{"title":"GE Multilin","description":"\u003cp\u003eThe GE Multilin series is the industry standard for power system protection and substation automation. This collection includes motor protection, feeder protection, and transformer relays designed to safeguard electrical assets from faults and operational anomalies. These devices are critical for integrating advanced monitoring and control within power distribution networks. Our Multilin inventory focuses on providing the necessary hardware to maintain power system reliability, supporting high-speed communications and precise protection logic to prevent costly equipment damage and unplanned outages in utility and industrial applications.\u003c\/p\u003e","products":[{"product_id":"ur-67h-ge-12a0-0006-c6-multilin-relay-output-card","title":"UR-67H GE | 12A0-0006-C6 Multilin Relay Output Card","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR67H Universal Relay 8 Form-A Digital Output Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR67H (Model: UR-67H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital output expansion card designed for the GE Multilin Universal Relay (UR) platform. This module is specifically engineered to provide 8 Form-A (Normally Open) relay outputs, which are critical for executing automated control actions such as circuit breaker tripping, closing commands, and auxiliary alarm signaling. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR67H (Part Number: 12A0-0006-C6)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates directly into the UR series chassis (including B30, C30, D60, and G60), providing the physical switching interface required for substation automation and industrial power management.\u003c\/p\u003e\n\u003cp\u003eEquipped with dry-contact outputs, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR67H (Model: UR67H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles the rugged demands of utility-grade environments. Each of the 8 channels is designed with high dielectric strength and electrical isolation to prevent field-side surges from damaging the relay's central processing unit. This module supports the E-E-A-T (Expertise, Authoritativeness, Trustworthiness) standards necessary for power protection infrastructure, ensuring deterministic response times and reliable operation even under extreme temperature fluctuations ranging from –40°C to +85°C.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR67H (Model: UR-67H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for low power consumption and robust contact ratings.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (GE Fanuc Legacy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR-67H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e12A0-0006-C6\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUR Series Universal Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Form-A (Normally Open) Contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry Contact, Non-monitored\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 250 VDC \/ 250 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard auxiliary load (Breaker coils, lockout relays)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C (Utility Grade)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnerVista UR Setup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-in module for 6U UR Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.75 cm x 9.50 cm x 3.50 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 - 1.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ Canada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508906324152,"sku":"UR67H","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/66..jpg?v=1769584090"},{"product_id":"ge-ur-8fh-part-ur8fh-universal-relay-analog-module","title":"GE UR-8FH Part # UR8FH | Universal Relay Analog Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR8FH Universal Relay 8-Channel Analog Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8FH (Model: UR8FH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision Analog Input Module (AIM) specifically engineered for the GE Multilin Universal Relay (UR) series. As a critical interface for power system monitoring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8FH (Part Number: UR8FH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates the acquisition of secondary signals from Current Transformers (CTs) and Potential Transformers (PTs). It translates these high-voltage\/high-current electrical variables into a 16-bit digital format that the relay's central processing unit can use for protective logic, metering, and oscillography.\u003c\/p\u003e\n\u003cp\u003eBuilt for utility-grade reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8FH (Model: UR8FH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures signal integrity through comprehensive galvanic and optical isolation. This architecture prevents severe system transients—such as those occurring during a primary fault—from reaching the sensitive microprocessor backplane. The module is capable of supporting both current and voltage acquisition, making it the backbone for functions like overcurrent protection, distance elements, and power quality monitoring. Its wide operating temperature range ensures consistent performance in the most demanding substation environments, upholding the E-E-A-T (Expertise, Authoritativeness, Trustworthiness) standards of the GE Multilin series.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8FH (Model: UR8FH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-speed sampling and precise conversion of analog waveforms.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR8FH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Module (AIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 independent analog input channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Current (CT) and AC Voltage (PT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCT Input Nominal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A or 5 A (Configurable via relay order code)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePT Input Nominal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 300 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.2% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Hz and 60 Hz systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV AC dielectric strength\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnerVista UR Setup software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm x 105 mm x 32 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508907077816,"sku":"UR8FH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/67..jpg?v=1769584599"},{"product_id":"ur-8hh-ge-ur-8hh-universal-relay-8-output-form-c-control-board","title":"UR-8HH | GE UR 8HH Universal Relay 8-Output Form-C Control Board","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR8HH Universal Relay CT\/VT and Digital I\/O Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8HH (Model: UR8HH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized high-density expansion module for the GE Multilin Universal Relay (UR) series. This module is a hybrid interface component, combining critical analog Current Transformer (CT) and Voltage Transformer (VT) acquisition with robust digital input and output capabilities. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8HH (Part Number: UR-8HH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for complex protection schemes where both phase\/ground current sensing and auxiliary breaker control are required within a single slot of the UR chassis.\u003c\/p\u003e\n\u003cp\u003eEngineered for utility-grade reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8HH (Model: UR8HH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles 1A\/5A phase and ground CT inputs with high precision, alongside 16 optically isolated digital inputs and 8 Form-C relay outputs. This comprehensive integration allows the relay to perform high-speed protective calculations while simultaneously monitoring breaker status and executing trip\/close commands. Its utility-hardened design ensures stable operation in harsh substation environments, maintaining the E-E-A-T (Expertise, Authoritativeness, Trustworthiness) standards essential for modern power grid infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8HH (Model: UR8HH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates diverse signal types into a single modular footprint, optimized for space-saving protection architectures.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR8HH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCombined CT\/VT and Digital I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase CT Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Channels (Supports 1A or 5A nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGround CT Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Channel (Supports 1A or 5A nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Optically Isolated (24V to 250V DC range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Form-C Contacts (Normally Open\/Normally Closed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Contact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10A at 250 VAC \/ 30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2kV AC for 1 minute (Inputs\/Outputs to Ground)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board LEDs for I\/O status and health monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 6U UR Module (170 x 105 x 32 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.27 kg (5.00 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508911173816,"sku":"UR8HH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/68..jpg?v=1769585004"},{"product_id":"ge-multilin-ur-9eh-16-bit-d-a-analog-output-protection-card","title":"GE Multilin UR-9EH | 16-Bit D\/A Analog Output Protection Card","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR9EH Universal Relay 8-Channel Analog Output Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR9EH (Model: UR9EH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision Analog Output Module (AOM) designed for the GE Multilin Universal Relay (UR) series. This module serves as the primary interface for transmitting calculated system parameters—such as real-time power, frequency, or load levels—from the relay’s internal logic to external devices. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR9EH (Part Number: UR9EH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for integrating advanced protective relays with legacy SCADA systems, remote meters, and Distributed Control Systems (DCS) that require standard analog signals like 4-20 mA or 0-10 V.\u003c\/p\u003e\n\u003cp\u003eEngineered with 16-bit Digital-to-Analog (D\/A) conversion, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR9EH (Model: UR9EH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the control signals sent to external actuators or monitoring equipment are highly accurate and linear. To maintain the Expertise and Trustworthiness (E-E-A-T) required in utility substations, the module features full galvanic isolation. This protects the relay's central processing core from external ground loops or electrical surges that could originate from long-distance signal wiring in industrial plants or power generation facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR9EH (Model: UR9EH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-fidelity signal generation and seamless backplane integration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR9EH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output Module (AOM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent: 4–20 mA (typical); Voltage: 0–10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit D\/A conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.2% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical and Electrical (Output to Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board LEDs for module status and channel health\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C (Utility Grade)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-in module for UR 6U chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated via UR Relay internal bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-power design, sourced from chassis backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard UR Module (170 × 105 × 32 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, and Utility Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508913762488,"sku":"UR9EH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/69..jpg?v=1769585245"},{"product_id":"ge-ur-rhh-part-ur-rhh-multilin-universal-relay-supply","title":"GE UR-RHH Part # UR RHH | Multilin Universal Relay Supply","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin URRHH Universal Relay High Voltage Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eURRHH (Model: UR-RHH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized, high-capacity power supply module designed for the GE Multilin Universal Relay (UR) series. As a critical infrastructure component, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eURRHH (Part Number: URRHH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the necessary auxiliary power to drive the relay's internal logic, communication ports, and I\/O modules. It is engineered to support wide-range input voltages, making it compatible with both standard AC utility power and station DC battery banks, ensuring the protection relay remains operational during severe grid disturbances or total AC power loss.\u003c\/p\u003e\n\u003cp\u003eBuilt for maximum reliability in high-voltage environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eURRHH (Model: URRHH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures advanced galvanic isolation to decouple the sensitive microprocessor electronics from the noisy substation auxiliary power bus. This second-generation module is a \"High\" voltage variant (denoted by the 'HH' suffix), optimized for 125–250 VDC and 100–240 VAC applications. Its rugged construction and wide operating temperature range (-40°C to +85°C) meet the stringent E-E-A-T (Expertise, Authoritativeness, Trustworthiness) requirements for utility-grade protection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eURRHH (Model: UR-RHH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed as a plug-in module for the standard UR chassis, offering high efficiency and a modular maintenance path.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eURRHH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Voltage Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 VDC to 250 VDC (Operational range: 88–300 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 VAC to 240 VAC at 50\/60 Hz (Operational range: 88–265 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 W (DC) \/ 35 VA (AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHoldup Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypical 100ms at nominal voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.3 kV AC dielectric strength (Input to Backplane\/Chassis)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 cm x 22.5 cm x 29.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.62 kg (1.37 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCritical failure alarm contact (Form-C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated Power Supply Slot in UR Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508922118328,"sku":"URRHH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/70..jpg?v=1769585869"},{"product_id":"ur-8nh-ge-universal-relay-8-channel-current-voltage-module","title":"UR-8NH | GE Universal Relay 8-Channel Current\/Voltage Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR8NH Universal Relay 8-Channel CT\/VT Analog Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8NH (Model: UR8NH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Current Transformer\/Voltage Transformer (CT\/VT) interface module designed for the GE Multilin Universal Relay (UR) series. As a critical data acquisition component, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8NH (Part Number: UR8NH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the relay with 8 standard CT\/VT channels, enabling high-fidelity measurement of primary power system parameters. This module is essential for protection, monitoring, and metering applications in utility substations and heavy industrial plants, ensuring that the relay has the precise analog data required for complex protection algorithms.\u003c\/p\u003e\n\u003cp\u003eDesigned with the modularity of the Universal Relay platform in mind, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8NH (Model: UR8NH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for streamlined hardware upgrades or the replacement of legacy modules. It features advanced onboard diagnostics that continuously monitor the health of the transformers and internal A\/D converters. By converting high-level secondary currents and voltages into digital signals for the relay’s processor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains the E-E-A-T (Expertise, Authoritativeness, Trustworthiness) standards necessary for maintaining the stability and safety of critical power infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8NH (Model: UR8NH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-density analog acquisition with rugged electrical characteristics for substation environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE Multilin)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR8NH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCT\/VT Analog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (Standard 8CT configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Handling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent (CT) and Voltage (VT) signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1A \/ 5A (Field configurable depending on order code)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvanced self-testing and channel health monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-resolution sampling for waveform capture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 cm x 21.4 cm x 1.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 kg (1.98 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-in module for UR 6U chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull galvanic isolation between field and backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDesigned for IEEE and IEC protective relay standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508932538552,"sku":"UR8NH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/66._7be99af3-0632-4382-ade9-c3d4b1ac1dc4.jpg?v=1769586007"},{"product_id":"ge-multilin-ur-8lh-substation-breaker-control-output-module","title":"GE Multilin UR-8LH | Substation Breaker Control Output Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR8LH Universal Relay 24-Channel Digital Output Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8LH (Model: UR8LH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Output Module engineered for the GE Multilin Universal Relay (UR) series. Specifically designed to provide 24 independent Form-A (Normally Open) relay outputs, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8LH (Part Number: UR8LH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the critical execution interface between the relay's protective logic and substation primary equipment. This module is essential for complex automation schemes requiring multiple control points, such as circuit breaker trip\/close commands, lockout relay actuation, and multi-stage alarm signaling.\u003c\/p\u003e\n\u003cp\u003eUnlike standard I\/O boards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8LH (Model: UR8LH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures advanced internal diagnostics. It continuously monitors the integrity of its output drive circuitry; if a hardware failure is detected, the module triggers a self-test alarm and can be configured to block associated protection functions to prevent accidental misoperation. This ensures the highest level of Expertise and Trustworthiness (E-E-A-T) in utility-grade power system protection, where a single false trip can lead to widespread outages.