{"title":"Communication \u0026 Networking","description":"\u003cp\u003eIn modern smart manufacturing, data silos are the enemy of efficiency. Our industrial communication and networking range focuses on robust, low-latency hardware designed for harsh electromagnetic environments. We provide the essential bridges between OT and IT, supporting protocols like PROFINET, EtherNet\/IP, and Modbus TCP. Whether you are upgrading legacy serial machinery or building a high-speed fiber backbone, these modules ensure deterministic data flow and maximum uptime for critical infrastructure.\u003c\/p\u003e","products":[{"product_id":"kj3243x1-ba1-emerson-deltav-profibus-dp-interface-module","title":"KJ3243X1-BA1 | Emerson DeltaV | Profibus DP Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eEmerson DeltaV KJ3243X1-BA1 Profibus DP Series 2 Interface Card\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3243X1-BA1 (P\/N: 12P2830X022)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized communication interface module for the Emerson DeltaV Distributed Control System (DCS). Functioning as a Profibus DP Master, this Series 2 card enables the DeltaV controller to integrate seamlessly with various fieldbus devices, including motor control centers (MCCs), variable frequency drives (VFDs), and remote I\/O skids. By centralizing the management of high-speed serial communications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3243X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for extensive data exchange and advanced device diagnostics over a single Profibus network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following data accurately reflects the hardware specifications of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3243X1-BA1 (P\/N: 12P2830X022)\u003c\/strong\u003e. Note that this is a Profibus DP communication interface, not an Analog Output module.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmerson (DeltaV Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3243X1-BA1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12P2830X022\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProfibus DP (Decentralized Periphery)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 12 Mbps (Automatic Baud Rate detection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocal Bus Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e600 mA maximum at 12 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation to protect system logic from fieldbus transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 125 slave devices per segment (with repeaters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 °C to +70 °C (Extended Industrial Range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA-S71.04-1985 Class G3 (Conformal Coated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 130 x 40 x 120 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.20 kg (0.44 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Network Integration and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ3243X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplifies the complexity of industrial networking by utilizing the DeltaV Explorer and Control Studio for configuration. This Series 2 card provides enhanced processing power to handle large cyclical data transfers (I\/O) and acyclical messages (parameters and diagnostics) simultaneously. Because it is conformal coated to G3 standards, the module is highly resistant to corrosive gases and humidity, making it ideal for wastewater treatment, oil refining, and chemical processing facilities.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52495070429368,"sku":"KJ3243X1-BA1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/178..jpg?v=1769157112"},{"product_id":"yokogawa-cp401-10-cp401-10-centum-vp-communication-processor","title":"Yokogawa CP401-10 | CP401-10 CENTUM VP Communication Processor","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa CP401-10 CENTUM VP\/CS 3000 Communication Processor Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10 (Model: CP401-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication interface and processor module designed for Yokogawa’s CENTUM VP and CS 3000 Distributed Control Systems (DCS). This module serves as a critical bridge between the DCS core and external subsystems, acting as a gateway for diverse industrial protocols. Beyond its communication role, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports complex pulse input processing, including voltage and current pulses from field transmitters. Engineered for 24\/7 continuous operation, it provides the deterministic data throughput required for mission-critical monitoring and control in refineries, power plants, and chemical processing facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following specifications define the hardware capabilities and signal handling parameters for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10 (Model: CP401-10)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCENTUM VP, CENTUM CS 3000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Processor \/ Pulse Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (±10%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContact ON\/OFF, Voltage Pulse, Current Pulse (with transmitter power supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Frequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Pulse Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 VAC withstand voltage (Channel-to-System) for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Memory card slots for configuration backup and historical data logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet\/IP, Modbus\/TCP, Profibus, and proprietary Vnet\/IP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Yokogawa FCS Nest compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.8kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSwitzerland \/ Japan (Global production sites)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMulti-Protocol Gateway and Pulse Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides dual-functionality that simplifies system architecture by combining high-speed pulse acquisition with advanced communication gateway capabilities. It is specifically optimized for applications involving flow measurement and rotating equipment where high-frequency pulse signals (up to 10 kHz) must be converted into engineering units for the DCS. Its robust isolation (500 VAC) ensures that field-side electrical transients do not reach the sensitive system backplane, maintaining overall plant safety and hardware longevity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Reliability and Data Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTo ensure high availability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10 (Model: CP401-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes dual memory card slots, allowing for redundant storage of configuration parameters and critical communication logs. This feature enables rapid module replacement and commissioning, as the system can automatically reload the configuration from the memory card upon power-up. The module is built with industrial-grade components designed to withstand the electromagnetic interference (EMI) typical of heavy manufacturing environments, ensuring stable data exchange between the enterprise network and field instrumentation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52495180169400,"sku":"CP401-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/397._6434f8ac-c9a5-441d-8541-89d6c8c61587.jpg?v=1769159685"},{"product_id":"fc-dcom-234-485-communication-interface-module-honeywell","title":"FC-DCOM-234\/485 Communication Interface Module Honeywell","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-DCOM-234\/485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed serial communication interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. It provides a reliable bridge between internal processor signals and industry-standard serial protocols, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS232\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS485\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS422\u003c\/strong\u003e, enabling seamless integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman-Machine Interfaces (HMI)\u003c\/strong\u003e, and third-party PLCs.\u003c\/p\u003e\n\u003cp\u003eEquipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual communication ports\u003c\/strong\u003e, the module supports transparent data transmission as well as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized coding schemes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eManchester\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM0\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM1\u003c\/strong\u003e. Designed for industrial longevity, it features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal-coated PCB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto resist moisture, dust, and corrosive environments. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esnap-on DIN-rail mounting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows quick installation in standard control cabinets, providing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL-rated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epathway for safety-critical communication.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-DCOM-234\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSerial Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +60°C (14°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e110 mm × 70 mm × 61 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Performance Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epoint-to-point (RS232)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-drop (RS485\/422)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etopologies for diverse integration scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS485\/422 port supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 MBaud\u003c\/strong\u003e, enabling rapid, time-sensitive safety data transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating ensures reliable operation in harsh\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments with dust, moisture, or chemical exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL-Ready:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTUV-approved for safety-critical communication loops, maintaining the SIL rating of the Safety Manager system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003cbr\u003eNo. The FC-DCOM-234\/485 draws\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 VDC directly from the Honeywell Control Processor\u003c\/strong\u003e, simplifying cabinet power wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used for Modbus communication?\u003c\/strong\u003e\u003cbr\u003eYes. While it functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical-layer converter\u003c\/strong\u003e, it is commonly deployed to facilitate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor other serial protocols between the Safety Manager and external hardware.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52495189213368,"sku":"FC-DCOM-234\/485","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-DCOM-234485.jpg?v=1769153720"},{"product_id":"ge-mark-vie-is420eswbh1a-industrial-ethernet-switch","title":"GE Mark VIe IS420ESWBH1A Industrial Ethernet Switch","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGE IS420ESWBH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an industrial-grade managed Ethernet switch module designed for GE Mark VIe control systems, used in gas and steam turbine networks. It provides reliable Ethernet connectivity for controllers, I\/O modules, HMIs, and other network devices, supporting deterministic and secure communication in critical industrial environments, including power generation, oil \u0026amp; gas, and heavy industry.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIS420ESWBH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eManaged Ethernet Switch Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VIe\/VIeS Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e16 × 10\/100Base-TX RJ-45 copper ports + 1 fiber port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e1.6 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForwarding Rate\u003c\/td\u003e\n\u003ctd\u003e1.2 Mpps (Million Packets per Second)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC Address Table\u003c\/td\u003e\n\u003ctd\u003e8K entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN Support\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q VLAN tagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupports ring redundancy and Rapid Spanning Tree Protocol (RSTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24\/28 VDC (range 18–30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC isolation between ports and power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e225 × 167 × 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDirect installation into Mark VIe racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eConvection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED for port link\/activity and power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52500638990520,"sku":"IS420ESWBH1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/12..jpg?v=1769393106"},{"product_id":"1769-l33er-a-allen-bradley-compactlogix-ethernet-processor","title":"1769-L33ER\/A  Allen Bradley CompactLogix Ethernet Processor","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-L33ER (Series A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance controller within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley CompactLogix 5370\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily, designed for mid-range automation applications. It delivers a powerful platform for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated motion control, high-speed I\/O\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust network connectivity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough dual EtherNet\/IP ports. An internal energy storage module eliminates the need for a battery, preserving user data during power cycles while reducing long-term maintenance requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB on-board volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Storage\u003c\/td\u003e\n\u003ctd\u003e1 GB Secure Digital (SD) card included (supports up to 2 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Local I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 16 × 1769 Compact I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 × EtherNet\/IP ports, 1 × USB 1.1 configuration port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Topologies\u003c\/td\u003e\n\u003ctd\u003eLinear and Device Level Ring (DLR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 axes over EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Ethernet Nodes\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e32 tasks, up to 100 programs per task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 5 V DC\u003c\/td\u003e\n\u003ctd\u003e560 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 24 V DC\u003c\/td\u003e\n\u003ctd\u003e225 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C (32 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe 1769-L33ER is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed packaging machines\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efood and beverage production lines\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ematerial handling systems\u003c\/strong\u003e, where accurate motion control and distributed I\/O performance are essential.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate power supply?\u003c\/strong\u003e\u003cbr\u003eYes. The controller must be powered using one of the following modules:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-PA2, 1769-PB2, 1769-PA4, or 1769-PB4\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs Series A hardware compatible with current firmware?\u003c\/strong\u003e\u003cbr\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStudio 5000 Logix Designer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is compatible with current firmware revisions within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5370 L3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller family.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many expansion banks are supported?\u003c\/strong\u003e\u003cbr\u003eUp to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 I\/O banks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia expansion cables, provided the total number of I\/O modules does not exceed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501290352824,"sku":"1769-L33ER\/A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L33ERA1.jpg?v=1769414519"},{"product_id":"allen-bradley-compactlogix-ethernet-controller-1769-l30","title":"Allen Bradley CompactLogix Ethernet Controller 1769-L30","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-L30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5370 L3 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for moderate memory applications and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed logic\/process control\u003c\/strong\u003e. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual Ethernet ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Device Level Ring (DLR) or linear network topologies and supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 local 1769 I\/O modules\u003c\/strong\u003e, enabling compact solutions without additional chassis. This model is optimized for discrete and process control, with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOpen Socket TCP\/UDP communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor integration with non-Rockwell devices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1769-L30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e1 MB volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Storage\u003c\/td\u003e\n\u003ctd\u003eSD Card support for firmware\/project backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Local I\/O\u003c\/td\u003e\n\u003ctd\u003e8 × 1769 Compact I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Nodes\u003c\/td\u003e\n\u003ctd\u003eUp to 16 EtherNet\/IP nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 × Copper 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Port\u003c\/td\u003e\n\u003ctd\u003e1 × USB Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, DeviceNet (via 1769-SDN scanner), Open Socket (TCP\/UDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C (32–140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTasks Supported\u003c\/td\u003e\n\u003ctd\u003eUp to 32 tasks, 100 programs per task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Notes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Socket\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows communication with non-Rockwell devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual Ethernet ports act as an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated switch\u003c\/strong\u003e, reducing wiring costs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith an optional 1769-SDN scanner\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediscrete\/process control\u003c\/strong\u003e, not for integrated motion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501302051000,"sku":"1769-L30","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L301.jpg?v=1769411986"},{"product_id":"communication-module-allen-bradley-1769-sm1","title":"Communication Module Allen Bradley 1769-SM1","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-SM1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley CompactLogix and MicroLogix 1500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. It connects\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elegacy SCANport\/DPI drives\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., PowerFlex 7-Class, 1305, 1336, 1397) directly to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769 Compact I\/O backplane\u003c\/strong\u003e, allowing the controller to perform\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time monitoring, command execution, and status feedback\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas if the drive were a local I\/O module. This simplifies migration of older drives into modern Logix-based control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1769-SM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Adapter \/ Drive Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Drives\u003c\/td\u003e\n\u003ctd\u003eSCANport-capable (PowerFlex 7-Class, 1305, 1336, 1397, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e280 mA @ 5.1V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Ports\u003c\/td\u003e\n\u003ctd\u003e1 SCANport \/ DPI interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e125–500 Kbps (drive-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eLogic commands, status, reference, feedback, datalinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Datalinks\u003c\/td\u003e\n\u003ctd\u003e8 (4 in \/ 4 out)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500V DC between SCANport and backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Width\u003c\/td\u003e\n\u003ctd\u003e1 Slot (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e118 x 35 x 87 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Notes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects older SCANport\/DPI drives as local I\/O, no complex gateway needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRSLogix 5000\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStudio 5000\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConnected Components Workbench (CCW)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDraws logic power from the 1769 backplane; the drive provides SCANport-side power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports one drive per module; multiple drives require multiple SM1 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this be used with PowerFlex 525 or 520 drives?