with non-contacting proximity probes to monitor radial vibration or axial position on rotating machinery. It converts the complex eddy current signal into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA current loop output\u003c\/strong\u003e, allowing operators to integrate critical vibration data directly into a DCS or PLC without requiring a dedicated rack-based monitor. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum plant safety and sensor longevity.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-08-XX-01-CN follows a specific configuration logic to match your industrial requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Proximity Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5.0 mils (127 µm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecified by client (e.g., DIN rail or Panel mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Approvals (ATEX\/IECEx\/CSA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegional Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecifically configured for the Chinese industrial market\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers high-fidelity data even in electrically noisy environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires +12 to +35 Vdc input at the transmitter terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 to 5.0 mils (12.7 to 127 microns).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA current loop (Proportional to vibration\/position).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 12,000 cpm (0 to 200 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates reliably from -50°C to 120°C (-58°F to 248°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e23 mA typical to protect downstream circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-08-XX-01-CN solves specific installation and environmental challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output eliminates the need for expensive monitoring racks. You can wire the transmitter directly into your existing control system, saving significant cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust design withstands temperatures up to 120°C. This allows for installation in close proximity to gas turbines or steam valves where standard electronics often fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Shaft Specialists:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard proximity systems, the NSv (Narrow Side View) technology excels in tight geometries. It minimizes side-view interference and allows for accurate measurement on shafts with diameters smaller than 50 mm (2 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990 series arrives factory-calibrated for the 3300 NSv probe system, reducing commissioning time and eliminating the need for field adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with standard 3300 XL 8mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-08-XX-01-CN specifically requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e. Using standard 3300 XL probes will result in incorrect scale factors and inaccurate vibration readings due to different coil characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter provide a buffered output for diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the primary output is 4-20 mA, the unit includes a dynamic signal output. Technicians can connect portable vibration analyzers (like the Scout or VB series) to the BNC terminal to perform spectrum analysis and detailed fault diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply do I need for a multi-transmitter setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach transmitter draws a maximum of approximately 23 mA. For multiple units, ensure your power supply provides between +12 and +35 Vdc with enough total amperage to cover the combined draw of all transmitters on the loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or surplus item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware. Each unit ships in original packaging with the manufacturer’s certification of compliance, ensuring the full lifespan of the internal capacitors and circuitry.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224670068920,"sku":"990-05-70-03-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-002_a497c88a-53a9-4866-9242-1701e81f56dd.png?v=1775185170"},{"product_id":"bently-nevada-990-05-50-02-00-2-wire-vibration-transmitter-3300-xl","title":"Bently Nevada 990-05-50-02-00 2-Wire Vibration Transmitter | 3300 XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance, 2-wire vibration transmitter designed for seamless integration with existing control systems. This device consolidates the signal conditioning of an eddy current proximity probe into a linear 4-20 mA output. By utilizing a loop-powered architecture, it simplifies field wiring while providing continuous machinery health data to PLCs or DCS. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak performance for your critical rotating assets.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990 series follows a precise modular configuration to match specific probe systems and environmental requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils peak-to-peak (127 µm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/CSA Hazardous Area Certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers laboratory-grade precision in a rugged industrial form factor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2-Wire 4-20 mA loop current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 5 mils (0 to 127 microns).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 cm x 7.5 cm x 5.2 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.44 KG.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts loop voltage from +12 to +35 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfaces with 3300 XL 8mm proximity probes and extension cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-50-02-00 addresses specific industrial installation challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimized Wiring Complexity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2-wire design reduces cable costs and installation time. It draws power directly from the 4-20 mA loop, eliminating the need for separate power conductors in the field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 10 cm footprint allows for high-density mounting. Engineers can fit multiple transmitters within a single small junction box near the machine train, reducing the distance of sensitive raw-signal cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-Site Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its simple 2-wire interface, the unit features a buffered \"Prox Out\" terminal. This allows vibration analysts to plug in a portable data collector and view the raw orbit or time-base waveform without disconnecting any wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround Loop Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter’s internal circuitry isolates the signal to prevent ground loop interference, a common issue in large industrial plants that causes false alarms or erratic readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support 7-meter or 9-meter cable systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"-00\" suffix designates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter system length\u003c\/strong\u003e. You must use a probe and extension cable that combined equal 5.0 meters. Using a different length will result in significant calibration errors and non-linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe signal is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter incorporates a \"NOT OK\" status. If the probe or cable fails (open or short circuit), the loop current drops below 3.6 mA. This allows your PLC to distinguish between \"Zero Vibration\" and a \"System Fault,\" preventing false trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this transmitter directly on the machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the unit is rugged, we recommend mounting it in a NEMA 4X or IP65 rated junction box. This protects the terminal connections from oil, moisture, and extreme vibration, ensuring the 100% brand-new circuitry reaches its maximum service life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We only supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits manufactured by Bently Nevada in the USA. Each device carries the original serial number and factory seals to ensure authenticity and E-E-A-T compliance for safety-critical applications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224670429368,"sku":"990-05-50-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_b4c2b4eb-d7a3-4566-afab-9adf2fe27645.png?v=1775185321"},{"product_id":"990-04-50-01-cn-bently-nevada-3300-nsv-2-wire-vibration-transmitter","title":"990-04-50-01-CN | Bently Nevada 3300 NSv 2-Wire Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-04-50-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized 2-wire vibration transmitter designed for small-bore machinery and confined installation spaces. It integrates the driver and signal conditioning electronics into a single module, converting radial vibration data into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA current loop output\u003c\/strong\u003e. This model specifically supports the 3300 NSv proximity probe series, providing high-resolution monitoring for shafts where standard 8mm probes cannot fit. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring the \"CN\" regional designation for full compliance with local industrial standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-50-01-CN utilizes a specific coding structure to define its measurement scale and regional certifications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 100 μm peak-to-peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx Hazardous Area Ratings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegional Marking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChinese NEPSI Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers precise machinery protection data through the following parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 100 μm (peak-to-peak).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.0 meters (16.4 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC loop current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 35 mm DIN rail clips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eATEX\/IECEx and Chinese NEPSI marking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2-wire, loop-powered architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-50-01-CN targets specific technical hurdles in modern plant automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-Shaft Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NSv technology enables accurate vibration measurement on shafts as small as 50 mm (2 inches). It reduces \"side-view\" interference, allowing the sensor to operate in tight mechanical housings where standard probes experience signal distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Control Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a direct 4-20 mA signal, this unit bypasses the need for external Proximitor sensors and rack-mounted monitors. You connect the transmitter directly to your PLC or DCS analog input card, reducing total system cost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegional Compliance (NEPSI):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"CN\" variant carries the NEPSI hazardous area marking. This ensures the unit meets all regulatory requirements for installation in explosive atmospheres within the Chinese industrial sector, simplifying safety audits and insurance compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe factory-installed 35 mm DIN rail clips facilitate instant mounting in standard electrical cabinets. The 2-wire loop-powered design further reduces labor by eliminating independent power supply wiring to each transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this transmitter with a standard 3300 XL 8mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This transmitter specifically requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e. The 990-04 series is calibrated for the unique electrical characteristics of the NSv probe tip. Connecting a standard 3300 XL probe will result in significant measurement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 0 to 100 μm range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 100 μm range provides high sensitivity for precision machinery where even small amounts of vibration indicate a critical fault. This metric range (μm) is standard for many European and Asian rotating equipment specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the unit is brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach unit arrives in original Bently Nevada factory packaging with an undisturbed seal. The \"CN\" marking and serial number allow for full traceability through the manufacturer's quality management system, guaranteeing you receive an authentic, unused component.