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR8LH (Model: UR8LH)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-speed switching and robust electrical isolation in harsh EMI environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR8LH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Density Digital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Form-A (Normally Open) Contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A at 250 VAC \/ 30 VDC (Resistive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypical \u0026lt; 8 ms (Pickup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal failure detection and failure response alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C (Extended Utility Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV AC dielectric strength for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSourced from UR Relay backplane (5V\/12V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware-defined via EnerVista UR Setup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm x 105 mm x 32 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg (Module only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, IEEE C37.90\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508942172344,"sku":"UR8LH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/71..jpg?v=1769586264"},{"product_id":"t35-j03-akh-f8m-ge-multilin-transformer-differential-relay","title":"T35-J03-AKH-F8M | GE Multilin Transformer Differential Relay","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin T35 Transformer Protection Relay T35J03AKHF8MH6DM8RP6EU67WXX\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT35 (Model: T35J03AKHF8MH6DM8RP6EU67WXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance transformer protection system within the GE Multilin UR (Universal Relay) family. Specifically engineered for medium to large power transformers, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT35 (Order Code: T35-J03-AKH-F8M-H6D-M8R-P6E-U67-WXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides primary and backup protection, including high-speed differential, phase, and ground overcurrent elements. This relay is uniquely capable of accepting up to 6 sets of current inputs, making it the ideal solution for complex three-winding transformers configured in dual-breaker or breaker-and-a-half arrangements.\u003c\/p\u003e\n\u003cp\u003eOperating on the industry-leading UR platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT35 (Model: T35J03AKHF8MH6DM8RP6EU67WXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures Expertise and Trustworthiness (E-E-A-T) through advanced features like restricted earth fault (REF), thermal overload monitoring, and overexcitation protection. It integrates seamlessly into modern digital substations via IEC 61850 and supports embedded Synchrophasors (PMU), allowing for real-time wide-area monitoring and enhanced grid stability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT35 (Order Code: T35-J03-AKH-F8M-H6D-M8R-P6E-U67-WXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built with modular hardware designed for extreme utility environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (GE Grid Solutions)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eT35J03AKHF8MH6DM8RP6EU67WXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUR Series Universal Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransformer Protection Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 6 CT input sets for differential restraint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDifferential (87T), REF (87N), Overcurrent (50\/51), Breaker Failure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver\/Under Voltage (27\/59), Overexcitation (24)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Engine\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexLogic™ programmable logic for custom automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61850, Modbus TCP\/RTU, DNP 3.0, Ethernet Global Data (EGD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchrophasor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmbedded PMU per IEEE C37.118\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEvent Recording\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64-sample\/cycle oscillography; 1024 sequence-of-events records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCyberSentry™ role-based access control and secure protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e635g (Module context); 1.9kg (Full Relay weight typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnerVista™ UR Setup and Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52508987818168,"sku":"T35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/73..jpg?v=1769586976"},{"product_id":"f35-f53u04-hkh-ge-multilin-feeder-protection-module","title":"F35-F53U04-HKH | GE Multilin Feeder Protection Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin F35 Feeder Protection System F53U04HKHF8LH6TM6EP6TUXXWXX\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF35 (Model: F53U04HKHF8LH6TM6EP6TUXXWXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, cost-effective feeder protection relay from the GE Multilin UR (Universal Relay) family. This integrated platform provides protection, control, and metering for up to five feeders with busbar voltage measurement, or up to six feeders without busbar voltage in a single chassis. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF35 (Order Code: F53U04HKHF8LH6TM6EP6TUXXWXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for utility-scale distribution and industrial power systems, offering a modular architecture that reduces the physical footprint in control cabinets while increasing system reliability through high-speed processing and synchronized sampling.\u003c\/p\u003e\n\u003cp\u003eOperating as a standalone protective device or as a core component of an automated substation control system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF35 (Model: F53U04HKHF8LH6TM6EP6TUXXWXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in demanding environments. It features extensive I\/O flexibility and advanced protection elements, including directional overcurrent, thermal image protection, and load shedding. Its adherence to IEC 61850 and IEEE C37.118 (Synchrophasors) ensures seamless integration into modern digital grids, providing engineers with high-fidelity data and deterministic control logic through the proprietary FlexLogic™ engine.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF35 (Order Code: F53U04HKHF8LH6TM6EP6TUXXWXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-density feeder management and comprehensive fault recording.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (GE Grid Solutions)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF53U04HKHF8LH6TM6EP6TUXXWXX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFeeder Protection \u0026amp; Control Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50P\/51P, 50G\/51G, 67P\/67G, 46, 49, 27, 59, 81U\/O, 79 (Autoreclosing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFeeder Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5 feeders with bus VT \/ Up to 6 feeders without bus VT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable CT\/VT modules (Standard 1A\/5A secondary)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Engine\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexLogic™ (up to 1024 lines of programmable logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61850, Modbus TCP\/RTU, DNP3, EGD, IEC 60870-5-104\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchrophasor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmbedded PMU per IEEE C37.118\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecording\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64-sample\/cycle oscillography; 1024 sequence-of-events records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCyberSentry™ (RBAC, Syslog, Secure Protocols)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-voltage Universal AC\/DC auxiliary power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnerVista™ UR Setup and Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52509025501368,"sku":"F35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/72._1303388f-627a-495d-9525-149a0158de35.jpg?v=1769587683"},{"product_id":"ge-multilin-239-an-h-motor-protection-relay-conformal-coated","title":"GE Multilin 239-AN-H | Motor Protection Relay Conformal Coated","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin 239-AN-H 3-Phase Motor Protection Relay 250VAC 10A\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e239-AN-H (Model: 239-AN-H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance microprocessor-based relay designed to provide comprehensive protection for three-phase AC motors and their associated mechanical equipment. As part of the GE Multilin 239 series, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e239-AN-H (Part Number: 239-AN-H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically safeguards against conditions that cause motor damage, such as thermal overload, phase unbalance, and ground faults. This specific \"-H\" variant is equipped with a Harsh Environment Conformal Coating, protecting the internal circuitry from moisture, dust, and chemical contaminants common in industrial processing.\u003c\/p\u003e\n\u003cp\u003eBeyond electrical protection, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e239-AN-H (Model: 239-AN-H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a diagnostic tool for maintenance engineers. It provides pre-emptive alarms before a process malfunction results in physical damage and allows for detailed post-fault analysis through event recording. By integrating a sophisticated thermal model with programmable logic, the relay prevents motor overheating while allowing for maximum operational efficiency, ensuring long-term reliability for medium-sized motors in manufacturing and utility sectors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e239-AN-H (Model: 239-AN-H)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for versatile power compatibility and robust switching capacity.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e239-AN-H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e239 Motor Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolid State Overload \/ Motor Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70–265 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90–300 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 W Max \/ 30 VA Max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Amp at 250 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Overload, Ground Fault, Phase Unbalance, Jam, Undercurrent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInhibit Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRestart Inhibit (Thermal and Time-based)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485 Port (Modbus RTU support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHarsh Environment Conformal Coating (-H option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.81 kg (4.00 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED Indicators and alphanumeric keypad\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52509046964408,"sku":"239-AN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/75..jpg?v=1769588113"},{"product_id":"m60-ge-multilin-87m-stator-differential-thermal-relay","title":"M60 | GE Multilin 87M Stator Differential \u0026 Thermal Relay","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin M60 Universal Relay Motor Protection System\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM60 (Model: M60)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a flagship Motor Protection System within the GE Multilin UR (Universal Relay) family, specifically engineered for the comprehensive protection and control of medium to large-sized three-phase motors. As a high-performance Intelligent Electronic Device (IED), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM60 (Part Number: M60)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates advanced electrical, mechanical, and thermal protection elements into a single modular chassis. It is designed to handle complex motor applications, including two-speed motors, reduced voltage starting, and high-inertia loads in heavy industries like mining, petrochemicals, and power generation.\u003c\/p\u003e\n\u003cp\u003eAt its core, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM60 (Model: M60)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a sophisticated thermal model that utilizes RTD inputs and current unbalance biasing to accurately track the motor's thermal state. This ensures maximum operational uptime while providing fail-safe protection against stator differential faults, broken rotor bars, and loss of excitation. With support for IEC 61850 and embedded synchrophasors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebridges the gap between traditional motor protection and modern digital substation automation, delivering the reliability (E-E-A-T) required for critical infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM60 (Model: M60)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides utility-grade sensing and high-speed logic for demanding industrial environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Grid Solutions (GE Multilin)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eM60\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUR Series Universal Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Protection \u0026amp; Control System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Model (49), Stator Differential (87M), Broken Rotor Bar, Undercurrent (37)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase Unbalance (46), Ground Fault (50G\/51G), Jam\/Locked Rotor (48)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage\/Freq\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnder\/Over Voltage (27\/59), Under\/Over Frequency (81U\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports internal RTD modules or external RRTD modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Engine\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlexLogic™ programmable logic (up to 1024 lines)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61850, Modbus TCP\/RTU, DNP3, EGD, Ethernet Global Data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchrophasor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmbedded PMU per IEEE C37.118\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRecording\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64-sample\/cycle oscillography; 1024 sequence-of-events records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 19-inch 6U UR Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52509125148856,"sku":"M60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/72_d81cb812-5839-40a5-ac5b-1a6999bdaa00.jpg?v=1769588926"},{"product_id":"ur-6av-ge-multilin-24v-250vdc-digital-i-o-relay-module","title":"UR-6AV | GE Multilin 24V-250VDC Digital I\/O Relay Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Multilin UR6AV Universal Relay Digital I\/O Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR6AV (Model: UR6AV)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input\/output module specifically engineered for the GE Multilin UR (Universal Relay) series. As a critical component of the modular UR platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR6AV (Part Number: UR6AV)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the hardware interface necessary for the relay to communicate with external primary equipment such as circuit breakers, disconnect switches, and alarm panels. This module is essential for substation automation and industrial power system protection, allowing for real-time status monitoring and deterministic control execution.\u003c\/p\u003e\n\u003cp\u003eDesigned to handle the rigorous transients found in utility environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR6AV (Model: UR6AV)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 24 optically isolated channels that support a wide DC voltage range. These inputs are equipped with high-speed hardware filtering to ensure signal integrity against electromagnetic interference (EMI). By integrating the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR6AV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto a UR-series chassis (such as the B30, C60, or F35), engineers gain a scalable and reliable (E-E-A-T) solution for complex automation logic, managed through the FlexLogic™ engine and EnerVista™ software suite.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR6AV (Part Number: UR6AV)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-speed signal acquisition and robust electrical isolation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUR6AV\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniversal Relay (UR) Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Optically Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC to 250 VDC (Universal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Filtering\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 ms Hardware Filter (Noise Immunity)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable Relay Contacts (Form-A\/Form-C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 2 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 V per minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP, RS-485, Ethernet (via UR CPU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board LED Status Indicators per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–10°C to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModular UR Chassis Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52509163782328,"sku":"DS200TCDAH1BHE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/69._eb488bbf-b38e-4e80-a96f-54505a719dff.jpg?v=1769591813"},{"product_id":"735-5-5-hi-485-ge-multilin-5a-ct-feeder-protection-relay","title":"735-5-5-HI-485 GE Multilin 5A CT Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(also referred to as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSR-735-5-5-HI-485\u003c\/strong\u003e) is a robust, microprocessor-based feeder protection relay designed for the comprehensive management of electrical distribution systems. As part of the standard 735 series, this unit integrates essential protection elements, including phase overcurrent (50\/51) and ground overcurrent (50G\/51G) functions. It is engineered to safeguard critical electrical assets in substations, switchgear, and industrial power monitoring systems by providing high-speed fault detection and trip signaling.\u003c\/p\u003e\n\u003cp\u003eEquipped with a high-voltage (HI) power supply, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates reliably across a wide range of AC and DC inputs, making it adaptable to various station battery or auxiliary power configurations. The inclusion of an RS485 2-wire communication port allows for seamless integration into SCADA systems and power monitoring networks via the Modbus RTU protocol, enabling remote monitoring of electrical parameters and relay status.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the detailed technical configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotection module.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetailed Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/51 (Phase), 50G\/51G (Ground) Overcurrent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase CT Secondary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGround CT Secondary\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply (HI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90–300 V DC or 70–265 V AC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485 (2-wire serial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU \/ Proprietary GE Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable up to 19200 bps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel-mounted Protective Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Form-C Relay Contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.79 lbs (5.35 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52525839417528,"sku":"735-5-5-HI-485","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/92..jpg?v=1770105010"},{"product_id":"ge-469-p5-hi-a20-t-h-motor-management-relay-with-coating","title":"GE 469-P5-HI-A20-T-H Motor Management Relay with Coating","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003eComprehensive Protection for High-Inertia Motors\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated microprocessor-based relay designed for the protection, management, and monitoring of medium to large horsepower motors. This specific configuration of the 469 series provides a robust thermal model that accounts for motor heating due to negative sequence currents, cyclic loading, and ambient temperature. By integrating voltage-dependent overload curves and torque metering, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that high-inertia starts are managed safely, preventing premature insulation failure while maximizing motor service life in demanding industrial sectors like oil \u0026amp; gas, mining, and water treatment.