{"title":"Honeywell Series 8 I\/O \u0026 C300 Controller","description":"\u003cp\u003eThe Honeywell C300 controller and Series 8 I\/O represent the modern standard for high-performance process automation. Featuring a unique vertical design for improved heat dissipation and space-efficient wiring, the Series 8 hardware is built for high-availability environments. This category includes the C300 controller, I\/O modules, and specialized Field Termination Assemblies (FTAs) designed to reduce installation complexity. These components provide the processing power and reliability required for the most demanding Experion PKS applications, ensuring your facility operates at peak efficiency.\u003c\/p\u003e","products":[{"product_id":"8c-ip0101-51454362-175-honeywell-standard-i-o-module","title":"8C-IP0101 51454362-175 Honeywell Standard I\/O Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-IP0101 (P\/N: 51454362-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a core component of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series 8 C300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware platform. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard I\/O Termination Assembly (IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the physical interface between field wiring and the Series 8 control system, ensuring reliable signal termination, grounding, and distribution for process automation loops.\u003c\/p\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evertical DIN-rail mounting\u003c\/strong\u003e, the module maximizes cabinet space efficiency while maintaining robust electrical connectivity. Its industrial-grade construction supports continuous operation in harsh process environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-IP0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngineering No.\u003c\/td\u003e\n\u003ctd\u003e51454362-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e150 × 80 × 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVertical DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe 8C-IP0101 is widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability control systems\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas refining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt functions as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical termination layer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor C300 controller I\/O, supporting multiple signal types based on the installed I\/O module.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 8C-IP0101 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eA: No. While many Series 8 I\/O modules support hot-swap, the IOTA itself is a passive component and should only be installed or replaced when the system is in a safe state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit include I\/O electronics?\u003c\/strong\u003e\u003cbr\u003eA: No. The 8C-IP0101 is the termination base only. I\/O electronics modules are supplied separately.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52511061967032,"sku":"8C-IP0101 51454362-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/8C-IP0101_51454362-175.jpg?v=1769670774"},{"product_id":"honeywell-cc-kfpvr5-51202353-111-fiber-optic-ethernet-cable-0-5m","title":"Honeywell CC-KFPVR5 51202353-111 Fiber Optic Ethernet Cable, 0.5m","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-KFPVR5 51202353-111 is a 0.5-meter violet Fiber Optic Ethernet communication cable designed for Process Manager Input\/Output Link (IOL FOE PM) modules to deliver high-speed, noise-immune data transmission between controller networks and field components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Fiber Optic Ethernet Cable\u003c\/li\u003e\n\u003cli\u003ePart Number: 51202353-111\u003c\/li\u003e\n\u003cli\u003eModel: CC-KFPVR5\u003c\/li\u003e\n\u003cli\u003eDescription: IOL FOE PM VIOLET - 0.5M\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eCable Type: Fiber Optic Ethernet\u003c\/li\u003e\n\u003cli\u003eConnector Type: Input\/Output Link (IOL) connectors\u003c\/li\u003e\n\u003cli\u003eLength: 0.5 meters\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 24 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Current: 0.5 A\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption: 12 W\u003c\/li\u003e\n\u003cli\u003eCustoms Tariff Number (HS Code): 8537101190\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003eDimensions: 16 cm x 16.2 cm x 1.5 cm\u003c\/li\u003e\n\u003cli\u003eWeight: 0.06 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the fiber optic cable within the designated cabinet wire ducts avoiding any sharp bends or pinching hazards.\u003c\/li\u003e\n\u003cli\u003eAlign and insert the IOL connectors firmly into the matching Input\/Output Link transceiver ports until locked.\u003c\/li\u003e\n\u003cli\u003eEnsure all adjacent active electronics operate within the standard 24 VDC threshold prior to link active status.\u003c\/li\u003e\n\u003cli\u003eVerify that cable tension remains completely slack and dimensions match the 16x16.2cm footprint tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617558945976,"sku":"51202353-111","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-KFPVR5r270.png?v=1782201389"},{"product_id":"51202353-200-honeywell-cc-kfsgr5-fiber-optic-extender-cable","title":"51202353-200 | Honeywell CC-KFSGR5 Fiber Optic Extender Cable","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-KFSGR5 51202353-200 is a high-performance fiber optic extender cable designed for Experion PKS C300 control systems and Series C Modular Termination Link (MTL) assemblies.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Fiber Optic Extender Cable\u003c\/li\u003e\n\u003cli\u003ePart Number: 51202353-200\u003c\/li\u003e\n\u003cli\u003eModel: CC-KFSGR5\u003c\/li\u003e\n\u003cli\u003eRevision: Rev C\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Experion PKS C300 \/ Series C MTL Systems\u003c\/li\u003e\n\u003cli\u003eMode Type: Single Mode\u003c\/li\u003e\n\u003cli\u003eNumber of Cores: 6 Core\u003c\/li\u003e\n\u003cli\u003eData Rate: Up to 100 Mbps\u003c\/li\u003e\n\u003cli\u003eMaximum Transmission Distance: Up to 2 km\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 24 VDC\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -40 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003eJacket Material: Industrial-grade PVC\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003eProduct Net Weight: 0.35 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the fiber optic extender cable carefully through dedicated industrial wire trays, keeping strict clearance from sharp edges.\u003c\/li\u003e\n\u003cli\u003eObserve the minimum bend radius requirements for single-mode fiber lines during installation to prevent internal core micro-fractures.\u003c\/li\u003e\n\u003cli\u003eClean the optical interface connector tips thoroughly using specialized fiber-wipes before mating with the C300 or MTL module ports.\u003c\/li\u003e\n\u003cli\u003eVerify that cable tension is completely relieved and the network link status LEDs indicate stable data sync during initial loop verification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617607606456,"sku":"51202353-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-KFSGR5_51202353-200_2__r270.png?v=1782201391"},{"product_id":"51403892-100-honeywell-cc-mcar01-mounting-carrier","title":"51403892-100 | Honeywell CC-MCAR01 Mounting Carrier","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-MCAR01 51403892-100 is a 24 V DC mounting carrier assembly designed for Series C hardware systems. It serves as a rugged structural backplane to distribute high-current power and provide unified grounding for control modules within a cabinet environment.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProduct Type: Mounting Carrier\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51403892-100\u003c\/li\u003e\n  \u003cli\u003eModel: CC-MCAR01\u003c\/li\u003e\n  \u003cli\u003eAssociated Part Number: 51403884-100\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eSupply Voltage: 24 V DC (-15% to +30%)\u003c\/li\u003e\n  \u003cli\u003eSupply Rail Current: Max. 40 A\u003c\/li\u003e\n  \u003cli\u003e24V Supply Connections: 2 x M5 holes\u003c\/li\u003e\n  \u003cli\u003ePower Rails: Two rails with M5 holes (+24V and 0V)\u003c\/li\u003e\n  \u003cli\u003eGround Rail: 16 ground connection screws\u003c\/li\u003e\n  \u003cli\u003eMechanical Composition: One metal profile, one plastic cover plate\u003c\/li\u003e\n  \u003cli\u003eMounting Holes: Four holes (6.35 mm diameter)\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature: -40 °C to +70 °C (-40 °F to +158 °F)\u003c\/li\u003e\n  \u003cli\u003eStorage Temperature: -40 °C to +85 °C (-40 °F to +185 °F)\u003c\/li\u003e\n  \u003cli\u003eRelative Humidity: 10% to 95% (non condensing)\u003c\/li\u003e\n  \u003cli\u003eCustoms Tariff Number (HS Code): 8537101190\u003c\/li\u003e\n  \u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n  \u003cli\u003eProcurement Location: Xiamen, China\u003c\/li\u003e\n  \u003cli\u003eDimensions: 8.2 cm x 12.2 cm x 6 cm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFeatures dual heavy-duty power rails with M5 connections capable of distributing up to 40 A of 24 V DC supply current.\u003c\/li\u003e\n  \u003cli\u003eIncludes an integrated ground rail equipped with 16 dedicated screws to ensure reliable, low-impedance grounding paths.\u003c\/li\u003e\n  \u003cli\u003eConstructed from a robust metal profile paired with a protective plastic cover plate to shield active components.\u003c\/li\u003e\n  \u003cli\u003eDesigned with four precision 6.35 mm diameter mounting holes for secure anchoring to control panel structures.\u003c\/li\u003e\n  \u003cli\u003eEngineered to operate reliably across a wide temperature range from -40 °C to +70 °C under high relative humidity levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFix the metal profile to the cabinet frame or back panel through the four 6.35 mm mounting holes using appropriate fasteners.\u003c\/li\u003e\n  \u003cli\u003eTerminate the primary 24 V DC power cables securely into the designated M5 power rail holes (+24V and 0V) observing correct torque specifications.\u003c\/li\u003e\n  \u003cli\u003eConnect module and shield grounds directly to the 16-point ground rail to establish proper instrumentation earth.\u003c\/li\u003e\n  \u003cli\u003eEnsure the plastic cover plate is snapped into its correct protective alignment before energizing the 40 A power supply rail.