{"title":"Honeywell ControlEdge HC900 IO Modules","description":"\u003cp\u003eThe Honeywell ControlEdge HC900 I\/O platform provides a high-performance interface between field instrumentation and the controller, bridging the gap between discrete and process automation. This series is distinguished by its \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"249\"\u003eUniversal Analog Input\u003c\/b\u003e modules, which significantly reduce hardware overhead by allowing thermocouples, RTDs, and voltage\/current inputs to be mixed on a single card. Engineered for high availability, these modules support \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"472\"\u003ehot-swapping\u003c\/b\u003e (RIUP) and are available in SIL-2 certified versions for mission-critical safety applications like Burner Management Systems (BMS) and Emergency Shutdown (ESD). With a focus on signal integrity and ruggedness, the HC900 I\/O modules feature galvanic isolation and integrated diagnostics, ensuring accurate data acquisition in harsh electromagnetic environments. Whether managing complex thermal processing or high-density digital logic, these modules provide the scalability and precision required for TUV-compliant operations.\u003c\/p\u003e","products":[{"product_id":"analog-input-module-900a01-0001-honeywell","title":"Analog Input Module 900A01-0001 Honeywell","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900A01-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density universal analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell HC900 Control System\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight independent channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapable of interfacing with a wide range of sensor types—including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouples, RTDs, and standard voltage\/current transmitters\u003c\/strong\u003e—without the need for external signal conditioning.\u003c\/p\u003e\n\u003cp\u003eThis module performs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal linearization, cold-junction compensation, and galvanic isolation\u003c\/strong\u003e, ensuring precise digital acquisition for critical process applications. Its flexibility makes it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal processing, pharmaceutical manufacturing, water treatment, and HVAC control\u003c\/strong\u003e, where multiple sensor types coexist within a single I\/O rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900A01-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell HC900 Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Universal Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25–40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHC900 I\/O Rack (DIN rail compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring high-temperature furnaces with multiple thermocouple types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring temperature and humidity via RTDs and voltage sensors in cleanrooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Dosing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking 4–20 mA flow and level signals for precise reagent control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-point temperature sensing for industrial chilling and heating units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate terminal block?\u003c\/strong\u003e\u003cbr\u003eYes. The 900A01-0001 requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20-terminal Remote Termination Panel (RTP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEuro-style terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., part number 900TE1-0001) for field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan different input types be mixed on the same module?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. Each channel is independently configurable through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHC900 Designer software\u003c\/strong\u003e, allowing, for example, a thermocouple on Channel 1 and a 4–20 mA transmitter on Channel 2.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52521132196024,"sku":"900A01-0001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900A01-00012_2_23fe6cc2-7532-453c-bd1d-63420d0f014d.jpg?v=1770017080"},{"product_id":"900b01-0001-honeywell-analog-output-module","title":"900B01-0001 Honeywell Analog Output Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B01-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance, isolated analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell HC900 Control System\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour independent channels\u003c\/strong\u003e, enabling precise control of field devices such as actuators, control valves, and Variable Frequency Drives (VFDs). With robust isolation and flexible signal options, this module is ideal for deterministic process control in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eEach channel is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanically isolated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the backplane and other channels, protecting the controller logic from ground loops and electrical interference. Its wide operating temperature and humidity ranges ensure reliable performance in both indoor control rooms and harsh remote process enclosures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900B01-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell HC900 Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Isolated Analog Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, 0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Backplane Powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 mA per channel (internal logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field and logic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.8 cm x 7.8 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.72 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulating Valve Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivering precise 4–20 mA signals to actuators in steam or liquid flow loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Speed Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlling pump or fan speeds via VFDs using 0–10 V signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging industrial dampers and heating elements in large-scale facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulating fuel-to-air ratios through analog actuator positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 900B01-0001 support current (4–20 mA) output?\u003c\/strong\u003e\u003cbr\u003eYes. It supports both current loops (4–20 mA, 0–20 mA) and voltage outputs (0–10 VDC), making it a universal analog output module for the HC900.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal block is required for this module?\u003c\/strong\u003e\u003cbr\u003eThe module typically uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20-terminal block (Part Number 900TE1-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field wiring. This is usually ordered separately or as part of an I\/O kit.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52521149825208,"sku":"900B01-0001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900B01-00011_505185a4-3340-4215-8306-96d9c234ce43.jpg?v=1770017080"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/honeywell-controledge-hc900-io-modules.oembed","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}