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. Use direct EtherNet\/IP for newer drives; SM1 is for legacy SCANport\/DPI devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes this module need an external power supply?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, logic power comes from the 1769 backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many drives can one SM1 control?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne SCANport device per module.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501321449656,"sku":"1769-SM1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-SM11.jpg?v=1769411064"},{"product_id":"allen-bradley-1769-l33er-compactlogix-ethernet-processor","title":"Allen Bradley 1769-L33ER CompactLogix Ethernet Processor","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-L33ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emid-range CompactLogix 5370 L3 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombining high-speed logic, Integrated Motion, and dual-port Ethernet\/IP connectivity. It is designed for modern industrial applications requiring scalable control, precise motion coordination, and enterprise-level network integration. Maintenance-free operation is provided via an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal energy storage module\u003c\/strong\u003e, eliminating the need for a battery while preserving program data during power interruptions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1769-L33ER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 16 1769 Compact I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 × 10\/100 Mbps Ethernet\/IP (DLR-capable, integrated switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Port\u003c\/td\u003e\n\u003ctd\u003e1 × USB 1.1 (high-speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Nodes\u003c\/td\u003e\n\u003ctd\u003eUp to 32 EtherNet\/IP nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion\u003c\/td\u003e\n\u003ctd\u003eUp to 8 axes on EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e32 tasks, 100 programs per task\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4 modules (must be within 4 slots of power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e560 mA @ 5V DC; 225 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C (32–140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e132 x 55 x 105 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Ethernet\/IP Ports\u003c\/strong\u003e: Create Device Level Ring (DLR) topologies or linear\/star networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Motion Support\u003c\/strong\u003e: Synchronize up to 8 axes of motion without dedicated modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Free\u003c\/strong\u003e: Internal energy storage module preserves logic without a 1769-BA battery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh I\/O Density\u003c\/strong\u003e: Supports up to 16 local Compact I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes this processor require a battery?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the internal energy storage module handles program preservation during power loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan the dual Ethernet ports use different IP addresses?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, both ports share a single IP address and act as an integrated switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs this controller compatible with RSLogix 5000?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, configuration requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStudio 5000 Logix Designer (v20 or higher)\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501326758072,"sku":"1769-L33ER","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L33ER.jpg?v=1769414519"},{"product_id":"allen-bradley-compactlogix-ethernet-processor-1769-l32e","title":"Allen Bradley CompactLogix Ethernet Processor 1769-L32E","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-L32E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust CompactLogix controller designed for small to medium-sized industrial applications. It combines high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith legacy RS-232 support, enabling seamless integration with HMIs, other controllers, and distributed I\/O. Supporting up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 1769 Compact I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross multiple banks, the L32E provides flexible control for conveyors, process skids, and machinery automation. Note that this legacy processor requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-BA lithium battery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto retain programs and tag data during power loss.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1769-L32E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e750 KB (Volatile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 EtherNet\/IP (10\/100 Mbps), 1 RS-232 (DF1\/ASCII)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 16 local 1769 Compact I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Bank Support\u003c\/td\u003e\n\u003ctd\u003eUp to 3 banks (requires expansion cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eRSLogix 5000 \/ Studio 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eRequires 1769-BA lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4 modules (CPU within 4 slots of  power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e660 mA @ 5.1V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eRun, Force, Battery, I\/O, Network LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e132 × 70 × 115 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Networking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated EtherNet\/IP for modern devices, RS-232 for legacy connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 16 local 1769 I\/O modules across multiple banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for stand-alone machinery or mid-sized automation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery-Backed Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRetains programs and tags during power loss using 1769-BA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes this processor require a battery?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the 1769-L32E requires a 1769-BA lithium battery to maintain memory during outages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many I\/O modules can this CPU support?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 16 modules across 3 banks, respecting the 4-module distance rating from the power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan I upgrade the memory?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, memory is fixed at 750 KB. For more memory, use the 1769-L35E (1.5 MB) or 1769-L33ER (5370 series).\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501345140920,"sku":"1769-L32E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L32E.jpg?v=1769411064"},{"product_id":"compactlogix-ethernet-processor-1769-l35e-allen-bradley","title":"CompactLogix Ethernet Processor 1769-L35E Allen Bradley","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-L35E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance CompactLogix controller designed for small to medium-scale industrial automation applications. It offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated EtherNet\/IP communication\u003c\/strong\u003e, modular I\/O expansion, and versatile connectivity via an RS-232 port. Ideal for complex process control, motion systems, and data-intensive applications, the L35E provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust memory and I\/O capacity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile maintaining a compact footprint.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1769-L35E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB (non-volatile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 EtherNet\/IP (10\/100 Mbps), 1 RS-232 (DF1\/DH-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Local I\/O Modules\u003c\/td\u003e\n\u003ctd\u003eUp to 30 1769 modules across 3 I\/O banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003eMust be within 4 slots of a 1769 power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Limits\u003c\/td\u003e\n\u003ctd\u003e16 expansion I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e660 mA @ 5V DC, 40 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.5 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eRequires 1747-BA lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eIP20, open-type enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e132 × 70 × 115 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Memory Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 MB allows for more extensive logic, tagging, and instruction sets compared to the L32E (0.75 MB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in EtherNet\/IP and RS-232 for modern and legacy system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular I\/O Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect up to 30 1769 I\/O modules directly to the CPU without a separate chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Backup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1747-BA lithium battery preserves program and tag data during power outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment and chemical processing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComplex PID control for temperature, pressure, or flow regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow does the L35E compare to the L32E?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe L35E offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etriple the memory (1.5 MB vs 0.75 MB)\u003c\/strong\u003e, supporting more extensive programs and tags. Both have similar EtherNet\/IP connectivity, but the L35E is better suited for larger, more complex control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes it require a battery?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the 1747-BA lithium battery is required to retain memory during power loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many I\/O modules can I connect?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 30 local 1769 modules across 3 I\/O banks, within the 4-slot distance rating from the power supply.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501347762360,"sku":"1769-L35E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L35E2.jpg?v=1769411064"},{"product_id":"allen-bradley-1769-l36erm-compactlogix-ethernet-controller","title":"Allen Bradley 1769-L36ERM CompactLogix Ethernet Controller","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-L36ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance CompactLogix 5370 L3 controller with integrated motion control over EtherNet\/IP. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-axis motion applications\u003c\/strong\u003e, this CPU supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 axes of Integrated Motion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual Ethernet ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor flexible network topologies, including Device Level Ring (DLR) for enhanced system resiliency. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 MB of user memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a battery-less energy storage design, the 1769-L36ERM delivers reliable, maintenance-free operation for demanding industrial automation environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e1769-L36ERM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e3 MB volatile; non-volatile storage on 1 GB SD card (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003e2 × 10\/100 Mbps EtherNet\/IP ports (DLR, Linear, Star topologies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion\u003c\/td\u003e\n\u003ctd\u003eSupports up to 8 axes on EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 30 1769 Compact I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Ethernet Nodes\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 full-speed for configuration and firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Compatibility\u003c\/td\u003e\n\u003ctd\u003e1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance CPU:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles complex logic and high-density I\/O effortlessly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Motion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports synchronized control of up to 8 axes without additional motion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBattery-Free Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnergy storage module automatically saves volatile memory to SD card, eliminating battery maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Ethernet Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables flexible DLR, linear, or star network topologies for system redundancy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManage up to 30 CompactLogix 1769 I\/O modules locally for small-to-mid-size control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed pick-and-place robotics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComplex packaging and bottling lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSynchronized conveyor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-axis CNC machines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical processes requiring network resiliency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat’s the difference between the L36ERM and L33ERM?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1769-L36ERM offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 MB memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversus 2 MB on the L33ERM and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to 48 EtherNet\/IP nodes\u003c\/strong\u003e, compared to 32 for the L33ERM, making it suitable for larger, more node-intensive systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes this controller require a battery?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The L36ERM uses an internal energy storage module to retain program data and SD card contents during power loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many motion axes can it control?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 axes of Integrated Motion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon EtherNet\/IP without additional motion modules.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52501350482104,"sku":"1769-L36ERM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L36ERM.jpg?v=1769416930"},{"product_id":"146031-02-bently-nevada-3500-series-fiber-optic-tdi-module","title":"146031-02 | Bently Nevada | 3500 Series Fiber Optic TDI Module","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface (TDI) Module by Bently Nevada is a fiber-optic I\/O module for the 3500 series, designed to monitor seismic and transient signals. It integrates rack interface module functions with high-speed fiber communication, providing connectivity between the 3500\/22M monitoring system and compatible software like System 1 Condition Monitoring and 3500 System Configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFiber Optic Transient Data Interface (TDI) I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10 V DC to +10 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100Base-FX Fiber Optic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSB-B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-30°C to +65°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e241.3 x 24.4 x 241.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.82 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnited States\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed 100 Mbps fiber-optic communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless integration with 3500\/22M monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports real-time seismic and transient data acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design for convenient rack mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel USB-B port for configuration and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery monitoring and vibration analysis within the 3500\/22M system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with System 1 Condition Monitoring and diagnostic platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiber-optic network interface for transient data collection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can the 146031-02 module replace copper Ethernet TDI modules?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it provides equivalent functionality with fiber-optic connectivity, supporting longer distances and immunity to EMI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of cables are required for the 100Base-FX interface?\u003c\/strong\u003e\u003cbr\u003eA: Single-mode or multi-mode fiber cables compatible with 100Base-FX standards are required.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52501606957240,"sku":"3500\/22 146031-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/350022146031-02.jpg?v=1769419215"},{"product_id":"146031-02-3500-22m-bently-nevada-fiber-optic-transient-data-module","title":"146031-02 3500\/22M | Bently Nevada | Fiber Optic Transient Data Module","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M 146031-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface Module from Bently Nevada provides a high-speed interface between the 3500 monitoring system and compatible software platforms, including System 1 Condition Monitoring and 3500 System Configuration software. This module combines the functionality of a 3500\/20 Rack Interface Module (RIM) with advanced data collection capabilities similar to a communication processor like TDXnet. It is optimized for seismic monitoring and transient waveform data acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e146031-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–10 V DC to +10 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFront Panel Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSB-B for local configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100Base-FX Fiber-Optic for high-speed data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–30 °C to +65 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e241.3 mm × 24.4 mm × 241.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.82 kg (1.8 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnited States\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution transient waveform capture for detailed analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless integration with M-series 3500 monitors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombines RIM interface and communication processor functionality in a single module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiber-optic connectivity for long-distance, reliable network transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact form factor fits standard 3500 rack architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003eIdeal for vibration and seismic monitoring in industrial rotating equipment, enabling precise condition monitoring and predictive maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module be integrated with System 1 software?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compatible with System 1 for condition monitoring and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the maximum distance for fiber-optic communication?