{"title":"GE Genius I\/O","description":"\u003cp\u003eAs one of the first successful distributed I\/O systems, GE Genius I\/O is still integral to many complex plant architectures. This category includes the specialized Genius blocks known for their built-in diagnostics and rugged reliability in harsh environments. Whether used with Series 90-70 or PACSystems controllers, these blocks provide a distributed interface for digital and analog signals. Our inventory supports maintenance teams looking for specific Genius I\/O part numbers to sustain legacy network structures where reliability and diagnostic feedback are prioritized over system-wide upgrades.\u003c\/p\u003e","products":[{"product_id":"ge-fanuc-ic660bbd021-genius-i-o-block-16-point-sink","title":"GE Fanuc IC660BBD021 | Genius I\/O Block | 16-Point Sink","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003eHigh-Density Distributed I\/O Control\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660BBD021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Genius I\/O Block engineered for distributed control in rugged industrial environments. This 16-circuit module is designed for 24\/48 VDC sinking I\/O operations, meaning current flows from the load into the block. It serves as an intelligent node on the Genius bus, providing a bridge between the central controller and field devices such as three-wire sensors, solenoids, and relays. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660BBD021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis composed of two primary components: the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660EBD021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eelectronics assembly and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660TSD021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal base, which together provide a robust, modular solution for discrete automation.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Protection and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eOne of the defining technical strengths of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660BBD021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its comprehensive internal suite of protection and diagnostic tools. Each of the 16 circuits features independent electronic short-circuit protection and thermal shutdown capabilities, preventing localized field faults from damaging the entire block. The module provides real-time feedback to the bus controller regarding circuit health, including overtemperature alarms and communication status. With an isolation rating of 1500V block-to-block, it ensures that sensitive logic electronics remain shielded from high-voltage transients common in power generation and heavy manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table summarizes the electrical and environmental parameters for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660BBD021\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC660BBD021\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Base\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC660TSD021\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSink I\/O (16 Circuits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24\/48 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 56 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Current per Circuit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Block Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 A Total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V (Block to Block)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Processing Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.7 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A (up to 10 ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channel LEDs + 1 Unit Health LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 mm x 127 mm x 102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52528831332536,"sku":"IC660BBD021","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/190.1.jpg?v=1770191431"},{"product_id":"ge-fanuc-ic660brd025-genius-i-o-block","title":"GE Fanuc IC660BRD025 Genius I\/O Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC660BRD025\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Genius I\/O block designed for distributed control within GE Fanuc PLC architectures. This 16-point Relay Output block provides the physical interface between the Genius network bus and field devices such as motor starters, solenoids, and indicators. By utilizing a decentralized design, the IC660BRD025 eliminates long runs of expensive field wiring and simplifies cabinet layouts. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal unit ensures maximum contact life and circuit integrity, providing the robust switching capabilities required for heavy-duty industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BRD025 utilizes advanced diagnostics and rugged relay components to manage discrete output signals:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC660BRD025\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc (General Electric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGenius I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolated Relay Outputs (Normally Open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Points (2 groups of 8)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e115 VAC \/ 125 VDC or 230 VAC \/ 24 VDC (Application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Amps per point \/ 8 Amps per group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGenius Bus (Serial)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual point monitoring and internal hardware checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500V input-to-output galvanic isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 60 °C (32 to 140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe GE IC660BRD025 delivers technical solutions for demanding electrical switching and networking challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BRD025 monitors internal circuit health and communication status in real-time. It detects \"failed-to-open\" or \"failed-to-close\" relay conditions, allowing maintenance teams to identify hardware issues before they cause process downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Distributed Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis Genius I\/O block mounts directly near the field equipment. By transmitting data over a single twisted-pair serial cable instead of individual wires for every relay, it significantly reduces installation costs and commissioning time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Mechanical Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineers the relays within the IC660BRD025 to handle high-inrush currents associated with inductive loads. This prevents contact welding and ensures thousands of reliable cycles even in harsh environments with high electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe block's two-piece design allows for the replacement of the electronic assembly without disturbing the field wiring. This \"Hot-Swap\" capability minimizes Mean Time To Repair (MTTR) during critical maintenance windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC660BRD025 require a separate Hand-Held Monitor (HHM) for configuration?