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is a loop-powered device. It draws operating power directly from the 4-20 mA signal loop (typically +24 Vdc). You do not need to run separate power cables, which simplifies field junction box layouts.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224679866552,"sku":"990-04-50-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_b4c2b4eb-d7a3-4566-afab-9adf2fe27645.png?v=1775185321"},{"product_id":"bently-nevada-990-08-xx-01-00-3300-xl-vibration-transmitter","title":"Bently Nevada 990-08-XX-01-00 3300 XL Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-08-XX-01-00 (MOD 165353-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a robust 2-wire vibration transmitter that bridges the gap between proximity sensors and control systems. It integrates the Proximitor sensor and signal conditioning circuitry into a single DIN-rail mounted module. This transmitter converts the raw eddy current signal from a proximity probe into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA current loop\u003c\/strong\u003e, allowing direct monitoring of radial vibration via a PLC or DCS. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compliance with factory specifications for critical asset protection.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990 series utilizes a specific alphanumeric sequence to define calibration and mounting configurations:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 10 mils peak-to-peak (254 µm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecified by order (Standard or Panel Mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard \/ Not Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 meters (29.5 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMOD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e165353-01\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Factory Modification Code\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 990-08 transmitter maintains precise machinery data across long-distance cable runs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Loop Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA (Proportional to 0-10 mils pp vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Proximity Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 to 65 mils (0.25 to 1.65 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal System Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.0 Meters (Calibrated for specific probe\/cable combinations).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35 mm DIN Rail Clips for rapid cabinet installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts +12 to +35 Vdc loop power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 Kg (Including protective industrial packaging).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA (Genuine Bently Nevada Factory Product).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-08-XX-01-00 addresses complex industrial monitoring requirements through targeted design features:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended 9-Meter Reach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 9-meter system length option allows for transmitter installation in remote, safe-area cabinets while the probe remains deep within the machine train. This eliminates the need for intermediate junction boxes in many configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized 4-20 mA Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a standard current loop signal, the 990-08 removes the necessity for expensive, dedicated vibration monitoring racks. It feeds vibration data directly into your plant's existing control infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach unit includes a buffered \"PROX OUT\" terminal. Maintenance teams can connect a portable vibration analyzer to this port to view the raw waveform without breaking the 4-20 mA control loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module incorporates high-grade electromagnetic interference shielding. This prevents signal drift and \"false trips\" caused by the high-frequency noise generated by nearby Variable Frequency Drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMust I use a 9-meter cable with this specific transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 990-08-XX-01-00 is factory-calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9-meter total system length\u003c\/strong\u003e. You must ensure the combined length of your proximity probe and extension cable equals exactly 9 meters. Using a 5-meter or 7-meter setup will result in significant measurement errors and non-linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the MOD 165353-01 code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MOD code indicates a specific factory modification or internal component update authorized by Bently Nevada. This ensures the transmitter meets the latest performance revisions while remaining fully backward compatible with the standard 990-08 series footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the transmitter handle a probe failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features a \"NOT OK\" status indication within the 4-20 mA signal. If the probe or cable becomes open-circuited or shorted, the transmitter drives the output current below 3.6 mA, allowing the DCS to trigger a system fault alarm rather than a false high-vibration trip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this transmitter in a high-vibration area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the transmitter features 35 mm DIN rail clips for secure mounting, you should install it in an enclosure (NEMA 4X or IP65) to protect the electronics from moisture and excessive structural vibration. This preserves the 100% brand-new integrity of the unit over its multi-decade service life.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224680587448,"sku":"990-10-XX-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_d045db27-f18c-411f-83fd-7ba6c7f185f1.png?v=1775185541"},{"product_id":"990-05-50-03-05-bently-nevada-3300-xl-vibration-transmitter","title":"990-05-50-03-05 | Bently Nevada 3300 XL Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-50-03-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision signal conditioner within the 3300 XL Proximity Transducer System. This transmitter facilitates continuous shaft vibration and axial position monitoring by converting raw eddy current signals into a linear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA current loop\u003c\/strong\u003e. It specifically serves balance-of-plant machinery where operators require direct integration into a PLC or DCS without the complexity of a dedicated monitoring rack. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee the integrity of your machinery protection loop.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-50-03-05 follows the standard Bently Nevada configuration logic for 3300 XL systems:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils peak-to-peak (127 µm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Approvals (ATEX\/IECEx\/CSA\/TR CU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers laboratory-grade accuracy to the factory floor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA loop-powered current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±1% typical (under standard conditions); ±2% maximum (under harsh industrial conditions).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports dynamic analysis up to 1 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires 18 to 30 VDC supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCalibrated for 8mm probe tip diameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-grade Stainless Steel for the probe\/connector assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada standard gold-plated coaxial connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-50-03-05 solves critical industrial pain points through superior hardware engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Control System Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output eliminates the need for external Proximitor® units. You can terminate field wiring directly into standard analog input cards, significantly reducing the cost-per-point for vibration monitoring on pumps, fans, and compressors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter's internal circuitry rejects high-frequency electromagnetic interference commonly found near Variable Frequency Drives (VFDs). This ensures the 4-20 mA signal remains stable and free from \"spike\" induced false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeyphasor® Ready:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeyond simple vibration amplitude, this system supports Keyphasor® reference inputs. This allows engineers to obtain phase information for advanced shaft balancing and diagnostic analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit provides a buffered \"Prox Out\" signal. Field technicians can connect a portable analyzer to verify the gap voltage or view the raw orbit without interrupting the 4-20 mA protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMust I match the extension cable length to the transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This model (suffix -05) requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter total system length\u003c\/strong\u003e. You must ensure the sum of the probe lead and the extension cable equals exactly 5.0 meters. Any mismatch will lead to a non-linear output and incorrect vibration readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply do you recommend for this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter operates on an 18-30 VDC range. We recommend a regulated 24 VDC industrial power supply. Ensure the supply can handle the typical 23 mA current draw per transmitter in your loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with non-3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This transmitter is specifically tuned for the electrical impedance of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 8mm probe\u003c\/strong\u003e. Using it with 5mm, 11mm, or non-XL probes will result in incorrect scale factors and potentially blind your protection system to actual vibration levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm this is a brand new unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery 990-05-50-03-05 we ship arrives in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoriginal Bently Nevada factory packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the serial number and \"Made in USA\" labels intact. This guarantees the unit has never been installed or refurbished.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224680751288,"sku":"990-05-50-03-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_ada20c6e-dc79-4d40-b907-88e251c79144.png?v=1775186222"},{"product_id":"990-05-xx-01-00-bently-nevada-3300-xl-vibration-transmitter","title":"990-05-XX-01-00 | Bently Nevada 3300 XL Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-XX-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance, 2-wire vibration transmitter designed for continuous machinery protection. This device integrates the Proximitor sensor and signal conditioning into a single module, converting the raw eddy current signal from a proximity probe into a linear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA output\u003c\/strong\u003e. This allows for direct monitoring via a PLC or DCS without requiring an expensive rack-based monitor. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical rotating equipment operates within safety limits.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990 series configuration defines the specific scale and mounting for your application:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCore Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils peak-to-peak (127 µm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecified (e.g., DIN rail or Panel Mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Approvals (ATEX\/CSA\/IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers laboratory-grade precision in demanding industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA current loop (Proportional to vibration\/position).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 5 mils peak-to-peak (0 to 127 microns).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.0 meters (Calibrated for 5m probe\/cable combinations).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 12,000 cpm (0 to 200 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 XL 8mm Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires +12 to +35 Vdc loop power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-50°C to 120°C (-58°F to 248°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-XX-01-00 solves several industrial monitoring challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCost-Effective Infrastructure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output eliminates the need for dedicated vibration monitoring racks. You feed the signal directly into your existing plant control system (PLC\/DCS), significantly reducing the cost-per-point for balance-of-plant assets like pumps and fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact module mounts easily on 35mm DIN rails. This allows engineers to pack high-density vibration monitoring into small field junction boxes located near the machine train.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Accessibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features a buffered \"Prox Out\" terminal. Maintenance personnel can connect a portable vibration analyzer to view the raw waveform (orbit\/time-base) without interrupting the 4-20 mA protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced internal circuitry rejects electromagnetic interference (EMI). This prevents \"false trips\" often caused by the electrical noise generated by nearby high-power Variable Frequency Drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMust I use a specific cable length with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 990-05-XX-01-\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix specifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter system length\u003c\/strong\u003e. You must use a probe and extension cable that total exactly 5.0 meters. Using a 7-meter or 9-meter cable will result in incorrect calibration and non-linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and a standard Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA standard Proximitor outputs a negative voltage signal (e.g., -200 mV\/mil) that requires a specialized monitor. The 990-05 transmitter converts that signal into a 4-20 mA loop current, making it \"readable\" by any standard industrial analog input card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support hazardous area installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"01\" approval option includes CSA and ATEX certifications. When installed with appropriate intrinsic safety barriers, you can safely monitor machinery located in explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know this item is brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Bently Nevada factory packaging. Each transmitter includes a unique serial number for traceability and is guaranteed to be an authentic USA-manufactured component.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224699396280,"sku":"990-05-XX-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_d7b530be-1b29-4a34-bedc-a39535a0cdc7.png?v=1775186347"},{"product_id":"bently-nevada-990-04-50-01-00-vibration-transmitter-3300-nsv","title":"Bently Nevada 990-04-50-01-00 Vibration Transmitter |  3300 NSv","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-04-50-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized signal conditioner for rotating machinery with limited installation clearance. This 3300 NSv transmitter converts the displacement signal from a non-contacting proximity probe into a linear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA current loop\u003c\/strong\u003e. It specifically targets small-bore machinery where standard probes experience signal distortion from side-view interference. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, manufactured in the U.S.A., ensuring factory-grade accuracy for your plant's vibration monitoring loop.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-50-01-00 utilizes a modular suffix system to define its measurement scale and mounting configuration:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 4 mils peak-to-peak (0 to 100 μm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required (Standard industrial use)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers precise machinery health data directly to your control system:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-Scale Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (Proportional to 0-4 mils \/ 100 μm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires +12 to +35 Vdc input at the transmitter terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Loop Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1,000 Ω (including cable) at 35 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e23 mA typical to prevent downstream over-current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-set for 5.0-meter total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-50-01-00 excels in specific industrial environments where standard sensors fail:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Shaft Specialty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NSv (Narrow Side View) technology allows the sensor to ignore adjacent metal surfaces. This permits accurate vibration measurement on shafts as small as 50 mm (2 inches), solving the \"cross-talk\" issues common in tight mechanical housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Infrastructure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output bypasses the need for expensive, rack-based vibration monitors. You wire the transmitter directly into existing PLC\/DCS analog input cards, significantly lowering the total cost-per-point for balance-of-plant assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Field Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 35 mm DIN rail clips facilitate instant installation in standard electrical cabinets. The loop-powered architecture requires only two wires, reducing cable costs and field labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Portability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA buffered \"Prox Out\" terminal provides access to the raw analog signal. Field technicians connect portable data collectors here to perform spectral analysis or view shaft orbits without disconnecting the protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a standard 3300 XL 8mm probe with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This transmitter only accepts a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e. The 990-04 series uses specific internal circuitry tuned for the NSv probe's electrical characteristics. Using a standard 8mm probe will result in incorrect vibration readings and signal clipping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum distance I can run the 4-20 mA signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith a 35 Vdc power supply, the unit supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1,000 Ω maximum loop resistance\u003c\/strong\u003e. This typically allows for signal cable runs exceeding 1,000 meters depending on wire gauge, making it ideal for remote monitoring in large-scale plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require field calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-04-50-01-00 arrives factory-calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter total system length\u003c\/strong\u003e. Ensure your probe and extension cable combined total exactly 5.0 meters to maintain the ±1% accuracy specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or unused component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. It ships in original Bently Nevada factory packaging with original serial numbers, ensuring the full manufacturer's lifespan and reliability for your critical machinery.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224699822264,"sku":"990-04-50-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_7c4a29c3-c3c7-4ad3-b9a3-0b8557c2e616.png?v=1775186489"},{"product_id":"bently-nevada-990-05-50-01-00-2-wire-vibration-transmitter-3300-xl","title":"Bently Nevada 990-05-50-01-00 2-Wire Vibration Transmitter | 3300 XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-50-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-precision interface between rotating machinery and your plant control system. This 2-wire vibration transmitter converts the complex eddy current signal from a proximity probe into a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA loop current\u003c\/strong\u003e. It provides continuous monitoring of radial vibration or axial position for balance-of-plant assets where a dedicated rack-based monitor is not cost-effective. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, manufactured in the U.S.A., ensuring the highest signal integrity for your industrial automation loop.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990 series follows a modular configuration to match specific machine geometries and system architectures:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCore Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Vibration Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-Scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 mils peak-to-peak (0-125 μm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required (Standard industrial use)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers precise performance in demanding electrical environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC loop current (Proportional to 0-5 mils vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Target Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.5 mm (0.375 in) diameter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-tuned for 5.0-meter total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts loop voltage from +12 to +35 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated clips for standard 35 mm DIN rail mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.43 kg (Net) \/ 0.8 kg (Shipping).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertificate of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A. (COO available upon request).