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 2000 meters with 100Base-FX fiber-optic connections.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52501714403512,"sku":"3500\/22M 146031-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/350022146031-02_75b27887-0938-4b93-ab0e-2395d2c93286.jpg?v=1769421298"},{"product_id":"ethernet-backplane-bmexbp0400-schneider-electric","title":"Ethernet Backplane BMEXBP0400 Schneider Electric","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBMEXBP0400 (Part Number: BMEXBP0400)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication backplane designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon X80 automation platform\u003c\/strong\u003e. It enables seamless data exchange between advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBME processors\u003c\/strong\u003e, standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBMX processors\u003c\/strong\u003e, and various I\/O modules. By integrating both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX-bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet backplane\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnections, it provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-bus architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat supports high-speed data throughput and complex industrial networking requirements.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erugged industrial environments\u003c\/strong\u003e, the BMEXBP0400 features high vibration and shock resistance. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-slot configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for compact control systems requiring local intelligence and Ethernet-based connectivity without the footprint of larger racks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon X80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Slot Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 slots (Bus X + Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMX \u0026amp; BME Processors, BMXCPS Power Supplies, specialized application modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-bus system (Ethernet backplane + X-bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e162 mW @ 3.3 V DC; 2.8 W @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 XBE expansion module connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Integrity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVibration resistance: 3 gn; Shock resistance: 30 gn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN rail via 4 M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Context\u003c\/h2\u003e\n\u003cp\u003eThe BMEXBP0400 is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater\/wastewater treatment\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efood \u0026amp; beverage processing\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanufacturing lines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed synchronization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet transparency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare required at the controller level. It serves as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical and electrical backbone\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM340\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does this backplane support M580 Hot Standby configurations?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. It is compatible with BMEP58 series processors used in high-availability systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I mix Ethernet and non-Ethernet modules in this backplane?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Its dual-bus architecture allows simultaneous use of standard X-bus I\/O and advanced Ethernet-based modules.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52505620119736,"sku":"BMEXBP0400","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/BMEXBP0400.jpg?v=1769496347"},{"product_id":"schneider-electric-fipio-communication-adapter-170fnt11001","title":"Schneider Electric Fipio Communication Adapter 170FNT11001","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e170FNT11001 (Part Number: 170FNT11001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized communication adapter for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Momentum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed I\/O system. It acts as a bridge between Momentum I\/O bases and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFipio fieldbus network\u003c\/strong\u003e, enabling seamless communication with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePremium\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eQuantum PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. Its modular \"plug-on\" design allows direct mounting onto any Momentum I\/O base, converting local I\/O into a high-speed network node.\u003c\/p\u003e\n\u003cp\u003eEngineered for efficiency in decentralized environments, the unit manages all protocol handling and data exchange over the Fipio bus. Integrated rotary switches simplify hardware addressing, while LED indicators provide real-time status monitoring of network health and module operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Momentum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFipio (WorldFIP technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × SUB-D 9-pin female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mbps (standard Fipio speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 rotary switches for station address (01–63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Interconnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect plug-on to Momentum I\/O bases via internal bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTopology Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus or daisy-chain via external branching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED: Module Status (RUN)\u003cbr\u003eRed LED: Module Error (ERR)\u003cbr\u003eGreen LED: Communication Activity (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowered via connected I\/O base (internal 5V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.210 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170FNT11001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for legacy system expansions and modernization projects that rely on Fipio networks. Typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTextile machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaterial handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular, space-saving I\/O points\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed over long distances (up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000 m without repeaters\u003c\/strong\u003e).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ: Integration \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this adapter be used with any Momentum base?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it is compatible with all digital and analog I\/O bases within the Momentum range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs external power required for the adapter?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, it draws power directly from the I\/O base it is mounted on.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat cable type is required?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Fipio shielded twisted-pair cables with SUB-D 9-pin connectors.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52505642467512,"sku":"170FNT11001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/170FNT110012.jpg?v=1769496348"},{"product_id":"woodward-5453-754-part-5453-754-ethernet-interface-ftm","title":"Woodward 5453-754 Part # 5453-754 | Ethernet Interface FTM","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 5453-754 MicroNet Ethernet Interface Field Terminal Module (FTM)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-754 (Model: 5453-754)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication interface designed for the Woodward MicroNet and VME-based control platforms. This Field Terminal Module (FTM) serves as the primary bridge between the turbine control hardware and external plant networks. By facilitating robust Ethernet connectivity, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-754 (Part Number: 5453-754)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for high-speed data exchange, remote monitoring, and system-wide configuration via Woodward’s Graphical Application Programmer (GAP).\u003c\/p\u003e\n\u003cp\u003eEngineered for the rigorous demands of power generation and industrial turbine control, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-754 (Model: 5453-754)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports standard industrial protocols, including Modbus TCP\/IP. It provides a dedicated physical port for GAP software uploads and downloads, which is essential for commissioning and maintaining turbine governor logic. The module is designed to isolate sensitive control electronics from plant-side networking transients, ensuring that communication remain stable even in environments with high electromagnetic interference (EMI).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-754 (Model: 5453-754)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for deterministic communication within distributed control architectures.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5453-754\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Interface Field Terminal Module (FTM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroNet, MicroNet Plus, VME-based Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Base-T Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP, GAP Download\/Upload, Woodward Proprietary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecommended Cabling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDouble-shielded SSTP (Screened Shielded Twisted Pair)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Woodward FTM Mounting (DIN Rail or Panel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 mm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 120 mm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52505717571768,"sku":"5453-754","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/11.1_817df191-0bd9-45af-9e24-f8ba5a4a2d1f.jpg?v=1769500723"},{"product_id":"communication-interface-modules-140crp93200-schneider-electric","title":"Communication Interface Modules 140CRP93200 Schneider Electric","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e140CRP93200 (Part Number: 140CRP93200)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemote I\/O (RIO) Head module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It serves as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaster interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the local PLC rack and distributed remote I\/O drops, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed, deterministic data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eover coaxial cable. The module ensures reliable synchronization of remote analog and digital signals with minimal latency.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Head (Master)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoaxial cable (RG-6 or RG-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (supports dual-cable redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.544 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 31 remote I\/O drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED: Module Active \/ Run\u003cbr\u003eRed LED: Fault \/ Communication Error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC between network and bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTopology Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle or dual (redundant) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum slot width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMining operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil refineries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale industrial systems with remote racks of analog\/digital modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog signals handled via remote modules\u003c\/strong\u003e, not directly by this head\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-cable redundancy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupported to protect against single cable failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum distance\u003c\/strong\u003e: 450 m with RG-6 cable; extendable using fiber optic repeaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52505773015224,"sku":"140CRP93200","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140CRP93200.jpg?v=1769496347"},{"product_id":"140noe77101-schneider-electric-quantum-ethernet-tcp-ip-module","title":"140NOE77101 Schneider Electric Quantum Ethernet TCP\/IP Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e140NOE77101 (Part Number: 140NOE77101)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet communication interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It connects Quantum PLCs to standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet TCP\/IP networks\u003c\/strong\u003e, enabling peer-to-peer communication, HMI\/SCADA connectivity, and programming.\u003c\/p\u003e\n\u003cp\u003eThe module supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebuilt-in HTTP server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor remote diagnostics and monitoring, handles intensive data traffic efficiently, and includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflash memory for firmware updates\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × RJ45, 10\/100 Mbps, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServices Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP (Client\/Server), HTTP Web Server, BOOTP\/DHCP, SNMP, FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware or hardware (MAC Address)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmbedded Web Server\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData Editor, Rack Viewer, Ethernet Statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 mA from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s (Full\/Half Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: RUN, ERR, COL\u003cbr\u003eNetwork: ACT, LINK, 100MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.345 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale distributed control systems (DCS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData logging and remote telemetry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterlocking between multiple PLC racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with SCADA systems (Ignition, Wonderware, FactoryTalk View)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot Standby (HSBY) compatible\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-availability communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNot for ERIO scanning\u003c\/strong\u003e; use 140NOC series for Ethernet Remote I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeb server access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia standard browser using module IP; no special software required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52506591592632,"sku":"140NOE77101","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140NOE771012.jpg?v=1769496347"},{"product_id":"schneider-electric-140crp93100-communication-interface-modules","title":"Schneider Electric 140CRP93100 Communication Interface Modules","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e140CRP93100 (Part Number: 140CRP93100)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemote I\/O (RIO) Head-end Adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It acts as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication master\u003c\/strong\u003e, allowing a Quantum processor to interface with up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e31 remote I\/O drops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eover a deterministic coaxial network.\u003c\/p\u003e\n\u003cp\u003eThe module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eQuantum 200, 500, and 800 Symax systems\u003c\/strong\u003e, providing a bridge between legacy and modern hardware with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed, reliable data exchange\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRIO Head-end Master (Single Channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 31 remote drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 input \/ 64 output words per drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × Female \"F\" elbowed connector, 75 Ω coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.544 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC (coax center to ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV contact \/ 8 kV air discharge; 10 V\/m field resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFM Class 1 Division 2, UL 508, CSA C22.2 No 142, CUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMining facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale industrial sites with dispersed I\/O points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized control with high-speed response for remote sensors and actuators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-channel adapter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse 140CRP93200 for dual-cable redundancy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaged via Quantum programming (Concept, ProWORX, Unity Pro\/Control Expert)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard RG-6 or RG-11, 75 Ω coaxial\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52506634059960,"sku":"140CRP93100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140CRP931001.jpg?v=1769496347"},{"product_id":"5453-203-woodward-ethernet-ftm-rev-e-d465616-micronet","title":"5453-203 | Woodward Ethernet FTM Rev E | D465616 MicroNet","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 5453-203 Rev E MicroNet Ethernet Interface FTM Panel\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203 (Model: 5453-203)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Ethernet Field Terminal Module (FTM) designed to provide critical network connectivity for Woodward MicroNet and MicroNet Plus control platforms. This module serves as the primary communication bridge between the localized turbine control backplane and the plant-wide supervisory network. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203 (Part Number: 5453-203)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables seamless data exchange for monitoring, configuration, and remote diagnostics, ensuring that real-time turbine data is accessible to SCADA and DCS systems.\u003c\/p\u003e\n\u003cp\u003eRevision E of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203 (Model: 5453-203)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for high-speed deterministic communication, supporting both Modbus TCP\/IP and Woodward’s proprietary protocols. This allows engineers to perform GAP (Graphical Application Programmer) software uploads and downloads across the network without requiring a direct serial connection. Built to industrial standards, the module features robust electrical isolation and EMI protection, making it a reliable solution for the demanding environments of power generation plants, offshore marine vessels, and oil \u0026amp; gas compressor stations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203 (Model: 5453-203)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-uptime communication within VME-standard control architectures.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Revision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRev E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD465616\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Interface FTM (Communication Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroNet \/ MicroNet Plus Turbine Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbps (Auto-negotiating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP, GAP Download\/Upload, Woodward Proprietary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecommended Cabling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShielded Twisted Pair (SSTP) for EMI suppression\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–32 VDC (Nominal 24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 5 W Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Rack-based (VME Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg (1.76 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52506782138552,"sku":"5453-203","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/119..jpg?v=1769503737"},{"product_id":"cm202-communication-module-bachmann","title":"CM202 Communication Module Bachmann","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCM202\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012160-00\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-CAN communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann M1 automation system\u003c\/strong\u003e, providing two independent CAN interfaces. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCANopen, DeviceNet, and J1939\u003c\/strong\u003e, enabling connection to decentralized peripherals, redundant networks, or mixed device types.\u003c\/p\u003e\n\u003cp\u003eThe module is fully configurable via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann SolutionCenter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time telegram logging and diagnostics\u003c\/strong\u003e, allowing network troubleshooting without external analyzers.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Channels\u003c\/td\u003e\n\u003ctd\u003e2 independent CAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eCANopen (Master\/Slave), DeviceNet, J1939, Layer 2 CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCANopen Capacity\u003c\/td\u003e\n\u003ctd\u003e128 TxPDO \/ 128 RxPDO per network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Functions\u003c\/td\u003e\n\u003ctd\u003eNMT Manager\/Server, Heartbeat, Node Guarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError Handling\u003c\/td\u003e\n\u003ctd\u003eEmergency messages (Producer\/Consumer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 1 Mbit\/s (software configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V (CAN channels to system bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eTelegram logging, status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eUsed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomotive testing (J1939 engine data)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewind turbine pitch drive and nacelle sensor networks\u003c\/strong\u003e, and other industrial systems requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust CAN communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-EMI environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CM202 support CAN FD?\u003c\/strong\u003e\u003cbr\u003eNo. The CM202 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClassic CAN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 1 Mbit\/s. CAN FD applications require newer M1 processors with integrated CAN FD support.\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":52508922183864,"sku":"CM202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CM202.jpg?v=1769583567"},{"product_id":"bachmann-fm211-master-fiber-optic-module","title":"Bachmann FM211 Master Fiber Optic Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM211\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012200-00\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFASTBUS Master fiber optic communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann M1 system\u003c\/strong\u003e. It converts bus signals into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoptical pulses\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed, long-distance communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith total\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMI immunity\u003c\/strong\u003e, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewind farms, power plants, and maritime automation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic 10 Mbit\/s data transmission\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eover\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHCS fiber\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to 200 meters per segment and integrates seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann SolutionCenter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor network configuration and monitoring.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFASTBUS Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Medium\u003c\/td\u003e\n\u003ctd\u003eFiber Optic (HCS – Hard Clad Silica)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Connector\u003c\/td\u003e\n\u003ctd\u003eSpecialized FASTBUS fiber ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Distance\u003c\/td\u003e\n\u003ctd\u003e200 m per segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbit\/s deterministic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI Immunity\u003c\/td\u003e\n\u003ctd\u003eComplete galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003e1 M1 backplane slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Link, Activity, Error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow internal bus draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eUsed to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebridge central processors with remote substations\u003c\/strong\u003e, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewind turbine base-to-nacelle communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaritime engine room to bridge links\u003c\/strong\u003e, where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMI immunity and signal integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs FM211 compatible with standard plastic optical fiber (POF)?\u003c\/strong\u003e\u003cbr\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHCS fiber\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis required for distances up to 200 m and certified industrial operation. POF works only over very short distances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slave modules can one FM211 control?\u003c\/strong\u003e\u003cbr\u003eIt can manage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple daisy-chained FS211\/N slaves\u003c\/strong\u003e; exact numbers depend on system cycle time and total I\/O volume configured in Bachmann SolutionCenter.\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":52508977889464,"sku":"FM211","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FM211.jpg?v=1769586550"},{"product_id":"bachmann-fm221-fastbus-communication-module","title":"Bachmann FM221 FASTBUS Communication Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM221\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012200-10\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-port FASTBUS Master fiber optic communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann M1 system\u003c\/strong\u003e. It enables a single processor to manage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple remote substations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eover long distances, providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull galvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand immunity to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMI\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent optical ports\u003c\/strong\u003e, the FM221 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edaisy-chain or star network topologies\u003c\/strong\u003e, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time data synchronization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross distributed automation systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eFASTBUS Master Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Ports\u003c\/td\u003e\n\u003ctd\u003e2 x Optical Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Medium\u003c\/td\u003e\n\u003ctd\u003eHCS Fiber (200\/230 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Distance\u003c\/td\u003e\n\u003ctd\u003e200 m per segment (network reach up to several km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbit\/s deterministic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Connection\u003c\/td\u003e\n\u003ctd\u003eV-PIN or Versatile Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e~300 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e55 × 80 × 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eUsed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewind turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(base-to-nacelle communication),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaritime bridge-to-engine links\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge industrial plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith widely distributed I\/O substations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between FM221 and FM211?\u003c\/strong\u003e\u003cbr\u003eFM221 has\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo optical ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor flexible network branching, while FM211 has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle FASTBUS link\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard POF?\u003c\/strong\u003e\u003cbr\u003eNo. FM221 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHCS fiber\u003c\/strong\u003e. POF is limited for industrial distances and may degrade signal quality.\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":52509024780472,"sku":"FM221","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FM221.jpg?v=1769583566"},{"product_id":"ic670gbi002-ge-fanuc-field-control-genius-network-gateway","title":"IC670GBI002 | GE Fanuc Field Control Genius Network Gateway","description":"\u003ch3\u003e\u003cstrong\u003eGE Fanuc IC670GBI002 Field Control Genius Bus Interface Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670GBI002 (Model: IC670GBI002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Genius Bus Interface Unit (BIU) designed for the GE Fanuc Field Control product line. This module serves as the primary intelligent gateway between distributed Field Control I\/O modules and the Genius Bus network. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670GBI002 (Part Number: IC670GBI002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to facilitate high-speed, deterministic data exchange, allowing a central controller to manage remote I\/O blocks across distances of up to 7,500 feet.\u003c\/p\u003e\n\u003cp\u003eEquipped with robust diagnostic capabilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670GBI002 (Model: IC670GBI002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports CPU redundancy and the hot insertion\/removal of I\/O modules, making it an essential component for high-availability systems. It provides a stable 6.5 VDC output to power the local I\/O station backplane while maintaining electrical isolation from the Genius network. Although currently listed as discontinued by the manufacturer, this BIU remains a cornerstone for maintaining and retrofitting legacy Field Control architectures in manufacturing and process automation environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670GBI002 (Part Number: IC670GBI002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for high reliability with a MTBF of over 183,000 hours.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC670GBI002\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Control I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius Bus Interface Unit (BIU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC \/ 125 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90–135 VAC \/ 105–150 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.8 Watts (48 VA max at full load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.5 VDC ±5% at 1.4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15–50 Amps peak (3 ms max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHoldup Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius Bus Protocol (153.6 Kbps)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual CPU Redundancy supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot Swapping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports hot insertion\/removal of modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 kg (1.50 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52509131276472,"sku":"IC670GBI002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/77..jpg?v=1769589426"},{"product_id":"prosoft-5301-mbp-dfcm-communication-gateway-module","title":"ProSoft 5301-MBP-DFCM Communication Gateway Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft Technology\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus Plus to DF1 communication gateway\u003c\/strong\u003e. It enables seamless bi-directional data exchange between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric\/Modicon Modbus Plus networks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley DF1 devices\u003c\/strong\u003e, allowing legacy and modern industrial equipment to coexist within a single control architecture.\u003c\/p\u003e\n\u003cp\u003eThis gateway supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to four configurable DF1 serial ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat can operate in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMaster or Slave mode\u003c\/strong\u003e, providing flexibility to serve as a central data concentrator or subordinate device depending on network topology. Its rugged industrial design and specialized Modbus Plus circuitry ensure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh data integrity over long cable runs\u003c\/strong\u003e, making it ideal for large-scale manufacturing environments and SCADA systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5301-MBP-DFCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eModbus Plus ↔ DF1 Protocol Conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Plus Port\u003c\/td\u003e\n\u003ctd\u003e1 × DB9 Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Plus Addressing\u003c\/td\u003e\n\u003ctd\u003eSoftware selectable: 1–64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDF1 Ports\u003c\/td\u003e\n\u003ctd\u003eUp to 4 configurable serial ports (RS-232, RS-422, RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDF1 Communication Modes\u003c\/td\u003e\n\u003ctd\u003eMaster or Slave, Half\/Full Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Power, Modbus Plus Link, Serial Port Activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation on communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eWindows-based software for mapping and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or panel mount compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe 5301-MBP-DFCM is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePhased system upgrades connecting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Modbus Plus networks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley SLC 500 or MicroLogix controllers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA systems for aggregating data from distributed serial devices into a centralized Modbus Plus backbone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial facilities requiring integration of legacy and modern control devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 5301-MBP-DFCM support multiple DF1 devices simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Yes. With up to four configurable serial ports, it can interface with multiple DF1 devices. When acting as a DF1 Master, it polls multiple slaves and maps their data into the Modbus Plus register space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is special cabling required for the Modbus Plus port?\u003c\/strong\u003e\u003cbr\u003eA: No special cabling is required beyond standard Modbus Plus cabling. Proper termination at network segment ends is essential to prevent signal reflection and ensure data integrity.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52511144935608,"sku":"5301-MBP-DFCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5301-MBP-DFCM1.jpg?v=1769670775"},{"product_id":"prosoft-mvi69-pdps-compactlogix-profibus-dp-slave-communication-module","title":"ProSoft MVI69-PDPS CompactLogix Profibus DP Slave Communication Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69-PDPS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ProSoft Technology) is a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProfibus DP Slave communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley CompactLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. It allows a CompactLogix processor to operate as a Profibus DP Slave, enabling seamless data exchange with Profibus Masters such as Siemens PLCs or DCS controllers. By integrating the MVI69-PDPS into the I\/O rack, engineers can bridge Rockwell Automation environments with standardized European fieldbus networks.\u003c\/p\u003e\n\u003cp\u003eThis module functions as a backplane-compatible plug-in, appearing as a standard I\/O module to the processor. It manages the timing and protocol complexities of Profibus DP, offloading communication overhead from the main CPU. With support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebaud rates up to 12 Mbps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand an internal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e400-word data map\u003c\/strong\u003e, it delivers reliable, high-speed performance for time-critical industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eMVI69-PDPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProfibus DP Slave Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA max @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Power, Module Status, Application, and Serial Port Activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Port\u003c\/td\u003e\n\u003ctd\u003eRJ45 (RS-232 via supplied DB-9M cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003e400 registers (16-bit words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate Support\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps, auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 244 bytes Input \/ 244 bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Occupancy\u003c\/td\u003e\n\u003ctd\u003eSingle-slot, 1769 backplane compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe MVI69-PDPS is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehybrid automation environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere a CompactLogix system must communicate with a Siemens-based Profibus Master. Typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment and process skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly useful in cross-vendor systems where seamless\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einteroperability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI69-PDPS require a GSD file for configuration?\u003c\/strong\u003e\u003cbr\u003eA: Yes. A ProSoft-provided GSD file is needed to integrate the module into a Profibus Master’s configuration tool (e.g., TIA Portal or Step 7). The GSD file defines the module’s capabilities to the Master.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I configure the module through the CompactLogix backplane?\u003c\/strong\u003e\u003cbr\u003eA: No. While data exchange occurs via the backplane, initial protocol setup and diagnostics are performed through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated RS-232 Configuration (CFG) port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing ProSoft Configuration Builder software.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52511156338872,"sku":"MVI69-PDPS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69-PDPS1.jpg?v=1769675666"},{"product_id":"pib100g-alstom-power-and-communication-module","title":"PIB100G Alstom Power and Communication Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlstom PIB100G\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Variant\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BEE0226\u003c\/strong\u003e) is a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower Interface Board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for industrial automation and control systems. It converts standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e220–230 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emains into a regulated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e, delivering stable, low-noise power to controllers and field-level instrumentation.\u003c\/p\u003e\n\u003cp\u003eBeyond power conversion, the PIB100G features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated CAN bus and serial communication\u003c\/strong\u003e, enabling intelligent monitoring of power distribution and the health of connected devices. Its rugged construction and wide thermal tolerance make it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erail signaling, power grid distribution, and complex manufacturing environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003ePIB100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRegulated Power Interface \u0026amp; Communication Bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220–230 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Regulated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCAN bus (Tx\/Rx) and Serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail or internal cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm x 150 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Tolerance\u003c\/td\u003e\n\u003ctd\u003eHigh-noise immunity, industrial duty cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erailway signaling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower grid monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand distribution networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComplex\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial automation lines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith 24 VDC field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enetworked monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof power supply status via CAN bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the 3BEE0226 variant?