{"title":"Prosoft","description":"\u003cp\u003eProSoft Technology specializes in bridging the communication gap between different industrial automation platforms. This collection features high-performance protocol gateways, wireless bridges, and in-rack modules designed to allow seamless data exchange between Rockwell Automation, Schneider Electric, and Siemens systems. Whether you need to connect a legacy Modbus device to a modern EtherNet\/IP network or implement secure industrial cellular connectivity for remote telemetry, ProSoft hardware provides the \"universal translator\" capabilities required for a truly integrated factory floor. These modules are essential for MRO teams looking to modernize their data architecture without replacing existing, functional control hardware.\u003c\/p\u003e","products":[{"product_id":"prosoft-5301-mbp-dfcm-communication-gateway-module","title":"ProSoft 5301-MBP-DFCM Communication Gateway Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft Technology\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus Plus to DF1 communication gateway\u003c\/strong\u003e. It enables seamless bi-directional data exchange between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric\/Modicon Modbus Plus networks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley DF1 devices\u003c\/strong\u003e, allowing legacy and modern industrial equipment to coexist within a single control architecture.\u003c\/p\u003e\n\u003cp\u003eThis gateway supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to four configurable DF1 serial ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat can operate in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMaster or Slave mode\u003c\/strong\u003e, providing flexibility to serve as a central data concentrator or subordinate device depending on network topology. Its rugged industrial design and specialized Modbus Plus circuitry ensure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh data integrity over long cable runs\u003c\/strong\u003e, making it ideal for large-scale manufacturing environments and SCADA systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5301-MBP-DFCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eModbus Plus ↔ DF1 Protocol Conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Plus Port\u003c\/td\u003e\n\u003ctd\u003e1 × DB9 Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Plus Addressing\u003c\/td\u003e\n\u003ctd\u003eSoftware selectable: 1–64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDF1 Ports\u003c\/td\u003e\n\u003ctd\u003eUp to 4 configurable serial ports (RS-232, RS-422, RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDF1 Communication Modes\u003c\/td\u003e\n\u003ctd\u003eMaster or Slave, Half\/Full Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Power, Modbus Plus Link, Serial Port Activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation on communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eWindows-based software for mapping and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or panel mount compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe 5301-MBP-DFCM is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePhased system upgrades connecting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Modbus Plus networks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley SLC 500 or MicroLogix controllers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA systems for aggregating data from distributed serial devices into a centralized Modbus Plus backbone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial facilities requiring integration of legacy and modern control devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 5301-MBP-DFCM support multiple DF1 devices simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Yes. With up to four configurable serial ports, it can interface with multiple DF1 devices. When acting as a DF1 Master, it polls multiple slaves and maps their data into the Modbus Plus register space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is special cabling required for the Modbus Plus port?\u003c\/strong\u003e\u003cbr\u003eA: No special cabling is required beyond standard Modbus Plus cabling. Proper termination at network segment ends is essential to prevent signal reflection and ensure data integrity.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52511144935608,"sku":"5301-MBP-DFCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5301-MBP-DFCM1.jpg?v=1769670775"},{"product_id":"prosoft-mvi69-pdps-compactlogix-profibus-dp-slave-communication-module","title":"ProSoft MVI69-PDPS CompactLogix Profibus DP Slave Communication Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69-PDPS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ProSoft Technology) is a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProfibus DP Slave communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley CompactLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. It allows a CompactLogix processor to operate as a Profibus DP Slave, enabling seamless data exchange with Profibus Masters such as Siemens PLCs or DCS controllers. By integrating the MVI69-PDPS into the I\/O rack, engineers can bridge Rockwell Automation environments with standardized European fieldbus networks.