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-05-50-01-00 solves critical industrial integration challenges through robust design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect PLC\/DCS Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output allows you to wire the transmitter directly into standard analog input cards. This eliminates the requirement for expensive, proprietary monitoring racks and simplifies the overall system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2-wire, loop-powered design draws power directly from the signal loop. This reduces the number of cable runs required per sensor point, lowering both material costs and installation labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Accessibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach unit includes a buffered \"Prox Out\" terminal. Maintenance teams can connect portable data collectors or oscilloscopes to this port to view raw vibration waveforms (orbits) without disconnecting or interrupting the protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced internal shielding rejects electromagnetic interference (EMI) generated by nearby motors and variable frequency drives (VFDs), preventing false alarms and ensuring signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMust I use a specific probe with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 990-05 transmitter requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 8mm Proximity Probe\u003c\/strong\u003e. Because the unit is factory-calibrated for the 3300 XL probe’s specific impedance and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter system length\u003c\/strong\u003e, using mismatched probes or different cable lengths will cause significant measurement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe or cable is disconnected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter incorporates a \"NOT OK\" circuit. If the system detects a probe or extension cable failure (open or short circuit), the loop current drives below 3.6 mA. This allows your DCS to distinguish between a \"Zero Vibration\" state and a \"Sensor Fault.\"\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this transmitter in a high-temperature area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the transmitter is rugged, we recommend mounting it in a NEMA 4X or IP65 enclosure if the local ambient temperature exceeds 85°C. This protects the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand-new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einternal electronics and ensures the longevity of the factory calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or original Bently Nevada part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware. Each unit arrives in original factory packaging with an intact serial number, ensuring you receive a genuine product with full performance specifications as manufactured in the U.S.A.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224701788344,"sku":"990-05-50-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_7c4a29c3-c3c7-4ad3-b9a3-0b8557c2e616.png?v=1775186489"},{"product_id":"bently-nevada-991-06-50-01-00-3300-nsv-thrust-transmitter","title":"Bently Nevada 991-06-50-01-00 3300 NSv Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-06-50-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers specialized axial displacement (thrust) monitoring for centrifugal air compressors, small pumps, and industrial fans. This transmitter integrates the functions of a proximity sensor driver and a signal conditioner into a single module. It converts the displacement of a shaft relative to the probe tip into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC signal\u003c\/strong\u003e, facilitating direct integration with PLCs or DCS. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring absolute loop integrity for your critical machinery protection protocols.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991-06-50-01-00 follows a modular configuration logic to match specific mechanical ranges and installation requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThrust Transmitter (Axial Displacement)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 - 0 - 0.6 mm (Metric Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required (Standard industrial version)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter maintains high-fidelity thrust data through the following engineering parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAxial position \/ Thrust displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-scale Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA loop-powered signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-tuned for a 5.0-meter total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts +12 to +35 Vdc input at the terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 35 mm DIN-rail clip integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for the 3300 NSv (Narrow Side View) sensor technology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 991-06-50-01-00 addresses specific industrial challenges in confined or remote monitoring scenarios:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-Bore Geometry Specialty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv technology\u003c\/strong\u003e, allowing for precise measurements on small shafts (less than 50 mm) or in tight bearing housings. It ignores side-view interference from surrounding metal that would otherwise distort the signal on standard probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Monitoring Racks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a direct 4-20 mA current loop, this transmitter removes the requirement for expensive, centralized vibration\/thrust monitoring racks. This significantly lowers the \"cost-per-point\" for balance-of-plant assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe loop-powered 2-wire design reduces cable complexity and labor costs. Technicians wire the unit directly to standard analog input cards within existing control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Transparency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a buffered \"PROX OUT\" terminal. Maintenance personnel connect portable analyzers to this port to verify gap voltage and probe health without interrupting the primary protection loop or disconnecting any wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMust I use a 5-meter probe and cable with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"50\" option code specifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter total system length\u003c\/strong\u003e. To maintain the calibrated 4-20 mA scale factor, the sum of the probe lead length and the extension cable length must equal exactly 5.0 meters. Any mismatch will result in non-linear data and incorrect thrust readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 0.6-0-0.6 mm range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis range is specifically designed for metric-standard machinery. It allows the transmitter to track shaft movement in both directions (towards and away from the active probe) across a 1.2 mm total linear window, providing a \"zero\" reference point for the normal thrust position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this transmitter in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe suffix \"-00\" indicates that this specific unit does not carry hazardous area certifications. If your installation requires ATEX, IECEx, or CSA approvals, you must select the appropriate agency approval option (e.g., -01 or -02) to ensure compliance with explosive atmosphere regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the unit is a genuine Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware in original factory-sealed packaging. Each unit includes the original U.S.A. manufacturing documentation and a unique serial number, ensuring you receive an authentic component with a full service life.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224705982648,"sku":"991-06-50-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_7c4a29c3-c3c7-4ad3-b9a3-0b8557c2e616.png?v=1775186489"},{"product_id":"991-06-50-01-01-bently-nevada-3300-nsv-thrust-transmitter","title":"991-06-50-01-01 | Bently Nevada 3300 NSv Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-06-50-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides specialized axial displacement (thrust) monitoring for centrifugal air compressors, small pumps, and industrial fans. This module integrates the functions of a proximity sensor driver and a signal conditioner into a single, rail-mountable package. It converts the displacement of a shaft relative to the probe tip into a proportional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA DC signal\u003c\/strong\u003e, allowing direct integration with PLCs or DCS for critical machinery protection. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring absolute loop integrity for your plant's predictive maintenance strategy.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series utilizes a modular configuration to match specific mechanical ranges and installation requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Thrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 - 0 - 0.6 mm (Metric Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 meters (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-agency certification (ATEX\/CSA\/IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers high-fidelity axial position data through the following engineering parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAxial position \/ Thrust displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-scale Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA loop-powered signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-tuned for a 5.0-meter total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts +12 to +35 Vdc input at the terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated clips for standard 35 mm DIN-rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for 3300 NSv (Narrow Side View) sensor technology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 991-06-50-01-01 addresses specific industrial challenges in confined or remote monitoring scenarios:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-Bore Geometry Specialty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv technology\u003c\/strong\u003e, enabling precise measurements on shafts smaller than 50 mm (2 inches) or in tight bearing housings. It ignores side-view interference from surrounding metal that typically distorts signals on standard 8mm probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Monitoring Racks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a direct 4-20 mA current loop, this transmitter removes the requirement for expensive, centralized vibration\/thrust monitoring racks. This significantly lowers the \"cost-per-point\" for balance-of-plant assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe loop-powered 2-wire design reduces cable complexity and labor costs. Technicians wire the unit directly to standard analog input cards within existing control cabinets, minimizing the total footprint of the protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Transparency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a buffered \"PROX OUT\" terminal. Maintenance personnel connect portable analyzers to this port to verify gap voltage and probe health without interrupting the primary protection loop or disconnecting any wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMust I use a 5-meter probe and cable with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"50\" option code specifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter total system length\u003c\/strong\u003e. To maintain the calibrated 4-20 mA scale factor, the sum of the probe lead length and the extension cable length must equal exactly 5.0 meters. Any mismatch results in non-linear data and incorrect thrust readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 0.6-0-0.6 mm range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis range follows metric standards and allows the transmitter to track shaft movement in both directions (towards and away from the active probe) across a 1.2 mm total linear window. This provides a \"zero\" reference point for the normal thrust position of the machine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this transmitter in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The suffix \"-01\" indicates the unit carries multi-agency approvals (such as ATEX or CSA). When installed with the appropriate intrinsic safety barriers, this module safely monitors machinery located in explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the unit is a genuine Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware in original factory-sealed packaging. Each unit includes a unique serial number and original U.S.A. manufacturing documentation, guaranteeing an authentic component with a full factory service life.