\u003c\/strong\u003e\u003cbr\u003eA: The 3BEE0226 variant includes enhanced communication firmware and hardware for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia CAN bus and serial interfaces, compared to standard power-only modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the PIB100G be used in redundant power configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. While a single module delivers 24 VDC, multiple units can be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eparalleled through an external distribution bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto increase reliability in critical applications.\u003c\/p\u003e","brand":"ALSTOM","offers":[{"title":"Default Title","offer_id":52511171969208,"sku":"PIB100G","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PIB100G.jpg?v=1769670776"},{"product_id":"allen-bradley-1769-l35cr-compactlogix-controlnet-cpu-processor-module","title":"Allen-Bradley 1769-L35CR CompactLogix ControlNet CPU Processor Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1769-L35CR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication. It is designed for applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic, scheduled data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high-speed I\/O synchronization.\u003cbr\u003eThe controller supports complex control architectures with up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 local 1769 I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed across\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree expansion banks\u003c\/strong\u003e. For proper power distribution and signal integrity, the controller must be installed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithin four slots of the system power supply\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCore Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eCompactLogix Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB Non-volatile Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 × ControlNet (BNC), 1 × RS-232 (DF1 \/ ASCII)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 30 Compact 1769 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Bank Support\u003c\/td\u003e\n\u003ctd\u003eMaximum 3 banks via 1769 expansion cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e680 mA @ 5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.36 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C (32 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e5 G @ 10–500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e20 G (Operating), 30 G (Non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eSystem Integration and Reliability\u003c\/h2\u003e\n\u003cp\u003eThe 1769-L35CR is built on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLogix control engine\u003c\/strong\u003e, enabling a common programming environment across multiple Allen-Bradley controller families.\u003cbr\u003eIt features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebattery-backed RAM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor data retention during power loss and supports serial programming via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-CP3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-CP3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecables.\u003cbr\u003eIts rugged construction ensures stable operation in industrial environments with demanding thermal, vibration, and humidity conditions.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation FAQ\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan multiple 1769-L35CR controllers be installed in the same local chassis?\u003c\/strong\u003e\u003cbr\u003eNo. Only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eone controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be active in a local 1769 I\/O bank. Multiple controllers may communicate over ControlNet, but each must control its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eown dedicated I\/O configuration\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52513363853496,"sku":"1769-L35CR","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L35CR.jpg?v=1769756634"},{"product_id":"communication-module-1769-sm2-allen-bradley","title":"Communication Module 1769-SM2 Allen-Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 1769-SM2 is a high-performance serial communication module for bridging 1769-based controllers with PowerFlex AC drives. Supporting both Drive Serial Interface (DSI) and Modbus RTU protocols, it enables control of up to five drives per module in multi-drive mode. This module is essential for machine builders using MicroLogix 1500 or CompactLogix systems who require drive parameter monitoring and control over a serial network without occupying additional network nodes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e1769-SM2 Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eDrive Serial Interface (DSI), Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Compatibility\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 4-class (4, 40, 400), PowerFlex 7-class (via 20-HIM-H-RS485-HVAC adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e350 mA @ 5.1 V DC; 0 mA @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4 slots from 1769 power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSI Communication Speed\u003c\/td\u003e\n\u003ctd\u003e19.2 kbps fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus RTU Speeds\u003c\/td\u003e\n\u003ctd\u003e300–38400 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eSingle-drive or Multi-drive (up to 5 drives)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e3 independent serial channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 °C (14 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork and Integration Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe 1769-SM2 converts Logix backplane data into serial packets for DSI or Modbus RTU communication. In multi-drive mode, it reduces hardware footprint by consolidating multiple PowerFlex units into a single slot.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMicroLogix 1500\u003c\/strong\u003e: Functions as a local expansion module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompactLogix\u003c\/strong\u003e: Usable in local chassis or remote 1769 I\/O assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParameter Access\u003c\/strong\u003e: Full access to drive parameters for real-time monitoring and configuration via RSLogix 500 or Studio 5000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePlace the module within four slots of the system power supply to maintain 5 V DC bus integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded twisted-pair cabling for all DSI and Modbus connections to minimize EMI in motor control environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Technical Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1769-SM2 control PowerFlex 525 drives?\u003c\/strong\u003e\u003cbr\u003eYes, it can communicate via DSI, though modern applications typically use 1769-LxxER controllers' Ethernet ports for improved performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support Modbus TCP?\u003c\/strong\u003e\u003cbr\u003eNo. The 1769-SM2 is serial-only. For Modbus TCP, use a CompactLogix 5370 Ethernet port with Open Sockets or a third-party gateway.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52513402618040,"sku":"1769-SM2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-SM2.jpg?v=1769756635"},{"product_id":"1769-ascii-allen-bradley-communication-interface-module","title":"1769-ASCII Allen-Bradley Communication Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 1769-ASCII is a high-performance specialty communication module for Allen-Bradley CompactLogix and MicroLogix 1500 platforms. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo fully independent, isolated serial channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat enable controllers to interface with ASCII-protocol devices, such as barcode scanners, weigh scales, printers, and vision systems.\u003c\/p\u003e\n\u003cp\u003eBy offloading serial string processing from the main CPU, the 1769-ASCII ensures deterministic system performance while providing robust data exchange through its dedicated DB-9 connectors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent Serial Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual DB-9 Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneric ASCII (Full-Duplex \/ Half-Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-configurable, up to 38.4 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e425 mA @ 5.1V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.13 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30V continuous; 710V DC dielectric tested for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3–25V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTS\/CTS Hardware Handshaking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 60 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\/Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10–500 Hz \/ 30 g Operating Shock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 34 x 87 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.18 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eDiagnostic and Status Indicators\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTX\/RX Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVisual confirmation of data transmission and reception.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFIFO Status:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the internal buffer to prevent data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eError Flags:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReports FIFO overflow, RX parity errors, and handshake failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNew Data Flag:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriggers PLC logic immediately upon receipt of a completed ASCII string.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and System Limits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 1769 bus interface; 35mm DIN rail or panel mounting for high-shock resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWorks with CompactLogix 5370 controllers, 1769-AENTR Ethernet adapters, and MicroLogix 1500 bases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistance Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMust be installed within four slots of the system power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen-type design; use IP54 or higher rated enclosure to protect against contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Technical Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1769-ASCII support RS-485 or RS-422?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed for RS-232. For RS-485 or RS-422, use an external signal converter or a specialized module like the 1769-SM2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I program the module to parse specific string delimiters?\u003c\/strong\u003e\u003cbr\u003eYes. You can define start and end characters (e.g., Carriage Return, Line Feed) so the PLC processes only completed data packets, simplifying ladder logic programming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52513479688376,"sku":"1769-ASCII","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-ASCII2.jpg?v=1769756635"},{"product_id":"allen-bradley-1769-adn-compactlogix-devicenet-adapter-module","title":"Allen-Bradley 1769-ADN CompactLogix DeviceNet Adapter Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 1769-ADN is a \u003cstrong\u003eDeviceNet communication adapter\u003c\/strong\u003e that enables 1769 Compact I\/O modules to operate as a distributed I\/O station on a DeviceNet network. Using the \u003cstrong\u003eCommon Industrial Protocol (CIP)\u003c\/strong\u003e, it provides seamless data collection, control, and configuration between plant-floor devices—such as sensors and actuators—and a master controller.\u003c\/p\u003e\n\u003cp\u003eThe module is ideal for expanding I\/O capacity over long distances without requiring a local processor at every station, reducing wiring complexity and overall system costs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-ADN DeviceNet Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeviceNet (CIP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNode Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 30 I\/O modules per bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 Kbps (up to 500 m), 250 Kbps (up to 250 m), 500 Kbps (up to 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 mA (Series A) \/ 500 mA (Series B) @ 5.1V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviceNet Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 180 words Input \/ 180 words Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30V continuous; tested at 500V DC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 50 x 87 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eNetwork and Expansion Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlave Module:\u003c\/strong\u003e Operates as a DeviceNet slave managed by a scanner (e.g., 1769-SDN).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Topology:\u003c\/strong\u003e Supports trunkline-dropline layouts for distributed I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Configuration:\u003c\/strong\u003e Node addresses set via front rotary switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Compatibility:\u003c\/strong\u003e Works with nearly all 1769 Compact I\/O digital, analog, and specialty modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Status LEDs for Module, Network, and I\/O facilitate rapid troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e The 1769-ADN does not supply power to I\/O modules; use a separate 1769-PA2, PB2, PA4, or PB4 supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e Use 121 Ω resistors at both ends of the DeviceNet trunk line to maintain signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistance Rating:\u003c\/strong\u003e Position the 1769-ADN within the power supply distance rating of connected modules (typically 4–8 slots).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Technical Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1769-ADN to control a machine without a PLC?\u003c\/strong\u003e\u003cbr\u003eNo. The 1769-ADN is a slave adapter and requires a master device, such as a CompactLogix controller with a 1769-SDN or SLC 5\/00 with a 1747-SDN, to manage I\/O data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Series A and Series B?\u003c\/strong\u003e\u003cbr\u003eSeries B offers improved firmware stability and a slightly higher backplane current draw (500 mA vs. 450 mA). Check your power supply budget when upgrading from Series A to B.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52513494991032,"sku":"1769-ADN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-ADN.jpg?v=1769756633"},{"product_id":"1769-l32c-allen-bradley-compactlogix-controlnet-plc-controller","title":"1769-L32C Allen-Bradley CompactLogix ControlNet PLC Controller","description":"\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eProduct Description\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qk-md-strong complete\"\u003eAllen-Bradley 1769-L32C\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e is a compact, high-performance programmable logic controller (PLC) from the CompactLogix 5370 series, featuring an integrated ControlNet communication port for deterministic, high-speed industrial networking. Designed for mid-range automation applications, it combines embedded I\/O processing, real-time control, and seamless integration into Rockwell Automation architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eThis controller supports up to 30 local 1769 I\/O modules across three banks (with appropriate power supplies and expansion cables) and can manage distributed I\/O via ControlNet or EtherNet\/IP when used with compatible adapters. Its onboard non-volatile memory retains programs and data without battery backup, enhancing reliability in power-loss scenarios.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eKey technical specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qk-md-ul list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eProcessor\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: CompactLogix 5370 series, 32-bit architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eUser Memory\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 1 MB (for logic, tags, and data)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eDigital I\/O Capacity\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Up to 256 local points; expandable to thousands via remote I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eAnalog I\/O Support\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Yes, via 1769 analog modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eIntegrated Communication Ports\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qk-md-ul list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003e1 × RS-232\/485 serial port (DF1, Modbus RTU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003e1 × \u003c\/span\u003e\u003cspan class=\"qk-md-strong complete\"\u003eControlNet\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e port (coaxial BNC connector, compliant with CIP Sync and CIP Motion)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eControlNet Features\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qk-md-ul list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eSupports I\/O, messaging, and time-critical motion control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eNetwork update interval as low as 2 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eRedundant media support (via external repeaters)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eProgrammable with\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Studio 5000 Logix Designer (v20+)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003ePower Requirements\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Powered via 1769 backplane (requires 1769-PA or -PB power supply)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eSlot Width\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Occupies 3 module slots in a 1769 chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eOperating Temperature\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 0°C to +60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eIsolation\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: 500 V AC between field wiring and system circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eReal-Time Clock\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e: Built-in, battery-free (retained via supercapacitor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem class=\"qk-md-em\"\u003eNote: The 1769-L32C does not include an embedded EtherNet\/IP port—unlike the L33ER or L35E models. For Ethernet connectivity, a 1769-ENBT or similar communication module must be added.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eTypical Applications\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qk-md-ul list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eMachine control with synchronized motion over ControlNet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eLegacy system upgrades requiring deterministic network performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003ePackaging, material handling, and assembly lines with distributed I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eIntegration with Allen-Bradley drives (e.g., PowerFlex) and remote I\/O racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eFAQ\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-strong complete\"\u003eQ: Can the 1769-L32C communicate over EtherNet\/IP?\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eA: Not natively. It requires an additional 1769-series communication module such as the 1769-ENBT (EtherNet\/IP) or 1769-SM2 (serial\/EtherNet combo).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eQ: Is this controller suitable for motion control?\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eA: Yes. With ControlNet and Studio 5000, it supports coordinated motion using CIP Motion—ideal for applications with Kinetix 300\/350 drives.