\u003c\/p\u003e\n\u003cp\u003eThis module functions as a backplane-compatible plug-in, appearing as a standard I\/O module to the processor. It manages the timing and protocol complexities of Profibus DP, offloading communication overhead from the main CPU. With support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebaud rates up to 12 Mbps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand an internal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e400-word data map\u003c\/strong\u003e, it delivers reliable, high-speed performance for time-critical industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eMVI69-PDPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProfibus DP Slave Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA max @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Power, Module Status, Application, and Serial Port Activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Port\u003c\/td\u003e\n\u003ctd\u003eRJ45 (RS-232 via supplied DB-9M cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003e400 registers (16-bit words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate Support\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps, auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 244 bytes Input \/ 244 bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Occupancy\u003c\/td\u003e\n\u003ctd\u003eSingle-slot, 1769 backplane compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe MVI69-PDPS is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehybrid automation environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere a CompactLogix system must communicate with a Siemens-based Profibus Master. Typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomotive assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment and process skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly useful in cross-vendor systems where seamless\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einteroperability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI69-PDPS require a GSD file for configuration?\u003c\/strong\u003e\u003cbr\u003eA: Yes. A ProSoft-provided GSD file is needed to integrate the module into a Profibus Master’s configuration tool (e.g., TIA Portal or Step 7). The GSD file defines the module’s capabilities to the Master.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I configure the module through the CompactLogix backplane?\u003c\/strong\u003e\u003cbr\u003eA: No. While data exchange occurs via the backplane, initial protocol setup and diagnostics are performed through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated RS-232 Configuration (CFG) port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing ProSoft Configuration Builder software.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52511156338872,"sku":"MVI69-PDPS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69-PDPS1.jpg?v=1769675666"},{"product_id":"prosoft-3170-mbs-modbus-slave-communications-adapter","title":"ProSoft | 3170-MBS | Modbus Slave Communications Adapter","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e  The \u003cstrong\u003eProSoft 3170-MBS\u003c\/strong\u003e Modbus Slave Communications Adapter is designed to provide seamless connectivity between PLCs and machine control systems using the Modbus protocol. Compact and DIN rail mountable, it offers reliable communication performance in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003e3170-MBS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Modbus Slave Communications Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e: 12–24 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e: PLCs \/ Machine Control, PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.40 lbs (approx. 0.18 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e: Compact design for easy integration into control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus slave functionality for PLC integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperates on 12–24 V DC supply for flexible installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDIN rail mountable for quick and secure setup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight and compact for space-constrained environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for reliable communication in industrial automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of PLCs with Modbus-based systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMachine control requiring Modbus slave communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation networks needing protocol conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems with Modbus connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What voltage range does the 3170-MBS support?\u003c\/strong\u003e  A: It operates on 12–24 V DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is the module mounted?\u003c\/strong\u003e  A: It is DIN rail mountable for easy installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the weight of the unit?\u003c\/strong\u003e  A: Approximately 0.40 lbs (0.18 kg).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication role does it serve?\u003c\/strong\u003e  A: It functions as a Modbus slave adapter for PLCs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52911612166328,"sku":"3170-MBS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/3170-MBS__1_06629119-2397-4232-9e3d-3195ad2d87ec.jpg?v=1772698269"},{"product_id":"prosoft-plx31-eip-mbs-ethernet-ip-to-modbus-serial-gateway","title":"ProSoft PLX31-EIP-MBS EtherNet\/IP to Modbus Serial Gateway","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-MBS\u003c\/strong\u003e Gateway provides seamless communication between EtherNet\/IP networks and Modbus serial devices. Designed for industrial automation, it ensures reliable protocol conversion, robust isolation, and diagnostic visibility through LED indicators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003ePLX31-EIP-MBS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: EtherNet\/IP to Modbus Serial Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNominal: 24 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRange: 10–36 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Load: 300 mA @ 24 V DC nominal, 610 mA max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -25°C to +70°C (-13°F to +158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +80°C (-40°F to +176°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5%–95% RH, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e: IEC 60068-2-6; 5G @ 10–150 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: CFG, ERR, PWR, FLT, NS, EtherNet\/IP connection status, MS, Ethernet link\/activity, RX\/TX serial communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e10\/100 