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224707358904,"sku":"991-06-50-01-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_d7ed0f9f-a99a-4e6f-9133-53b6f2166d11.png?v=1775187393"},{"product_id":"bently-nevada-991-25-70-01-01-3300-nsv-thrust-transmitter","title":"Bently Nevada 991-25-70-01-01 3300 NSv Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-25-70-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision axial displacement (thrust) transmitter within the 3300 NSv proximity transducer system. This 2-wire, loop-powered module converts the signal from a non-contacting eddy current probe into a linear\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA output\u003c\/strong\u003e, enabling direct integration with PLCs, DCS, or SCADA systems. It serves as a critical safety component for centrifugal air compressors, small pumps, and industrial fans where monitoring shaft position prevents catastrophic bearing failure. While the manufacturer has officially discontinued this series, we supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esurplus to maintain your existing protection loops without requiring expensive system upgrades.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series follows a specific configuration logic to match mechanical ranges and installation requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Thrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25-0-25 mils (Typical axial displacement window)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN rail clips for high-density mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-agency certifications (ATEX\/CSA\/IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptimized for 5.0 meter or 7.0 meter configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis transmitter delivers high-fidelity thrust data through the following engineering parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC proportional current loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on +12 to +35 Vdc loop power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 1.2 kHz (Suitable for dynamic position tracking).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.95 lbs (0.43 kg).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 35 mm DIN rail clips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTechnology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEddy Current Non-contacting measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 991-25-70-01-01 targets specific industrial pain points in machinery protection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNarrow Side View (NSv) Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter utilizes NSv technology, allowing for precise thrust measurements in tight mechanical geometries. It successfully ignores side-view interference from surrounding metal, a common issue in small bearing housings where standard 8mm probes fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect 4-20 mA Loop Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2-wire design eliminates the need for expensive, centralized vibration\/thrust monitoring racks. You wire the transmitter directly to standard analog input cards, significantly reducing the cost-per-point for balance-of-plant assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic \"Prox Out\" Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach module features a buffered output terminal. Field technicians connect portable analyzers to this port to verify gap voltage and probe health without interrupting the primary 4-20 mA protection loop or disconnecting any wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry rejects electromagnetic interference (EMI) and radio frequency interference (RFI). This ensures stable data even when installed near high-power variable frequency drives (VFDs) or heavy electrical switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle the \"Discontinued\" status of this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the manufacturer no longer produces the 991 series, maintaining spares is critical. Our stock consists of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original factory packaging. Using these genuine parts allows you to replace failed units instantly without re-engineering your entire monitoring architecture to the newer 3300 XL systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this for radial vibration monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 991 series is factory-calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAxial Displacement (Thrust)\u003c\/strong\u003e. For radial vibration (measured in mils peak-to-peak), you must use the 990 series transmitter. Using a thrust transmitter for vibration will result in incorrect signal scaling and compromised machinery safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat total system length does this transmitter require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe suffix \"-01\" for system length is typically calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter or 7.0-meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. You must ensure the combined length of your 3300 NSv probe lead and extension cable matches the factory calibration to maintain measurement linearity and accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 2-wire configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2-wire, loop-powered design simplifies field wiring by using the same two conductors for both power and signal. This reduces cable costs, saves space in junction boxes, and simplifies the overall installation process compared to 3-wire or 4-wire systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53224709095608,"sku":"991-25-70-01-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_caaa1b27-683e-44fa-a555-26cea2ca6183.png?v=1775187515"},{"product_id":"bently-nevada-991-06-50-01-cn-991-series-thrust-transmitter","title":"Bently Nevada 991-06-50-01-CN 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-06-50-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision, loop-powered device designed to monitor axial shaft position (thrust) on rotating machinery. This transmitter integrates the functions of a proximity sensor and a signal conditioner into a single package, providing a proportional 4-20 mA output directly to your PLC or DCS. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein its factory-sealed packaging, backed by a full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-month factory warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series utilizes a specific coding structure to match your machinery’s physical and environmental requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 - 0 - 0.6 mm (approx. 25-0-25 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 metres (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx and Chinese NEPSI hazardous area marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table outlines the critical engineering parameters for the 991-06-50-01-CN:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to thrust position)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 mm - 0 - 0.6 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for use with 3300 XL 8 mm Proximity Probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 35 mm DIN-rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e17.5 to 30 Vdc at the transmitter terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter eliminates the need for separate Proximitor units. It outputs a standard 4-20 mA signal, allowing you to connect vibration data directly to your control system without expensive rack-mounted monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 01 mounting option features 35 mm DIN-rail clips, enabling rapid installation in high-density electrical cabinets where space is a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"CN\" approval ensures the device meets stringent ATEX\/IECEx and NEPSI standards. It operates safely in explosive atmospheres, making it the industry standard for oil, gas, and chemical processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe system design rejects electromagnetic interference (EMI), ensuring stable axial position readings even in electrically noisy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit come with the probe and extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 991-06-50-01-CN refers specifically to the transmitter unit. You must match it with a Bently Nevada 3300 XL 8 mm probe and extension cable to complete the 5.0-meter system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this transmitter in a Zone 0 or Zone 1 environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the CN suffix provides the necessary ATEX\/IECEx and NEPSI markings for hazardous area installations, provided you install it according to the specific agency control drawings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the system length does not match?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use a 5.0-meter total system length (probe + cable). Using a 7.0-meter or 9.0-meter setup with this specific transmitter will cause significant calibration errors and inaccurate thrust readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the product is original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe ship the unit in its original Bently Nevada factory packaging. The serial number on the device matches the factory test reports and the outer box label, ensuring 100% authenticity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272839127224,"sku":"991-06-50-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-00_1e8d81e4-7a09-4dd8-bf3e-0fe4e32a387b.png?v=1775532597"},{"product_id":"991-01-xx-01-00-bently-nevada-991-series-thrust-transmitter","title":"991-01-XX-01-00 | Bently Nevada | 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-01-XX-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical interface for machinery protection, transforming complex proximity probe signals into a simple 4 to 20 mA DC output. This transmitter monitors axial displacement (thrust) on rotating shafts, providing real-time data to PLCs or DCS units without requiring a separate monitor rack. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring maximum equipment uptime and compliance with OEM specifications.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series follows a modular configuration logic to suit specific machinery footprints and cable requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e991 Thrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 - 0 - 0.6 mm (25 - 0 - 25 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable (Matches 5.0m or 9.0m systems)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Agency Approvals (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 991-01-XX-01-00 integrates robust electronics within a compact housing to withstand harsh plant environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA (proportional to axial thrust)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to 3300 XL 8mm Proximity Probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 cm x 6 cm x 10.2 cm (2.8\" x 2.4\" x 4.0\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.46 kg (1.01 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCorrosion-resistant polymer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Control System Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy converting eddy current signals into a 4-20 mA loop, this transmitter eliminates the need for expensive dedicated monitoring racks. It communicates directly with your existing automation hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid DIN-Rail Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated 35 mm DIN-rail clips allow technicians to snap the unit into place within seconds. This design significantly reduces installation labor in high-density control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Climate Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wide operating temperature range (-40°C to +85°C) ensures stable performance in unheated outdoor enclosures or high-heat environments near steam turbines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe narrow width (6 cm) solves the \"limited cabinet space\" pain point, allowing for multiple thrust monitoring channels in a single standard enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require a separate Proximitor?