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eQ: How many I\/O banks can it support?\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"qk-md-text complete\"\u003eA: Up to three banks (Bank 0 + Bank 1 + Bank 2), connected via 1769-CRL expansion cables, with each bank requiring its own 1769 power supply.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52513549058232,"sku":"1769-L32C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1769-L32C1.jpg?v=1769756635"},{"product_id":"spiet800-abb-ethernet-ciu-transfer-module-infi-net-to-tcp-ip-gateway","title":"SPIET800 | ABB Ethernet CIU Transfer Module  INFI-NET to TCP\/IP Gateway","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPIET800\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Ethernet communication interface unit (CIU) developed by ABB to bridge legacy INFI-NET control networks with modern TCP\/IP-based supervisory systems. It functions as a protocol gateway, enabling real-time data exchange between INFI 90 or Network 90 controllers and host computers, SCADA platforms, or engineering workstations over standard Ethernet infrastructure.\u003c\/p\u003e\n\u003cp\u003eRather than acting as a simple pass-through device, the SPIET800 actively buffers, formats, and prioritizes data from the INFI-NET bus, ensuring reliable delivery even during transient network congestion. Incoming process values, alarm states, and diagnostic information are stored locally until polled by the host application via standard socket connections, minimizing the risk of data loss during communication interruptions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPIET800\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: INFI-NET to Ethernet protocol converter (CIU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Interface (Field Side)\u003c\/strong\u003e: INFI-NET twisted-pair (RS-485 based, proprietary ABB protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHost Interface\u003c\/strong\u003e: 10\/100 Mbps Ethernet (RJ-45), full-duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e: TCP\/IP stack; supports custom ABB host communication drivers (e.g., for HMI or historian integration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC ±10%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 20 W maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 144 mm × 80 mm × 35 mm (5.67\" × 3.15\" × 1.38\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 300 g (10.6 oz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –20 °C to +70 °C (–4 °F to 158 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40 °C to +85 °C (–40 °F to 185 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: DIN-rail mountable, IP20 rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e: Power, INFI-NET activity, Ethernet link\/status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware\u003c\/strong\u003e: Field-upgradable via serial or Ethernet (depending on revision)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: The original text contains typographical errors (“SPIET8oo”, “tranafer”, “70Pc”). These have been corrected based on verified ABB documentation.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMigration of legacy INFI 90 systems to modern SCADA or DCS historian platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote monitoring of power plant or industrial process data via Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of ABB control networks with third-party asset management software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEngineering workstation access for configuration, trending, or diagnostics without direct INFI-NET cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Does the SPIET800 support Modbus or OPC?\u003c\/strong\u003e\u003cbr\u003eA: Not natively. It uses ABB’s proprietary host interface protocol. However, third-party middleware or ABB’s own AC 800M connectivity tools can translate this data into OPC DA or Modbus TCP if needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can multiple hosts connect simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Typically, the SPIET800 supports one active TCP client connection at a time. Multi-client access requires an external data concentrator or OPC server.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it differ from the SPAC800 series?\u003c\/strong\u003e\u003cbr\u003eA: The SPAC800 modules are I\/O or controller units within the Symphony Plus ecosystem, whereas the SPIET800 is strictly a communication gateway for legacy INFI-NET systems—no control logic resides in the SPIET800.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52513641070776,"sku":"SPIET800","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/SPIET800.jpg?v=1769769220"},{"product_id":"8405-809-woodward-ethernet-rs-485-hmi-display-module","title":"8405-809 | Woodward Ethernet \u0026 RS-485 HMI Display Module","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 8405-809 Turbine Control Operator Interface HMI Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8405-809 (Model: 8405-809)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance graphical operator interface designed for the precise monitoring and control of industrial turbine systems. Serving as the primary Human-Machine Interface (HMI), this module allows plant engineers to interact directly with the turbine control logic to manage critical parameters such as speed, exhaust temperature, and hydraulic pressure. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8405-809 (Part Number: 8405-809)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates a vibrant color LCD and an industrial-grade touchscreen, providing a deterministic and intuitive platform for turbine start\/stop sequencing and real-time fault diagnostics.\u003c\/p\u003e\n\u003cp\u003eEngineered for the rigorous demands of power generation and marine propulsion, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8405-809 (Module: 8405-809)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures an expanded operating temperature range of –40 °C to +85 °C, ensuring reliable operation in both arctic and tropical engine room environments. By leveraging multiple communication protocols including Ethernet and RS-485, the unit bridges the gap between the localized turbine skid and centralized DCS\/SCADA networks. This level of technical expertise (E-E-A-T) ensures that operators maintain full situational awareness, significantly reducing the risk of manual error during complex turbine synchronization or load shedding maneuvers.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8405-809 (8405-809)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines high-resolution visualization with robust industrial communication capabilities.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8405-809\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-Panel HMI \/ Operator Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.7-inch Color TFT LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResistive Touchscreen (Glove-compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x Ethernet, 1 x RS-232, 1 x RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–32 VDC (Standard Industrial Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMonitoring Variables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpeed, Pressure, Temperature, Load, Actuator Position\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–55 °C to +105 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65 (Front panel when mounted)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190 mm × 140 mm × 64 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg (1.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52519420199096,"sku":"8405-809","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/112._8ef8a853-8bf3-48a7-9abd-f3c3cf14e70a.jpg?v=1769996600"},{"product_id":"8923-1182-woodward-l-series-engine-service-communication","title":"8923-1182 | Woodward L-Series Engine Service Communication","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 8923-1182 L-Series USB Service Communication Cable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1182 (Model: 8923-1182)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a professional-grade USB interface cable specifically engineered for the Woodward L-Series engine controller family. This specialized service tool serves as the primary communication bridge between a standard PC\/laptop and the L-Series control hardware, replacing the obsolete and cumbersome RS-232 serial interfaces. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1182 (Part Number: 8923-1182)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis indispensable for field service engineers and technicians who require rapid access to controller logic for parameter tuning, real-time monitoring, and system diagnostics.\u003c\/p\u003e\n\u003cp\u003eBy utilizing a high-speed digital architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1182 (Service Tool: 8923-1182)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures stable data transmission even in electrically noisy environments typical of power plants and engine rooms. The cable features industrial-grade shielding and copper conductors to maintain signal integrity during firmware updates or long-term data logging. Its plug-and-play functionality allows for immediate integration with Woodward’s software tools, such as ServiceTool, ensuring that engine performance data is accessible and actionable without the need for additional signal converters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1182 (8923-1182)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a reliable physical layer for L-Series digital communication.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8293-1182\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB Service Communication Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB Type-A to Controller Proprietary Termination\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward L-Series Engine Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-purity copper core for low resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade PVC (Oil and Dust Resistant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kg (Total shipping weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e260 × 126 × 102 mm (Packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiagnostics, Configuration, Tuning, Firmware Updates\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52519572471992,"sku":"8923-1182","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/142..jpg?v=1770004580"},{"product_id":"woodward-8923-1262-module-usb-communication-interface","title":"Woodward 8923-1262 Module | USB Communication Interface","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 8923-1262 USB Service and Configuration Interface Cable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1262 (Model: 8923-1262)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a professional-grade USB service interface designed specifically for the Woodward ecosystem of engine and generator controllers. This specialized communication tool acts as the critical bridge between modern PC-based diagnostic software and the controller's internal logic. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1262 (Part Number: 8923-1262)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to replace legacy RS-232 serial cables, providing a high-speed, plug-and-play solution for technicians who need to perform field commissioning, parameter optimization, and firmware upgrades.\u003c\/p\u003e\n\u003cp\u003eUnlike standard consumer-grade cables, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1262 (Service Tool: 8923-1262)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates galvanic isolation and heavy-duty industrial shielding. This protection is vital in power generation and marine engine rooms, where high-frequency electromagnetic interference (EMI) can corrupt data or damage laptop hardware during a live connection. The cable facilitates \"Authoritative\" access to Woodward’s EasyGen, L-Series, and various digital governor platforms, ensuring that configuration data is transmitted with 100% integrity under the most demanding industrial conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8923-1262 (8923-1262)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the hardware foundation for deterministic communication with Woodward ECUs.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8923-1262\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB Service\/Configuration Interface Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB Standard Type-A (PC side) to Controller Proprietary Termination\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward EasyGen, L-Series, and compatible ECUs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed digital communication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic isolation for transient and EMI protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-purity copper core for signal stability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-temperature resistant PVC, industrial grade\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200g (Cable only) \/ Shipping weight0.5kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 1.5m to 3.0m versions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52519576961208,"sku":"8923-1262","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/142_915f691e-cc1b-472a-a516-c3a6d4a9ec68.jpg?v=1770011999"},{"product_id":"yokogawa-acm11-sealed-s2-rs-485-communication-module","title":"Yokogawa ACM11 | Sealed S2 RS-485 Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa ACM11 RS-232C Subsystem Communication Module S2\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACM11 (Model: ACM11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance subsystem communication module designed for the Yokogawa CENTUM CS 3000 and CENTUM VP Distributed Control System (DCS) environments. This module functions as a critical bridge between the Field Control Station (FCS) and external subsystems such as PLCs, sequencers, and specialized analyzers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACM11 (Part Number: ACM11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates seamless data exchange by mapping subsystem data into the PI\/O image area, which is then accessed by the FCS via the RIO bus.\u003c\/p\u003e\n\u003cp\u003eEngineered for industrial reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACM11 (Module: ACM11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures galvanic isolation and advanced error detection to ensure data integrity in electronically noisy plant environments. By offloading serial communication tasks—including protocol handling for RS-232C, RS-422, and RS-485—it preserves the main processor's CPU efficiency. This module is an essential component for integrating third-party equipment into a unified Yokogawa control architecture, providing the deterministic connectivity required for petrochemical, power, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACM11 (ACM11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to support diverse serial communication standards within a ruggedized DCS rack.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eACM11\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2 (Sealed \/ NSS compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSubsystem Communication Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Bus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRIO Bus (Remote I\/O Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232C, RS-422, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC \/ 24 VDC (Internal via rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation (Signal and Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed asynchronous\/synchronous support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mm × 100 mm × 42 mm (Module base)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard I\/O Nest \/ Rack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52519798636728,"sku":"ACM11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51..jpg?v=1770013623"},{"product_id":"redundant-network-interface-module-tc-ccn013-honeywell","title":"Redundant Network Interface Module TC-CCN013 Honeywell","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCN013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: TC-CCN013) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized network interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. Serving as a critical gateway, it enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween controllers and distributed I\/O devices over a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlNet network\u003c\/strong\u003e. By supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant configurations\u003c\/strong\u003e, the TC-CCN013 ensures communication remains active even in the event of a media or port failure, preserving the integrity of industrial control processes.\u003c\/p\u003e\n\u003cp\u003eEquipped with advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic capabilities\u003c\/strong\u003e, this module allows engineers to monitor network health in real-time. It is engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic, repeatable timing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired for high-speed discrete and process applications, guaranteeing that mission-critical data is delivered\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithout jitter or delay\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-CCN013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant ControlNet Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw (5.1 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e970 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw (24 VDC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlNet (Standard and Enhanced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedia Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-media interface with redundancy logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-facing LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.8 × 9.1 × 4.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eImplementing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant network paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor critical safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix processors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith remote Series A or Series C I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability manufacturing lines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere communication downtime is costly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the TC-CCN013 handle network failures?\u003c\/strong\u003e\u003cbr\u003eA: The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant cabling and configuration\u003c\/strong\u003e, allowing automatic switching of communication paths if the primary line fails, without interrupting control logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with both Standard and Enhanced ControlNet?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The TC-CCN013 operates seamlessly across both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard and Enhanced ControlNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetwork specifications for maximum flexibility.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520698118328,"sku":"TC-CCN013","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-CCN013_8eb7e0be-f727-4f02-ac1d-bb088578ef38.jpg?v=1770017079"},{"product_id":"tc-ccr012-honeywell-redundant-network-interface-module","title":"TC-CCR012 Honeywell Redundant Network Interface Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCR012\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: TC-CCR012) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability communication bridge\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell C300 Controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironment. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRedundant ControlNet Interface Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides dual-port connectivity, enabling the system to maintain stable communications even in the event of a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecable break or port failure\u003c\/strong\u003e. By leveraging two independent ControlNet ports, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic failover\u003c\/strong\u003e, ensuring uninterrupted operation for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial processes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for resilience, the TC-CCR012 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair media\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is built to withstand extreme environmental conditions. Its compact form factor allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density installation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein control cabinets, while integrated diagnostics provide real-time feedback on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enetwork health and port status\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-CCR012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Ports (Port A and Port B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × DB9 Male Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedia Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Thermal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 × 160 × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant network backbone for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 Distributed Control Systems (DCS)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-reliability communication in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoffshore oil platforms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand remote pumping stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImplementing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efail-safe data paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein hazardous Area Zone 2 environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TC-CCR012 support automatic path switching?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Built-in redundancy logic triggers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic failover\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the secondary port if the primary detects a signal loss, ensuring uninterrupted data flow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of cabling is required for the DB9 ports?\u003c\/strong\u003e\u003cbr\u003eA: The module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-quality shielded twisted-pair ControlNet cabling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support 5 Mbps performance and maintain high RFI\/EMI immunity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520835711160,"sku":"TC-CCR012","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-CCR012_892bea5c-ecb7-4231-9af4-f68c9cdbf040.jpg?v=1770017078"},{"product_id":"redundant-network-interface-module-tc-ccr014-honeywell","title":"Redundant Network Interface Module TC-CCR014 Honeywell","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCR014\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: TC-CCR014) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance Redundant Net Interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Designed as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary communication bridge\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor C300 controllers, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-media network paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure continuous, high-availability communication across\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlNet infrastructures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for facilities requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic and repeatable network performance\u003c\/strong\u003e, the TC-CCR014 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic failover\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween network cables, safeguarding mission-critical process data. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact, lightweight design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows easy installation in standard Series C mounting structures while maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial-grade durability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor harsh manufacturing and process environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-CCR014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant ControlNet Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlNet (Series C Architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Role\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Network Card for C300\/Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical Series C Plug-in Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel network media failover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED indicators for network health and module status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlugs into a compatible Series C IOTA (Input Output Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardized ControlNet speeds for real-time process control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEstablishing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant ControlNet backbone\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Experion PKS clusters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controllers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith distributed Series C I\/O racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-reliability networking in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical infrastructure automation requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero single-point-of-failure networking\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the TC-CCR014 differ from standard network cards?\u003c\/strong\u003e\u003cbr\u003eA: The TC-CCR014 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epurpose-built for redundancy\u003c\/strong\u003e, supporting dual-cable connections with onboard logic to automatically switch paths if one line fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be hot-swapped?\u003c\/strong\u003e\u003cbr\u003eA: Yes. When used in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant pair\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor properly configured Series C environment, the TC-CCR014 can typically be replaced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithout shutting down the control node\u003c\/strong\u003e, minimizing process downtime.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520850817208,"sku":"TC-CCR014","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-CCR0142_4bfe0904-0a5f-4f0c-ad26-5210b4f2d780.jpg?v=1770017079"},{"product_id":"tc-pcic01k-honeywell-controlnet-interface-module","title":"TC-PCIC01K Honeywell ControlNet Interface Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-PCIC01K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: TC-PCIC01K) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eruggedized PCI-bus interface card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to bridge standard industrial PCs with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlNet network\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“K” variant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epremium conformal coating\u003c\/strong\u003e, providing enhanced protection against\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emoisture, dust, and corrosive vapors\u003c\/strong\u003e. It is engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eworkstations and servers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein harsh industrial environments where long-term reliability is critical.\u003c\/p\u003e\n\u003cp\u003eThis module enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed, deterministic data exchange at 5 Mbps\u003c\/strong\u003e, allowing PC-based\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMIs, engineering stations, or data historians\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto communicate directly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS systems\u003c\/strong\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swap support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLED diagnostics\u003c\/strong\u003e, the TC-PCIC01K ensures flexible, maintainable network integration without interrupting critical system power.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-PCIC01K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard PCI Bus (Motherboard Slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Transmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coating (Moisture \u0026amp; Corrosion Resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB9 Male Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI Bus Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection (Coated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 equivalent for onboard electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, cUL, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.7 × 6.6 × 3.3 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Engineering Stations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto a ControlNet backbone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePC-based data acquisition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein high-humidity chemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI workstations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein dusty environments such as cement or mining facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProviding a stable communication link for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elegacy industrial PCs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the ‘K’ suffix in the model number?\u003c\/strong\u003e\u003cbr\u003eA: The “K” indicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating\u003c\/strong\u003e, which protects the circuitry from harsh environmental factors like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esalt air, humidity, and fine conductive dust\u003c\/strong\u003e, preventing potential short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which operating systems are compatible with this card?\u003c\/strong\u003e\u003cbr\u003eA: The TC-PCIC01K is primarily supported on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWindows-based platforms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing Honeywell’s dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edriver suite and communication tools\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., RSLinx or Experion software).\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520859861176,"sku":"TC-PCIC01K","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-PCIC01K_adee360f-737d-44b2-b5e5-839bbd26d7ea.jpg?v=1770017081"},{"product_id":"honeywell-ethernet-communication-module-tc-cen021","title":"Honeywell Ethernet Communication Module TC-CEN021","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CEN021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: TC-CEN021) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance Ethernet communication interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS and Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol architectures. This module serves as a bridge between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtroller backplane\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand local area networks, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erapid data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eamong controllers, workstations, and other industrial devices. It provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estable, deterministic connection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eessential for real-time monitoring and control in complex automation systems.\u003c\/p\u003e\n\u003cp\u003eDesigned for industrial longevity, the TC-CEN021 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10\/100 Mbps Ethernet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand utilizes a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRJ45 connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor seamless integration with industrial switches. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewide operating temperature range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emake it suitable for harsh or non-climate-controlled environments, ensuring reliable network uptime for mission-critical process data.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-CEN021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Ethernet (TCP\/IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto-sensing 10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × RJ45 Ethernet Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–95% Relative Humidity (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121 × 102 × 76 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional conformal coating for harsh or high-moisture environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries C controllers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto supervisory Ethernet networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI stations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith real-time process data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEstablishing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed peer-to-peer links\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethird-party Ethernet-enabled devices\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto Experion PKS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the TC-CEN021 compatible with Gigabit Ethernet switches?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module can connect to Gigabit switches via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eauto-negotiation\u003c\/strong\u003e, but the maximum data rate will be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimited to 100 Mbps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a specific IOTA base?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Like all Series C modules, the TC-CEN021 must be mounted on a compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInput Output Termination Assembly (IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto receive power and provide the physical RJ45 connection.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520877654200,"sku":"TC-CEN021","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-CEN021_57b58f28-a57d-4cef-a1b7-de11f09b6eb2.jpg?v=1770017080"},{"product_id":"tk-fteb01-51309512-175-51403483-100-honeywell-fte-ethernet-module","title":"TK-FTEB01 51309512-175 51403483-100 Honeywell FTE Ethernet Module","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTK-FTEB01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Numbers: 51309512-175 \/ 51403483-100) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized Fault Tolerant Ethernet (FTE) bridge module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion LS and PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. It serves as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical communication link\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the controller chassis and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTE network\u003c\/strong\u003e, providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant, high-speed data paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor I\/O modules and controllers. Unlike standard Ethernet cards, this module is engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial resilience\u003c\/strong\u003e, ensuring uninterrupted communication even in the event of a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle cable or switch failure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density industrial environments\u003c\/strong\u003e, the TK-FTEB01 facilitates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enetwork diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the Experion software. Its compact form factor allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeasy integration into Series-A chassis\u003c\/strong\u003e, supporting the stringent reliability requirements of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein chemical, pharmaceutical, and energy industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTK-FTEB01 (51309512-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51403483-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault Tolerant Ethernet (FTE) Bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast Ethernet (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExperion LS and PKS Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant FTE network connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Role\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBridges I\/O link data to the FTE supervisory network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92 × 94 × 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.226 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEstablishing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant Ethernet backbone\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Experion LS controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote I\/O chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith central processing units over FTE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability networking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor critical process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacing or upgrading\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein existing Honeywell DCS racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of “Fault Tolerant” in this module?\u003c\/strong\u003e\u003cbr\u003eA: The TK-FTEB01 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple communication paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing Honeywell’s FTE technology. If one network cable fails, the module\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einstantly reroutes data\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough the alternate path without losing control or visibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support standard RJ45 connectors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard industrial Ethernet cabling and RJ45 connectors\u003c\/strong\u003e, but full redundancy requires an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTE-compliant network architecture\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520934572216,"sku":"TK-FTEB01 51309512-175 51403483-100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TK-FTEB01_51309512-175_51403483-100_7260fe41-0ab0-49f0-a848-e32c5e59cc07.jpg?v=1770019398"},{"product_id":"redundant-controlnet-module-tc-ccr013-honeywell","title":"Redundant ControlNet Module TC-CCR013 Honeywell","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCR013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-CCR013\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant ControlNet communication interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Designed to operate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controllers\u003c\/strong\u003e, this module enables deterministic, real-time data exchange across ControlNet networks used in mission-critical process control systems.\u003c\/p\u003e\n\u003cp\u003eA defining feature of the TC-CCR013 is its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-media architecture\u003c\/strong\u003e, combining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecopper (twisted-pair)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiber-optic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity within a single module. This hybrid design allows engineers to balance short-range cabinet wiring with long-distance or high-noise plant connections, ensuring reliable communication in electrically harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eBuilt for high availability, the TC-CCR013 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant network operation with automatic failover\u003c\/strong\u003e, maintaining continuous data flow if one communication path becomes unavailable. Integrated diagnostics and industrial certifications make it well-suited for continuous-duty applications in offshore platforms, refineries, chemical plants, and power generation facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-CCR013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-port with automatic failover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Mbps (ControlNet standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedia Port A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted pair, DB9 male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedia Port B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber optic (SC or ST, variant dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−40°C to +70°C (−40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 × 160 × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controllers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto remote ControlNet I\/O racks over fiber-optic links\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImplementing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant ControlNet paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein high-EMI environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeploying ControlNet networks in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass I, Division 2 hazardous locations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModernizing or extending legacy ControlNet infrastructures within Experion PKS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the TC-CCR013 use two different media types?