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617624481976,"sku":"51403892-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-MCAR01_51403892-100.png?v=1782201392"},{"product_id":"cc-paim01-51405045-175-honeywell-low-level-analog-input-multiplexer-iop-module","title":"CC-PAIM01 51405045-175 | Honeywell Low-Level Analog Input Multiplexer IOP Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIM01 51405045-175 is a Series C Low-Level Analog Input Multiplexer (LLMUX) IOP module. It is uniquely engineered to interface the Experion Series C platform with existing solid-state PMIO LLMUX Field Termination Assemblies (FTAs), supporting up to 64 channels of high-density, fully-isolated temperature and millivolt measurements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Low Level Analog (Temperature) Input Module (LLMUX)\u003c\/li\u003e\n\u003cli\u003ePart Number: 51405045-175\u003c\/li\u003e\n\u003cli\u003eModel: CC-PAIM01\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520)\u003c\/li\u003e\n\u003cli\u003eCompatible PMIO FTA Models: MU-TAMR04, TAMT04, TAMT14 (16 channels per FTA)\u003c\/li\u003e\n\u003cli\u003eInput Channels: Up to 64 fully-isolated channels (expanded in 16-channel increments)\u003c\/li\u003e\n\u003cli\u003eIsolation: Channel-to-channel, channel-to-PM, and channel-to-power supply common\u003c\/li\u003e\n\u003cli\u003eInput Scan Rate: 1 Second fixed rate by IOM for all active channels (64 channels\/sec max)\u003c\/li\u003e\n\u003cli\u003eChannel Bandwidth: 0 to 4.7 Hz (-3 dB)\u003c\/li\u003e\n\u003cli\u003eNominal Input Range (TC Only): -20 to +100 millivolts\u003c\/li\u003e\n\u003cli\u003eMaximum Non-Damaging Input (Continuous): -10 to +10 V (TC) \/ -1 to +2 V @ 100 mA (RTD)\u003c\/li\u003e\n\u003cli\u003eGain Error: 0.050% full scale max (-20 to +100 mV range)\u003c\/li\u003e\n\u003cli\u003eTemperature Stability: ±20 ppm per °C max (TC, millivolt, and RTD inputs)\u003c\/li\u003e\n\u003cli\u003eLong Term Drift: 500 ppm\u003c\/li\u003e\n\u003cli\u003eInput Impedance: 1 megohm at dc (TC only)\u003c\/li\u003e\n\u003cli\u003eCommon Mode Voltage (CMV): ±250 VDC or VAC RMS (with respect to Power System common, dc to 60 Hz)\u003c\/li\u003e\n\u003cli\u003eCMRR (50\/60 Hz): 120 dB min (with 1000 ohms max source impedance)\u003c\/li\u003e\n\u003cli\u003eVoltage (Channel-to-Channel): ±250 VDC or VAC RMS (dc to 60 Hz)\u003c\/li\u003e\n\u003cli\u003eCrosstalk (dc to 60 Hz): 80 dB (120 dB at 50 Hz and 60 Hz)\u003c\/li\u003e\n\u003cli\u003eNMRR (50\/60 Hz): 60 dB min\u003c\/li\u003e\n\u003cli\u003eLine Frequency Integration: Fixed selection of 50 Hz or 60 Hz\u003c\/li\u003e\n\u003cli\u003eRTD Sensor Excitation Current: 1 milliamp\u003c\/li\u003e\n\u003cli\u003eCold Junction Reference (CJR) Accuracy: ±1.0 °C Max (0 to +50 °C) \/ ±1.5 °C Max (-20 to +60 °C)\u003c\/li\u003e\n\u003cli\u003eTC Linearization Accuracy: Based on 4th order polynomials (NIST Monograph 175, ITS90, JIS C-1602-1995)\u003c\/li\u003e\n\u003cli\u003eOpen Thermocouple Detection (OTD): Qualified per conversion (≤1000 Ω guaranteed no-trip, ≥1500 Ω guaranteed trip)\u003c\/li\u003e\n\u003cli\u003eRTD Max Lead Resistance: 15 Ω\u003c\/li\u003e\n\u003cli\u003eSurge Protection (Sensor Terminals): EN 61000-4-5 (1kV line-to-line, 2kV line-to-gnd)\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Distance (IOTA to FTA): 1000 feet (16 gauge wire, two twisted pair per FTA via cable adapter)\u003c\/li\u003e\n\u003cli\u003ePMIO FTA Dimensions: 63.5 mm D x 124.46 mm W x 307.34 mm L (2.5\" D x 4.9\" W x 12.1\" L)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupported Measurement Profiles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Sensors:\u003c\/strong\u003e Pt100 DIN 4376 (-180 to +800°C), Pt100 JIS C-1604 (-180 to +650°C), Ni120 ED #7 (-45 to +315°C), Cu10 SEER (-20 to +250°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouples (ANSI Spec):\u003c\/strong\u003e Type J (-200 to +1200°C), Type K (-100 to +1370°C), Type E (-200 to +1000°C), Type T (-230 to +400°C), Type B (+100 to +1820°C), Type S (0 to +1700°C), Type R (0 to +1700°C), JAPAN TYPE R’ (0 to +1770°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Millivolt:\u003c\/strong\u003e -20 to +100 millivolts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the compatible PMIO FTAs inside dedicated FTA channels (Note: these mounting spaces are similar to but distinct from standard Series C channels).\u003c\/li\u003e\n\u003cli\u003eConnect the CC-PAIM01 module interface to the field termination block via the required cable adapter option up to a maximum distance of 1000 feet.\u003c\/li\u003e\n\u003cli\u003eConfigure the line frequency integration parameters to exactly 50 Hz or 60 Hz to ensure the 120 dB common-mode rejection performance.\u003c\/li\u003e\n\u003cli\u003eVerify that the total loop resistance for active 3-wire\/4-wire RTD sensor paths remains strictly under the 15 Ω threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617646502072,"sku":"51405045-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PAIM01_r270.png?v=1782201382"},{"product_id":"cc-pain01-51410069-175-honeywell-high-level-analog-input-module","title":"CC-PAIN01 51410069-175 | Honeywell High-Level Analog Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIN01 51410069-175 is a 16-channel non-HART High-Level Analog Input (HLAI) module designed specifically for the Experion PKS Series C I\/O architecture. It provides continuous 1-second process variable sampling for single-ended 4-20 mA current loops directly connected to the C300 controller platform.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Analog Input High Level Non-HART Module (16-point)\u003c\/li\u003e\n\u003cli\u003ePart Number: 51410069-175\u003c\/li\u003e\n\u003cli\u003eAssociated Circuit Board Part Number: 51405038-175 \/ 51405038-275\u003c\/li\u003e\n\u003cli\u003eModel: CC-PAIN01\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Experion PKS Series C \/ C300 Controller\u003c\/li\u003e\n\u003cli\u003eNumber of Channels: 16 Single-ended input channels\u003c\/li\u003e\n\u003cli\u003eInput Signal Type: 4 to 20 mA current loop\u003c\/li\u003e\n\u003cli\u003eA\/D Converter Resolution: 16-bit Sigma-Delta\u003c\/li\u003e\n\u003cli\u003eInput Impedance: 250 Ω nominal (for standard 4-20 mA to 1-5 V conversion)\u003c\/li\u003e\n\u003cli\u003eInput Scan Rate: 1 second fixed loop rate\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 1500 VDC (Channel-to-system and channel-to-frame isolation)\u003c\/li\u003e\n\u003cli\u003eMains Frequency Rejection: Configurable 50 Hz or 60 Hz filter parameters\u003c\/li\u003e\n\u003cli\u003eField Loop Power: Provided through independent current-limiting electronics per channel\u003c\/li\u003e\n\u003cli\u003eShort-Circuit Protection: Built-in per-channel current-limiting circuitry (No external fuses required)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -40 °C to +70 °C (-40 °F to +158 °F)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40 °C to +85 °C (-40 °F to +185 °F)\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 10% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eConformal Coating: Yes (Standard ISA-S71.04 Class G3 environmental coating protection)\u003c\/li\u003e\n\u003cli\u003eHazardous Area Approvals: Class I, Division 2 \/ Zone 2 Non-Incendive certified\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TAIN01 (51308301-125 \/ 51308301-175):\u003c\/strong\u003e Series C Analog Input Non-Redundant IOTA (6-inch width)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TAIN11 (51308303-125 \/ 51308303-175):\u003c\/strong\u003e Series C Analog Input Redundant IOTA (12-inch width)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlug the CC-PAIN01 module straight onto its designated slots on either the CC-TAIN01 (non-redundant) or CC-TAIN11 (redundant) IOTA board.\u003c\/li\u003e\n\u003cli\u003eSecurely tighten the built-in mechanical module screws into the IOTA backplane to establish proper earth and structural contact.\u003c\/li\u003e\n\u003cli\u003eEnsure that field signal shielding is terminated exclusively at the single-point common grounding rail of the Series C carrier assembly.\u003c\/li\u003e\n\u003cli\u003eVerify that the configured grid frequency rejection parameters (50 Hz or 60 Hz) match the local power plant layout inside Experion Control Builder.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617696637112,"sku":"51410069-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PAIN01.png?v=1782201391"},{"product_id":"cc-paoh01-51405039-175-honeywell-analog-output-module","title":"CC-PAOH01 51405039-175 | Honeywell Analog Output Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAOH01 is a 16-channel High-Level Analog Output Module with HART capability designed for the Experion Series C I\/O platform. It delivers high-level constant 4-20 mA current loops to control actuators, positioners, and recording\/indicating field devices, featuring extensive self-diagnostics and per-channel safe-state behaviors.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProduct Type: High-Level Analog Output with HART (16-point)\u003c\/li\u003e\n  \u003cli\u003eModel: CC-PAOH01\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Reference: Experion Series-C I\/O Specification, EP03-490-520 (Version 1.5)\u003c\/li\u003e\n  \u003cli\u003eOutput Channels: 16\u003c\/li\u003e\n  \u003cli\u003eOutput Type: 4-20 mA DC current loop\u003c\/li\u003e\n  \u003cli\u003eDirectly Settable Output Current Range: 0 mA, 2.9 mA to 21.1 mA\u003c\/li\u003e\n  \u003cli\u003eResolution: ± 0.05% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eCalibrated Accuracy: ± 0.35% of Full Scale (at 25 °C) including linearity\u003c\/li\u003e\n  \u003cli\u003eOutput Current Linearity: ± 0.05% of Full Scale nominal\u003c\/li\u003e\n  \u003cli\u003eOutput Temperature Drift: 0.005% of Full Scale\/°C\u003c\/li\u003e\n  \u003cli\u003eOutput Readback Accuracy: ±4% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eOutput Ripple: \u0026lt; 100 mV peak-to-peak at power line frequency (across 250 Ω load)\u003c\/li\u003e\n  \u003cli\u003eMaximum Resistive Load: 800 ohms (with 24 V supply ranging from 22 VDC through 28 VDC)\u003c\/li\u003e\n  \u003cli\u003eMaximum Output Compliant Voltage: 16 V (with 24 V supply ranging from 22 VDC through 28 VDC)\u003c\/li\u003e\n  \u003cli\u003eMaximum Open Circuit Voltage: 22 V\u003c\/li\u003e\n  \u003cli\u003eResponse Time (DAC Input Code to Output): Settles to within 1% of final value within 80 ms\u003c\/li\u003e\n  \u003cli\u003eRedundancy Switchover Gap (0 mA Output to Field): 10 ms maximum (applies to Redundancy only)\u003c\/li\u003e\n  \u003cli\u003eHART Capabilities: Supports multivariable instruments with multiple modems for fast collection of control variables\u003c\/li\u003e\n  \u003cli\u003eRedundancy Support: Optional (via specific Redundant IOTAs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX01:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX21:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFAILOPT Behavior:\u003c\/strong\u003e Supports configurable fail-option parameters defined on a per-channel basis. Each channel can be set to either \u003cem\u003eHOLD LAST VALUE\u003c\/em\u003e or \u003cem\u003eSHED to a SAFE VALUE\u003c\/em\u003e. If the IOM device electronics fail completely, the output always drops to 0 mA (the absolute safe state).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen-wire Detection:\u003c\/strong\u003e Automatically scans, detects, and annunciates open field wiring conditions via a Channel Soft Failure indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Read-back:\u003c\/strong\u003e Continuously monitors executed output values and generates system alarms upon tracking discrepancy detections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-incendive Output:\u003c\/strong\u003e Provides built-in non-incendive field circuit capability for deployment near hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInsert the CC-PAOH01 module onto its matched IOTA slot allocation (CC-TAOX01, CC-TAOX11, CC-GAOX11, or CC-GAOX21) depending on redundancy and environmental protection requirements.\u003c\/li\u003e\n  \u003cli\u003eEnsure that total external field loop loop resistance, including wire resistance and control valve positioner internal load, does not exceed the 800 Ω maximum threshold.\u003c\/li\u003e\n  \u003cli\u003eVerify that the maximum open circuit voltage stays bounded at 22 V under full diagnostic loops testing.\u003c\/li\u003e\n  \u003cli\u003eDefine individual channel FAILOPT behaviors (Hold Last Value or Safe Value target) inside the control network manager environment before executing C300 controller warm boot sequences.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617727602872,"sku":"51405039-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PAOH01_3.png?v=1782201392"},{"product_id":"honeywell-series-c-cc-paon01-51410070-175-analog-output-ao-module","title":"Honeywell Series C CC-PAON01 51410070-175 Analog Output (AO) Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAON01 51410070-175 is a 16-channel Non-HART High-Level Analog Output (AO) module designed for the Experion Series C I\/O platform. It delivers high-level constant current to actuators and recording\/indicating devices directly from the C300 controller, configured without HART pass-through requirements.