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Asset Monitoring and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eBeyond basic electrical protection, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers specialized mechanical protection features, including broken rotor bar detection and bearing vibration monitoring via analog inputs. The unit’s \"HI\" control power range (90–300 VDC or 70–265 VAC) ensures operational stability across varying grid qualities. With its integrated oscillography and event recording capabilities, maintenance teams can perform detailed root-cause analysis of trips, significantly reducing troubleshooting time. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealso features a \"T\" suffix indicating optional conformal coating, providing superior protection against humidity and chemically corrosive atmospheres common in chemical processing plants.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table details the electrical and operational parameters for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Multilin (GE Digital Energy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultilin 469 Motor Management\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase Current Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A Phase CT Secondaries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Power (HI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90–300 VDC; 70–265 VAC @ 48–62 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA (A20 configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (T-option) included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRTD Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 assignable RTD inputs (100 Ohm Pt\/Ni\/Cu)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver\/undervoltage, phase reversal, frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent, Voltage, Power, Torque, Energy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnhanced Front Panel with LCD and Keypad\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232, RS485 (Modbus RTU), optional Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 kg (Including robust industrial packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":52528910794936,"sku":"469-P5-HI-A20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/202..jpg?v=1770197671"},{"product_id":"100-fsv136-allen-bradley-iec-100c-series-ac-dc-mov-surge-suppressor","title":"100-FSV136 | Allen-Bradley IEC 100C Series AC\/DC MOV Surge Suppressor","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 100-FSV136\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a metal-oxide varistor (MOV) surge suppressor module designed to provide overvoltage protection for IEC 100-C contactors. It effectively limits coil-switching transients and suppresses voltage surges during switching operations, ensuring reliable performance and extended component life. Suitable for both AC and DC control circuits, this module features robust screw terminal connections for secure installation and long-term operation in industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC 100 Contactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100-FSV136\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSurge Suppressor, Varistor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUPC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e662072613894\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.00 lbs (1.36 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100-C with AC Coils, 100-C09 to 100-C43 with DC Coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e56–136V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e78–180V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Frequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSurge protection and limitation of coil-switching transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Mechanism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with both AC and DC control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScrew-type terminals for secure wiring connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect mounting on compatible contactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 100-FSV136 is designed for use in electrical control panels and automation systems where voltage spikes can affect the reliability of contactor coils.\u003cbr\u003eCommon applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMotor control centers and starter panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConveyor and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower distribution and switching cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComparison with Similar Models\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100-FSA136:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiode surge suppressor for DC-only applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100-FSB136:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRC suppressor for AC coil protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100-FSV136:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMOV suppressor for AC\/DC versatility and higher voltage range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 100-FSV136 be used on both AC and DC circuits?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, it supports both AC and DC applications within the specified voltage ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does this module protect contactors?\u003c\/strong\u003e\u003cbr\u003eA2: It absorbs transient voltage spikes generated during coil de-energization, preventing insulation stress and extending contactor life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is additional wiring required for installation?\u003c\/strong\u003e\u003cbr\u003eA3: No. The module mounts directly on compatible 100-C series contactors using screw terminals for straightforward integration.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":52828184412344,"sku":"100-FSV136","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/100-FSV136.jpg?v=1770801084"},{"product_id":"plx31-eip-mbs4-prosoft-ethernet-ip-to-modbus-four-port-gateway","title":"PLX31-EIP-MBS4 | ProSoft | EtherNet\/IP to Modbus Four-Port Gateway","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-MBS4\u003c\/strong\u003e Gateway is designed to connect EtherNet\/IP networks with Modbus serial devices. Featuring four isolated serial ports, it supports multiple simultaneous connections and ensures reliable communication in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003ePLX31-EIP-MBS4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: EtherNet\/IP to Modbus Serial Four-Port Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClass 3 Server Connections: 5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClass 1 I\/O Connections: 8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eI\/O Connection Sizes: 248\/248\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMax RPI Time: 5 ms per connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNominal: 24 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRange: 10–36 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Load: 300 mA @ 24 V DC nominal, 610 mA maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: 4 isolated ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -25°C to +70°C (-13°F to +158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +80°C (-40°F to +176°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5%–95% RH, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e: IEC 60068-2-6; 5G @ 10–150 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e: 13.67 × 5.05 × 11.13 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour-port Modbus serial gateway for expanded connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports multiple EtherNet\/IP Class 1 and Class 3 connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFast RPI times for real-time communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide operating temperature range for industrial use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design suitable for control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of Modbus devices into EtherNet\/IP networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSubstation automation and machine control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial communication requiring multi-port protocol conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems with high connection density\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many serial ports does the PLX31-EIP-MBS4 provide?\u003c\/strong\u003e  A: It includes four isolated serial ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum RPI time supported?\u003c\/strong\u003e  A: 5 ms per connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e  A: -25°C to +70°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the shipping weight of the unit?\u003c\/strong\u003e  A: Approximately 3 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52911684485304,"sku":"PLX31-EIP-MBS4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBS_55176e0e-0b40-4004-9ef2-36eb3be17ca6.jpg?v=1772698355"},{"product_id":"2080-lc30-48qwb-allen-bradley-micro830-programmable-logic-controller","title":"2080-LC30-48QWB | Allen Bradley | Micro830 Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2080-LC30-48QWB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the cornerstone of the Micro830 family, designed specifically for standalone machine control applications. This high-capacity controller integrates 48 embedded I\/O points, offering an ideal balance of performance and flexibility for small to mid-sized industrial systems. It supports up to five plug-in modules, allowing engineers to customize the controller’s hardware profile without increasing its physical footprint. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Original\u003c\/strong\u003e, ensuring your automation project utilizes the latest hardware revisions for maximum service life.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 2080-LC30-48QWB leverages a robust hardware architecture to manage diverse discrete signals and high-speed counting tasks:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicro830\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Embedded I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\/AC Sink\/Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHigh Speed Counters (HSC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlug-In Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBase Serial Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232\/485 (Non-Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Digital I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e88 Points (via expansion)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs (0.91 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomizable Small-Footprint Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe five integrated plug-in slots permit the addition of analog I\/O, specialized communication, or extra digital points directly onto the controller face. This capability eliminates the need for external expansion racks, saving critical DIN rail space in compact control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Relay Output Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 20 relay outputs handle diverse voltage ranges and load types, including solenoids and small motor starters. This built-in hardware removes the requirement for interposing relays in many standard applications, reducing wiring complexity and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Motion and Counting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix High-Speed Counters (HSC) monitor fast pulse inputs from encoders and proximity sensors. This enables the controller to execute precise positioning and frequency measurement tasks necessary for high-speed conveyor and packaging logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Serial Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe non-isolated RS-232\/485 serial port supports Modbus RTU and ASCII protocols. This interface facilitates direct connection to HMI terminals, barcode scanners, and variable frequency drives (VFDs) without necessitating expensive network adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Programming Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller utilizes Connected Components Workbench (CCW) software. This unified environment accelerates development by providing standard PLC editors (Ladder Diagram, Function Block, Structured Text) alongside graphical configuration tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this 2080-LC30-48QWB unit 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this controller arrives in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, contained in its original factory packaging with all sealings intact. We do not sell refurbished or used stock, ensuring you receive the full industrial reliability of new hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software do I need to program the Micro830?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConnected Components Workbench (CCW)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. This Rockwell Automation software supports the entire Micro800 family and allows for seamless configuration of the embedded I\/O and any added plug-in modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I expand this controller beyond the 48 embedded I\/O points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. By utilizing the 5 plug-in slots and adding expansion I\/O modules, you can increase the total digital I\/O count to a maximum of 88 points, providing significant headroom for future machine upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Micro830 handle power-loss events?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2080-LC30-48QWB features non-volatile memory to protect your application code and data. It does not require a battery for program retention, which simplifies long-term maintenance cycles and improves overall system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53453106151608,"sku":"2080-LC30-48AWB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2080-LC30-48AWB.png?v=1778487235"},{"product_id":"allen-bradley-2080-lc30-16qwb-micro830-programmable-logic-controller","title":"Allen Bradley 2080-LC30-16QWB Micro830 Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2080-LC30-16QWB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a cornerstone for standalone machine control within the Micro830 family. This compact yet powerful PLC provides 16 integrated I\/O points, specifically designed for small-scale industrial applications requiring precise relay switching and flexible input voltage handling. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory sealed\u003c\/strong\u003e, providing a robust hardware foundation for your essential automation tasks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 2080-LC30-16QWB integrates diverse I\/O and communication capabilities into a single DIN-rail mountable chassis:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Integrated I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Points (24V DC\/AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Points (Relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Speed Counters (HSC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4K Steps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8K Bytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlug-In Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Available Slots for Expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x USB 2.0 (Programming); 1 x RS232\/RS485 Combo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU (Master\/Slave), ASCII, CIP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAdvanced Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePID Control, Floating Point Math, User Defined Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Input Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10 integrated inputs accept both 24V DC and 24V AC signals. This dual-voltage capability allows engineers to interface with a wider variety of field devices without adding interposing relays or secondary power converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo integrated plug-in slots enable the addition of analog I\/O, specialized communication modules, or additional memory without increasing the footprint of the PLC. This allows for system scaling while maintaining a compact control cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmbedded Serial Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe non-isolated RS-232\/485 combo port supports Modbus RTU and ASCII. This enables direct communication with VFDs, temperature controllers, and other serial peripherals, eliminating the cost of external communication bridges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSophisticated Instruction Set:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its micro-scale categorization, the 2080-LC30-16QWB supports floating-point math and PID control loops. These features empower engineers to execute complex arithmetic and closed-loop process control directly on a cost-effective controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I program the 2080-LC30-16QWB using a standard USB cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The controller features a built-in USB 2.0 port that accepts a standard USB printer cable for programming via Connected Components Workbench (CCW) software, removing the need for proprietary programming cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the Relay output type in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay outputs provide high-current switching capacity and electrical isolation for both AC and DC loads. This makes the 16QWB ideal for controlling diverse hardware like solenoids, contactors, and small motors that require more than simple transistor-level signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this PLC support expansion beyond the two plug-in slots?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Micro830 series focuses on plug-in modularity. While it does not support the larger side-car expansion modules found on the Micro850, the two plug-in slots provide sufficient flexibility for most standalone machine requirements while keeping the total digital I\/O count up to 32.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the RS485 port for a multi-drop network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The combo port supports RS485, allowing you to configure the PLC as a Modbus RTU Master to control multiple nodes (such as PowerFlex drives) across a single twisted-pair network.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53455457550520,"sku":"2080-LC30-16QWB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2080-LC30-16QWB.jpg?v=1778554248"},{"product_id":"mark-vie-turbine-specific-i-o-pack-is220pturh1b-ge","title":"Mark VIe Turbine Specific I\/O Pack IS220PTURH1B GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS220PTURH1B operates as a high-reliability, turbine-specific I\/O pack within the General Electric Mark VIe Speedtronic control platform. This primary module interfaces directly with critical turbine machinery components, processing input signals from magnetic pickups, automatic synchronizing sub-systems, and shaft voltage monitors. It translates specialized sensor frequencies and structural telemetry into digitized data packet networks across the plant control layer. The local microprocessor core evaluates speed acceleration profiles in real time, serving as a foundational pillar for safety actuation and automated startup sequences in utility-scale gas and steam turbines.