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 991-01-XX-01-00 functions as both the driver and the signal conditioner. It replaces the Proximitor and outputs a 4-20 mA signal directly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the transmitter matches my probe?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"XX\" in your part number must match your total system length (typically 5.0 meters or 9.0 meters). Using a 5.0m transmitter with a 9.0m cable will result in incorrect displacement readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application for this specific model?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit excels in monitoring centrifugal air compressors, small pumps, motors, and industrial fans where axial shaft movement must be tracked to prevent catastrophic bearing failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product used or refurbished?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely not. We deliver only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New, original factory-packed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada units. Each device includes the original manufacturer’s quality assurance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272844665016,"sku":"991-01-xx-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_b225407c-1d3e-4f7d-ae2f-a80776129576.png?v=1775532837"},{"product_id":"991-06-70-01-00-bently-nevada-991-series-thrust-transmitter","title":"991-06-70-01-00 | Bently Nevada 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-06-70-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates proximity probe signal conditioning and 4-20 mA output into a single, compact device. Designed to monitor axial shaft position (thrust) on critical rotating machinery, this transmitter provides essential protection data directly to your PLC or DCS. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory-sealed packaging, ensuring full compatibility with your existing machinery protection strategy.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series utilizes a modular selection process to ensure the electronics match the physical probe installation:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 - 0 - 0.6 mm (25 - 0 - 25 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 metres (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Agency Approvals (Standard Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 991-06-70-01-00 maintains high-fidelity signal conversion for long-term industrial use:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to axial thrust)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 mm - 0 - 0.6 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for 3300 XL 8 mm Proximity Probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical System Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.0 meters (Probe + Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+17.5 to +30 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.46 kg (1.01 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Control System Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter eliminates the requirement for a centralized monitoring rack. By outputting a linearized 4-20 mA signal, it allows your DCS to handle alarm and shutdown logic directly, reducing infrastructure costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Mid-Length Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"70\" system length option specifically supports 7.0-meter electrical configurations. This provides the necessary flexibility for installations where 5.0 meters is too short, but 9.0 meters creates excessive cable slack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach unit features a BNC connector that provides a raw buffered signal. Reliability engineers can connect a portable analyzer to verify probe gap or vibration signatures without interrupting the 4-20 mA loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Cabinet Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 01 mounting option includes pre-installed 35 mm DIN-rail clips. This \"snap-on\" design minimizes installation time and allows for high-density mounting in congested electrical panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with a 5.0-meter or 9.0-meter probe system?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The \"70\" option indicates this transmitter is calibrated specifically for a 7.0-meter total electrical length. Using mismatched lengths will cause significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 12-month warranty included?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Since we provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eequipment, the product carries a full 12-month factory warranty from the date of purchase.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"00\" suffix for agency approvals?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"00\" suffix indicates a standard version without specialized hazardous area certifications like ATEX or IECEx. This version is intended for use in safe\/general-purpose industrial areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit ship with the 3300 XL probe?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 991-06-70-01-00 is the transmitter only. Proximity probes and extension cables must be ordered separately to match your specific machine mounting requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272845877432,"sku":"991-06-70-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_f1ef2ca9-7420-4203-b5f3-0b592f6ddde2.png?v=1775533628"},{"product_id":"bently-nevada991-series-thrust-transmitter-991-25-70-01-cn","title":"Bently Nevada991 Series Thrust Transmitter | 991-25-70-01-CN","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-25-70-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides critical axial position monitoring for high-speed rotating machinery. This transmitter integrates a proximity probe driver and a signal conditioner into a single, high-performance unit. It converts complex eddy current signals into a linear 4 to 20 mA DC output for direct communication with your PLC or DCS. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging, ensuring compliance with global safety and engineering standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series modular code defines the measurement range, electrical length, and safety certifications required for your specific application:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 - 0 - 1.2 mm (approx. 50-0-50 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 metres (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx and Chinese NEPSI hazardous area marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 991-25-70-01-CN maintains precision in demanding industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to axial thrust)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.2 mm - 0 - 1.2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for 3300 XL 8 mm Proximity Probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical System Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.0 meters (Probe + Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+17.5 to +30 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully certified for Hazardous Areas (ATEX, IECEx, NEPSI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Measurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"25\" option offers a wide 1.2-0-1.2 mm scale. This solves the challenge of monitoring machines with significant thermal expansion or axial float that exceeds standard sensor ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Hazardous Area Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"CN\" suffix confirms the unit meets ATEX, IECEx, and NEPSI standards. This allows for safe deployment in explosive atmospheres across international markets, specifically within the Chinese industrial sector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRackless Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a linearized 4-20 mA signal, this transmitter removes the need for a 3500 monitoring rack. This significantly lowers the total cost of ownership for smaller pump, motor, and fan sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density DIN-Rail Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 01 mounting option features integrated 35 mm DIN-rail clips. This design enables fast, secure installation in space-constrained control cabinets and junction boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a 5.0m or 9.0m cable with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This unit is calibrated for a 7.0-meter total electrical system length. Using a different length will result in inaccurate position data and potential false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include a buffered output for diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Every 991 transmitter includes a BNC connector that provides a raw buffered signal. You can connect a portable analyzer to verify probe health and vibration signatures without disconnecting the 4-20 mA loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product used or surplus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We only sell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada equipment. Each unit ships in its original factory box and includes a standard 12-month factory warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"25\" range compare to the \"06\" range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"25\" range (1.2-0-1.2 mm) is twice as wide as the standard \"06\" range (0.6-0-0.6 mm), making it ideal for larger machinery where greater axial movement is expected during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272849973432,"sku":"991-25-70-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_ecddb11f-d082-47f4-813b-6fc47ed5e6a9.png?v=1775533792"},{"product_id":"bently-nevada-990-10-xx-01-05-vibration-transmitter-990-series","title":"Bently Nevada 990-10-XX-01-05 Vibration Transmitter | 990 Series","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-10-XX-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides continuous radial vibration monitoring for industrial rotating machinery. This transmitter drives a 3300 XL 8mm proximity probe and converts the complex displacement signal into a linearized 4 to 20 mA DC output. This \"rackless\" solution allows you to integrate high-fidelity vibration data directly into your PLC or DCS. We deliver this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory-sealed packaging, backed by a full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-month factory warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990 series configuration determines the measurement scale, system length, and regional safety compliance:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Radial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-254 µm (0-10 mils) peak-to-peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMatches 5.0m or 9.0m cable systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA\/NRTL\/C (Class I, Div 2, Groups A-D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 990-10-XX-01-05 ensures precision monitoring in high-interference environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to peak-to-peak vibration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 254 µm (0 to 10 mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically for 3300 XL 8 mm Proximity Probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+17.5 to +30 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified for North American Division 2 locations (Option 05)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.46 kg (1.01 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCost-Effective Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter eliminates the need for expensive, centralized monitor racks. It provides a direct 4-20 mA loop to your control system, making it the ideal choice for auxiliary equipment like fans, pumps, and small motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery unit features a BNC connector providing a raw buffered signal. Technicians can connect a portable data collector to view the actual vibration waveform without interrupting the 4-20 mA protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 01 mounting option includes pre-installed 35 mm DIN-rail clips. Its compact 6 cm width allows you to mount dozens of channels in a single local junction box, saving significant cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDivision 2 Certified:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"05\" approval allows for safe installation in Class I, Division 2 hazardous environments. This ensures compliance with North American safety standards for oil, gas, and chemical processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 990 and 991 models?