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInput \/ Output Model: CC-PAON01 - High-Level Analog Output Non-HART\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51410070-175\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520_V10_SCIO_1_5)\u003c\/li\u003e\n  \u003cli\u003eOutput Type: 4-20 mA\u003c\/li\u003e\n  \u003cli\u003eOutput Channels: 16\u003c\/li\u003e\n  \u003cli\u003eOutput Ripple: \u0026lt; 100 mV peak-to-peak at power line frequency, across 250 Ω load\u003c\/li\u003e\n  \u003cli\u003eOutput Temperature Drift: 0.005% of Full Scale\/°C\u003c\/li\u003e\n  \u003cli\u003eOutput Readback Accuracy: ±4% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eOutput Current Linearity: ± 0.05% of Full Scale nominal\u003c\/li\u003e\n  \u003cli\u003eResolution: ± 0.05% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eCalibrated Accuracy: ± 0.35% of Full Scale (25°C) including linearity\u003c\/li\u003e\n  \u003cli\u003eDirectly Settable Output Current Range: 0 mA, 2.9 mA to 21.1 mA\u003c\/li\u003e\n  \u003cli\u003eMaximum Resistive Load (24 V supply = 22 VDC through 28 VDC): 800 ohms\u003c\/li\u003e\n  \u003cli\u003eMaximum Output Compliant Voltage (24 V supply = 22 VDC through 28 VDC): 16 V\u003c\/li\u003e\n  \u003cli\u003eMaximum Open Circuit Voltage: 22 V\u003c\/li\u003e\n  \u003cli\u003eResponse Time (DAC input code to output): Settles to within 1% of final value within 80 ms\u003c\/li\u003e\n  \u003cli\u003eGap (0 mA) of Output to Field on Switchover: 10 ms maximum (applies to Redundancy only)\u003c\/li\u003e\n  \u003cli\u003eOptional Redundancy: Supported\u003c\/li\u003e\n  \u003cli\u003eNon-incendive Output: Supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX01:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX21:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFAILOPT Behavior:\u003c\/strong\u003e Supports the FAILOPT parameter on a per-channel basis. The user can configure each channel to either \u003cem\u003eHOLD LAST VALUE\u003c\/em\u003e or \u003cem\u003eSHED to a SAFE VALUE\u003c\/em\u003e. The Output will always go to zero, the safe state, if the IOM device electronics fails.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen-wire Detection:\u003c\/strong\u003e Able to detect and annunciate open field wire with a Channel Soft Failure indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Read-back:\u003c\/strong\u003e Features output read-back and alarm on tracking discrepancy detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInsert the CC-PAON01 module onto its matched IOTA slot allocation (CC-TAOX01, CC-TAOX11, CC-GAOX11, or CC-GAOX21) inside the control cabinet enclosure.\u003c\/li\u003e\n  \u003cli\u003eEnsure that total external field loop resistance, including wire resistance and control valve positioner internal load, does not exceed the 800 Ω maximum threshold.\u003c\/li\u003e\n  \u003cli\u003eVerify that the maximum open circuit voltage stays bounded at 22 V under full operational testing.\u003c\/li\u003e\n  \u003cli\u003eDefine individual channel FAILOPT behaviors (Hold Last Value or Safe Value target) inside the control network manager environment before executing C300 controller logic down-loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617762238648,"sku":"51410070-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PAON01.png?v=1782201388"},{"product_id":"honeywell-cc-pcf901-51405047-176-fte-control-firewall-module","title":"Honeywell CC-PCF901 51405047-176 FTE Control Firewall Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PCF901 (51405047-176) is a 9-port Fault Tolerant Ethernet (FTE) Control Firewall Module designed for Experion PKS Series C networks. Acting as the secure communications center (CF9), it ensures critical network security inside the control cabinet by discarding non-essential Ethernet traffic and protecting the C300 controller domain from unauthorized network access or saturation failures.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProduct Type: Control Firewall Module (9-Port FTE Hub)\u003c\/li\u003e\n  \u003cli\u003eModel: CC-PCF901\u003c\/li\u003e\n  \u003cli\u003eAssociated Assembly Part Number: 51405047-176 (Control Firewall Board)\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eSystem Architecture: Experion PKS Series C Network Infrastructure\u003c\/li\u003e\n  \u003cli\u003eCommunication Ports: 9 Ports total (10\/100Base-TX interfaces)\u003c\/li\u003e\n  \u003cli\u003ePort Allocation Layout: 8 FTE ports for intra-cabinet Series C nodes, 1 Uplink port for external network segments\u003c\/li\u003e\n  \u003cli\u003eSupported Data Rates: 10 \/ 100 Mbps auto-sensing\u003c\/li\u003e\n  \u003cli\u003ePower Operating Voltage: 24 V DC nominal\u003c\/li\u003e\n  \u003cli\u003eCurrent Consumption \/ Supply Rating: 0.112 A @ 24VDC (Approx. 10 W power consumption)\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Range: -40 °C to +85 °C (-40 °F to +185 °F)\u003c\/li\u003e\n  \u003cli\u003eStorage Temperature Range: -40 °C to +85 °C (-40 °F to +185 °F)\u003c\/li\u003e\n  \u003cli\u003eRelative Humidity Limits: 5% to 95% non-condensing\u003c\/li\u003e\n  \u003cli\u003eShock Resistance Rating: 30 g peak for 11 ms\u003c\/li\u003e\n  \u003cli\u003eVibration Tolerance: 5 g peak at 20 to 500 Hz\u003c\/li\u003e\n  \u003cli\u003eModule Physical Dimensions: 190 mm x 69 mm x 23 mm (7.5 in x 2.7 in x 0.9 in)\u003c\/li\u003e\n  \u003cli\u003eProduct Net Weight: 0.45 kg (1 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Termination Assembly (IOTA)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCF9 IOTA (Control Firewall 9-Port Assembly):\u003c\/strong\u003e The module mounts and plugs directly onto the specialized CF9 IOTA backplane to distribute power and interface the 9 Fault Tolerant Ethernet ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Security \u0026amp; Communication Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFTE Packet Filtering:\u003c\/strong\u003e Rejects and filters out all inbound standard Ethernet broadcast\/multicast messages not explicitly required for process control execution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTraffic Prioritization:\u003c\/strong\u003e Automatically prioritizes data streams on the downlink ports over ingress traffic entering through the uplink network port if the communication fabric approaches saturation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eC300 Domain Protection:\u003c\/strong\u003e Validates protocol signatures to ensure only C300-compliant messages pass into the operational control layer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFTE Distribution:\u003c\/strong\u003e Provides localized, high-efficiency distribution of Fault Tolerant Ethernet links to multiple Series C FIMs (Fieldbus Interface Modules), C300 controllers, and intra-cabinet nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLED Diagnostics Indicators\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower LED:\u003c\/strong\u003e Steady green when primary 24 V DC input power is safely applied via the IOTA rail.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus LED:\u003c\/strong\u003e Illuminates Red during the initial Power-On Self-Test (POST); turns Green for normal system health; blinks Green to indicate active data traffic on connected internal nodes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDownlink\/Uplink Port LEDs:\u003c\/strong\u003e Displays Green when a reliable hardware link is present; flashes Green with ongoing packet traffic; flashes Red if too many unauthorized devices are detected on the link slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlug the CC-PCF901 module straight onto its matched slots on the CF9 Input\/Output Termination Assembly (IOTA) inside the Series C cabinet.\u003c\/li\u003e\n  \u003cli\u003eVerify that the 8 localized downlink ports are dedicated to intra-cabinet routing (C300s, FIMs) while the single uplink port connects back toward the main switch layers.\u003c\/li\u003e\n  \u003cli\u003eEnsure that your twisted-pair copper cable drops do not exceed standard industrial length limits and remain anchored away from heavy high-voltage components to maintain noise margins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617775083704,"sku":"51405047-176","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PCF901r270.png?v=1782201387"},{"product_id":"cc-pcnt01-51405046-175-honeywell-c300-controller-module","title":"CC-PCNT01 51405046-175 | Honeywell C300 Controller Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PCNT01 51405046-175 is the core C300 Process Controller Module for the Experion PKS Series C architecture. It executes robust, deterministic Control Execution Environment (CEE) software and serves as the primary distributed process controller and I\/O gateway across the plant's automation infrastructure.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProduct Type: C300 Controller Module\u003c\/li\u003e\n  \u003cli\u003eModel Code: CC-PCNT01\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51405046-175\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eSystem Architecture: Experion PKS Series C Infrastructure\u003c\/li\u003e\n  \u003cli\u003eSupply Voltage Rating: 24 V DC nominal\u003c\/li\u003e\n  \u003cli\u003eCurrent Consumption: 0.311 A @ 24 VDC\u003c\/li\u003e\n  \u003cli\u003eBase Execution Periods Supported (CEE): 50 ms baseline (20 ms optional with specific firmware and license)\u003c\/li\u003e\n  \u003cli\u003eControl Networks Supported: FTE (Fault Tolerant Ethernet) exclusively\u003c\/li\u003e\n  \u003cli\u003eNumber of I\/O Links Supported per Controller: 2 Links\u003c\/li\u003e\n  \u003cli\u003eI\/O Link Speed: 750 Kbaud (Series C I\/O Link); Note: 375 Kbaud (PMIO Link) is not supported under standard C300-20ms environments\u003c\/li\u003e\n  \u003cli\u003eRedundancy Support: Yes (Supports dual Active\/Standby hot-shadowing controller pairing)\u003c\/li\u003e\n  \u003cli\u003eTime Synchronization Source: SNTP, PTPv2\u003c\/li\u003e\n  \u003cli\u003eSNTP Update Period: 1 minute\u003c\/li\u003e\n  \u003cli\u003ePTP Update Period: 30 seconds\u003c\/li\u003e\n  \u003cli\u003eDevice Index Configuration Range: Between 1 and 510\u003c\/li\u003e\n  \u003cli\u003eHousing Material: Industrial-grade plastic enclosure with printed circuit assemblies, status indicators, and display\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Range: 0 °C to +60 °C\u003c\/li\u003e\n  \u003cli\u003ePhysical Dimensions: 22.1 cm x 12.1 cm x 8.0 cm (8.7 in x 4.76 in x 3.15 in)\u003c\/li\u003e\n  \u003cli\u003eProduct Net Weight: 0.34 kg (0.75 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Termination Assembly (IOTA Size)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eC300 Controller IOTA:\u003c\/strong\u003e The module mounts directly onto a standardized 6-inch (152 mm) C300 Input Output Termination Assembly (IOTA) block, providing integrated network connections and power distribution interfaces without standalone chassis frames.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Performance Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeterministic Control Environment:\u003c\/strong\u003e Runs Honeywell’s field-proven Control Execution Environment (CEE) to manage complex regulatory control, batch sequencing, and high-speed interlocking loop actions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault Tolerant Ethernet (FTE):\u003c\/strong\u003e Utilizes native, redundant FTE link ports via the IOTA backplane to secure robust peer-to-peer and supervisory control layer communications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLive Hot-Swapping:\u003c\/strong\u003e Supports\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617812701368,"sku":"51405046-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PCNT01_51405046-175.png?v=1782201394"},{"product_id":"honeywell-c300-cc-pcnt02-51454551-275-controller-module","title":"Honeywell C300 CC-PCNT02 51454551-275 Controller Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PCNT02 (Part Number: 51454551-275) is a high-performance C300 Controller Module designed for the Experion Process Knowledge System (PKS) platform. As an upgraded version of the CC-PCNT01, it provides double the usable memory (32MB compared to 16MB) and is strictly required to run \"Extended Functionality\" firmware, such as Profit Controller and Ethernet Interface Modules (EIM).