Mbit half-duplex RJ45\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical isolation: 1500 Vrms (IEC 60950 compliance)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBroadcast storm resiliency ≤ 5000 ARP frames\/s for ≤ 5 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Port\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eQuantity: 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIsolation: 2500 Vrms per UL 1577\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIsolation medium: RF modulation (SiliconLabs Si844x series IC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e: 13.67 × 5.05 × 11.13 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConverts EtherNet\/IP to Modbus serial protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh isolation for both Ethernet and serial ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLED indicators for real-time diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for DIN rail mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide operating temperature range for industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of Modbus devices into EtherNet\/IP networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSubstation automation and machine control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial communication requiring protocol conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems with mixed protocol environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What power supply range does the PLX31-EIP-MBS support?\u003c\/strong\u003e  A: It operates from 10 to 36 V DC, nominal 24 V DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many serial ports are available?\u003c\/strong\u003e  A: The unit provides one isolated serial port.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What isolation rating is provided for communication ports?\u003c\/strong\u003e  A: Ethernet isolation is 1500 Vrms, serial isolation is 2500 Vrms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e  A: -25°C to +70°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52911664791736,"sku":"PLX31-EIP-MBS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBS_7934abf6-cc03-4e44-a4da-0ad463ffed6a.jpg?v=1772698330"},{"product_id":"plx31-eip-mbs4-prosoft-ethernet-ip-to-modbus-four-port-gateway","title":"PLX31-EIP-MBS4 | ProSoft | EtherNet\/IP to Modbus Four-Port Gateway","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-MBS4\u003c\/strong\u003e Gateway is designed to connect EtherNet\/IP networks with Modbus serial devices. Featuring four isolated serial ports, it supports multiple simultaneous connections and ensures reliable communication in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: \u003cstrong\u003ePLX31-EIP-MBS4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: EtherNet\/IP to Modbus Serial Four-Port Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClass 3 Server Connections: 5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClass 1 I\/O Connections: 8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eI\/O Connection Sizes: 248\/248\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMax RPI Time: 5 ms per connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNominal: 24 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRange: 10–36 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Load: 300 mA @ 24 V DC nominal, 610 mA maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: 4 isolated ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -25°C to +70°C (-13°F to +158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +80°C (-40°F to +176°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5%–95% RH, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e: IEC 60068-2-6; 5G @ 10–150 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e: 13.67 × 5.05 × 11.13 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 3 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour-port Modbus serial gateway for expanded connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports multiple EtherNet\/IP Class 1 and Class 3 connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFast RPI times for real-time communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide operating temperature range for industrial use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design suitable for control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of Modbus devices into EtherNet\/IP networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSubstation automation and machine control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial communication requiring multi-port protocol conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems with high connection density\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many serial ports does the PLX31-EIP-MBS4 provide?\u003c\/strong\u003e  A: It includes four isolated serial ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum RPI time supported?\u003c\/strong\u003e  A: 5 ms per connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e  A: -25°C to +70°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the shipping weight of the unit?\u003c\/strong\u003e  A: Approximately 3 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52911684485304,"sku":"PLX31-EIP-MBS4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBS_55176e0e-0b40-4004-9ef2-36eb3be17ca6.jpg?v=1772698355"},{"product_id":"5204-dfnt-pdpm-prosoft-ethernet-ip-to-profibus-dp-gateway-module-24-vdc","title":"5204-DFNT-PDPM | ProSoft | EtherNet\/IP to Profibus DP Gateway Module 24 VDC","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e5204-DFNT-PDPMV1 5204-DFNT-PDPM\u003c\/strong\u003e Gateway Module from ProSoft is designed to bridge EtherNet\/IP networks with Profibus DP systems. This communication interface enables seamless integration between PLCs and distributed automation devices. Operating on 24 VDC, the unit supports a voltage range of 18–32 VDC and includes ground terminals for secure installation. Though discontinued by the manufacturer, it remains a critical spare part for legacy systems requiring EtherNet\/IP to Profibus DP connectivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e5204-DFNT-PDPM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e5204-DFNT-PDPMV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to Profibus DP Gateway Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs \/ Machine Control, PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 VDC (18–32 VDC range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnection Terminals:\u003c\/strong\u003e Ground terminals, 2.5 mm screwdriver blade type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.90 lbs (approx. 