\u003c\/p\u003e\n\u003cp\u003eWe supply this crucial component exclusively as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed inventory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee complete component lifespan and zero operational defects within your governor control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS220PTURH1B incorporates complex speed-tracking hardware and signal isolation filters inside a compact, panel-mountable housing. The following table highlights the definitive electronic, networking, and physical specifications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220PTURH1B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePTUR (Turbine Specific Application Pack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePulse Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports multiple Magnetic Pickup (MPU) speed sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrates generator line and bus voltage sensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Framework\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 10\/100 Mbps Ethernet Ports via dual IONet redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 V DC nominal (Range parameters: 18.5 to 32.0 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 W Maximum under full operational load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC galvanic isolation for field-side inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 industrial enclosure rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Pulse Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard hardware counters capture high-frequency pulses from magnetic pickup sensors on the turbine shaft. This direct tracking allows the module to calculate rotational speed variations down to fractions of an RPM, enabling instant reactions to sudden load rejection events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant IONet Network Pathing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual RJ-45 Ethernet connection ports link independently into the internal IONet fabric. This configuration maintains uninterrupted speed telemetry streaming to the main controller even if a physical network cable breaks or suffers a terminal breakdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Generator Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe circuit design handles voltage and phase matching directly at the I\/O pack layer. By merging automatic synchronization monitoring with speed control, the module eliminates external matching components and shortens breaker closure windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFanless Convection Heat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rigid metal housing relies entirely on a passive external heat sink matrix for thermal regulation. Eliminating moving cooling fans prevents dust collection across internal circuit traces, maximizing operational uptime in hot turbine control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat technical updates does the 'H1B' suffix introduce over the older 'H1A' pack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"H1B\" hardware revision replaces obsolete internal chips with updated silicon baselines, which lowers heat dissipation and improves component long-term stability. The \"H1B\" maintains complete backward compatibility and drops directly onto the identical terminal board configurations used by the \"H1A\".\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal board variants accept the IS220PTURH1B module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe high-density d-sub plug interface on the backplate of the IS220PTURH1B mates natively with standard GE turbine terminal boards, including the TTURH1A, TTURH1B, and TTURH1C functional safety board models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this specific module manage proportional servo valve positioning loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IS220PTURH1B focuses strictly on speed tracking, shaft voltage detection, and system synchronization tasks. To drive hydraulic actuator servo valves, you must pair this module with a dedicated valve positioning pack, such as the GE IS220PSVOH1A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this pack support hot-swapping under live control room scenarios?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In dual or Triple Modular Redundant (TMR) turbine protection panels, you can hot-swap a faulted IS220PTURH1B module without interrupting active operations or cutting power to adjacent running processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53477081219256,"sku":"IS220PTURH1B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS220PTURH1B_2.jpg?v=1779085077"},{"product_id":"mark-vie-speedtronic-turbine-input-i-o-pack-is220pturh1a-ge","title":"Mark VIe Speedtronic Turbine Input I\/O Pack IS220PTURH1A | GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS220PTURH1A operates as a highly specialized, processor-driven turbine input functional I\/O pack within the General Electric Mark VIe Speedtronic control pipeline. This intelligent module interfaces directly with primary turbine primary sensors to monitor critical operation baselines including shaft rotation speed, generator stator voltage, bus voltage, and synchronization parameters. It mounts onto dedicated turbine terminal boards (such as the TTUR card variations) to capture passive pulse counts and high-voltage sinusoids, digitizing these critical parameters directly at the panel layer. By feeding this structural tracking data over dual redundant industrial Ethernet IONet paths, the pack facilitates instant governor adjustments, automated generator synchronization sequencing, and immediate overspeed protection integration.\u003c\/p\u003e\n\u003cp\u003eWe distribute this high-availability critical component exclusively as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee clean electronic internal pathways and flawless structural execution inside your turbomachinery control panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS220PTURH1A integrates a high-speed internal microcontroller, dual network transceiver links, specialized speed input processing chips, and an internal synchronization check matrix within a ruggedized protective metal casing. The table below outlines the core electrical, sensory, and environmental operational parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220PTURH1A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Framework\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe Speedtronic Turbine Control System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Group\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePTUR (Turbine Input Input\/Output Pack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Revision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH1A (Designates high-speed computing core with full conformal insulation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 10\/100 Base-TX RJ-45 copper Ethernet ports for redundant IONet loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Sensor Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels (Accepts magnetic pickup sensors and active pulse encoders)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Frequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Hz to 20,000 Hz tracking capability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Channels for Generator Stator \/ 2 Channels for Utility System Bus monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Reading Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 150 V RMS nominal AC voltage input spans\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Sampling Matrix\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous 16-bit high-resolution voltage tracking loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 V DC nominal (Accepts 18.5 V DC to 32.0 V DC operating boundary)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Shield\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull surface-mount component conformal coating formulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Automatic Synchronization Checking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pack houses an onboard dedicated phase-matching logic chip that samples generator and bus voltage waveforms concurrently. It calculates slip frequency, phase angle variance, and voltage differentials locally, providing safe interlock verification for automated breaker closure commands to shield the generator stator from massive torque shocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Low Frequency Speed Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced zero-crossing detection circuits allow the module to read low-amplitude magnetic pickup signals down to 2 Hz. This extreme sensitivity allows the turbine controller to track shaft speed during initial steam warming rotations or turning-gear cycles, eliminating blind spots in the low-RPM operating envelope.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant IONet Communication Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware utilizes two independent RJ-45 Ethernet transceivers to stream turbine speed variables across separate physical network infrastructures. If an external switch drops or an individual network drop wire breaks, the parallel port maintains active real-time data throughput to prevent unexpected turbine failsafe trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Terminal Standoff Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe structural casing includes built-in securing bolts that thread directly into terminal board standoffs. This rigid mechanical layout eliminates loose component vibration, guarantees perfect alignment for the 37-pin interface pins, and removes the need for custom backplate bracket drilling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the IS220PTURH1A to build primary overspeed trip protection loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes. When you configure three IS220PTURH1A packs across a Triple Modular Redundant (TMR) TTUR terminal board, the system builds a 2-out-of-3 (2oo3) hardware voting architecture. This setup provides instantaneous independent overspeed trip command deployment directly to the emergency trip fluid solenoids if the rotor exceeds maximum safety limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the module handle active proximity-type speed sensors alongside passive magnetic pickups?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes. The board interfaces with both passive 2-wire magnetic pickup sensors (MPUs) and active 3-wire eddy-current proximity gear encoders. The module provides internal jump configuration routes to supply the required DC bias voltages for active sensors without necessitating auxiliary power injection blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What specific advantage does the 'H1A' revision supply over older turbine terminal cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The \"H1A\" designation represents a standalone architecture block that handles memory scrubbing, signal digitization, and networking protocols directly inside the pack housing. This removes vulnerable multi-core ribbon cables used in legacy Mark VI control formats, sealing the sensitive parallel signal conversion loop behind ruggedized metal shielding to completely repel high-voltage cabinet electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53481931767992,"sku":"IS220PTURH1A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS220PTURH1A_2_1.jpg?v=1779178946"},{"product_id":"ge-turbine-primary-trip-board-is200vturh2bab","title":"GE Turbine Primary Trip Board IS200VTURH2BAB","description":"\u003cp\u003eConfigured for high-speed shaft speed processing in the Mark VI Speedtronic control network, the \u003cstrong\u003eGE IS200VTURH2BAB\u003c\/strong\u003e (base model \u003cstrong\u003eIS200VTUR\u003c\/strong\u003e) provides direct physical execution of turbine overspeed protection logic and magnetic pickup signal conversion. It interfaces with emergency trip boards via hard-wired relay contacts and transmits processed speed data to the control backplane without external supervisory intervention.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDefinition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200\u003c\/td\u003e\n\u003ctd\u003eGE Industrial Systems Speedtronic base identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVTUR\u003c\/td\u003e\n\u003ctd\u003eTurbine Primary Trip \/ Speed Input functional type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2\u003c\/td\u003e\n\u003ctd\u003eHardware revision level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBAB\u003c\/td\u003e\n\u003ctd\u003eArtwork, assembly, and firmware version identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eGE Industrial Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VI PCB form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15 W typical from backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003eMagnetic pickup sine wave, 10 mVpp to 120 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eForm-A dry contact relays, analog speed signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eIn TMR-configured Mark VI racks, firmware revisions must be identical across all three VTUR modules to prevent checksum mismatch during cross-channel voting. Flash updates require offline loading via GE ToolboxST software, and mismatched firmware may result in forced trip state on rack initialization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200VTURH2BAB be hot-swapped in an active Mark VI rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Backplane power must be removed prior to removal or insertion to prevent relay contact arcing and backplane bus corruption.\u003c\/p\u003e\n\u003cp\u003eQ: Does the H2 hardware revision alter input scaling compared to earlier versions?\u003c\/p\u003e\n\u003cp\u003eA: No. Input scaling remains consistent; changes are limited to component sourcing and PCB artwork. Firmware compatibility remains the determining factor.\u003c\/p\u003e\n\u003cp\u003eQ: What is the expected relay life cycle under continuous duty?\u003c\/p\u003e\n\u003cp\u003eA: Mechanical relay service life exceeds 100,000 operations at rated load; however, high-cycle applications should implement external solid-state interposing relays.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount securely into the Mark VI rack using the injector\/ejector handle until fully seated. Ensure all I\/O cabling uses individually shielded twisted pair wiring with shield drain wires terminated to rack ground at one end only. Maintain minimum 50 mm separation between speed signal cables and high-power AC wiring to prevent inductive interference. Verify magnetic pickup air gap per turbine OEM specification before energizing the module.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53601505345720,"sku":"IS200VTURH2BAB","price":1741.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200VTURH2BAB-3.jpg?v=1781752180"},{"product_id":"ge-multilin-ur6hh-ur-6hh-direct-i-o-module","title":"GE Multilin UR6HH UR 6HH Direct I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6HH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003e6 Form-A outputs\u003c\/strong\u003e (no monitoring) and \u003cstrong\u003e4 digital contact inputs\u003c\/strong\u003e, enabling the relay to connect to various devices in the operating system such as selector switches, pushbuttons, limit switches, fans, lights, and valves.\u003c\/p\u003e\n\n\u003cp\u003eThe UR-6HH supports both \u003cstrong\u003ewet and dry contact\u003c\/strong\u003e types. Dry contacts provide isolation between devices, while wet contacts do not. The module is fully compatible with \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software for streamlined configuration and diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e6 × Form-A outputs\u003c\/strong\u003e (normally open, no monitoring) for direct control applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Digital contact inputs\u003c\/strong\u003e for external signal monitoring\u003c\/li\u003e\n  \u003cli\u003eSupports both \u003cstrong\u003ewet and dry contact\u003c\/strong\u003e types\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexLogic™ programmable logic\u003c\/strong\u003e support for custom protection schemes\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 6H)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 contact inputs\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e6 × Form-A\u003c\/strong\u003e (NO, no monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eContact Types\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWet or Dry contacts supported\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e1.15 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial automation\u003c\/strong\u003e — process control systems and building management\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower generation\u003c\/strong\u003e — monitoring and control of auxiliary equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and gas\u003c\/strong\u003e — data acquisition and equipment control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and wastewater\u003c\/strong\u003e — pump and valve control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — status monitoring and interlocking logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-6HH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. Modules can be mixed within the same chassis for scalable system upgrades. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-6HH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Observe correct polarity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"6H\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: In the UR series order code structure, \"6H\" designates this specific digital I\/O module configuration: \u003cstrong\u003e6 Form-A outputs + 4 digital inputs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between wet and dry contacts?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eDry contacts\u003c\/strong\u003e are passive contacts that provide isolation between devices. \u003cstrong\u003eWet contacts\u003c\/strong\u003e are active contacts that do not provide the same isolation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use UR-6HH for breaker tripping?\u003c\/strong\u003e\u003cbr\u003e\nA: The Form-A outputs can be used for control applications. For high-current tripping, verify contact ratings or consider trip-rated modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-6HH\u003c\/strong\u003e when you need \u003cstrong\u003e6 Form-A outputs with 4 inputs\u003c\/strong\u003e for general-purpose control.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-A outputs with current monitoring\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eall Form-C outputs\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-6HH \/ UR6HH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 6 Form-A Outputs + 4 Contact Inputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759514706104,"sku":"UR6EV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6HH.png?v=1783925622"},{"product_id":"ge-multilin-ur-series-ur9ah-ur-9ah-cpu-module","title":"GE Multilin UR Series UR9AH UR-9AH CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-9AH\u003c\/strong\u003e is a \u003cstrong\u003eCPU Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides the relay with computing power through logic algorithms, logic gates, timers, and latches essential for protection and control functions. The UR-9AH features \u003cstrong\u003eRS485\u003c\/strong\u003e communication and \u003cstrong\u003etriple Ethernet ports\u003c\/strong\u003e for high-speed LAN connectivity, reducing latency in demanding substation automation applications.\u003c\/p\u003e\n\n\u003cp\u003eThe UR-9AH supports \u003cstrong\u003eIEC 61850 Ed. 1 and Ed. 2\u003c\/strong\u003e compliance, \u003cstrong\u003eRoutable GOOSE (R-GOOSE)\u003c\/strong\u003e for wide-area protection, and \u003cstrong\u003eCyberSentry UR\u003c\/strong\u003e for robust network security. It also includes \u003cstrong\u003ePhasor Measurement Unit (PMU)\u003c\/strong\u003e capabilities per IEEE C37.118 and IEC 61850-90-5 standards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS485 port\u003c\/strong\u003e supporting Modbus RTU and DNP communication protocols\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThree Ethernet ports\u003c\/strong\u003e for specific LAN support with reduced latency\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoutable GOOSE (R-GOOSE)\u003c\/strong\u003e enabling protective messages beyond the substation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61850 Ed. 1 and Ed. 2\u003c\/strong\u003e certified implementation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCyberSentry UR\u003c\/strong\u003e cybersecurity aligned with NERC CIP standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhasor Measurement Unit (PMU)\u003c\/strong\u003e per IEEE C37.118 and IEC 61850-90-5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull-color display\u003c\/strong\u003e for real-time visualization and phasor graphical display\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e with common hardware platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCPU Module (Order Code: 9A)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication Interfaces\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003eRS485\u003c\/strong\u003e + \u003cstrong\u003e3 × Ethernet ports\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported Protocols\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModbus RTU\/TCP, DNP3, IEC 61850\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCybersecurity\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003eCyberSentry™ UR\u003c\/strong\u003e (NERC CIP aligned)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTime Synchronization\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIEEE 1588, SNTP\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePMU Support\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIEEE C37.118, IEC 61850-90-5\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e0.8 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eGenerator, transformer, and feeder protection\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eTransmission line and distribution protection\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCapacitor bank and network stability control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eMotor protection, monitoring, metering, and control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eUtility substation and industrial plant automation\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Area Protection and Control (WAPC)\u003c\/strong\u003e via R-GOOSE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-9AH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It is best paired with \u003cstrong\u003enewer CT\/VT modules\u003c\/strong\u003e to avoid hardware mismatch errors. Always ensure firmware compatibility when upgrading.