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: C300 Controller Module (Upgraded \/ Enhanced Memory Version)\u003c\/li\u003e\n\u003cli\u003eModel Code: CC-PCNT02\u003c\/li\u003e\n\u003cli\u003ePart Number: 51454551-275\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 32 MB (Double the 16 MB capacity of CC-PCNT01)\u003c\/li\u003e\n\u003cli\u003eDevice Index Configuration Range: Between 1 and 510\u003c\/li\u003e\n\u003cli\u003eIOTA Module Size Requirement: 6 inches\u003c\/li\u003e\n\u003cli\u003eSupported Execution Periods (CEE): 50 ms \/ 50 ms\u003c\/li\u003e\n\u003cli\u003eNumber of I\/O Links Supported: 2\u003c\/li\u003e\n\u003cli\u003eI\/O Link Baud Rates: 375 Kbaud \/ 750 Kbaud\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -40 °C to +70 °C (-40 °F to +158 °F) [Extended range for new releases\/current hardware; older modules support 0–60°C]\u003c\/li\u003e\n\u003cli\u003eCustoms Tariff Number (HS Code): 8537101190\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003ePhysical Dimensions: 7.3 cm x 15.3 cm x 16.5 cm\u003c\/li\u003e\n\u003cli\u003eProduct Net Weight: 0.45 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNetwork \u0026amp; System Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Firewall (CF9) Integration:\u003c\/strong\u003e C300 controllers are connected over a dedicated Control Firewall, with the CF9 acting as the central network aggregator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFTE Capacity:\u003c\/strong\u003e Up to four (4) C300 controller modules can be securely connected via Ethernet through a single CF9 firewall assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Inspection:\u003c\/strong\u003e Aside from potential firmware mismatches, the most common reason for communication or initialization failure is a faulty IOTA base board or a bent pin on the module's multi-pin connector. Inspect the underside pins closely before seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Alignment:\u003c\/strong\u003e Ensure the module is perfectly vertical when lowering it onto the 6-inch IOTA socket to avoid shearing the connector interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Routing:\u003c\/strong\u003e Always route the controller's main network links directly through the CF9 firewall aggregation points to maintain appropriate protocol traffic filtering.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617839702200,"sku":"51454551-275","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PCNT02_3.png?v=1782201389"},{"product_id":"honeywell-cc-pdil01-51405040-175-digital-input-module-32-channel","title":"Honeywell CC-PDIL01 51405040-175 Digital Input Module,32-channel","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PDIL01 51405040-175 is a 32-channel Digital Input (DI) module designed for the Experion Series C I\/O platform. Operating at a nominal voltage of 24 V DC, it senses the open\/closed status of dry contacts or solid-state switches from field equipment and routes these discrete state variables directly to the C300 controller.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInput \/ Output Model: CC-PDIL01 - Digital Input 24 VDC\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51405040-175\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520_V10_SCIO_1_5)\u003c\/li\u003e\n  \u003cli\u003eInput Channels: 32 Channels\u003c\/li\u003e\n  \u003cli\u003eInput Voltage Range: 24 V DC nominal\u003c\/li\u003e\n  \u003cli\u003eInput Type: Sinking current input topology\u003c\/li\u003e\n  \u003cli\u003eGalvanic Isolation: 1500 VDC (Channel-to-system and channel-to-frame isolation)\u003c\/li\u003e\n  \u003cli\u003eChannel Scan Rate: Fixed loop update by Input Output Module (IOM) logic\u003c\/li\u003e\n  \u003cli\u003eOn-board Diagnostics: Extensive module self-diagnostics tracking hardware status\u003c\/li\u003e\n  \u003cli\u003eRedundancy Support: Optional (via specific Redundant IOTA blocks)\u003c\/li\u003e\n  \u003cli\u003eConformal Coating: Yes (Standard ISA-S71.04 Class G3 environmental coating protection)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TDIL01:\u003c\/strong\u003e Series C Digital Input Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TDIL11:\u003c\/strong\u003e Series C Digital Input Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GDIL11:\u003c\/strong\u003e Series C Digital Input Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GDIL21:\u003c\/strong\u003e Series C Digital Input Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density 32-Point Layout:\u003c\/strong\u003e Maximizes cabinet spacing efficiency by processing 32 individual discrete input lines on a single standard Series C card slot.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Status Reporting:\u003c\/strong\u003e Monitors field device contact state transitions and flags any internal hardware anomalies via standard Channel Soft Failure alerts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClass G3 Corrosive Shielding:\u003c\/strong\u003e Features full factory conformal coating to withstand aggressive industrial chemical environments matching ISA-S71.04 specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy Choice:\u003c\/strong\u003e Allows flexible engineering deployments supporting both non-redundant configurations or sub-second active\/standby switchover architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlug the CC-PDIL01 module firmly onto its appropriate IOTA slot configuration (CC-TDIL01, CC-TDIL11, CC-GDIL11, or CC-GDIL21) on the cabinet DIN rail carrier.\u003c\/li\u003e\n  \u003cli\u003eVerify that the external input loop power source remains tightly regulated around the nominal 24 V DC threshold to ensure correct logic high\/low detection.\u003c\/li\u003e\n  \u003cli\u003eSecure the integrated thumbscrews tightly to anchor the card module framework and lock down the primary structural grounding connection.\u003c\/li\u003e\n  \u003cli\u003eConfigure individual channel debounce filters and inversion parameters inside the Experion Control Builder tool environment before initiating an active database download.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617861755064,"sku":"51405040-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PDIL01_3e2b4846-bff6-44d9-9391-57aae221b644.png?v=1782201394"},{"product_id":"honeywell-cc-pdob01-51405043-175-digital-output-24v-module","title":"Honeywell CC-PDOB01 51405043-175 Digital Output 24V Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PDOB01 51405043-175 is a 32-channel Bussed Digital Output (DO) module designed for the Experion Series C I\/O platform. It provides 24 V DC sourcing outputs to drive field loads such as solenoids, relays, and indicator lights, utilizing a high-density bussed power distribution architecture via the IOTA.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInput \/ Output Model: CC-PDOB01 - Digital Output 24 VDC (Bussed)\u003c\/li\u003e\n  \u003cli\u003ePart Number: 51405043-175\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520_V10_SCIO_1_5)\u003c\/li\u003e\n  \u003cli\u003eOutput Channels: 32 Channels\u003c\/li\u003e\n  \u003cli\u003eOutput Type: Sourcing (Provides 24 V DC to the field load from a common bus)\u003c\/li\u003e\n  \u003cli\u003eNominal Supply Voltage: 24 V DC\u003c\/li\u003e\n  \u003cli\u003eGalvanic Isolation: 1500 VDC (Channel-to-system and channel-to-frame isolation)\u003c\/li\u003e\n  \u003cli\u003eSafe-State Behaviors (FAILOPT): Configurable on a per-channel basis (Hold Last Value or Off\/Safe Value)\u003c\/li\u003e\n  \u003cli\u003eShort-Circuit Protection: Electronic current-limiting circuitry per channel\u003c\/li\u003e\n  \u003cli\u003eOn-board Diagnostics: Extensive module self-diagnostics with fault discrepancy reporting\u003c\/li\u003e\n  \u003cli\u003eConformal Coating: Yes (Standard ISA-S71.04 Class G3 environmental coating protection)\u003c\/li\u003e\n  \u003cli\u003eRedundancy Support: Optional (via specific Redundant Bussed DO IOTA blocks)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TDOB01:\u003c\/strong\u003e Series C Digital Output Bussed Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TDOB11:\u003c\/strong\u003e Series C Digital Output Bussed Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GDOB11:\u003c\/strong\u003e Series C Digital Output Bussed Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GDOB21:\u003c\/strong\u003e Series C Digital Output Bussed Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBussed Power Distribution:\u003c\/strong\u003e Features a group-bussed power design through the IOTA backplane, simplifying field wiring by routing a common 24 V DC supply across channel clusters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFAILOPT Configuration:\u003c\/strong\u003e Supports configurable fail-option parameters defined per channel. If the controller communication drops, channels can be independent set to \u003cem\u003eHOLD LAST VALUE\u003c\/em\u003e or \u003cem\u003eSHED TO SAFE VALUE (OFF)\u003c\/em\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Read-back Verification:\u003c\/strong\u003e Onboard logic continuously reads back the actual electrical state of the output switches and triggers a system alarm if a discrepancy with the commanded logic state is detected.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectronic Short-Circuit Safeguards:\u003c\/strong\u003e Protects internal card components against field wiring faults and shorted solenoids without requiring external inline glass fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSeat the CC-PDOB01 module onto its designated 6-inch non-redundant (CC-TDOB01\/GDOB21) or 12-inch redundant (CC-TDOB11\/GDOB11) IOTA terminal block.\u003c\/li\u003e\n  \u003cli\u003eEnsure that the aggregate current draw of all active field devices connected to the common bus does not exceed the maximum thermal and current load capacity specified for the IOTA board.\u003c\/li\u003e\n  \u003cli\u003eTighten the integrated module mounting fasteners to ensure robust mechanical grounding and electrical backplane continuity.\u003c\/li\u003e\n  \u003cli\u003eDefine specific channel-level FAILOPT parameters and initial state variables in the Experion Control Builder utility prior to downloading the active control strategies to the C300 controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617877942456,"sku":"51405043-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PDOB01r270.png?v=1782201390"},{"product_id":"cc-pfb401-51405044-175-honeywell-4-link-fieldbus-interface-module","title":"CC-PFB401 51405044-175 | Honeywell | 4-Link Fieldbus Interface Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PFB401 51405044-175 is a 4-Link Fieldbus Interface Module (FIM4) engineered for the Experion Series C platform. It acts as an intelligent communication bridge between the C300 controller's Fault Tolerant Ethernet (FTE) layer and up to four independent Foundation Fieldbus H1 links, executing precise peer-to-peer control data scheduling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput \/ Output Model: CC-PFB401 - Fieldbus Interface Module (4-Link)\u003c\/li\u003e\n\u003cli\u003ePart Number: 51405044-175\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eDocument Source: Experion Series-C I\/O Specification (EP03-490-520_V10_SCIO_1_5)\u003c\/li\u003e\n\u003cli\u003eNumber of H1 Links Supported: 4 independent Fieldbus H1 links per module\u003c\/li\u003e\n\u003cli\u003eH1 Link Transmission Speed: 31.25 Kbps (Standard Foundation Fieldbus H1 rate)\u003c\/li\u003e\n\u003cli\u003eDevice Capacity per Link: Up to 16 certified Foundation Fieldbus devices per H1 link\u003c\/li\u003e\n\u003cli\u003eTotal Device Capacity per FIM4: Up to 64 field devices max per module\u003c\/li\u003e\n\u003cli\u003eMacrocycle Execution Support: Fully synchronized with the C300 Control Execution Environment (CEE)\u003c\/li\u003e\n\u003cli\u003eSupply Voltage Rating: 24 V DC nominal (Distributed via Series C IOTA carrier)\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 1500 VDC isolation barrier guarding system logic from field-side transients\u003c\/li\u003e\n\u003cli\u003eConformal Coating: Yes (Standard ISA-S71.04 Class G3 environmental coating protection)\u003c\/li\u003e\n\u003cli\u003eRedundancy Support: Yes (Supports 1:1 Active\/Standby hot-shadowing redundancy)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TFB401:\u003c\/strong\u003e Series C FIM4 Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TFB411:\u003c\/strong\u003e Series C FIM4 Redundant 12” IOTA assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-GFB411:\u003c\/strong\u003e Series C FIM4 Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-GFB421:\u003c\/strong\u003e Series C FIM4 Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the CC-PFB401 module carefully onto its matching 6-inch non-redundant (CC-TFB401) or 12-inch redundant (CC-TFB411) Series C IOTA block interface.