\u003c\/strong\u003eWhile you can configure the block via the Genius network software, using a GE Hand-Held Monitor (IC660HHM501) allows for local troubleshooting and forced-point testing directly at the cabinet without a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the isolated relay design?\u003c\/strong\u003eThe isolation ensures that electrical surges or ground loops in the field wiring do not propagate back to the Genius network or the central PLC, protecting your entire control system from damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC660BRD025 handle both AC and DC loads simultaneously?\u003c\/strong\u003eYes, provided the loads remain within the specified voltage and current ratings for the individual isolated groups. Always consult the wiring schematic to ensure proper grouping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy should I avoid refurbished or \"New Other\" IC660BRD025 units?\u003c\/strong\u003eRelay contacts suffer from mechanical wear and electrical pitting over time. Refurbished units often contain relays near the end of their service life. Only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal units guarantee the full rated switching capacity and diagnostic accuracy for mission-critical operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e25\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53441315307704,"sku":"IC660BRD025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BRD025_1_1.jpg?v=1778121953"},{"product_id":"ic660brd020-ge-fanuc-genius-i-o-sink-source-output-block","title":"IC660BRD020 GE Fanuc Genius I\/O Sink\/Source Output Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC660BRD020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-density discrete output module within the Genius I\/O distributed network. This 16-point DC Sink\/Source Output block provides the essential interface between a central PLC and field-side DC actuators, such as solenoids, pilot lights, and small DC motor starters. Supporting both 24 VDC and 48 VDC applications, the IC660BRD020 features flexible wiring configurations to accommodate either sinking or sourcing logic. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal unit ensures the timing precision and diagnostic depth required for high-speed automated assembly lines and process control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BRD020 utilizes solid-state switching technology and advanced internal monitoring to manage DC field loads:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC660BRD020\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc (General Electric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGenius I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-State DC Sink\/Source\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC or 48 VDC (Nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18 to 56 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Amps maximum per point \/ 15 Amps maximum per block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Amps for 10ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGenius Bus (Serial twisted-pair)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500V galvanic isolation between field logic and bus electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 60 °C (32 to 140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe GE IC660BRD020 delivers robust technical solutions for distributed DC power management:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Sink\/Source Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can configure the IC660BRD020 for either sinking or sourcing operation by adjusting the field wiring and common connections. This versatility allows a single spare part to support multiple machine types across a facility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Electronic Short-Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module incorporates high-speed electronic fuses that monitor each output point. If a short circuit occurs in the field wiring, the IC660BRD020 shuts down the specific point instantly and transmits a fault message to the PLC, protecting the internal circuitry and the power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNo-Load and Overload Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module identifies \"Open Wire\" conditions (no-load) and overcurrent events even when the output is off. This proactive diagnostic capability prevents unexpected failures during startup and simplifies routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart \"Failed-Switch\" Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BRD020 continuously verifies the state of its internal power transistors. It detects if a switch has failed in the \"ON\" or \"OFF\" position, allowing the safety system to initiate a controlled shutdown if critical outputs lose control integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the IC660BRD020 with a 24VDC and 48VDC load on the same block?\u003c\/strong\u003eWhile the module supports both voltages, all 16 points typically share the same field power source per block. Mixing voltages requires careful isolation and is generally not recommended within a single IC660BRD020 unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I address this block on the Genius Network?\u003c\/strong\u003eYou set the Block Address (0-31) using a GE Hand-Held Monitor (IC660HHM501) or through the Genius configuration software. The address remains stored in the block's non-volatile memory even after power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external fuses?