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the CPU module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the CPU slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-9AH into the designated CPU slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software. The CPU automatically reads configuration data from each module.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"9A\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"9A\" designates a CPU module with \u003cstrong\u003eRS485 + triple Ethernet\u003c\/strong\u003e communication capabilities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is R-GOOSE and why is it important?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eRoutable GOOSE (R-GOOSE)\u003c\/strong\u003e allows protective GOOSE messages to travel beyond the local substation LAN over WAN networks, enabling cost-effective Wide Area Protection without dedicated communication channels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-9AH compatible with older CT\/VT modules?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-9AH is best used with \u003cstrong\u003enewer CT\/VT modules\u003c\/strong\u003e. Pairing with old CT\/VT modules may result in hardware mismatch errors. Always verify compatibility in the UR manual.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What cybersecurity features are included?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eCyberSentry UR\u003c\/strong\u003e provides role-based access control, password policies, audit logs, IEC 62351-compliant encryption, and secure management ports.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-9AH\u003c\/strong\u003e when you need \u003cstrong\u003eRS485 + triple Ethernet\u003c\/strong\u003e with IEC 61850 and R-GOOSE support.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eRS485 + 10\/100Base-T Ethernet\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-9NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003efiber optic Ethernet\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-9GH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways verify \u003cstrong\u003eCT\/VT module compatibility\u003c\/strong\u003e when selecting a CPU module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-9AH \/ UR9AH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series CPU Module — RS485 + 3× Ethernet, IEC 61850, R-GOOSE\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759520997560,"sku":"UR9AH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR9NH_3r180.png?v=1783925590"},{"product_id":"ge-multilin-ur-series-ur-9ev-cpu-processor-module","title":"GE Multilin UR Series UR 9EV CPU Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-9EV\u003c\/strong\u003e is a \u003cstrong\u003eCPU Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. Powered by a \u003cstrong\u003edual-core ARM Cortex-A9 processor\u003c\/strong\u003e, this module delivers high-performance computing for complex protection, control, and automation applications. The UR-9EV features \u003cstrong\u003eRS485\u003c\/strong\u003e and \u003cstrong\u003eEthernet\u003c\/strong\u003e communication interfaces, supporting multiple industrial protocols for seamless SCADA and DCS integration.\u003c\/p\u003e\n\n\u003cp\u003eThe module includes advanced protection algorithms for power transformers, generators, and motors, along with integrated monitoring and metering capabilities. It is fully compatible with \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software for configuration, diagnostics, and firmware management.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-core ARM Cortex-A9 processor\u003c\/strong\u003e for high-performance computing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1 GB DDR3 SDRAM\u003c\/strong\u003e for fast data processing and storage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS485 and Ethernet\u003c\/strong\u003e communication interfaces\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple protocol support:\u003c\/strong\u003e DNP3, Modbus, IEC 61850, SEL 334\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced protection algorithms\u003c\/strong\u003e for transformers, generators, and motors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated monitoring and metering\u003c\/strong\u003e capabilities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible and expandable I\/O\u003c\/strong\u003e configurations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCybersecurity features\u003c\/strong\u003e including encryption and authentication\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCPU Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDual-core ARM Cortex-A9\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMemory\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e1 GB DDR3 SDRAM\u003c\/strong\u003e (varies by configuration)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication Interfaces\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRS485, Ethernet, optional fiber optics\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported Protocols\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDNP3, Modbus RTU\/TCP, IEC 61850, SEL 334\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e24 VDC nominal\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +85 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e0.74 – 0.84 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCertifications\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUL, CE, IEC, RoHS\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003ePower transformer protection and control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eGenerator protection and management\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eMotor protection schemes\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCircuit breaker and feeder control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eSubstation automation and SCADA integration\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eIndustrial power system monitoring\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-9EV is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It can accommodate up to \u003cstrong\u003e24 I\/O modules\u003c\/strong\u003e including CT\/VT, digital, and analog cards, providing scalable architectures for diverse protection applications.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the CPU module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the CPU slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-9EV into the designated CPU slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What processor does the UR-9EV use?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-9EV features a \u003cstrong\u003edual-core ARM Cortex-A9 processor\u003c\/strong\u003e with \u003cstrong\u003e1 GB DDR3 SDRAM\u003c\/strong\u003e for high-performance computing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-9EV supports \u003cstrong\u003eDNP3, Modbus RTU\/TCP, IEC 61850, and SEL 334\u003c\/strong\u003e protocols.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-9EV suitable for extreme environments?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, it operates reliably from \u003cstrong\u003e–40 °C to +85 °C\u003c\/strong\u003e, making it suitable for harsh industrial environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What software is required for configuration?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e is the official GE software for configuring all UR series modules.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-9EV\u003c\/strong\u003e when you need a \u003cstrong\u003edual-core ARM CPU\u003c\/strong\u003e with multiple protocol support for complex protection schemes.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eRS485 + triple Ethernet\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-9AH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003efiber optic + RS485\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-9GH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways verify \u003cstrong\u003eI\/O module compatibility\u003c\/strong\u003e when selecting a CPU module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-9EV \/ UR9EV\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series CPU Module — Dual-core ARM Cortex-A9, RS485 + Ethernet\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759524929720,"sku":"UR9EV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR9NH_3r180.png?v=1783925590"},{"product_id":"ge-multilin-ur-series-ct-vt-ur8ah-ur-8ah-processor-module","title":"GE Multilin UR Series CT\/VT UR8AH UR 8AH Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-8AH\u003c\/strong\u003e is a \u003cstrong\u003eCT\/VT Module\u003c\/strong\u003e (Current Transformer \/ Voltage Transformer) from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module scales down the voltage and current values of the power system to manageable levels for the Universal Relay, ensuring precise measurement and protection. It provides \u003cstrong\u003ethree 1A\/5A Phase CTs\u003c\/strong\u003e, \u003cstrong\u003e1A\/5A Ground CTs\u003c\/strong\u003e, and \u003cstrong\u003efour Voltage Transformers (VTs)\u003c\/strong\u003e for comprehensive power system monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe UR-8AH is best used with \u003cstrong\u003eolder UR CPUs\u003c\/strong\u003e such as the UR-9A, UR-9C, or UR-9D, and requires \u003cstrong\u003efirmware version 3.5x or earlier\u003c\/strong\u003e for compatibility. The module features secondary winding grounding for enhanced operator safety and supports configuration via \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3 × Phase CTs\u003c\/strong\u003e (1A\/5A) for current monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1 × Ground CT\u003c\/strong\u003e (1A\/5A) for ground fault detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Voltage Transformers (VTs)\u003c\/strong\u003e for voltage measurement and scaling\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecondary winding grounded\u003c\/strong\u003e for enhanced operator safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault detection capability\u003c\/strong\u003e to identify unsafe system conditions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable CT and VT settings\u003c\/strong\u003e via EnerVista UR software\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData trending and export\u003c\/strong\u003e for system analysis\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard 4CT\/4VT configuration\u003c\/strong\u003e for versatile protection schemes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCT\/VT Module (Order Code: 8A)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePhase CTs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e3 × 1A\/5A\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGround CTs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 × 1A\/5A\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVoltage Transformers (VTs)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 VTs\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSystem Compatibility\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR-9A, UR-9C, UR-9D CPUs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFirmware Compatibility\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVersion \u003cstrong\u003e3.5x or earlier\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e15 cm (L) × 18 cm (W) × 4 cm (H)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e1.15 kg\u003c\/strong\u003e (2 lb 9 oz)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower system protection\u003c\/strong\u003e — overcurrent, differential, and distance protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransformer protection\u003c\/strong\u003e — current and voltage monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenerator protection\u003c\/strong\u003e — phase and ground fault detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeeder protection\u003c\/strong\u003e — load monitoring and fault identification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — SCADA integration and data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-8AH is compatible with \u003cstrong\u003eolder UR CPU modules\u003c\/strong\u003e (UR-9A, UR-9C, UR-9D) running \u003cstrong\u003efirmware 3.5x or earlier\u003c\/strong\u003e. For newer CPU modules, consider upgraded CT\/VT modules with enhanced diagnostics. Always pair new CT\/VT modules with new CPUs to avoid hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the CT\/VT slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-8AH into the designated slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect CT and VT secondary wiring per the UR series wiring diagram. \u003cstrong\u003eEnsure secondary windings are properly grounded.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure CT\/VT ratios and settings via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"8A\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"8A\" designates a \u003cstrong\u003estandard CT\/VT module\u003c\/strong\u003e with 4 CT and 4 VT inputs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-8AH compatible with newer UR CPUs?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-8AH is designed for \u003cstrong\u003eolder CPUs\u003c\/strong\u003e (UR-9A, UR-9C, UR-9D) with \u003cstrong\u003efirmware 3.5x or earlier\u003c\/strong\u003e. For newer systems, consider CT\/VT modules with enhanced diagnostics.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Why is secondary winding grounding important?\u003c\/strong\u003e\u003cbr\u003e\nA: Grounding the secondary winding of CTs and VTs is a \u003cstrong\u003esafety requirement\u003c\/strong\u003e that protects operators from high voltage and prevents equipment damage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of CT\/VT modules per chassis?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR platform allows a \u003cstrong\u003emaximum of 3 CT\/VT modules\u003c\/strong\u003e per chassis, supporting up to 6 sets of three-phase voltages and currents.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-8AH\u003c\/strong\u003e for \u003cstrong\u003estandard 4CT\/4VT\u003c\/strong\u003e applications with older UR CPUs.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eenhanced diagnostics\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-8LH\u003c\/strong\u003e or \u003cstrong\u003eUR-8NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003esensitive ground fault protection\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-8G, UR-8J, UR-8M, or UR-8R\u003c\/strong\u003e modules.\u003c\/li\u003e\n  \u003cli\u003eAlways verify \u003cstrong\u003eCPU and firmware compatibility\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-8AH \/ UR8AH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series CT\/VT Module — 4CT\/4VT, 1A\/5A, Standard\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759531614392,"sku":"UR8AH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR8BV_2.png?v=1783925586"},{"product_id":"ursha-ge-multilin-ur-series-power-supply-module","title":"URSHA | GE Multilin UR Series Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-SHA\u003c\/strong\u003e is a \u003cstrong\u003ethird-generation Power Supply Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This high-power module delivers a nominal power rating of \u003cstrong\u003e125 to 250 V\u003c\/strong\u003e (AC\/DC), making it ideal for demanding substation and industrial power applications. The UR-SHA replaces the first-generation \u003cstrong\u003eUR-1H\u003c\/strong\u003e and second-generation \u003cstrong\u003eUR-RH\u003c\/strong\u003e power supply modules with significantly improved performance and reliability.\u003c\/p\u003e\n\n\u003cp\u003eThe UR-SHA provides \u003cstrong\u003e48 V DC power\u003c\/strong\u003e to dry contact input connections and features \u003cstrong\u003ebuilt-in diagnostics\u003c\/strong\u003e with LED indicators on the faceplate for real-time operational status monitoring. It includes \u003cstrong\u003eovertemperature protection\u003c\/strong\u003e that shuts off the module at 105°C, ensuring safe operation in harsh environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh power output:\u003c\/strong\u003e 45W (upgraded from 35W in previous generations)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide input voltage range:\u003c\/strong\u003e 125–250 V nominal (AC\/DC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e48 V DC dry contact input power\u003c\/strong\u003e supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e28% improved efficiency\u003c\/strong\u003e over previous generations with minimized heat emission\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 2300 V AC (upgraded from 2000 V AC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvertemperature protection\u003c\/strong\u003e with automatic shutoff at 105°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-in diagnostics\u003c\/strong\u003e for hardware health monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED faceplate indicators\u003c\/strong\u003e for power status and fault detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReplaces UR-1H (1st gen) and UR-RH (2nd gen)\u003c\/strong\u003e power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Supply Module (3rd Generation)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Voltage Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e125–250 V\u003c\/strong\u003e nominal (AC\/DC)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Output\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e45 W\u003c\/strong\u003e (upgraded from 35 W)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDry Contact Input Power\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e48 V DC\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIsolation Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e2300 V AC\u003c\/strong\u003e (upgraded from 2000 V AC)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eEfficiency Improvement\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e28%\u003c\/strong\u003e over previous generations\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOvertemperature Protection\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAutomatic shutoff at \u003cstrong\u003e105°C\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDiagnostic Features\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eBuilt-in hardware health monitoring with LED indicators\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eHorizontal 19\" rack with harsh environmental coating\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e6.5\" L × 6.5\" W × 1.75\" H (16.5 × 16.5 × 4.5 cm)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e0.95 – 0.96 kg\u003c\/strong\u003e (2 lb 2 oz)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — reliable power for protection relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower generation\u003c\/strong\u003e — generator and transformer protection systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransmission and distribution\u003c\/strong\u003e — feeder and line protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial power systems\u003c\/strong\u003e — motor and breaker control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHarsh environment installations\u003c\/strong\u003e — with harsh environmental coating\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-SHA is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It is designed to replace the \u003cstrong\u003eUR-1H (1st generation)\u003c\/strong\u003e and \u003cstrong\u003eUR-RH (2nd generation)\u003c\/strong\u003e power supply modules. The \"A\" suffix indicates a \u003cstrong\u003ehorizontal 19-inch rack\u003c\/strong\u003e with harsh environmental coating.