\u003c\/li\u003e\n\u003cli\u003eVerify that external Foundation Fieldbus H1 power conditioners are connected downstream on the IOTA loops to properly bias the 31.25 Kbps network lines.\u003c\/li\u003e\n\u003cli\u003eEnsure that correct H1 bus terminators (two 100 Ω resistors in series with a 1 µF capacitor) are active at both physical extremities of each H1 link wire segment to maintain adequate signal amplitude.\u003c\/li\u003e\n\u003cli\u003eConfirm that the module's target redundancy matching configuration is established inside the Experion Control Builder topology prior to completing firmware downloads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617900355768,"sku":"51405044-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PFB401_51405044-175_2.png?v=1782201391"},{"product_id":"cc-pwrr01-51199929-100-honeywell-redundant-power-supply-module","title":"CC-PWRR01 51199929-100 | Honeywell | Redundant Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PWRR01 is a comprehensive 20A Redundant Power System assembly designed for the Experion Series C platform architecture. This complete power solution integrates dual hot-swappable power supply modules, dedicated distribution adapters, and indication cables to deliver regulated, highly reliable 24 V DC power with built-in backup battery charging capabilities for process automation hardware.\u003c\/p\u003e\n\u003ch3\u003eSystem Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Module (2 PCS):\u003c\/strong\u003e Model SPS5713 (Part Number: 51199930-100)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Adapter Board (4 PCS):\u003c\/strong\u003e Model SPS5710-2-LF (Part Number: 51198685-100)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndication Cable (2 PCS):\u003c\/strong\u003e Part Number: 51199935-100\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Component (2 PCS):\u003c\/strong\u003e Part Number: 51202343-001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Component:\u003c\/strong\u003e TDI Power Transistor assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Redundant Power System (20A)\u003c\/li\u003e\n\u003cli\u003eModel Code: CC-PWRR01\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range: 100-230 V AC nominal (Sustains standard 120\/240 V AC utility lines)\u003c\/li\u003e\n\u003cli\u003eInput Frequency Range: 47-63 Hz\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Range: 24-26 V DC regulated\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current: 20 A\u003c\/li\u003e\n\u003cli\u003eHold-up Time \/ Holdup: 20 ms\u003c\/li\u003e\n\u003cli\u003eBattery Charging Specifications: 30 minutes maximum recovery time at 20A maximum current load\u003c\/li\u003e\n\u003cli\u003eBattery Capacity Support Range: 30 to 100 Ah\u003c\/li\u003e\n\u003cli\u003ePower Supply Efficiency: 65% (minimum)\u003c\/li\u003e\n\u003cli\u003eCustoms Tariff Number (HS Code): 8537101190\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003ePhysical Dimensions: 7.3 cm x 15.5 cm x 16.5 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the primary TDI Power Transistor chassis into the specified frame slot before installing the dual SPS5713 power supply modules.\u003c\/li\u003e\n\u003cli\u003eInterface the 4 pieces of SPS5710-2-LF power adapter boards to the backplane distribution rails to split output current legs cleanly.\u003c\/li\u003e\n\u003cli\u003eConnect the 51199935-100 indication cables to their corresponding diagnostic headers to ensure full status reporting across the Experion network framework.\u003c\/li\u003e\n\u003cli\u003eVerify that external battery backup packs align with the supported 30 to 100 Ah storage threshold before enabling the rapid charging circuit loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617989484728,"sku":"CC-PWRR01","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PWRR01r270.png?v=1782204475"},{"product_id":"honeywell-cc-taim01-51305959-175-pmio-ll-mux-iota","title":"Honeywell CC-TAIM01 51305959-175 PMIO LL Mux IOTA","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell PMIO LL Mux IOTA (Low Level Analog Input Multiplexer Input Output Termination Assembly) is a highly reliable terminal base designed to interface low-level field sensors—primarily thermocouples (TC) and resistance temperature detectors (RTD)—with the Honeywell Process Manager Input\/Output (PMIO) and Experion systems. It acts as the physical wiring termination point, embedding specialized multiplexing circuitry to route high-density temperature data down to a centralized control module.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Low Level Analog Input Multiplexer Termination Assembly (LLMux IOTA \/ FTA)\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eSystem Architecture: PMIO \/ Experion Series C (via integration adapters)\u003c\/li\u003e\n\u003cli\u003eSupported Input Signals: Thermocouples (Type J, K, T, E, R, S, B, N) and Millivolt (mV) sources, RTDs (2-wire, 3-wire, 4-wire Pt100 \/ Cu10)\u003c\/li\u003e\n\u003cli\u003eChannel Density Capacity: 16 channels per base card block (expandable up to 64 channels total via multi-card cascading configurations)\u003c\/li\u003e\n\u003cli\u003eCommon Mode Rejection Ratio (CMRR): 120 dB minimum at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eNormal Mode Rejection Ratio (NMRR): 60 dB minimum at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 1500 VDC fully isolated signal paths protecting internal control tier buses from field transients\u003c\/li\u003e\n\u003cli\u003eOpen Thermocouple Detection (OTD): Integrated hardware-driven continuous broken-wire verification cycles\u003c\/li\u003e\n\u003cli\u003eCold Junction Compensation (CJC): High-accuracy onboard solid-state temperature reference sensors for precise thermocouple tracking\u003c\/li\u003e\n\u003cli\u003eConformal Coating: Available (Class G3 environmental protection option matching ISA-S71.04 standards)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Interconnect Subsystems\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy PMIO Multiplexer FTAs:\u003c\/strong\u003e MU-TAMR04 (RTD boards), MU-TAMT04, and MU-TAMT14 (Thermocouple\/mV boards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries C Adapter System:\u003c\/strong\u003e Connects to the Series C LLMux IOTA (such as CC-TAIM01) and IOM electronics through the dedicated \u003cstrong\u003eCC-PCF901 \/ CC-PCF091\u003c\/strong\u003e cable adapter linkage across distances up to 1000 feet.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53618000887992,"sku":"51305959-175","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-TAIM01_3r270.png?v=1782204522"},{"product_id":"honeywell-cc-taix01-51308363-175-analog-input-module-termination-assembly","title":"Honeywell CC-TAIX01 51308363-175 Analog Input Module Termination Assembly","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TAIX01 (Part Number: 51308363-175) is a high-density, non-redundant Analog Input Termination Assembly (IOTA) engineered for the Experion PKS Series C I\/O architecture. This 6-inch terminal base provides the dedicated physical screw-terminal wiring paths and electrical interface to distribute loop power and route field transmitter signals into the companion input modules.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Analog Input Module Termination Assembly (IOTA)\u003c\/li\u003e\n\u003cli\u003eModel Code: CC-TAIX01\u003c\/li\u003e\n\u003cli\u003ePart Number: 51308363-175\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell (Discontinued by Manufacturer)\u003c\/li\u003e\n\u003cli\u003eSupply Voltage Rating: 24 V DC nominal\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption \/ Draw: 0.195 A maximum\u003c\/li\u003e\n\u003cli\u003eChannel Density Capacity: 16 channels\u003c\/li\u003e\n\u003cli\u003eSignal Type Compatibility: High-Level Analog Inputs (4-20 mA \/ 1-5 V DC)\u003c\/li\u003e\n\u003cli\u003eIOTA Physical Footprint Size: 6 inches\u003c\/li\u003e\n\u003cli\u003ePhysical Dimensions: 14.5 cm x 12.0 cm x 6.5 cm\u003c\/li\u003e\n\u003cli\u003eProduct Net Weight: 0.24 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the CC-TAIX01 base block assembly directly onto the standard carrier DIN rail channel within the environmental cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure that total field loop currents routed through the common termination tracks remain fully balanced and do not exceed the nominal 0.195 A current limits.\u003c\/li\u003e\n\u003cli\u003eVerify that the alignment guide rails are clean and free of debris before lowering the active analog input module onto the IOTA multi-point socket interface.\u003c\/li\u003e\n\u003cli\u003eSecure the structural frame grounding connection from the baseplate directly back to the enclosure master system common ground bus bar to maintain clean noise rejection margins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53618003902648,"sku":"51308363-175","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-TAIX01_2.png?v=1782204528"},{"product_id":"51308365-175-honeywell-cc-taix11-redundant-analog-input-iota","title":"51308365-175 | Honeywell CC-TAIX11 Redundant Analog Input IOTA","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TAIX11 (Part Number: 51308365-175) is a 12-inch Redundant Analog Input Termination Assembly (IOTA) designed for the Experion PKS Series C platform. It provides dual-slot mounting to host two analog input modules in a 1:1 hot-shadowing redundant configuration, ensuring uninterrupted process signal routing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Redundant Analog Input Module Termination Assembly\u003c\/li\u003e\n\u003cli\u003eModel Code: CC-TAIX11\u003c\/li\u003e\n\u003cli\u003ePart Number: 51308365-175\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eChannel Capacity: 16 Channels\u003c\/li\u003e\n\u003cli\u003eSignal Compatibility: High-Level Analog Inputs (4-20 mA \/ 1-5 V DC)\u003c\/li\u003e\n\u003cli\u003eIOTA Size: 12 inches\u003c\/li\u003e\n\u003cli\u003eRedundancy Support: Yes (Dual 1:1 Active\/Standby slots)\u003c\/li\u003e\n\u003cli\u003eIsolation Barrier: 1500 VDC\u003c\/li\u003e\n\u003cli\u003eConformal Coating: Yes (ISA-S71.04 Class G3 Compliant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the 12-inch CC-TAIX11 IOTA vertically onto the cabinet DIN rail carrier.\u003c\/li\u003e\n\u003cli\u003eConnect the enclosure's master grounding bus directly to the IOTA grounding strip to maintain clean signal noise margins.\u003c\/li\u003e\n\u003cli\u003eWire the 16 analog field loops to the screw terminal blocks according to designated polarities.\u003c\/li\u003e\n\u003cli\u003eInspect all connector pins on both input modules for alignment before inserting them straight into the primary and backup slots.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53618004459704,"sku":"51308365-175","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-TAIX61_1__r270.png?v=1782204502"},{"product_id":"honeywell-cc-taix61-51307077-175-6-inch-high-level-analog-input-iota","title":"Honeywell CC-TAIX61 51307077-175 6-inch High-Level Analog Input IOTA","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TAIX61 (Part Number: 51307077-175) is a 6-inch High-Level Analog Input Termination Assembly (IOTA) with integrated HART capability designed for the Experion PKS Series C platform. It serves as the physical interface to route 16 analog field signals into the corresponding input module while enabling digital HART protocol communication.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: HART Analog Input Module Termination Assembly\u003c\/li\u003e\n\u003cli\u003eModel Code: CC-TAIX61\u003c\/li\u003e\n\u003cli\u003ePart Number: 51307077-175\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eChannel Capacity: 16 Channels\u003c\/li\u003e\n\u003cli\u003eSignal Compatibility: High-Level Analog Inputs (4-20 mA \/ 1-5 V DC) with HART support\u003c\/li\u003e\n\u003cli\u003eIOTA Size: 6 inches\u003c\/li\u003e\n\u003cli\u003eRedundancy Support: No (Non-Redundant \/ Single slot layout)\u003c\/li\u003e\n\u003cli\u003eConformal Coating: Yes (ISA-S71.04 Class G3 Compliant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the CC-TAIX61 IOTA firmly onto the designated carrier DIN rail inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect the IOTA grounding strip directly to the enclosure's master common ground bar to prevent electrical noise on the 4-20 mA and HART data paths.