\u003c\/strong\u003eThe IC660BRD020 features internal electronic protection; however, we recommend secondary external branch fusing to meet specific local electrical codes and to provide physical isolation during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is \"Brand New\" original stock preferred over refurbished units?\u003c\/strong\u003eSolid-state DC outputs are sensitive to thermal cycling and voltage transients. Refurbished units often have degraded power transistors that may fail under full load. Only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits guarantee the original OEM thermal ratings and high-speed diagnostic accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53441352630456,"sku":"IC660BRD020","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BRD020_2_1.jpg?v=1778122063"},{"product_id":"genius-i-o-discrete-block-ic660bbd020-ge-fanuc","title":"Genius I\/O Discrete Block IC660BBD020 GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBD020 (IC660BBD020) is a versatile 16-circuit discrete I\/O block belonging to the GE Fanuc Genius I\/O family. This module operates as a distributed I\/O station, interfacing directly with the Genius network to provide decentralized control for 24 VDC or 48 VDC applications. This block functions autonomously by managing its own diagnostics and reporting circuit-level faults back to the controller. Ideal for automotive assembly lines, material handling, and chemical processing, the IC660BBD020 eliminates long cable runs by placing I\/O points closer to field devices. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein original factory packaging to ensure maximum operational life and system integrity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBD020 utilizes advanced electronic power switching to manage 16 independent circuits that users can configure as inputs, outputs, or a combination of both.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBD020\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Individually Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC or 48 VDC (Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 56 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input\/Output (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A per circuit (Max 8 A per block)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort Circuit, Overload, No-Load, Failed Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit-Level Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides ultimate flexibility by allowing engineers to define each of the 16 points as either an input or an output. This reduces the inventory of spare parts required, as one block type handles multiple field configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BBD020 detects and reports specific faults such as \"No Load\" or \"Short Circuit\" for each individual point. This allows maintenance teams to pinpoint exact field wiring issues without opening the control cabinet, drastically reducing Mean Time To Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGenius Network Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the global data capabilities of the Genius network, this block can share data with other blocks or controllers without requiring a dedicated CPU scan, enhancing the real-time response of the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe block features a robust, enclosed design capable of withstanding the electrical noise and vibration typical of heavy industrial plant floors. The terminal assembly is separable, allowing for module replacement without disturbing field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this block with 48 VDC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC660BBD020 is designed to operate within a wide DC voltage range (18 to 56 VDC), making it fully compatible with both 24 VDC and 48 VDC industrial power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the block require a separate power supply for the Genius bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block draws its operating power from the same DC power source connected to its I\/O terminals. It communicates with the controller via a shielded twisted-pair Genius bus cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a circuit exceeds its current rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block incorporates electronic short-circuit and overload protection. If it detects an over-current condition, the block automatically shuts down the affected circuit and sends a diagnostic message to the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this block compatible with modern PACSystems RX3i controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While Genius I\/O is a legacy series, it integrates seamlessly with PACSystems RX3i using a Genius Bus Controller (GBC) module, providing a reliable migration path for older systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447250378936,"sku":"IC660BBD020","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBD020_3.jpg?v=1778231850"},{"product_id":"ic660bba026-ge-fanuc-enius-i-o-rtd-input-block","title":"IC660BBA026 GE Fanuc enius I\/O RTD Input Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA026 (IC660BBA026) is a high-precision, 6-channel Resistance Temperature Detector (RTD) input block within the GE Fanuc Genius I\/O family. This intelligent distributed I\/O module interfaces directly with standard RTD sensors to provide accurate temperature data acquisition over the Genius bus. Engineered for thermal monitoring in plastic extrusion, chemical reactors, and large motor bearings, the IC660BBA026 converts low-level resistance signals into digital temperature values. By processing signals at the source, this block eliminates the need for expensive long-run compensated wiring back to a central controller. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-calibrated accuracy and long-term reliability for your process control system.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA026 features advanced signal conditioning and supports multiple RTD types with high resolution.