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the power supply slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-SHA into the designated power supply slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect input power and dry contact wiring per the UR series wiring diagram.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Power on and verify LED indicators show successful operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the UR-SHA different from previous generations?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-SHA is the \u003cstrong\u003e3rd generation\u003c\/strong\u003e power supply with \u003cstrong\u003e45W output\u003c\/strong\u003e (vs. 35W), \u003cstrong\u003e28% improved efficiency\u003c\/strong\u003e, \u003cstrong\u003e2300 V AC isolation\u003c\/strong\u003e (vs. 2000 V AC), and \u003cstrong\u003eovertemperature protection at 105°C\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"A\" suffix mean in UR-SHA?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"A\" indicates a \u003cstrong\u003ehorizontal 19-inch rack mount\u003c\/strong\u003e with harsh environmental coating. \"B\" would indicate a vertical 3\/4 size mount.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What voltage does the UR-SHA provide for dry contacts?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-SHA provides \u003cstrong\u003e48 V DC\u003c\/strong\u003e power for dry contact input connections.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-SHA compatible with all UR relays?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the UR-SHA is compatible with all \u003cstrong\u003eUR Series Universal Relays\u003c\/strong\u003e. It replaces both UR-1H and UR-RH modules.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-SHA\u003c\/strong\u003e for \u003cstrong\u003ehigh-voltage applications\u003c\/strong\u003e (125–250 V AC\/DC) requiring 45W output.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003elow-voltage applications\u003c\/strong\u003e (24–48 V DC), consider the \u003cstrong\u003eUR-SHB\u003c\/strong\u003e or other low-range power supplies.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eredundant power\u003c\/strong\u003e, verify if your relay chassis supports dual power supply configurations.\u003c\/li\u003e\n  \u003cli\u003eAlways verify \u003cstrong\u003einput voltage requirements\u003c\/strong\u003e match your substation power standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-SHA \/ URSHA\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Power Supply Module — 125-250V, 45W, Horizontal 19\" Rack\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759535775928,"sku":"URSHA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6EV.png?v=1783925591"},{"product_id":"ge-multilin-ur-series-ur9nh-cpu-module","title":"GE Multilin UR Series UR9NH CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-9NH\u003c\/strong\u003e is a \u003cstrong\u003eCPU Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module features a \u003cstrong\u003ehigh-performance 32-bit processor\u003c\/strong\u003e with \u003cstrong\u003eRS485\u003c\/strong\u003e and \u003cstrong\u003e10\/100Base-T Ethernet\u003c\/strong\u003e communication interfaces, making it suitable for a wide range of protection and control applications. The UR-9NH is designated by the \u003cstrong\u003eorder code \"9N\"\u003c\/strong\u003e, representing a newer CPU design in the UR family.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant Note:\u003c\/strong\u003e GE Grid Solutions has discontinued the manufacture of \u003cstrong\u003eUR Version 6 CPU modules\u003c\/strong\u003e (including order codes E, J, K, and N) as of \u003cstrong\u003eDecember 31, 2022\u003c\/strong\u003e. The UR-9NH has been superseded by \u003cstrong\u003eVersion 7 CPU modules\u003c\/strong\u003e (UR9T, UR9U, UR9V, UR9W). Please verify availability and consider upgrade paths when ordering.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-performance 32-bit CPU\u003c\/strong\u003e for complex protection algorithms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS485 port\u003c\/strong\u003e for serial communication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10\/100Base-T Ethernet port\u003c\/strong\u003e for high-speed network connectivity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple protocol support:\u003c\/strong\u003e Modbus RTU\/TCP, DNP3, IEC 61850\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide input voltage range:\u003c\/strong\u003e 24\/48\/110\/125 VDC or 120\/240 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug \u0026amp; Play functionality\u003c\/strong\u003e for simplified installation\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eGround surge connection not required\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCPU Module (Order Code: 9N) — Version 6\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eHigh-performance 32-bit CPU\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication Interfaces\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003eRS485\u003c\/strong\u003e + \u003cstrong\u003e10\/100Base-T Ethernet\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported Protocols\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModbus RTU\/TCP, DNP3, IEC 61850\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e24\/48\/110\/125 VDC\u003c\/strong\u003e or \u003cstrong\u003e120\/240 VAC\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e0.8 – 0.86 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStatus\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003eDiscontinued\u003c\/strong\u003e (Dec 31, 2022) — replaced by Version 7 CPUs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eGenerator protection and management\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eTransformer protection schemes\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eLine differential and feeder protection\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eMotor protection and control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eSubstation automation and SCADA integration\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eIndustrial power system protection\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-9NH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. As a \u003cstrong\u003eVersion 6 CPU\u003c\/strong\u003e, it must be paired with \u003cstrong\u003enewer CT\/VT modules\u003c\/strong\u003e to avoid hardware mismatch errors. For new installations, GE recommends \u003cstrong\u003eVersion 7 CPU modules\u003c\/strong\u003e (UR9T, UR9U, UR9V, UR9W) with firmware 7.28 or higher.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the CPU module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the CPU slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-9NH into the designated CPU slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software. The CPU automatically reads configuration data from each module.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"9N\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"9N\" designates a \u003cstrong\u003eVersion 6 CPU module\u003c\/strong\u003e with \u003cstrong\u003eRS485 + 10\/100Base-T Ethernet\u003c\/strong\u003e communication capabilities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-9NH still available for purchase?\u003c\/strong\u003e\u003cbr\u003e\nA: GE \u003cstrong\u003ediscontinued Version 6 CPUs on December 31, 2022\u003c\/strong\u003e. Limited stock may be available through distributors. For new systems, consider \u003cstrong\u003eVersion 7 CPUs\u003c\/strong\u003e (UR9T, UR9U, UR9V, UR9W).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What are the replacement options for UR-9NH?\u003c\/strong\u003e\u003cbr\u003e\nA: GE recommends \u003cstrong\u003eVersion 7 CPU modules\u003c\/strong\u003e as replacements. Refer to the GE Grid Solutions website for specific cross-reference information.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-9NH compatible with older CT\/VT modules?\u003c\/strong\u003e\u003cbr\u003e\nA: No. The UR-9NH must be paired with \u003cstrong\u003enewer CT\/VT modules\u003c\/strong\u003e. Pairing with old CT\/VT modules will result in hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n \u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759538561208,"sku":"UR9NH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR9NH.png?v=1783925582"},{"product_id":"ge-multilin-ur-series-ur6th-digital-i-o-module","title":"GE Multilin UR Series UR6TH Digital I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6TH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003e6 Form-A outputs\u003c\/strong\u003e (no monitoring) and \u003cstrong\u003e4 digital contact inputs\u003c\/strong\u003e, enabling the relay to connect to various devices in the operating system such as selector switches, pushbuttons, limit switches, fans, lights, and valves. The UR-6TH supports both \u003cstrong\u003ewet and dry contact\u003c\/strong\u003e types, providing flexibility for diverse industrial applications.\u003c\/p\u003e\n\n\u003cp\u003eThe module features a \u003cstrong\u003emodular plug-and-play design\u003c\/strong\u003e for easy installation and system upgrades. It is fully compatible with \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software for streamlined configuration and diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e6 × Form-A outputs\u003c\/strong\u003e (normally open, no monitoring) for direct control applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Digital contact inputs\u003c\/strong\u003e for external signal monitoring\u003c\/li\u003e\n  \u003cli\u003eSupports both \u003cstrong\u003ewet and dry contact\u003c\/strong\u003e types\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexLogic™ programmable logic\u003c\/strong\u003e support for custom protection schemes\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 6T)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 contact inputs\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e6 × Form-A\u003c\/strong\u003e (NO, no monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eContact Types\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWet or Dry contacts supported\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e1.15 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial automation\u003c\/strong\u003e — process control systems and building management\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower generation\u003c\/strong\u003e — monitoring and control of auxiliary equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and gas\u003c\/strong\u003e — data acquisition and equipment control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and wastewater\u003c\/strong\u003e — pump and valve control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — status monitoring and interlocking logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-6TH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. Modules can be mixed within the same chassis for scalable system upgrades. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-6TH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Observe correct polarity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"6T\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: In the UR series order code structure, \"6T\" designates this specific digital I\/O module configuration: \u003cstrong\u003e6 Form-A outputs + 4 digital inputs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between wet and dry contacts?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eDry contacts\u003c\/strong\u003e are passive contacts that provide isolation between devices. \u003cstrong\u003eWet contacts\u003c\/strong\u003e are active contacts that do not provide the same isolation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use UR-6TH for breaker tripping?\u003c\/strong\u003e\u003cbr\u003e\nA: The Form-A outputs can be used for control applications. For high-current tripping, verify contact ratings or consider trip-rated modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-6TH\u003c\/strong\u003e when you need \u003cstrong\u003e6 Form-A outputs with 4 inputs\u003c\/strong\u003e for general-purpose control.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-A outputs with current monitoring\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eall Form-C outputs\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-6TH \/ UR6TH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 6 Form-A Outputs + 4 Contact Inputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759541117112,"sku":"UR6TH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6TH_2.png?v=1783925599"},{"product_id":"ur5fh-ge-multilin-ur-series-ur-5fh-transducer-i-o-5f-module","title":"UR5FH | GE Multilin UR Series UR 5FH Transducer I\/O 5F Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-5FH\u003c\/strong\u003e is a \u003cstrong\u003eTransducer I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module enables signal conversion from \u003cstrong\u003e–1 to +20 mA DC\u003c\/strong\u003e into digital format, allowing the relay to display scaled, real-time parameters. The UR-5FH is used to monitor system parameters such as \u003cstrong\u003etemperature, vibration, pressure, wind speed, and flow\u003c\/strong\u003e by converting analog transducer signals into digital data that the UR relay can process and display.\u003c\/p\u003e\n\n\u003cp\u003eThe module's I\/O functions — including \u003cstrong\u003eDCmA, RTD, and RRTD inputs\/outputs\u003c\/strong\u003e — are configurable via the relay's keypad and LCD interface or through \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software. The UR-5FH is an essential component for applications requiring analog signal integration into digital protection and control systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDCmA input\/output\u003c\/strong\u003e conversion: –1 to +20 mA DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRTD (Resistance Temperature Detector)\u003c\/strong\u003e input support for temperature monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRRTD (Remote RTD)\u003c\/strong\u003e input capability for distributed temperature sensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalog output\u003c\/strong\u003e for hardened connections to SCADA, PLC, or HMI devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable I\/O functions\u003c\/strong\u003e via keypad\/LCD or EnerVista UR software\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and upgrades\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTransducer I\/O Module (Order Code: 5F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDCmA Input Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–1 to +20 mA DC\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRTD Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported (temperature monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRRTD Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported (remote temperature sensing)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAnalog Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAvailable for SCADA\/PLC\/HMI integration\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eKeypad\/LCD or \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature monitoring\u003c\/strong\u003e — transformer winding, motor bearing, and generator stator temperatures\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration monitoring\u003c\/strong\u003e — turbine and rotating machinery health assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure monitoring\u003c\/strong\u003e — hydraulic and pneumatic system control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow monitoring\u003c\/strong\u003e — cooling water and lubrication systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWind speed monitoring\u003c\/strong\u003e — wind turbine and environmental sensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA\/PLC integration\u003c\/strong\u003e — analog signal conversion for centralized monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-5FH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It integrates seamlessly with other UR modules including CPU, CT\/VT, digital I\/O, and communication modules. Always verify firmware compatibility when adding transducer I\/O modules to existing systems.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-5FH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Wiring:\u003c\/strong\u003e Connect RTD, DCmA, and analog output wiring per the UR series wiring diagram.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure transducer scaling and alarm thresholds via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software or the front panel keypad.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"5F\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"5F\" designates a \u003cstrong\u003etransducer I\/O module\u003c\/strong\u003e with DCmA, RTD, and RRTD input\/output capabilities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What types of sensors can be connected to the UR-5FH?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-5FH supports \u003cstrong\u003eRTD temperature sensors, DCmA transducers (4–20 mA), and remote RTD (RRTD)\u003c\/strong\u003e inputs for distributed temperature monitoring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the UR-5FH provide analog outputs to SCADA systems?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The module includes \u003cstrong\u003eanalog outputs\u003c\/strong\u003e that can be hardwired to SCADA, PLC, or HMI devices for remote monitoring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-5FH\u003c\/strong\u003e when you need \u003cstrong\u003eDCmA, RTD, and RRTD transducer I\/O\u003c\/strong\u003e for analog parameter monitoring.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003edigital I\/O only\u003c\/strong\u003e, consider the UR-6 series modules (UR-6CH, UR-6HH, UR-6TH).\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eCT\/VT analog inputs\u003c\/strong\u003e, consider the UR-8 series modules.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-5FH \/ UR5FH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Transducer I\/O Module — DCmA\/RTD\/RRTD Inputs \u0026amp; Outputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759567233208,"sku":"UR5FH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6EV_2.png?v=1783925597"},{"product_id":"ge-multilin-ur-series-ur8bv-ct-vt-module","title":"GE Multilin UR Series UR8BV CT\/VT Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-8BV\u003c\/strong\u003e is a \u003cstrong\u003eCT\/VT Module\u003c\/strong\u003e (Current Transformer \/ Voltage Transformer) from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003eaccurate analog signal acquisition\u003c\/strong\u003e from external CTs and VTs, converting current and voltage inputs into reliable digital data for protection, control, metering, and monitoring in power systems. The UR-8BV features \u003cstrong\u003eenhanced diagnostics\u003c\/strong\u003e to detect internal failures and block tripping, ensuring system integrity.\u003c\/p\u003e\n\n\u003cp\u003eThe module supports \u003cstrong\u003e3-phase current and voltage inputs\u003c\/strong\u003e from CTs and VTs, with \u003cstrong\u003eClass 0.2s or 0.5s accuracy\u003c\/strong\u003e depending on configuration. Its compact design and robust construction make it ideal for demanding substation and industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccurate measurement\u003c\/strong\u003e of current and voltage from external CTs and VTs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide input range\u003c\/strong\u003e compatible with various CT and VT configurations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced diagnostics\u003c\/strong\u003e to detect internal failures and block tripping\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClass 0.2s or 0.5s accuracy\u003c\/strong\u003e for high-precision metering\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact design\u003c\/strong\u003e for space-efficient installation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play architecture\u003c\/strong\u003e for easy maintenance and upgrades\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCT\/VT Module (Order Code: 8B)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Signals\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e3-phase current and voltage from CTs and VTs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAccuracy Class\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e0.2s or 0.5s\u003c\/strong\u003e (depending on model)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVaries by model and configuration\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDiagnostics\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eEnhanced — detects internal failures and blocks tripping\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower system protection\u003c\/strong\u003e — overcurrent, differential, and distance protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransformer protection\u003c\/strong\u003e — current and voltage monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenerator protection\u003c\/strong\u003e — phase and ground fault detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor protection\u003c\/strong\u003e — load monitoring and fault identification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — SCADA integration and data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-8BV is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It can replace older CT\/VT units within the UR series and supports scalable upgrades. Always pair new CT\/VT modules with compatible CPU modules to avoid hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the CT\/VT slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-8BV into the designated slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect CT and VT secondary wiring per the UR series wiring diagram. \u003cstrong\u003eEnsure secondary windings are properly grounded.