\u003c\/li\u003e\n\u003cli\u003eWire the 16 analog transmitter loops to the screw terminals, ensuring proper loop power sourcing.\u003c\/li\u003e\n\u003cli\u003eCheck the multi-pin connector on the analog input module for bent pins before pressing it vertically onto the board interface slot.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53618006655160,"sku":"51307077-175","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-TAIX61r270.png?v=1782204517"},{"product_id":"honeywell-cc-tdil01-51308386-175-digital-input-termination-assembly-iota","title":"Honeywell CC-TDIL01 51308386-175 Digital Input Termination Assembly (IOTA)","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TDIL01 (Part Number: 51308386-175) is a high-density, 6-inch Non-Redundant Digital Input Termination Assembly (IOTA) designed for the Experion PKS Series C platform. It functions as the physical wiring hub to receive digital (on\/off) signals from critical field devices—such as sensors and switches—and communicates them reliably to the Experion DCS.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Digital Input Module Termination Assembly (IOTA)\u003c\/li\u003e\n\u003cli\u003eModel Code: CC-TDIL01\u003c\/li\u003e\n\u003cli\u003ePart Number: 51308386-175\u003c\/li\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eChannel Capacity: 32 Channels\u003c\/li\u003e\n\u003cli\u003eSignal Type Compatibility: 24 V DC Discrete Signals (Dry contact \/ Sinking topology)\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range: 18 to 30 V DC\u003c\/li\u003e\n\u003cli\u003eON State Threshold (Minimum): 13 V DC or 3 mA\u003c\/li\u003e\n\u003cli\u003eOFF State Threshold (Maximum): 5 V DC or 1.2 mA\u003c\/li\u003e\n\u003cli\u003eHardware Debounce Filter: 5 ms ± 20%\u003c\/li\u003e\n\u003cli\u003eChannel Isolation: Optical isolation (embedded inside the Input Output Module \/ IOM)\u003c\/li\u003e\n\u003cli\u003ePrimary Processing Mode: Continuous Input Channel Scanning (PV execution)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhysical Dimensions: 22.0 cm x 12.0 cm x 6.8 cm\u003c\/li\u003e\n\u003cli\u003eProduct Net Weight: 0.38 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the CC-TDIL01 IOTA vertically onto a standard cabinet DIN rail layout.\u003c\/li\u003e\n\u003cli\u003eEnsure the system loop power grid supplies steady voltage within the specified 18 to 30 V DC operational limits.\u003c\/li\u003e\n\u003cli\u003eBond the integrated IOTA chassis grounding trace directly to the enclosure's master common ground bar to guarantee stable electrical noise margins.\u003c\/li\u003e\n\u003cli\u003eVerify that the matching 32-channel digital input module connector pins are straight and clean before snapping the electronics onto the board's socket interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53618007081144,"sku":"51308386-175","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-TDIL01_2__r270.png?v=1782204498"},{"product_id":"honeywell-tdc-3000-51400604-100-5-slot-module-rack-chassis","title":"Honeywell TDC 3000 51400604-100 5-Slot Module Rack Chassis","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400604-100\u003c\/strong\u003e is a \u003cstrong\u003e5-Slot Module Rack Chassis\u003c\/strong\u003e engineered for the Honeywell TDC 3000 and TotalPlant Solution (TPS) Distributed Control Systems (DCS). It provides the physical infrastructure and high-speed backplane connectivity required for Process Managers (PM), Advanced Process Managers (APM), and specialized interface cards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400604-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 5-Slot Module Rack \/ Chassis File\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS, PM, APM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Capacity:\u003c\/strong\u003e 5 Universal Module Slots\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Function:\u003c\/strong\u003e Data bus and power distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 19-inch rack-mount or panel-mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Rails:\u003c\/strong\u003e +5V, +12V DC via system power cables\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Industrial-grade metal, EMI\/RFI shielded\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (32°F to 140°F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil refineries and petrochemical plants\u003c\/li\u003e\n  \u003cli\u003eChemical processing facilities\u003c\/li\u003e\n  \u003cli\u003ePower generation control nodes\u003c\/li\u003e\n  \u003cli\u003eLegacy Honeywell DCS retrofits and expansions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What modules can be installed in this chassis?\u003c\/strong\u003e\u003cbr\u003eA: The 5 universal slots accept PM, APM, communication, and I\/O interface modules designed for the TDC 3000\/TPS backplane architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this chassis CE compliant?\u003c\/strong\u003e\u003cbr\u003eA: It meets industrial EMC and safety standards for process control equipment. Verify specific regional certifications with your local Honeywell representative.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this chassis for redundant controller configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the backplane supports redundant PM\/APM pairs when populated with the appropriate redundancy driver modules.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount the chassis in a standard 19-inch industrial cabinet using the provided brackets.\u003c\/li\u003e\n  \u003cli\u003eConnect system power cables to the backplane power input terminals.\u003c\/li\u003e\n  \u003cli\u003eInstall modules starting from the leftmost slot, ensuring proper alignment with the backplane connectors.\u003c\/li\u003e\n  \u003cli\u003eSecure each module with the retaining screws to prevent vibration-induced disconnections.\u003c\/li\u003e\n  \u003cli\u003eVerify power rail voltages (+5V, +12V) before energizing connected modules.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm your existing system uses the TDC 3000 or TPS architecture before ordering.\u003c\/li\u003e\n  \u003cli\u003eFor larger I\/O counts, consider the 10-slot chassis variant (e.g., 51400919-100 series).\u003c\/li\u003e\n  \u003cli\u003eAlways pair with an appropriate power supply module rated for the total slot load.\u003c\/li\u003e\n  \u003cli\u003eCheck module revision levels to ensure backplane compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831021494456,"sku":"51400604-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400604-100r180.png?v=1785223344"},{"product_id":"honeywell-tdc-3000-51400646-100-5-slot-chassis-fan-assembly","title":"Honeywell TDC 3000 51400646-100 5-Slot Chassis Fan Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400646-100\u003c\/strong\u003e is a \u003cstrong\u003e5-Slot Chassis Fan Assembly\u003c\/strong\u003e (Revision F) designed for the Honeywell TDC 3000 distributed control system. It provides active cooling for modules installed in the 5-slot chassis, ensuring reliable thermal management in continuous process control environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400646-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fan Assembly \/ Cooling Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000 5-Slot Chassis\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRevision:\u003c\/strong\u003e Rev F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Active thermal management for chassis-mounted modules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Process control cabinets in refineries, chemical plants, power generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTDC 3000 control cabinet cooling\u003c\/li\u003e\n  \u003cli\u003eLegacy DCS infrastructure maintenance\u003c\/li\u003e\n  \u003cli\u003eHot-standby redundancy systems requiring continuous airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this fan assembly compatible with all 5-slot chassis?\u003c\/strong\u003e\u003cbr\u003eA: It is designed specifically for the Honeywell TDC 3000 5-slot chassis series. Verify chassis part number before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How often should the fan assembly be replaced?\u003c\/strong\u003e\u003cbr\u003eA: Inspect annually in high-duty cycles; typical service life is 5–7 years depending on ambient temperature and dust exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this include the fan housing and mounting hardware?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it ships as a complete assembly. Mounting hardware is typically included or reused from the existing chassis.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eDe-energize the chassis and verify zero energy state.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing fan assembly by releasing the retaining clips or screws.\u003c\/li\u003e\n  \u003cli\u003eDisconnect the fan power connector from the chassis backplane.\u003c\/li\u003e\n  \u003cli\u003eInstall the new 51400646-100 assembly, ensuring proper airflow direction (check arrow marking).\u003c\/li\u003e\n  \u003cli\u003eReconnect power and verify fan operation before closing the cabinet.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMatch the revision level (Rev F) to your chassis specifications.\u003c\/li\u003e\n  \u003cli\u003eFor dual-fan redundancy, consider the 51400764-100 Dual Fan Module.\u003c\/li\u003e\n  \u003cli\u003eEnsure cabinet intake filters are clean to maximize fan life.\u003c\/li\u003e\n  \u003cli\u003eStock a spare unit for critical process control applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831023657144,"sku":"51400646-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400646-100_2.png?v=1785223350"},{"product_id":"51400667-100-honeywell-tdc-3000-enhanced-lcn-20-interface-board","title":"51400667-100 Honeywell TDC 3000 Enhanced LCN 20 Interface Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400667-100\u003c\/strong\u003e is an \u003cstrong\u003eEnhanced LCN 20 Interface Board\u003c\/strong\u003e for the Honeywell TDC 3000 distributed control system. It serves as the communication gateway between the Local Control Network (LCN) and connected process control modules, enabling deterministic data exchange across the DCS architecture.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400667-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e LCN 20 Interface \/ Communication Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork:\u003c\/strong\u003e Local Control Network (LCN)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e LCN communication and node interface\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e PC Board for chassis installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLCN node communication in TDC 3000 systems\u003c\/li\u003e\n  \u003cli\u003eDCS network expansion and retrofit projects\u003c\/li\u003e\n  \u003cli\u003eIntegration of process managers with operator stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 51400667-100 and 51400668-100?\u003c\/strong\u003e\u003cbr\u003eA: The 51400667-100 is the LCN interface board, while the 51400668-100 is the WDC 20 Controller Module. They work together but serve different functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board be used in redundant LCN configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports redundant LCN architectures when paired with appropriate redundancy modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is firmware upgrading required?\u003c\/strong\u003e\u003cbr\u003eA: Check the current system firmware revision; some LCN boards may require matching firmware levels for proper communication.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the chassis and wear an ESD wrist strap.\u003c\/li\u003e\n  \u003cli\u003eInsert the 51400667-100 board into the designated LCN slot.\u003c\/li\u003e\n  \u003cli\u003eSecure the board with retaining screws.\u003c\/li\u003e\n  \u003cli\u003eConnect LCN coaxial or fiber cables per the TDC 3000 wiring manual.\u003c\/li\u003e\n  \u003cli\u003ePower up and verify LCN node status via the system diagnostic display.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify your LCN topology (coaxial vs. fiber) before ordering cable accessories.