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 990 series monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRadial Vibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(shaft movement side-to-side), while the 991 series monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThrust Position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(shaft movement axial\/end-to-end). Ensure you select the correct model for your specific protection logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix system lengths (e.g., use a 5.0m transmitter with a 9.0m cable)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"XX\" in your part number must match your total electrical system length (probe plus extension cable). Mismatched lengths will lead to significant calibration errors and unreliable 4-20 mA data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 990-10-XX-01-05 combines the probe driver and the 4-20 mA transmitter into one housing. It replaces the traditional Proximitor entirely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the product original Bently Nevada?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New, original factory-packed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware. The unit includes the original serial number and is eligible for full manufacturer support and our 12-month warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272851480760,"sku":"990-10-XX-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_b2c42aea-80d1-4ad1-bcab-f0acbfc92241.png?v=1775533963"},{"product_id":"990-10-xx-02-00-bently-nevada-990-series-vibration-transmitter","title":"990-10-XX-02-00 | Bently Nevada 990 Series Vibration Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-10-XX-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-performance signal conditioner designed for radial vibration monitoring on rotating machinery. This transmitter specifically interfaces with 3300 NSv (Near Side view) proximity probes, making it the primary choice for applications with small shaft diameters or tight mounting clearances. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein its factory-sealed packaging, ensuring long-term stability and compliance with original equipment manufacturer (OEM) standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 990-10-XX-02-00 configuration utilizes a modular selection code to define measurement range and physical installation hardware:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Transmitter (Radial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-254 µm (0-10 mils) peak-to-peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMatches 5.0m or 7.0m system lengths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulkhead mounting (Standard Plate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Agency Approvals (General Purpose)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 990-10-XX-02-00 delivers precise 4-20 mA data via a simplified 2-wire loop-powered architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects directly to 3300 NSv proximity probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA analog (proportional to vibration levels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 Hz to 6,000 Hz (300 to 360,000 cpm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e17.5 to 30 Vdc (2-wire loop powered)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Lengths:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAvailable in 5.0m and 7.0m electrical configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBrand New, original factory packing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Restricted Spaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard proximity systems, this transmitter works with the 3300 NSv series. The NSv technology allows for accurate vibration measurement on shafts as small as 50 mm (2 inches) where standard sensors encounter side-view interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Control System Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit eliminates the need for expensive rack-mounted monitors. It outputs a standard 4-20 mA signal that communicates directly with your PLC or DCS, reducing hardware footprint and total installation cost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Bulkhead Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"02\" mounting option provides a sturdy bulkhead plate. This allows engineers to mount the transmitter inside local junction boxes or directly onto machine frames where DIN-rail space is unavailable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5 Hz to 6,000 Hz response range ensures the transmitter captures both low-speed shaft unbalance and high-frequency harmonic content, providing a comprehensive view of machine health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with a standard 3300 XL 8mm probe?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 990-10-XX-02-00 is specifically calibrated for the 3300 NSv probe series. Using it with a standard 8mm probe will cause significant measurement errors and non-linear outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose between the 5m and 7m \"XX\" option?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"XX\" must match the total electrical length of your probe and extension cable combined. A mismatch between the transmitter calibration and the physical cable length will compromise data accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter provide a raw signal for diagnostics?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The unit includes a BNC connector that provides a buffered raw vibration signal. Reliability technicians can connect portable analyzers to this port for detailed waveform analysis without interrupting the 4-20 mA protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or used component?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely not. We deliver only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware. Each unit includes the factory serial number and the standard 12-month manufacturer warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272855380152,"sku":"990-10-XX-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_3c33bd74-3096-4a69-983c-92a5f04dd47c.png?v=1775534108"},{"product_id":"bently-nevada-991-25-50-01-00-991-series-thrust-transmitter","title":"Bently Nevada 991-25-50-01-00 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-25-50-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-accuracy axial displacement monitoring for critical industrial machinery. This transmitter drives a 3300 XL 8mm proximity probe and translates the complex eddy current signal into a linear 4 to 20 mA output. This allows for seamless integration of thrust data into your PLC or DCS without the need for a dedicated monitor rack. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, manufactured in the U.S.A. and delivered in factory-sealed packaging.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991-25-50-01-00 utilizes a specific configuration to match your machine's mechanical stroke and cable routing requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 - 0 - 25 mils (approx. 1.2-0-1.2 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 metres (16.4 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Agency Approvals Required (General Purpose)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following parameters define the operational limits and output characteristics of the 991-25-50-01-00:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (proportional to axial thrust position)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25-0-25 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical System Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.0 meters (Probe + Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 35 mm DIN-rail clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+17.5 to +30 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in U.S.A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kg (including factory packaging)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Axial Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"25\" full-scale option provides a wider 25-0-25 mil range. This extra headroom accommodates machines with significant thermal growth or larger axial clearances that standard transmitters might clip or fail to track.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Rack-less Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter eliminates the infrastructure costs of a centralized monitoring rack. It sends thrust data directly to your control system, making it an ideal choice for balance-of-plant equipment like small turbines, pumps, and fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Cabinet Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 01 mounting option features pre-installed 35 mm DIN-rail clips. Technicians can snap the unit onto a standard rail in seconds, significantly reducing wiring time and labor in high-density control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered with advanced interference rejection, the unit maintains signal integrity in electrically noisy environments. This ensures your PLC receives a stable, reliable 4-20 mA loop even when located near high-voltage motor starters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with a 9.0-meter probe system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This transmitter is specifically calibrated for a 5.0-meter electrical system length. Using a 9.0-meter probe or cable will result in incorrect position data and potential false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit replace a 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 991-25-50-01-00 performs the same driving function as a Proximitor but adds the signal conditioning necessary to output a 4-20 mA current loop instead of a raw voltage signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I perform field diagnostics on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach transmitter includes a BNC connector providing a raw buffered signal. You can connect a portable vibration analyzer to this port to verify the probe gap and view shaft behavior without interrupting the primary 4-20 mA protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product used or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely not. We deliver only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada equipment in original factory boxes. Every unit includes the manufacturer's standard 12-month warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272858165432,"sku":"991-25-50-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_f9881a6a-3ab5-462f-a524-c88dd0e84937.png?v=1775534390"},{"product_id":"991-06-70-01-cn-bently-nevada-991-series-thrust-transmitter","title":"991-06-70-01-CN | Bently Nevada 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-06-70-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides critical axial position monitoring for high-speed rotating machinery. This transmitter drives a 3300 XL 8mm Proximity Probe and converts the eddy current signal into a linearized 4 to 20 mA DC output. This \"rackless\" solution enables direct communication with your PLC or DCS, eliminating the need for separate monitor racks. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein its factory-sealed packaging, backed by a full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-month factory warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series uses a modular coding structure to ensure the electronics match your specific machine and cable configuration:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 - 0 - 0.6 mm (approx. 