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBA026\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported RTDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum (100, 200, 500 ohm), Nickel (120 ohm), Copper (10 ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 deg C or 0.1 deg F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500V between Genius bus and inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC, 230 VAC, or 24\/48 VDC (Version dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis block accommodates a variety of Platinum, Nickel, and Copper RTDs. Engineers configure the sensor type and temperature scale (Celsius or Fahrenheit) via software, providing a flexible solution for diverse global installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Lead Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BBA026 supports 3-wire RTD configurations, allowing the module to automatically compensate for lead wire resistance. This ensures measurement accuracy even when the block is mounted at a significant distance from the actual sensing point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module monitors each channel for \"Open Sensor,\" \"Short Circuit,\" and \"High\/Low Alarm\" limits. It transmits these diagnostics over the Genius network, allowing operators to identify failed probes before they trigger a process shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the Genius bus, the IC660BBA026 operates as a standalone intelligence unit. It continues to monitor and provide local diagnostics even if communication with the main CPU is momentarily interrupted, maintaining a safe \"Hold Last State\" or \"Go to Zero\" output profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different types of RTDs on the same block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The block typically applies the selected configuration to all six channels. All sensors connected to a single IC660BBA026 must be of the same type (e.g., all Pt 100).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this block require external calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA026 comes factory-calibrated. However, it features self-calibration routines that run periodically to compensate for component aging and ambient temperature drifts, maintaining high accuracy over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the block handle sensor burnout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block detects an open circuit (burnout) and immediately reports a diagnostic fault to the controller. You can program the system to fail-safe by defining how the CPU should interpret the resulting out-of-range data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the terminal base included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA026 consists of the electronic module and the terminal block. Our\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits ship as complete assemblies ready for DIN-rail or panel mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447280033976,"sku":"IC660BBA026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBA026_2.jpg?v=1778231974"},{"product_id":"ge-fanuc-ic660bba025-genius-i-o-thermocouple-input-block","title":"GE Fanuc IC660BBA025 Genius I\/O Thermocouple Input Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA025 (IC660BBA025) functions as a specialized, 6-channel thermocouple input block within the GE Fanuc Genius I\/O ecosystem. This intelligent distributed module interfaces directly with Type J, K, T, E, R, S, and B thermocouples, as well as low-level mV signals. Designed for high-heat environments such as blast furnaces, glass manufacturing, and plastic injection molding, the IC660BBA025 eliminates the need for expensive thermocouple extension wire runs by digitizing signals at the point of measurement. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-sealed reliability and precise thermal calibration for your critical control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA025 features high-resolution A\/D conversion and integrated cold junction compensation (CJC) for superior measurement stability.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBA025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermocouple Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJ, K, T, E, R, S, B, and +\/-50mV or +\/-100mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 deg C or 1 microvolt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCold Junction Comp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic (Onboard thermistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.5 ms per enabled channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500V Peak between Genius bus and inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC \/ 230 VAC or 24\/48 VDC (Version dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalized Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy mounting the IC660BBA025 near the process, engineers significantly reduce signal degradation and EMI pickup associated with long-distance millivolt wiring. The block converts weak analog signals into robust digital packets for transmission over the Genius bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSophisticated Fault Profiling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors for \"Open Wire\" conditions and \"Out of Range\" values. It identifies a failed thermocouple immediately, allowing the control system to trigger safe-state logic or switch to a secondary sensor without manual intervention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis block utilizes advanced hardware filtering to reject 50\/60 Hz line noise, which often plagues temperature sensors located near heavy industrial motors or heaters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Commissioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal assembly detaches from the electronic module. This allows technicians to perform field wiring and testing before the electronics are even installed, accelerating the overall plant startup schedule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a separate compensation box for the cold junction?