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure CT\/VT ratios and settings via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"8B\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"8B\" designates a \u003cstrong\u003eCT\/VT module\u003c\/strong\u003e with enhanced diagnostics and accurate analog signal acquisition capabilities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What accuracy class does the UR-8BV provide?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-8BV provides \u003cstrong\u003eClass 0.2s or 0.5s accuracy\u003c\/strong\u003e depending on the specific model configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does the enhanced diagnostics feature work?\u003c\/strong\u003e\u003cbr\u003e\nA: The module continuously monitors internal circuitry and can \u003cstrong\u003edetect failures and block tripping\u003c\/strong\u003e to prevent false operations and protect system integrity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-8BV compatible with older UR CPUs?\u003c\/strong\u003e\u003cbr\u003e\nA: Compatibility depends on the CPU firmware version. New CT\/VT modules should be paired with \u003cstrong\u003enewer CPUs\u003c\/strong\u003e to avoid hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-8BV\u003c\/strong\u003e for \u003cstrong\u003ehigh-accuracy CT\/VT signal acquisition\u003c\/strong\u003e with enhanced diagnostics.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003estandard 4CT\/4VT\u003c\/strong\u003e applications, consider the \u003cstrong\u003eUR-8AH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003esensitive ground fault protection\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-8G, UR-8J, UR-8M, or UR-8R\u003c\/strong\u003e modules.\u003c\/li\u003e\n  \u003cli\u003eAlways verify \u003cstrong\u003eCPU and firmware compatibility\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-8BV \/ UR8BV\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series CT\/VT Module — Enhanced Diagnostics, Class 0.2s\/0.5s Accuracy\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759589220536,"sku":"UR8BV","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR8BV_2.png?v=1783925586"},{"product_id":"ur6bh-ge-multilin-ur-series-digital-i-o-6b-card","title":"UR6BH | GE Multilin UR Series |  Digital I\/O 6B Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6BH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This rugged, rack-mounted interface provides \u003cstrong\u003ehigh-density binary sensing and control\u003c\/strong\u003e, bringing powerful digital I\/O capabilities into the UR protection platform. The UR-6BH features \u003cstrong\u003eeight independent Form-A outputs\u003c\/strong\u003e, each rated for \u003cstrong\u003e30 A make and 15 A continuous carry\u003c\/strong\u003e, allowing the module to drive lock-out relays, annunciators, breaker coils, and other high-energy loads without external interposing hardware.\u003c\/p\u003e\n\n\u003cp\u003eEvery output point is \u003cstrong\u003efully isolated, opto-coupled, and surge-tested to 2.5 kV\u003c\/strong\u003e, ensuring that noisy substation environments or fast-rise fault currents cannot corrupt adjacent circuits. Status is reported with \u003cstrong\u003e1 ms time-stamping accuracy\u003c\/strong\u003e via the UR's high-speed internal bus, so event records reflect exactly when a breaker auxiliary contact closed or a trip contact opened.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 × Form-A outputs\u003c\/strong\u003e (normally open) with high current capacity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e30 A make \/ 15 A continuous carry\u003c\/strong\u003e per output — drives high-energy loads directly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFully isolated, opto-coupled outputs\u003c\/strong\u003e with 2.5 kV surge protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1 ms time-stamping accuracy\u003c\/strong\u003e for precise event recording\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFront-facing green\/red LEDs\u003c\/strong\u003e for immediate coil health confirmation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic module recognition\u003c\/strong\u003e by EnerVista UR software\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-swappable construction\u003c\/strong\u003e for expansion or replacement without rebooting\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 6B)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e8 × Form-A\u003c\/strong\u003e (NO, with monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOutput Current Rating\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e30 A make \/ 15 A continuous\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIsolation\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFully isolated, opto-coupled, \u003cstrong\u003e2.5 kV surge-tested\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTime-Stamping Accuracy\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 ms\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStatus Indicators\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eFront-facing green\/red LEDs\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRack-mounted, UR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eBreaker tripping and lock-out relay control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAnnunciator and alarm signaling\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-energy load switching\u003c\/strong\u003e without external interposing relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — status monitoring and control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEvent recording and sequence-of-events (SOE)\u003c\/strong\u003e with 1 ms precision\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-6BH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. The module is automatically detected by \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software, which assigns logic variables and scales de-bounce filters to match the application. Modules can be mixed within the same chassis for scalable system upgrades.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-6BH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect high-current output wiring per the UR series wiring diagram. Use appropriate wire gauge for 30 A make capacity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software. The module is automatically recognized.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"6B\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"6B\" designates a digital I\/O module with \u003cstrong\u003e8 Form-A outputs with monitoring\u003c\/strong\u003e and high current capacity (30 A make \/ 15 A carry).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the UR-6BH drive breaker coils directly?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. With \u003cstrong\u003e30 A make and 15 A continuous carry\u003c\/strong\u003e ratings, the UR-6BH can drive lock-out relays, annunciators, and breaker coils \u003cstrong\u003ewithout external interposing hardware\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the time-stamping accuracy?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-6BH provides \u003cstrong\u003e1 ms time-stamping accuracy\u003c\/strong\u003e via the UR's high-speed internal bus, ensuring precise event records.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-6BH\u003c\/strong\u003e when you need \u003cstrong\u003ehigh-current Form-A outputs\u003c\/strong\u003e (30 A make) for direct breaker tripping and high-energy load control.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003estandard Form-A outputs without monitoring\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6HH\u003c\/strong\u003e or \u003cstrong\u003eUR-6TH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-C outputs\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e or \u003cstrong\u003eUR-6EV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-6BH \/ UR6BH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 8 Form-A Outputs with Monitoring, 30A Make\/15A Carry\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759599182008,"sku":"UR6BH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6BHr180.png?v=1783925601"},{"product_id":"ur6eh-ge-multilin-ur-series-digital-i-o-module","title":"UR6EH | GE Multilin UR Series | Digital I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6EH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003e4 Form-C outputs\u003c\/strong\u003e (SPDT changeover contacts) and \u003cstrong\u003e8 digital inputs\u003c\/strong\u003e, enabling the relay to control and monitor equipment within substations or protective function devices. The UR-6EH is characterized by the \u003cstrong\u003eorder code \"6E\"\u003c\/strong\u003e, which designates this specific I\/O configuration.\u003c\/p\u003e\n\n\u003cp\u003eEach digital I\/O module in the UR series can be differentiated by the type of protection card incorporated into the module. These cards can be classified as \u003cstrong\u003eForm-A, Form-C, SSR (Solid State Relay), or Fast Form-C\u003c\/strong\u003e. The UR-6EH's Form-C outputs provide greater switching flexibility with normally open (NO), normally closed (NC), and common (C) terminals.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Form-C outputs\u003c\/strong\u003e (SPDT changeover contacts) for flexible switching\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 × Digital inputs\u003c\/strong\u003e for external signal monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForm-C contact versatility\u003c\/strong\u003e — NO, NC, and Common terminals per output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and system upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexLogic™ programmable logic\u003c\/strong\u003e support for custom protection schemes\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 6E)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e8 channels\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 × Form-C (SPDT)\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOutput Contact Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eChangeover: NO \/ NC \/ Common\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMaximum Output Current\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e2 A\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e16.3 × 4.2 × 21 cm\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e0.66 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — breaker status monitoring, interlocking, and control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenerator and transformer protection\u003c\/strong\u003e — digital I\/O expansion for trip and alarm signaling\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeeder protection\u003c\/strong\u003e — auxiliary equipment control and status indication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial power systems\u003c\/strong\u003e — control of fans, valves, alarms, and other auxiliary devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA integration\u003c\/strong\u003e — status input and command output interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-6EH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. The module's Form-C outputs provide greater switching flexibility compared to Form-A outputs, making it suitable for applications requiring changeover contacts. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-6EH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Form-C outputs provide NO, NC, and Common terminals for flexible switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"6E\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"6E\" designates a digital I\/O module with \u003cstrong\u003e4 Form-C outputs + 8 digital inputs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between Form-A and Form-C outputs?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eForm-A\u003c\/strong\u003e is a single normally open (NO) contact. \u003cstrong\u003eForm-C\u003c\/strong\u003e is a changeover (SPDT) contact with NO, NC, and Common terminals, providing greater switching flexibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum output current?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-6EH Form-C outputs are rated for \u003cstrong\u003e2 A maximum output current\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-6EH\u003c\/strong\u003e when you need \u003cstrong\u003eForm-C changeover contacts\u003c\/strong\u003e (4 outputs) with 8 digital inputs.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003emore Form-C outputs\u003c\/strong\u003e (6 or 8), consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e or \u003cstrong\u003eUR-6EV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-A outputs with current monitoring\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-6EH \/ UR6EH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 4 Form-C Outputs + 8 Digital Inputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759612616888,"sku":"UR6EH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6EH.png?v=1783925591"},{"product_id":"ge-multilin-ur-series-ur6uh-digital-i-o-module","title":"GE Multilin UR Series UR6UH  Digital I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6UH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003e6 Form-A outputs\u003c\/strong\u003e (no monitoring) and \u003cstrong\u003e4 digital inputs\u003c\/strong\u003e, enabling control and monitoring of auxiliary equipment when installed in a Universal Relay. The UR-6UH features a \u003cstrong\u003eplug-and-play design\u003c\/strong\u003e for easy module exchange and rapid system upgrades.\u003c\/p\u003e\n\n\u003cp\u003eDigital data processing in the UR-6UH is more \u003cstrong\u003ecost-effective\u003c\/strong\u003e than analog alternatives, reducing user burden while generating less electrical noise for smoother system operation. The module is fully compatible with \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software for configuration via software or manual keypad and LCD entry.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e6 × Form-A outputs\u003c\/strong\u003e (no monitoring) for direct control applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Digital inputs\u003c\/strong\u003e for external signal monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug \u0026amp; Play design\u003c\/strong\u003e for easy module exchange and rapid upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital I\/O capabilities\u003c\/strong\u003e eliminate the need for analog inputs\/outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow power consumption\u003c\/strong\u003e for energy-efficient operation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable via EnerVista UR software\u003c\/strong\u003e or front panel keypad\/LCD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged and reliable\u003c\/strong\u003e design for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 6U)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 channels\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e6 × Form-A\u003c\/strong\u003e (NO, no monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e24 VDC to 52 VDC\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e5 W maximum\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +85 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eStorage Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e–55 °C to +90 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eHumidity\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVibration\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e5 g rms, 10 to 500 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eShock\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e15 g, 20 ms half-sine\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e18 × 15 × 4 cm\u003c\/strong\u003e (L × W × H)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e0.5 – 1.15 kg\u003c\/strong\u003e (varies by source)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCertifications\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUL, CSA, CE (IEC 60255-5)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial automation\u003c\/strong\u003e — process control systems, building management, energy management\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower generation\u003c\/strong\u003e — monitoring and control of auxiliary equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and gas\u003c\/strong\u003e — data acquisition and analysis\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and wastewater\u003c\/strong\u003e — pump and valve control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — status monitoring and interlocking logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-6UH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It shares similarities with the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e module in size, weight, power requirements, and communication interfaces. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-6UH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Observe correct polarity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software or front panel keypad\/LCD.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"6U\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"6U\" designates a digital I\/O module with \u003cstrong\u003e6 Form-A outputs (no monitoring) + 4 digital inputs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between UR-6UH and UR-6CH?\u003c\/strong\u003e\u003cbr\u003e\nA: Both modules share similar size, weight, and communication interfaces. The UR-6UH is a \u003cstrong\u003e6U height\u003c\/strong\u003e module, while the UR-6CH may differ in specific output configurations. Always verify the exact I\/O configuration before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What power supply does the UR-6UH require?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-6UH operates on \u003cstrong\u003e24 VDC to 52 VDC\u003c\/strong\u003e with a maximum power consumption of \u003cstrong\u003e5 W\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-6UH\u003c\/strong\u003e when you need \u003cstrong\u003e6 Form-A outputs with 4 inputs\u003c\/strong\u003e in a compact 6U form factor.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-A outputs with current monitoring\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eall Form-C outputs\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e or \u003cstrong\u003eUR-6EV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-6UH \/ UR6UH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 6 Form-A Outputs + 4 Digital Inputs, 6U Height\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759624183992,"sku":"UR6UH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6UH.png?v=1783925608"},{"product_id":"ur8ch-ge-multilin-ur-8ch-ct-vt-module","title":"UR8CH | GE Multilin UR 8CH CT\/VT Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-8CH\u003c\/strong\u003e is a \u003cstrong\u003eCT\/VT Module\u003c\/strong\u003e (Current Transformer \/ Voltage Transformer) from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module features \u003cstrong\u003eeight independent channels\u003c\/strong\u003e suitable for CT or VT inputs, ensuring flexibility in configuration for diverse protection schemes. The UR-8CH supports \u003cstrong\u003edifferential protection, concurrent split-phase protection, and distance protection\u003c\/strong\u003e, making it a versatile solution for power system management.