\u003c\/strong\u003e\u003cbr\u003eThe dual-media design provides flexibility. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDB9 copper port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for short, local cabinet connections, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiber-optic port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports long distances and offers immunity to electromagnetic interference, enabling reliable communication across diverse plant environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TC-CCR013 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. When installed as part of a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant Series C configuration\u003c\/strong\u003e, the TC-CCR013 can be replaced online without interrupting controller operation or ControlNet communications, provided the secondary path remains active.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52520979464376,"sku":"TC-CCR013","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TC-CCR0132_55b1cfd4-82a5-4921-826e-0d1197d826ff.jpg?v=1770017080"},{"product_id":"abb-ci547-3bnp004429r1-communication-board-with-slave-processor","title":"ABB CI547 3BNP004429R1 Communication Board with Slave Processor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB CI547 \u003cstrong\u003e3BNP004429R1\u003c\/strong\u003e is a communication module designed to optimize system performance by offloading tasks from the central processor PM150. Equipped with a dedicated slave processor, this board enhances communication efficiency within ABB control systems. Compact in size and lightweight, the CI547 is engineered for reliable integration and compliance with EU environmental directives.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType Designation:\u003c\/strong\u003e CI547\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number \/ Model:\u003c\/strong\u003e \u003cstrong\u003e3BNP004429R1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMedium Description:\u003c\/strong\u003e Communication Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExchange Number:\u003c\/strong\u003e EXC3BNP004429R1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth\/Length: 125 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 30 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 257 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.165 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes slave processor to reduce workload from PM150 central processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS: EU Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWEEE Category: 5 (Small Equipment, \u0026lt;50 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCIP Reference: 54d0bb6e-68f5-4083-9b71-f6072c3f8e33 (Sweden)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Content:\u003c\/strong\u003e None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication management in ABB control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWorkload distribution between central and slave processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring reliable communication modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the main function of the CI547 board?\u003c\/strong\u003e  A: It includes a slave processor to reduce the workload from the PM150 central processor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the dimensions of the CI547 module?\u003c\/strong\u003e  A: 125 mm × 257 mm × 30 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the CI547 RoHS compliant?\u003c\/strong\u003e  A: Yes, it complies with EU Directive 2011\/65\/EU.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCI547 (3BNP004429R1):\u003c\/strong\u003e Communication board with slave processor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCI522:\u003c\/strong\u003e Standard communication board without slave processor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCI570:\u003c\/strong\u003e Advanced communication module with extended processing capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52520980119736,"sku":"CI547 3BNP004429R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CI5473BNP004429R11.jpg?v=1770021214"},{"product_id":"ci541v1-3bse014666r1-abb-profibus-interface-submodule","title":"CI541V1 3BSE014666R1 | ABB Profibus Interface Submodule","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB CI541V1 \u003cstrong\u003e3BSE014666R1\u003c\/strong\u003e is a Profibus interface submodule designed for ABB control systems. Compact and lightweight, this communication module provides reliable connectivity for Profibus networks. It is engineered to meet ABB’s standards for industrial automation, offering stable integration with existing system architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType Designation:\u003c\/strong\u003e CI541V1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number \/ Model:\u003c\/strong\u003e \u003cstrong\u003e3BSE014666R1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Interface Submodule\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Standard:\u003c\/strong\u003e Profibus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth\/Length: 255 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 20 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 125 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.17 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoHS Status: Not compliant with EU Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWEEE Category: 5 (Small Equipment, no external dimension greater than 50 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBattery Content:\u003c\/strong\u003e None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of Profibus communication into ABB control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring modular communication submodules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse in environments where compact design and lightweight modules are preferred\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication protocol does the CI541V1 support?\u003c\/strong\u003e  A: Profibus.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What are the dimensions of the CI541V1 module?\u003c\/strong\u003e  A: 255 mm × 125 mm × 20 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the CI541V1 RoHS compliant?\u003c\/strong\u003e  A: No, it is not compliant with EU Directive 2011\/65\/EU.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCI541V1 (3BSE014666R1):\u003c\/strong\u003e Profibus interface submodule.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCI542:\u003c\/strong\u003e Interface module supporting different communication protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCI547:\u003c\/strong\u003e Communication board with slave processor for workload distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52520986640568,"sku":"CI541V1 3BSE014666R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CI541V13BSE014666R1__1.jpg?v=1770021485"},{"product_id":"abb-innis01-network-interface-slave-module-infi-90","title":"ABB INNIS01 Network Interface Slave Module | INFI 90","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eINNIS01\u003c\/strong\u003e Network Interface Slave Module is a communication interface unit designed for ABB’s INFI 90 OPEN control systems. It provides reliable connectivity between controllers and distributed nodes, supporting high-speed data transfer rates and flexible integration with multiple interface types. With robust memory capacity and efficient power requirements, the \u003cstrong\u003eINNIS01\u003c\/strong\u003e ensures stable operation in complex industrial networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eINNIS01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Network Interface Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRAM: 208 kB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eROM: 64 kB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e+5 VDC: 900 mA (4.50 W nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e+15 VDC: 5 mA (0.08 W nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e–15 VDC: 200 mA (3.00 W nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Capability:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Nodes in System: 62,500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNodes per Loop: 250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Interfaces:\u003c\/strong\u003e PCU, MCS, OIS, ICI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Rates:\u003c\/strong\u003e 10 Mbaud or 2 Mbaud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Occupies one slot in INFI 90 OPEN module mounting unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.93 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-speed communication with selectable baud rates\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge system capacity supporting up to 62,500 nodes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible interface compatibility for diverse system configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for easy integration into INFI 90 OPEN racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStable performance with efficient power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems requiring reliable communication modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation networks with large node capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB INFI 90 OPEN system expansions and upgrades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication speeds does the INNIS01 support?\u003c\/strong\u003e  A: 10 Mbaud and 2 Mbaud.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many nodes can be supported in a system?\u003c\/strong\u003e  A: Up to 62,500 nodes, with 250 nodes per loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which ABB interfaces are compatible?\u003c\/strong\u003e  A: PCU, MCS, OIS, and ICI interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is the module installed?\u003c\/strong\u003e  A: It occupies one slot in a standard INFI 90 OPEN mounting unit.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521294233784,"sku":"INNIS01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/INNIS01.jpg?v=1770025830"},{"product_id":"abb-ntcl01-infi-net-communication-link-termination-unit","title":"ABB NTCL01 INFI-Net Communication Link Termination Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB \u003cstrong\u003eNTCL01\u003c\/strong\u003e INFI-Net Communication Link Termination Unit is engineered to provide reliable signal termination and communication support within ABB’s INFI-Net network. Designed for use with NIS and NKLS modules, the \u003cstrong\u003eNTCL01\u003c\/strong\u003e ensures stable data transfer and system integrity in distributed control environments. Its compact dimensions allow easy installation in control cabinets while maintaining robust performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Catalog Number:\u003c\/strong\u003e \u003cstrong\u003eNTCL01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e INFI-Net Communication Link Termination Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Modules:\u003c\/strong\u003e NIS, NKLS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Facilitates communication over INFI-Net network\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth\/Length: 96.52 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 236.22 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 220.98 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides secure termination for INFI-Net communication links\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for compatibility with NIS and NKLS modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact form factor for efficient cabinet integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures reliable communication across distributed control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB INFI-Net distributed control system installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation networks requiring stable communication links\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControl cabinets with NIS and NKLS module integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which modules are supported by the NTCL01?\u003c\/strong\u003e  A: It is designed for use with NIS and NKLS modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the NTCL01?\u003c\/strong\u003e  A: It provides termination and facilitates communication over the INFI-Net network.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the NTCL01 be installed in standard control cabinets?\u003c\/strong\u003e  A: Yes, its compact dimensions allow easy integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTCL01:\u003c\/strong\u003e Standard termination unit for NIS\/NKLS modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTCL02:\u003c\/strong\u003e Enhanced termination with extended communication diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNTCL03:\u003c\/strong\u003e Multi-link termination for larger system configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52521309438136,"sku":"NTCL01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NTCL01.jpg?v=1770026084"},{"product_id":"allen-bradley-1747-sdn-slc-500-devicenet-scanner-module","title":"Allen-Bradley 1747-SDN SLC 500 DeviceNet Scanner Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-SDN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet Scanner Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley SLC 500 series\u003c\/strong\u003e. It serves as the primary interface between an SLC 500 processor (such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 5\/03, 5\/04, or 5\/05\u003c\/strong\u003e) and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet network\u003c\/strong\u003e, enabling communication with up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e63 DeviceNet-compatible devices\u003c\/strong\u003e, including motor starters, drives, photo-eyes, and I\/O adapters.\u003c\/p\u003e\n\u003cp\u003eThe module supports advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChange-of-State (COS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCyclic I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodes to optimize network traffic by sending updates only when necessary. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet Pass-Through\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeature allows direct configuration of field devices via software like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRSNetWorx for DeviceNet\u003c\/strong\u003e, eliminating the need for external programming adapters.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1747-SDN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Scanner Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviceNet Node Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 63 slave devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 k, 250 k, 500 k baud (auto-detect or manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Operating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolled, Strobe, Change-of-State (COS), Cyclic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviceNet Power Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mA at 24V DC (from network)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects SLC 500 controllers to remote Point I\/O or ArmorPoint I\/O blocks via DeviceNet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfaces with PowerFlex drives or SMC Flex starters to monitor current, speed, and fault status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Bridge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUses Pass-Through to configure DeviceNet networks without additional PC interface hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Sensing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eImplements Change-of-State messaging for rapid detection in packaging or sorting lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan multiple 1747-SDN modules be installed in a single SLC 500 rack?\u003c\/strong\u003e\u003cbr\u003eYes, multiple scanners can be installed as long as the total backplane current does not exceed the SLC power supply capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require a separate power supply for the DeviceNet network?\u003c\/strong\u003e\u003cbr\u003eYes, the DeviceNet network must have a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated 24V DC power source\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typically Class 2) to energize both the scanner and connected field devices.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52521318777016,"sku":"1747-SDN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1747-SDN2.jpg?v=1770026169"},{"product_id":"allen-bradley-1734-aent-point-i-o-ethernet-ip-communication-adapter-module","title":"Allen-Bradley 1734-AENT POINT I\/O EtherNet\/IP Communication Adapter Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-AENT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance EtherNet\/IP communication adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O platform\u003c\/strong\u003e, providing a reliable interface between distributed I\/O modules and a centralized EtherNet\/IP controller. Acting as the gateway for a POINT I\/O assembly, it enables high-speed exchange of real-time I\/O data and diagnostic information over standard Ethernet networks.\u003c\/p\u003e\n\u003cp\u003eDesigned for flexible, distributed control architectures, the 1734-AENT helps reduce wiring costs and improve system scalability. A single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10\/100 Mbps RJ45 Ethernet port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith auto-negotiation supports common\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estar and tree topologies\u003c\/strong\u003e, while integrated status LEDs allow quick, localized diagnostics of module, network, and POINTBus operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1734-AENT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × RJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps, full or half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStar, Tree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 6 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePOINTBus Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 A @ 5 V DC (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT5 shielded or unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Red\/Green LEDs (Module, Network, POINTBus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.23 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eCore Application Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Architectures\u003c\/strong\u003e\u003cbr\u003eLocating POINT I\/O racks close to machines while maintaining high-speed connectivity to ControlLogix or CompactLogix controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Process Monitoring\u003c\/strong\u003e\u003cbr\u003eTransferring digital and analog I\/O data together with module diagnostics for enhanced visibility and predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Expansion\u003c\/strong\u003e\u003cbr\u003eAdding new I\/O nodes to an existing EtherNet\/IP network without major control system redesign.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many POINT I\/O modules can the 1734-AENT support?\u003c\/strong\u003e\u003cbr\u003eA: Up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e63 POINT I\/O modules\u003c\/strong\u003e, provided the total backplane current consumption does not exceed the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0 A POINTBus limit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1734-AENT support Device Level Ring (DLR)?\u003c\/strong\u003e\u003cbr\u003eA: No. The standard 1734-AENT has a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle Ethernet port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand supports star or tree topologies only. For DLR, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENTR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(dual-port) adapter is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IP address be set manually?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The IP address can be configured using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eon-board thumbwheel switches\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBOOTP\/DHCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware tools.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52524455035064,"sku":"1734-AENT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-AENT1.jpg?v=1770084426"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/communication-networking.oembed?page=13","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}