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC660BBA025 includes an integrated thermistor at the terminal assembly to perform automatic cold junction compensation. This ensures the digitized value reflects the absolute temperature of the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouple types on a single block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe configuration typically applies to all six channels globally. However, the block supports a mV mode, which offers flexibility for non-standard sensors if scaled correctly in the PLC logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Open Wire\" detection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block sources a tiny current through the thermocouple. If the sensor breaks or the wire detaches, the circuit opens, and the block immediately transmits a diagnostic \"Open Wire\" fault code over the Genius network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this block compatible with the 90-30 or 90-70 PLC series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC660BBA025 integrates with any GE Fanuc CPU equipped with a Genius Bus Controller (GBC), including legacy 90-series and modern PACSystems RX3i controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447308509368,"sku":"IC660BBA025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBA025_3.jpg?v=1778232089"},{"product_id":"ge-fanuc-ic660bbs103","title":"Genius I\/O 115 VAC Discrete Block GE Fanuc IC660BBS103","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBS103 (IC660BBS103) is a high-performance 16-circuit discrete I\/O block engineered for the GE Fanuc Genius network. This module provides a decentralized interface for 115 VAC digital signals, allowing for the direct control and monitoring of industrial hardware such as motor starters, solenoids, and limit switches. By distributing intelligence to the machine level, the IC660BBS103 eliminates the cost and complexity of home-run wiring to a central rack. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-original reliability for critical infrastructure in automotive, water treatment, and power generation sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBS103 features an integrated electronic design that supports flexible circuit configuration and robust electrical isolation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBS103\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Individually Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e93 to 132 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input\/Output (Triac Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A per circuit (Max 15 A per block)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V between Genius bus and I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndividually Configurable Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis block empowers engineers to define each of the 16 circuits as either an input or an output via software. This granular control reduces the need for multiple module types and simplifies the spare parts inventory for large-scale facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Load Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BBS103 utilizes high-speed electronic switching to detect \"Short Circuit\" and \"Overload\" conditions. The block immediately deactivates the affected circuit to prevent damage to field equipment while reporting the specific fault type to the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNo-Load Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA sophisticated diagnostic feature identifies a \"No-Load\" condition (such as a broken wire or burned-out bulb) even when the output is in the \"Off\" state. This proactive monitoring ensures that field devices are ready to operate when called upon.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Pluggable Electronics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe block consists of a terminal assembly and a separate electronic module. This design allows technicians to replace the electronic heart of the unit without disturbing the 115 VAC field wiring, significantly reducing Mean Time To Repair (MTTR) during process upsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix 115 VAC and 230 VAC signals on this block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC660BBS103 is specifically rated for 115 VAC operation. Attempting to connect 230 VAC signals will damage the internal circuitry. Always verify your field voltage before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the block require a handheld monitor for configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile you can use a Genius Hand-Held Monitor (HHM) for local configuration and troubleshooting, most modern setups allow for configuration directly through the PLC programming software (such as Proficy Machine Edition).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum load requirement for the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTriac-based outputs require a minimum holding current (typically around 50mA) to maintain the \"On\" state. If your load is extremely small, such as a high-impedance relay, you may need to install a bleeder resistor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this block compatible with the PACSystems RX3i?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When used with a Genius Bus Controller (GBC) module, the IC660BBS103 integrates seamlessly into RX3i architectures, providing a reliable bridge between legacy distributed I\/O and modern control processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447322304696,"sku":"IC660BBS103","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBS103_3.jpg?v=1778232196"},{"product_id":"ic660elb912-ge-fanuc-genius-i-o-electronic-assembly","title":"IC660ELB912 GE Fanuc Genius I\/O Electronic Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660ELB912 (IC660ELB912) is the core electronic assembly for the 16-circuit, 115 VAC discrete Genius I\/O block. This module contains the internal intelligence, processing circuitry, and communication interface required to manage digital inputs and outputs over a Genius network. It acts as the \"brain\" of the I\/O station, performing high-speed logic, circuit diagnostics, and data packet formation for the controller. Specifically designed to seat into a compatible terminal base, the IC660ELB912 allows for the rapid restoration of I\/O functionality without the need to rewire field connections. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, providing a factory-fresh solution for system expansions or the critical replacement of aged electronic components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660ELB912 utilizes advanced semi-conductor technology to provide reliable switching and diagnostic reporting for AC-powered field devices.