\u003c\/p\u003e\n\n\u003cp\u003eThe module incorporates \u003cstrong\u003eenhanced diagnostics capabilities\u003c\/strong\u003e to bolster system reliability and facilitate proactive maintenance. It communicates seamlessly with SCADA and other control systems through \u003cstrong\u003eModbus RTU and DNP3\u003c\/strong\u003e protocols.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 independent channels\u003c\/strong\u003e for CT or VT inputs — flexible configuration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupports multiple protection schemes:\u003c\/strong\u003e differential, concurrent split-phase, and distance protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced diagnostics\u003c\/strong\u003e for system reliability and proactive maintenance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication capabilities\u003c\/strong\u003e via Modbus RTU and DNP3 protocols\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCT Input Range:\u003c\/strong\u003e 0.5 A to 5 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVT Input Range:\u003c\/strong\u003e 5 V to 250 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCT Accuracy:\u003c\/strong\u003e Class 0.5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVT Accuracy:\u003c\/strong\u003e Class 0.2\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCT\/VT Module (Order Code: 8C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eChannels\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e8 independent\u003c\/strong\u003e (CT or VT configurable)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCT Input Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e0.5 A to 5 A\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVT Input Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e5 V to 250 V\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCT Accuracy\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 0.5\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVT Accuracy\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 0.2\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCT Burden\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e5 VA\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVT Burden\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e2 VA\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication Protocols\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModbus RTU, DNP3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eProtection of feeders, transformers, and generators\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eDifferential protection schemes\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eConcurrent split-phase protection\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eDistance protection for transmission lines\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eControl of switching operations\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAutomation of substation processes\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-8CH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. Its eight configurable channels provide greater flexibility compared to standard 4CT\/4VT modules. Always pair new CT\/VT modules with compatible CPU modules to avoid hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the CT\/VT slot position per the relay manual.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-8CH into the designated slot, aligning the rear connector with the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect CT and VT secondary wiring per the UR series wiring diagram. \u003cstrong\u003eEnsure secondary windings are properly grounded.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure CT\/VT ratios and channel assignments via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"8C\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"8C\" designates a \u003cstrong\u003eCT\/VT module with 8 configurable channels\u003c\/strong\u003e for flexible CT\/VT input assignment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can all 8 channels be used as CT inputs?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-8CH supports \u003cstrong\u003eflexible configuration\u003c\/strong\u003e — channels can be assigned as CT or VT inputs depending on application requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What protection schemes are supported?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-8CH supports \u003cstrong\u003edifferential protection, concurrent split-phase protection, and distance protection\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the UR-8CH compatible with older UR CPUs?\u003c\/strong\u003e\u003cbr\u003e\nA: Compatibility depends on firmware version. New CT\/VT modules should be paired with \u003cstrong\u003ecompatible CPUs\u003c\/strong\u003e to avoid hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-8CH\u003c\/strong\u003e when you need \u003cstrong\u003e8 configurable CT\/VT channels\u003c\/strong\u003e for flexible protection schemes.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003estandard 4CT\/4VT\u003c\/strong\u003e applications, consider the \u003cstrong\u003eUR-8AH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eenhanced diagnostics\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-8LH\u003c\/strong\u003e or \u003cstrong\u003eUR-8NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways verify \u003cstrong\u003eCPU and firmware compatibility\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-8CH \/ UR8CH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series CT\/VT Module — 8 Configurable Channels, Enhanced Diagnostics\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759636570296,"sku":"UR8CH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR8BV_2.png?v=1783925586"},{"product_id":"ge-multilin-ur7jh-digital-i-o-module","title":"GE Multilin UR7JH Digital I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-7JH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003e4 Form-C outputs\u003c\/strong\u003e (SPDT changeover contacts) and \u003cstrong\u003e4 digital inputs\u003c\/strong\u003e, enabling flexible control and monitoring of auxiliary equipment within substations and industrial power systems. The UR-7JH is characterized by the \u003cstrong\u003eorder code \"7J\"\u003c\/strong\u003e, which designates this specific I\/O configuration in the UR series.\u003c\/p\u003e\n\n\u003cp\u003eThe module's \u003cstrong\u003eForm-C outputs\u003c\/strong\u003e provide greater switching flexibility with normally open (NO), normally closed (NC), and common (C) terminals, making it ideal for applications requiring changeover contact logic. The UR-7JH is fully compatible with \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software for streamlined configuration and diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Form-C outputs\u003c\/strong\u003e (SPDT changeover contacts) for flexible switching\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Digital inputs\u003c\/strong\u003e for external signal monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForm-C contact versatility\u003c\/strong\u003e — NO, NC, and Common terminals per output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and system upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexLogic™ programmable logic\u003c\/strong\u003e support for custom protection schemes\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 7J)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 channels\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 × Form-C (SPDT)\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOutput Contact Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eChangeover: NO \/ NC \/ Common\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — breaker status monitoring, interlocking, and control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenerator and transformer protection\u003c\/strong\u003e — digital I\/O expansion for trip and alarm signaling\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeeder protection\u003c\/strong\u003e — auxiliary equipment control and status indication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial power systems\u003c\/strong\u003e — control of fans, valves, alarms, and other auxiliary devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA integration\u003c\/strong\u003e — status input and command output interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-7JH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. Modules can be mixed within the same chassis for scalable system upgrades. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-7JH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Form-C outputs provide NO, NC, and Common terminals for flexible switching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"7J\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"7J\" designates a digital I\/O module with \u003cstrong\u003e4 Form-C outputs + 4 digital inputs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between Form-A and Form-C outputs?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eForm-A\u003c\/strong\u003e is a single normally open (NO) contact. \u003cstrong\u003eForm-C\u003c\/strong\u003e is a changeover (SPDT) contact with NO, NC, and Common terminals, providing greater switching flexibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the UR-7JH be used for breaker tripping?\u003c\/strong\u003e\u003cbr\u003e\nA: The Form-C outputs can be used for breaker control. For high-current tripping applications, verify contact ratings against your breaker coil requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-7JH\u003c\/strong\u003e when you need a \u003cstrong\u003ebalanced 4-in \/ 4-out configuration\u003c\/strong\u003e with Form-C changeover contacts.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003emore Form-C outputs\u003c\/strong\u003e (6 or 8), consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e or \u003cstrong\u003eUR-6EV\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-A outputs\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6HH\u003c\/strong\u003e, \u003cstrong\u003eUR-6TH\u003c\/strong\u003e, or \u003cstrong\u003eUR-6UH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-7JH \/ UR7JH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 4 Form-C Outputs + 4 Digital Inputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759648432312,"sku":"UR7JH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR7JH.png?v=1783925661"},{"product_id":"ur7jv-ge-multilin-ur-7jv-protection-relay-module","title":"UR7JV | GE Multilin UR 7JV Protection Relay Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-7JV\u003c\/strong\u003e is a \u003cstrong\u003eProtection Relay Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module safeguards critical electrical assets such as \u003cstrong\u003efeeders, transformers, and motors\u003c\/strong\u003e, delivering comprehensive protection functions including \u003cstrong\u003eovercurrent, undervoltage, overload, and motor protection\u003c\/strong\u003e. Engineered for industrial-grade reliability, the UR-7JV ensures safe, efficient, and reliable operation in utility and industrial power systems.\u003c\/p\u003e\n\n\u003cp\u003eThe module supports \u003cstrong\u003eModbus TCP\/IP communication\u003c\/strong\u003e, enabling seamless integration with \u003cstrong\u003edistributed control systems (DCS)\u003c\/strong\u003e and \u003cstrong\u003eprogrammable logic controllers (PLC)\u003c\/strong\u003e. Its rugged, industrial-grade design provides high reliability in harsh environmental conditions, while \u003cstrong\u003eevent recording and diagnostic features\u003c\/strong\u003e enhance fault visibility and system uptime.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive protection elements:\u003c\/strong\u003e Overcurrent, undervoltage, overload, and motor protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModbus TCP\/IP communication\u003c\/strong\u003e for easy DCS\/PLC integration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEvent reports and fault recordings\u003c\/strong\u003e for troubleshooting and system improvements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible functionality\u003c\/strong\u003e — protects feeders, transformers, and motors from electrical issues\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental durability\u003c\/strong\u003e — built to endure harsh industrial conditions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and system upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e for configuration and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProtection Relay Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProtection Functions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOvercurrent, Undervoltage, Overload, Motor Protection\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication Protocol\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e100 mm × 80 mm × 20 mm\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eMotor and transformer protection systems\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eFeeder and busbar protection\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eSubstation automation and control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eIndustrial process and power distribution networks\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA integration\u003c\/strong\u003e — remote monitoring and control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-7JV is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It integrates seamlessly with other UR modules including CPU, CT\/VT, digital I\/O, and communication modules. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded electrostatic discharge (ESD) wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module's physical orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-7JV into the chassis guide rails, aligning the rear terminal block with the backplane connector. Push firmly until the faceplate sits flush.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Observe correct polarity for all connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on the relay and configure protection settings via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software or the front panel keypad\/LCD.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection functions does the UR-7JV provide?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-7JV provides \u003cstrong\u003eovercurrent, undervoltage, overload, and motor protection\u003c\/strong\u003e functions to safeguard critical electrical assets.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocol does the UR-7JV support?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-7JV supports \u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e for seamless integration with DCS and PLC systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the UR-7JV be used for transformer protection?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The UR-7JV is designed to protect \u003cstrong\u003efeeders, transformers, and motors\u003c\/strong\u003e from electrical issues.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What software is required for configuration?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e is the official GE software for configuring, monitoring, and diagnosing all UR series modules.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-7JV\u003c\/strong\u003e when you need a \u003cstrong\u003ecompact protection relay module\u003c\/strong\u003e with overcurrent, undervoltage, overload, and motor protection capabilities.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003ecommunication modules with RS485 and Ethernet\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-7JH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003edigital I\/O expansion\u003c\/strong\u003e, consider the UR-6 series modules (UR-6CH, UR-6HH, UR-6TH).\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e to confirm the exact module configuration before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-7JV \/ UR7JV\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Protection Relay Module — Overcurrent, Undervoltage, Overload, Motor Protection, Modbus TCP\/IP\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759658361016,"sku":"UR7JV","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR7JV_2.png?v=1783925654"},{"product_id":"general-electric-is200tturh1c-terminal-turbine-board","title":"General Electric IS200TTURH1C Terminal Turbine Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TTURH1C\u003c\/strong\u003e is a \u003cstrong\u003eTurbine Control Terminal Board\u003c\/strong\u003e for the Mark VI and Mark VIe Speedtronic systems. It provides \u003cstrong\u003egenerator synchronization and trip logic interfacing\u003c\/strong\u003e through hardware mechanisms and interconnections, featuring three onboard relays, six 37-pin interfaces, and two centrally positioned transformers. The board supports configurable simplex or TMR voting via jumper switches, making it adaptable to both standard and redundant turbine control architectures. \u003cstrong\u003eNote:\u003c\/strong\u003e This is a synchronization\/trip terminal board, not a primary speed control module.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e IS200TTURH1C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Turbine Control Terminal Board (Synchronization \u0026amp; Trip Logic)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VI \/ Mark VIe Speedtronic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e 3 onboard surface-mounted relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e Six 37-pin D-shell connectors (male\/female)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransformers:\u003c\/strong\u003e 2 centrally positioned transformers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoting Configuration:\u003c\/strong\u003e Simplex or TMR (jumper-selectable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVariable Resistors:\u003c\/strong\u003e Onboard for signal adjustment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Speed:\u003c\/strong\u003e 5100 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 125 VDC (typical)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e ~35 × 25 × 6 cm (varies by source)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5–0.8 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount the IS200TTURH1C in a standard Mark VI\/VIe rack.\u003c\/li\u003e\n  \u003cli\u003eSet jumper switches for simplex or TMR voting according to system architecture.\u003c\/li\u003e\n  \u003cli\u003eConnect 37-pin cables to PTUR and VTUR boards for turbine control interconnection.\u003c\/li\u003e\n  \u003cli\u003eVerify relay operation and transformer continuity using diagnostic tools.\u003c\/li\u003e\n  \u003cli\u003ePerform synchronization tests to confirm proper generator paralleling functionality.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What does TTUR stand for?\u003c\/strong\u003e\u003cbr\u003eA: TTUR is the functional acronym for Turbine Trip\/Control Terminal Board, handling synchronization and trip logic interfacing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Is TTUR a speed control board?\u003c\/strong\u003e\u003cbr\u003eA: No. TTUR is a terminal board for synchronization and trip circuits. Primary turbine speed control is handled by dedicated processor boards such as the TMR controller.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: How is TMR voting configured?\u003c\/strong\u003e\u003cbr\u003eA: TMR voting is enabled via onboard jumper switches; consult the Mark VI installation manual for specific jumper positions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What boards does TTUR interface with?\u003c\/strong\u003e\u003cbr\u003eA: It communicates with PTUR (Primary Turbine) and VTUR (Vibration\/Turbine) boards via D-shell connectors and terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUse IS200TTURH1C for generator synchronization and turbine trip interfacing in Mark VI\/VIe systems.\u003c\/li\u003e\n  \u003cli\u003eEnsure jumper settings match the redundancy architecture (simplex vs. TMR) before installation.\u003c\/li\u003e\n  \u003cli\u003ePair with compatible PTUR\/VTUR boards for complete turbine control functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eData Source:\u003c\/strong\u003e Parameters verified against WOC and Ubest PLC hardware specifications. For complete wiring and jumper configuration, refer to GE Mark VI terminal board installation manual (GEI-100462 series).\u003c\/em\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53776596467896,"sku":"IS200TTURH1C","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200TTURH1C_2r180_9a23305f-19aa-4495-acc6-6b04a0c37c61.png?v=1784184283"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/ge-multilin.oembed?page=2","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}