\u003c\/li\u003e\n  \u003cli\u003eConfirm chassis slot availability; LCN boards typically require specific slot positions.\u003c\/li\u003e\n  \u003cli\u003eFor enhanced performance, pair with the 51400668-100 WDC controller.\u003c\/li\u003e\n  \u003cli\u003eDocument node addresses before replacement to simplify reconfiguration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831023755448,"sku":"51400667-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400667-100.png?v=1785223360"},{"product_id":"51400668-100-honeywell-tdc-3000-wdc-20-controller-module","title":"51400668-100 Honeywell TDC 3000 WDC 20 Controller Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400668-100\u003c\/strong\u003e is a \u003cstrong\u003eWDC 20 Controller Module\u003c\/strong\u003e \/ PC Controller Module Board designed for the Honeywell TDC 3000 distributed control system. It provides high-speed control logic execution and network communication for demanding industrial process environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400668-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e WDC 20 Controller \/ PC Controller Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Honeywell Local Control Network (LCN)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e High-performance CPU for real-time control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 32 MB RAM, 64 MB Flash Storage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120 × 80 × 60 mm (4.7 × 3.1 × 2.4 in)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.98 lbs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C (32°F to 122°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReal-time process control in chemical plants and refineries\u003c\/li\u003e\n  \u003cli\u003ePower generation facility automation\u003c\/li\u003e\n  \u003cli\u003eLegacy Honeywell DCS logic execution and network nodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module replace a rack chassis or fan assembly?\u003c\/strong\u003e\u003cbr\u003eA: No. The 51400668-100 is a dedicated controller module for logic execution and LCN communication. Chassis and cooling components are separate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What environments is it suitable for?\u003c\/strong\u003e\u003cbr\u003eA: It is designed for industrial conditions including high-temperature and vibration-tolerant applications. Ensure proper voltage supply and cabinet cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there similar modules for comparison?\u003c\/strong\u003e\u003cbr\u003eA: Comparable modules include the 51400667-100 LCN Interface Board and 51400901-100 EMPU CPU. Each serves a distinct role in the DCS architecture.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify chassis power is off and ESD precautions are in place.\u003c\/li\u003e\n  \u003cli\u003eAlign the module with the backplane connector in the designated controller slot.\u003c\/li\u003e\n  \u003cli\u003eApply even pressure to seat the module fully.\u003c\/li\u003e\n  \u003cli\u003eSecure with retaining screws and connect any required LCN cables.\u003c\/li\u003e\n  \u003cli\u003eApply power and monitor the controller status LEDs for normal operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm your application requires WDC-level processing; for enhanced performance consider the EMPU (51400901-100).\u003c\/li\u003e\n  \u003cli\u003eEnsure adequate cabinet ventilation to prevent thermal throttling.\u003c\/li\u003e\n  \u003cli\u003eVerify LCN node address configuration before installation.\u003c\/li\u003e\n  \u003cli\u003eKeep a spare controller on-site for critical process loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831025787064,"sku":"51400668-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400668-100.png?v=1785223356"},{"product_id":"honeywell-tdc-3000-51400700-100-dhi-board","title":"Honeywell TDC 3000 51400700-100 DHI Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400700-100\u003c\/strong\u003e is a \u003cstrong\u003eDHI Data Highway Interface Board\u003c\/strong\u003e for the Honeywell TDC 3000 distributed control system. It enables communication between the TDC 3000 system and the Honeywell Data Highway, facilitating integration with legacy process control networks and host systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400700-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Data Highway Interface \/ Communication Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork:\u003c\/strong\u003e Honeywell Data Highway (DHI)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Data highway communication and protocol bridging\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e Data Control Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTDC 3000 Data Highway integration\u003c\/li\u003e\n  \u003cli\u003eHost computer and PLC communication links\u003c\/li\u003e\n  \u003cli\u003eLegacy system retrofit and expansion projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What network does this board interface with?\u003c\/strong\u003e\u003cbr\u003eA: The 51400700-100 interfaces with the Honeywell Data Highway (DHI), a legacy peer-to-peer communication network used in TDC 3000 systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this board required for all TDC 3000 systems?\u003c\/strong\u003e\u003cbr\u003eA: It is only required if your architecture includes Data Highway communication. Pure LCN\/UCN systems may not need it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board be used for Modbus or Ethernet?\u003c\/strong\u003e\u003cbr\u003eA: No, this is specifically for the Honeywell Data Highway protocol. For Modbus or Ethernet, use the appropriate gateway or communication module.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the chassis and observe ESD protocols.\u003c\/li\u003e\n  \u003cli\u003eInstall the board in the appropriate chassis slot.\u003c\/li\u003e\n  \u003cli\u003eConnect Data Highway coaxial cables to the board terminals.\u003c\/li\u003e\n  \u003cli\u003eConfigure Data Highway node addresses per the TDC 3000 configuration manual.\u003c\/li\u003e\n  \u003cli\u003ePower up and verify communication status via system diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that your system architecture actually uses the Honeywell Data Highway.\u003c\/li\u003e\n  \u003cli\u003eCheck cable type (coaxial) and termination requirements before installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure no duplicate node addresses exist on the Data Highway segment.\u003c\/li\u003e\n  \u003cli\u003eConsider upgrading to UCN\/LCN architectures for new installations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831026671800,"sku":"51400700-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400700-100_3.png?v=1785223361"},{"product_id":"honeywell-tdc-3000-51400764-100-dual-fan-module","title":"Honeywell TDC 3000 51400764-100 Dual Fan Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400764-100\u003c\/strong\u003e is a \u003cstrong\u003eDual Fan Module\u003c\/strong\u003e designed for Honeywell TDC 3000 distributed control systems. It provides redundant active cooling for control cabinets, ensuring continuous thermal management even if one fan fails.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400764-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Dual Fan Module \/ Cooling Assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFan Configuration:\u003c\/strong\u003e Dual redundant fans\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Active cooling and thermal management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTDC 3000 control cabinet cooling\u003c\/li\u003e\n  \u003cli\u003eHigh-availability redundant cooling systems\u003c\/li\u003e\n  \u003cli\u003eCritical process control environments requiring continuous operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 51400646-100 and 51400764-100?\u003c\/strong\u003e\u003cbr\u003eA: The 51400646-100 is a single fan assembly for 5-slot chassis, while the 51400764-100 is a dual fan module offering redundant cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the dual fan module provide alarm output on failure?\u003c\/strong\u003e\u003cbr\u003eA: Most Honeywell dual fan modules include tachometer or thermal alarm contacts. Verify specific wiring with the installation manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I replace a single fan in the dual module?\u003c\/strong\u003e\u003cbr\u003eA: It is recommended to replace the entire module to maintain balanced airflow and warranty coverage.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eDe-energize the cabinet and lock out\/tag out power sources.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing fan module by releasing the mounting brackets.\u003c\/li\u003e\n  \u003cli\u003eDisconnect power and alarm wiring from the old module.\u003c\/li\u003e\n  \u003cli\u003eInstall the 51400764-100 module, ensuring proper airflow orientation.\u003c\/li\u003e\n  \u003cli\u003eReconnect power and alarm wiring, then verify both fans operate.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChoose the dual fan module for critical applications where single-fan failure cannot be tolerated.\u003c\/li\u003e\n  \u003cli\u003eVerify cabinet dimensions to ensure the dual module fits your enclosure.\u003c\/li\u003e\n  \u003cli\u003eMonitor fan vibration and noise levels as early indicators of bearing wear.\u003c\/li\u003e\n  \u003cli\u003eMaintain spare filters to prevent dust buildup on fan blades.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831026999480,"sku":"51400764-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400764-100_1__.r180.png?v=1785223322"},{"product_id":"honeywell-51400855-100-sio-trend-board","title":"Honeywell 51400855-100 SIO Trend Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400855-100\u003c\/strong\u003e is an \u003cstrong\u003eSIO Trend Board\u003c\/strong\u003e (also known as Trend Pen Board, Revision L) for the Honeywell TDC 3000 distributed control system. It handles system-level trend data acquisition and display generation, supporting historical data logging and real-time process variable trending for operator stations.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400855-100\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e SIO Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision:\u003c\/strong\u003e Rev L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e 115 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Trend data handling and display generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e Trend SIO Board, Trend Pen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time process variable trending\u003c\/li\u003e\n\u003cli\u003eHistorical data logging and retrieval\u003c\/li\u003e\n\u003cli\u003eOperator station display support\u003c\/li\u003e\n\u003cli\u003eProcess optimization and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this board store trend data locally?\u003c\/strong\u003e\u003cbr\u003eA: The SIO board handles trend data acquisition and buffering; long-term storage typically resides on the system history module or external storage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this board required for all operator stations?\u003c\/strong\u003e\u003cbr\u003eA: It is required for stations configured to display real-time and historical trends. Basic operator stations without trending may not need it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What revision should I order?\u003c\/strong\u003e\u003cbr\u003eA: Rev L is the most commonly available revision. Verify compatibility with your system software revision before ordering.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the operator station chassis.\u003c\/li\u003e\n\u003cli\u003eInstall the 51400855-100 board in the designated SIO slot.\u003c\/li\u003e\n\u003cli\u003eConnect 115 VAC power if required (verify wiring diagram).\u003c\/li\u003e\n\u003cli\u003eConfigure trend parameters via the TDC 3000 configuration tools.\u003c\/li\u003e\n\u003cli\u003ePower up and verify trend display functionality on the operator console.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm your operator station software supports the SIO Trend Board revision.