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660ELB912\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Discrete Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e93 to 132 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterfaces with IC660TBS... Terminal Bases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius Bus (Shielded Twisted Pair)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, Short Circuit, No-Load, Switch State\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Restoration Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660ELB912 features a plug-in design. When a hardware fault occurs, maintenance personnel simply swap the electronic assembly while leaving the existing terminal base and field wiring intact. This architecture slashes Mean Time To Repair (MTTR) from hours to minutes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Triac Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module employs robust Triac-based switching for its outputs. It includes integrated surge suppression to handle the inductive flyback commonly generated by industrial solenoids and contactors, ensuring a longer operational lifespan for the internal switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Network Reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module does more than just switch signals; it continuously monitors the health of the field load. It detects a blown fuse or a disconnected wire even when the output is turned off, reporting these status updates globally across the Genius network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic I\/O Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal processor synchronizes all 16 circuits and manages communication timing locally. This offloads the primary PLC CPU from mundane I\/O management tasks, allowing for faster total system scan times and more responsive control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this include the terminal base where the wires connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC660ELB912 is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectronic Assembly only\u003c\/strong\u003e. It is designed to be inserted into an existing Genius terminal base (such as an IC660TBS series). If you require a complete block, please contact our sales team for the full assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this to replace an IC660BBS103 electronic unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC660ELB912 is the specific replacement electronic module for the BBS103 block. Ensure your system voltage is 115 VAC before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the block address on this new module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can set the Genius bus address and circuit configurations (Input\/Output) using a Genius Hand-Held Monitor (HHM) plugged into the front serial port, or via the PLC software configuration once the module is online.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with modern 24V DC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module is strictly for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e115 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications. Using this module with DC field voltages will result in improper operation and may damage the Triac switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447322828984,"sku":"IC660ELB912","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660ELB912_2.jpg?v=1778232329"},{"product_id":"ge-fanuc-ic660bbd024-genius-i-o-24-48-vdc-discrete-block","title":"GE Fanuc IC660BBD024 Genius I\/O 24\/48 VDC Discrete Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBD024 (IC660BBD024) is an intelligent, 16-circuit discrete I\/O block designed for the GE Fanuc Genius distributed control system. This module provides a robust interface for 24 VDC or 48 VDC field devices, utilizing sourcing logic to drive and monitor industrial components. Engineered for high-speed automated environments such as assembly lines, food processing, and material handling, the IC660BBD024 functions as a standalone I\/O node that communicates over a shielded twisted-pair Genius bus. By placing I\/O points closer to the process equipment, it eliminates expensive wiring home-runs and simplifies system maintenance. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-original performance for your critical automation infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBD024 features a high-density electronic design that supports per-point configuration and comprehensive electrical protection.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBD024\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Individually Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC or 48 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 56 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input\/Output (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A per circuit (Max 8 A total per block)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V between Genius bus and I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort Circuit, Overload, No-Load, Failed Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Circuit Programming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis block grants engineers the flexibility to configure each of the 16 circuits as either an input or an output via software. This versatility reduces the number of distinct spare parts required in inventory and allows for late-stage design changes without hardware swaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Diagnostic Reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660BBD024 monitors the health of each connected load. It identifies and reports specific faults—such as an open wire (No-Load) or a short circuit—directly to the PLC. This enables maintenance personnel to locate field faults immediately without manual point-to-point testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Sourcing Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module employs sourcing (high-side) switching, which is the preferred standard for many industrial safety and control protocols. The internal electronics are hardened against the voltage spikes and electrical noise typical of DC motor and solenoid operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Part Modular Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module consists of a terminal assembly for field wiring and a plug-in electronic assembly. This allows for \"hot\" replacement of the electronics without disturbing the field wiring or the physical mounting, drastically reducing Mean Time To Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this block support 24 VDC and 48 VDC simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block operates within a range of 18 to 56 VDC. While it can handle either 24V or 48V systems, all circuits on a single block typically share the same power source connected to the terminal assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the IC660BBD020?