25-0-25 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 metres (23.0 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail clips\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx and Chinese NEPSI hazardous area marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 991-06-70-01-CN delivers stable, high-fidelity data in demanding industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC (Proportional to axial thrust)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 mm - 0 - 0.6 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for 3300 XL 8 mm Proximity Probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical System Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.0 meters (23.0 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35 mm DIN-rail (Option 01)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e+17.5 to +30 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"CN\" approval provides necessary ATEX, IECEx, and NEPSI certifications. This allows for safe installation in explosive atmospheres, particularly within the Chinese industrial market.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Control Loop Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter eliminates the infrastructure costs of a centralized monitoring rack. It sends thrust data directly to your control system, making it an ideal choice for balance-of-plant equipment like pumps and motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Mid-Length Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 7.0-meter system length option solves the problem of cable routing in larger machine enclosures where standard 5.0-meter cables fail to reach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach unit features a BNC connector providing a raw buffered signal. Reliability technicians can connect a portable analyzer to verify probe health and shaft behavior without interrupting the 4-20 mA protection loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a 5.0m or 9.0m cable with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This unit is calibrated specifically for a 7.0-meter total electrical system length. Using a different cable length will cause significant measurement errors and potentially lead to false trips or failed machine protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product used or refurbished?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eNo. We deliver only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware. Each unit includes the factory serial number and ships in the original manufacturer’s packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include the proximity probe?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eThe 991-06-70-01-CN is the transmitter only. Proximity probes and extension cables must be ordered separately to match your specific installation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the DIN-rail mounting?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eThe integrated 35 mm DIN-rail clips allow for rapid, \"snap-on\" installation in high-density electrical cabinets, reducing labor time and optimizing cabinet space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272863932600,"sku":"991-06-70-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_3b4427b0-ced6-4749-a769-2ca1d46f6873.png?v=1775540836"},{"product_id":"991-25-xx-01-cn-bently-nevada-991-series-thrust-transmitter","title":"991-25-XX-01-CN | Bently Nevada 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-25-XX-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision 991 Thrust Transmitter, serving as a cornerstone for modern machinery protection strategies. This device converts the complex signal from a 3300 NSv proximity probe into a linearized 4-20 mA current signal. By translating axial displacement into a standard industrial format, it enables plant operators to integrate critical vibration and position data directly into Distributed Control Systems (DCS) or PLCs without additional interface modules.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eBently Nevada utilizes a modular numbering system to define specific hardware configurations. For the 991 series, the coding typically follows this logic:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e991 Thrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefines the displacement range (e.g., 25-0-25 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecifies DIN rail or bulkhead mounting hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndicates specific hazardous area certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegional Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigured for specific regional standards\/documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table outlines the critical physical and electrical parameters for the 991-25-XX-01-CN:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Source\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Proximity Probe Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA DC (Proportional to Axial Displacement)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +85°C (-31°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.3 cm x 6 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New, Factory Sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 991-25-XX-01-CN solves several high-stakes mechanical engineering challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Signal Conversion Lag:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy outputting a direct 4-20 mA signal, the transmitter bypasses the need for external monitors. This simplifies the control loop and reduces potential points of failure in the signal chain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact footprint allows engineers to mount the unit within local junction boxes or crowded control cabinets, making it ideal for retrofitting older machinery where space remains at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an operational ceiling of +85°C and robust housing, this unit maintains signal integrity near hot turbine housings or in unconditioned industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter works seamlessly with the 3300 NSv probe, ensuring linear accuracy across the entire displacement range with minimal field adjustment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 991-25-XX-01-CN with standard 3300 XL 8mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This transmitter specifically requires the signal from a 3300 NSv (Near Surface) proximity probe. Using an incompatible probe will result in non-linear readings and potential machinery damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit handle power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter operates on a loop-powered principle. If the 4-20 mA loop breaks or loses power, the control system immediately detects a \"Low\" signal (0 mA), triggering an instrument fault alarm to prevent unmonitored operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit shipped in original Bently Nevada packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the 991-25-XX-01-CN in 100% brand-new condition, contained in its original factory-sealed box with all relevant manufacturer documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical lead time for international shipping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe maintain this item in stock. Most orders ship via DHL within 3 business days, ensuring minimal downtime for your critical machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272971411640,"sku":"991-25-XX-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_69200ae5-6c4d-4879-8c6f-ee82da3b0b91.png?v=1775540991"},{"product_id":"bently-nevada-991-01-xx-01-05-991-series-thrust-transmitter","title":"Bently Nevada 991-01-XX-01-05 991 Series Thrust Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 991-01-XX-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents a high-performance solution for monitoring axial displacement in critical rotating machinery. This transmitter interfaces directly with proximity probe systems, converting raw transducer signals into a linearized 4-20 mA output. By integrating this module, engineers transmit vital thrust position data directly to PLC or DCS platforms, eliminating the need for bulky rack-mounted monitoring systems. This unit originates from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand arrives in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand-new factory condition\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 991 series utilizes a specific alphanumeric code to designate hardware scale and certification. The breakdown for the 991-01-XX-01-05 includes:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e991 Thrust Transmitter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-scale Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25-0-25 mils (standard range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCustomer-specified mounting hardware (e.g., DIN rail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal safety and hazardous area certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 metre (16.4 feet) system length compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis compact transmitter delivers precise measurement within a lightweight architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA DC (proportional to axial displacement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Transducer Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 kg (Ultra-lightweight for rail-mounted clusters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMade in USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Original and Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 991-01-XX-01-05 addresses specific industrial challenges through superior design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Slim Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2.2 cm width allows high-density installation. Engineers fit multiple transmitters into small local junction boxes, maximizing cabinet real estate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Control System Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-20 mA output removes the requirement for specialized vibration monitors. This simplifies the loop architecture and reduces overall system costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced internal circuitry filters out electromagnetic interference (EMI), ensuring stable displacement readings even in electrically noisy turbine halls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Field Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe lightweight 0.1 kg frame minimizes mechanical stress on DIN rails, while the clear terminal markings facilitate error-free wiring during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include the proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 991-01-XX-01-05 acts as the transmitter\/signal conditioner. You must pair it with a compatible extension cable and proximity probe (typically 3300 series) to complete the measurement chain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product an authentic Bently Nevada component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply only 100% brand-new, original Bently Nevada equipment in factory-sealed packaging, ensuring full compliance with your machinery protection standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the 990 and 991 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 990 series typically monitors vibration (velocity\/acceleration), the 991 series focuses specifically on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThrust (axial displacement)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent catastrophic internal contact between rotors and stators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this transmitter in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"-01\" agency approval code indicates specific certification levels. Always verify your site's Class\/Division or Zone requirements against the specific label on the 991 transmitter before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53272971641016,"sku":"991-01-XX-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/990-04-XX-01-001_b866bc75-a480-49a3-8f21-748c8947f8ae.png?v=1775542719"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/bently-nevada-990-991-series.oembed","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}