\u003c\/li\u003e\n\u003cli\u003eFor systems with heavy trending requirements, verify memory and processing capacity.\u003c\/li\u003e\n\u003cli\u003eEnsure proper 115 VAC grounding to prevent noise interference on trend data.\u003c\/li\u003e\n\u003cli\u003eBack up existing trend configurations before replacing the board.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831027163320,"sku":"51400855-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400855-100_3.png?v=1785223352"},{"product_id":"51400901-100-honeywell-enhanced-cpu-processor-module","title":"51400901-100 | Honeywell Enhanced CPU Processor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400901-100\u003c\/strong\u003e is an \u003cstrong\u003eEMPU CPU Board\u003c\/strong\u003e (Enhanced Main Processing Unit CPU) for the Honeywell TDC 3000 distributed control system. It serves as the primary processor for enhanced operator stations and advanced control nodes, delivering high-performance computation and LCN communication.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400901-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EMPU CPU \/ Processor Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Enhanced main processing and LCN node control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e PWB, EMPU CPU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnhanced operator station processing\u003c\/li\u003e\n  \u003cli\u003eAdvanced process control computation\u003c\/li\u003e\n  \u003cli\u003eLCN network node management\u003c\/li\u003e\n  \u003cli\u003eHigh-performance DCS controller upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between EMPU and standard CPU modules?\u003c\/strong\u003e\u003cbr\u003eA: The EMPU (Enhanced Main Processing Unit) offers higher processing capacity and expanded memory for demanding applications compared to standard CPU boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this board include onboard memory?\u003c\/strong\u003e\u003cbr\u003eA: The EMPU CPU typically works with companion memory boards such as the 51400910-100 EMEM for expanded storage capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this replace older WDC or MCPU modules?\u003c\/strong\u003e\u003cbr\u003eA: It may be used in upgraded configurations, but verify software compatibility and chassis slot requirements with your system documentation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the chassis is powered off and ESD protection is active.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing CPU board if upgrading.\u003c\/li\u003e\n  \u003cli\u003eAlign the 51400901-100 EMPU board with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003ePress firmly to seat the board and secure with retaining screws.\u003c\/li\u003e\n  \u003cli\u003eInstall companion memory boards (e.g., EMEM) if required.\u003c\/li\u003e\n  \u003cli\u003ePower up and load the appropriate system firmware.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify your system software revision supports the EMPU processor.\u003c\/li\u003e\n  \u003cli\u003ePair with the 51400910-100 EMEM board for maximum performance.\u003c\/li\u003e\n  \u003cli\u003eCheck if your application requires the enhanced processing capabilities of EMPU vs. standard CPU.\u003c\/li\u003e\n  \u003cli\u003eDocument existing CPU configuration before replacement for easier restoration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831027294392,"sku":"51400901-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400901-100_2_r180.png?v=1785223355"},{"product_id":"51400910-100-honeywell-emem-1mw-memory-board","title":"51400910-100 | Honeywell EMEM 1MW Memory Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400910-100\u003c\/strong\u003e is an \u003cstrong\u003eEMEM 1MW Memory Board\u003c\/strong\u003e (Enhanced Memory, 1 Megaword) for the Honeywell TDC 3000 distributed control system. It provides expanded memory capacity for EMPU CPU boards and enhanced operator stations, supporting larger process databases and historical data storage.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400910-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EMEM Memory Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e 1 MW (Megaword)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Expanded memory for EMPU and enhanced stations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e PWB, EMEM 1MW\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnhanced operator station memory expansion\u003c\/li\u003e\n  \u003cli\u003eLarge process database storage\u003c\/li\u003e\n  \u003cli\u003eHistorical data and trend buffering\u003c\/li\u003e\n  \u003cli\u003eEMPU CPU memory complement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this board compatible with all TDC 3000 CPU boards?\u003c\/strong\u003e\u003cbr\u003eA: It is designed primarily for EMPU CPU configurations. Verify compatibility with your specific CPU model before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can multiple EMEM boards be installed for additional memory?\u003c\/strong\u003e\u003cbr\u003eA: System limitations apply; consult the TDC 3000 hardware manual for maximum memory configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does memory content persist after power loss?\u003c\/strong\u003e\u003cbr\u003eA: The EMEM board uses volatile memory; ensure battery backup or UPS protection for critical data retention.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the chassis and discharge static electricity.\u003c\/li\u003e\n  \u003cli\u003eLocate the memory expansion slot adjacent to the EMPU CPU.\u003c\/li\u003e\n  \u003cli\u003eInsert the 51400910-100 board carefully into the slot.\u003c\/li\u003e\n  \u003cli\u003eSecure the board and verify proper seating.\u003c\/li\u003e\n  \u003cli\u003ePower up and confirm memory recognition in system diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePair with the 51400901-100 EMPU CPU for optimal performance.\u003c\/li\u003e\n  \u003cli\u003eAssess your process database size to determine if 1 MW is sufficient.\u003c\/li\u003e\n  \u003cli\u003eFor larger memory requirements, consider the QMEM series (e.g., 51401072-300).\u003c\/li\u003e\n  \u003cli\u003eEnsure battery backup is functional to protect memory contents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831027523768,"sku":"51400910-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400910-100r180.png?v=1785223318"},{"product_id":"51400926-100-honeywell-enhanced-pdg-board","title":"51400926-100 | Honeywell Enhanced PDG Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400926-100\u003c\/strong\u003e is an \u003cstrong\u003eEnhanced Peripheral Display Generator (ENH PDG) Board\u003c\/strong\u003e for the Honeywell TDC 3000 distributed control system. It generates high-resolution display outputs for operator consoles, supporting process graphics, alarm summaries, and trend displays.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400926-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Enhanced PDG \/ Display Generator Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Peripheral display generation and video output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e PWB, ENH PDG (also cross-referenced to 51401286-100)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOperator console display generation\u003c\/li\u003e\n  \u003cli\u003eProcess graphic rendering\u003c\/li\u003e\n  \u003cli\u003eAlarm and event display output\u003c\/li\u003e\n  \u003cli\u003eTrend and report visualization\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PDG and EPDG?\u003c\/strong\u003e\u003cbr\u003eA: PDG (Peripheral Display Generator) is the base version; EPDG (Enhanced PDG) and ENH PDG offer improved resolution and faster refresh rates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this board compatible with both CRT and flat-panel displays?\u003c\/strong\u003e\u003cbr\u003eA: The ENH PDG supports standard video outputs. Adapter cables may be required for modern flat-panel displays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use 51401286-100 as a substitute?\u003c\/strong\u003e\u003cbr\u003eA: The 51401286-100 is listed as an EPDG Interface Card and may be functionally similar. Verify compatibility with your console model.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the operator console and chassis.\u003c\/li\u003e\n  \u003cli\u003eInstall the 51400926-100 board in the PDG slot.\u003c\/li\u003e\n  \u003cli\u003eConnect video output cables to the console display.\u003c\/li\u003e\n  \u003cli\u003eConfigure display parameters via the TDC 3000 setup utility.\u003c\/li\u003e\n  \u003cli\u003ePower up and verify display output quality and resolution.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify your console display type (CRT vs. LCD) for proper cable selection.\u003c\/li\u003e\n  \u003cli\u003eCheck display resolution requirements before choosing between PDG and ENH PDG.\u003c\/li\u003e\n  \u003cli\u003eFor dual-display consoles, confirm the board supports multiple video outputs.\u003c\/li\u003e\n  \u003cli\u003eUpdate display drivers\/firmware to match the ENH PDG revision.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831030145208,"sku":"51400926-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400926-100_2.png?v=1785223358"},{"product_id":"51400955-100-honeywell-process-network-interface-board","title":"51400955-100 | Honeywell Process Network Interface Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51400955-100\u003c\/strong\u003e is a \u003cstrong\u003ePNI (Processing Node Interface) Board\u003c\/strong\u003e for the Honeywell TDC 3000 distributed control system. It serves as the interface between processing nodes and the system backplane, managing data exchange and node addressing for distributed control applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 51400955-100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PNI \/ Processing Node Interface Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell TDC 3000, TPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Processing node interface and backplane communication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e PWB, PNI\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcessing node backplane interface\u003c\/li\u003e\n  \u003cli\u003eDistributed control node management\u003c\/li\u003e\n  \u003cli\u003eSystem expansion and retrofit projects\u003c\/li\u003e\n  \u003cli\u003eRedundant node configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does PNI stand for?\u003c\/strong\u003e\u003cbr\u003eA: PNI stands for Processing Node Interface. It bridges processing modules with the system backplane and network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the PNI board required for every processing node?\u003c\/strong\u003e\u003cbr\u003eA: Yes, each processing node typically requires its own PNI board for proper backplane communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board be used in redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, PNI boards support redundant node setups when paired with appropriate redundancy hardware.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the chassis and observe ESD safety.\u003c\/li\u003e\n  \u003cli\u003eInstall the 51400955-100 board in the designated PNI slot.\u003c\/li\u003e\n  \u003cli\u003eConnect backplane and network cables per the wiring diagram.\u003c\/li\u003e\n  \u003cli\u003eConfigure node addresses using the system configuration tools.\u003c\/li\u003e\n  \u003cli\u003ePower up and verify node communication via diagnostic utilities.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm the number of processing nodes in your system to order the correct quantity.\u003c\/li\u003e\n  \u003cli\u003eVerify node address availability before installation.\u003c\/li\u003e\n  \u003cli\u003eFor redundant nodes, order PNI boards in pairs.\u003c\/li\u003e\n  \u003cli\u003eEnsure firmware compatibility between PNI and processing modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53831033225400,"sku":"51400955-100","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/51400955-100_3__..png?v=1785223315"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/honeywell-series-8-i-o-c300-controller.oembed?page=2","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}