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBD024 is optimized for sourcing configurations and often features specific diagnostic thresholds or hardware revisions suitable for 24\/48V applications. Always check your wiring diagram to ensure sourcing vs. sinking compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a handheld monitor to set the bus address?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can use a Genius Hand-Held Monitor (HHM) for local addressing and testing. Alternatively, you can configure the block through your PLC programming software (e.g., Proficy Machine Edition) once it is connected to a Genius Bus Controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with the PACSystems RX3i?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC660BBD024 integrates perfectly with modern PACSystems RX3i controllers via a Genius Bus Controller (GBC) module, providing a reliable migration path for legacy Genius I\/O installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447324500152,"sku":"IC660BBD024","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBD024_3.jpg?v=1778232472"},{"product_id":"ic660ebd022-genius-i-o-discrete-electronic-assembly-ge-fanuc","title":"IC660EBD022 Genius I\/O Discrete Electronic Assembly GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660EBD022 (IC660EBD022) functions as the high-intelligence electronic assembly for the 16-circuit, 24\/48 VDC sourcing discrete Genius I\/O block. This module serves as the operational core of the I\/O station, housing the microprocessor, Genius network interface, and high-speed switching circuitry. Designed for distributed control in demanding environments like automotive manufacturing, bottling plants, and material handling systems, the IC660EBD022 digitizes field signals and executes local diagnostics at the source. It seats directly into a compatible terminal base, allowing for instantaneous hardware restoration. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring your system maintains peak deterministic performance and factory-spec reliability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660EBD022 utilizes high-side sourcing logic and advanced power semiconductors to interface with 24 VDC and 48 VDC industrial field devices.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660EBD022\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCircuit Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Discrete Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC or 48 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 56 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSourcing (High-Side Switching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius Bus (153.6 Kbaud or 76.8 Kbaud)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V between Genius bus and I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort Circuit, Overload, No-Load, Switch Health\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Field Replacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC660EBD022 features a modular \"plug-in\" architecture. If a circuit failure occurs due to extreme field conditions, technicians replace only this electronic module while leaving the terminal base and field wiring undisturbed. This eliminates wiring errors and slashes system downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Sourcing Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module employs sourcing outputs, which provide power to the load from the positive rail. This is the preferred industrial standard for safety, as it prevents accidental machine activation in the event of a field wire grounding fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Circuit Surveillance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 16 points includes independent diagnostic monitoring. The module detects \"No-Load\" conditions (broken wires) and \"Short Circuits\" in real-time, transmitting specific fault codes to the PLC for immediate operator notification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutonomous Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal processor manages the timing and synchronization of all 16 channels locally. It ensures that critical input data reaches the CPU and output commands execute with sub-millisecond precision, regardless of the overall PLC scan time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a complete I\/O block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC660EBD022 is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectronic Assembly only\u003c\/strong\u003e. It requires a compatible Genius terminal base (such as an IC660TBS series) to function. It is intended as a replacement or upgrade for the electronic portion of a BBD-series block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the IC660EBD024?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both are DC sourcing modules, the IC660EBD022 is the specific revision or version required for certain block assemblies. Always match the \"EBD\" number to your existing electronic module to ensure full software and hardware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the baud rate on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can set the Genius bus baud rate (typically 153.6 Kbaud) using a Genius Hand-Held Monitor (HHM) plugged into the front port, or via your controller's hardware configuration software during the initial setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support 24V and 48V on the same block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware supports the full range of 18-56 VDC. However, for signal integrity, you should power all 16 circuits on the associated terminal base from a single, consistent power source (either 24V or 48V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447353565368,"sku":"IC660EBD022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660EBD022_2.jpg?v=1778232605"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/ge-genius-i-o.oembed","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}