0.41 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus:\u003c\/strong\u003e Discontinued by manufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides communication between EtherNet\/IP and Profibus DP networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for rack-mounted PLC integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports industrial-grade voltage range for reliable operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for legacy automation systems requiring protocol conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of EtherNet\/IP-based PLCs with Profibus DP field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring cross-network communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSpare part replacement for discontinued ProSoft gateway modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating voltage range of the 5204-DFNT-PDPM?\u003c\/strong\u003e  A: It operates at 24 VDC with an allowable range of 18–32 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this product still manufactured?\u003c\/strong\u003e  A: No, the \u003cstrong\u003e5204-DFNT-PDPMV1\u003c\/strong\u003e has been discontinued by ProSoft.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of networks does this gateway connect?\u003c\/strong\u003e  A: It connects EtherNet\/IP networks to Profibus DP systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980066451640,"sku":"5204-DFNT-PDPM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5204-DFNT-PDPM.jpg?v=1773044941"},{"product_id":"prosoft-mvi56-hart-multi-drop-master-communication-interface-module","title":"ProSoft | MVI56-HART | Multi-Drop Master Communication Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56-HART\u003c\/strong\u003e Communication Module is a specialized interface designed by ProSoft to enable HART protocol integration within PLC systems. This module functions as a multi-drop master, supporting up to four communication channels. With a compact design and reliable performance, it provides seamless connectivity for process automation environments. Although discontinued by the manufacturer as of January 1, 2020, the MVI56-HART remains an important spare part for legacy systems requiring HART protocol support.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56-HART\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Multi-Drop Master Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs \/ Machine Control, PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 4 communication channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 800 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 5.1 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.68 lbs (approx. 0.31 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides HART protocol master communication for PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports multi-drop configuration with four channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for rack-mounted PLC integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStable operation with 800 mA current draw at 5.1 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of HART-enabled field devices with PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy automation systems requiring HART protocol communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSpare part replacement for discontinued ProSoft modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels does the MVI56-HART support?\u003c\/strong\u003e  A: It supports four communication channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating voltage of the MVI56-HART?\u003c\/strong\u003e  A: The module operates at 5.1 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this product still manufactured?\u003c\/strong\u003e  A: No, the \u003cstrong\u003eMVI56-HART\u003c\/strong\u003e was discontinued on January 1, 2020.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980099547320,"sku":"MVI56-HART","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-HART.jpg?v=1773045214"},{"product_id":"mvi56e-mnetc-prosoft-modbus-tcp-ip-enhanced-client-server-communication-module","title":"MVI56E-MNETC | ProSoft | Modbus TCP\/IP Enhanced Client\/Server Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e Enhanced Communication Module from ProSoft is designed to provide seamless Modbus TCP\/IP connectivity for PLC systems. Operating as both client and server, this module ensures reliable communication between controllers and distributed devices. With robust environmental tolerance and conformal coating available in the \u003cstrong\u003eMVI56E-MNETCXT\u003c\/strong\u003e variant, it is suitable for standard and harsh industrial conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module (Client\/Server)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e3 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard: 0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExtended (MVI56E-MNETCXT): -25°C to 70°C (-13°F to 158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExtreme Environment Protection:\u003c\/strong\u003e Conformal coating (MVI56E-MNETCXT)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Application Status (APP), Module Status (OK), ERR (not used)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports Modbus TCP\/IP client and server communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnhanced environmental tolerance with conformal coating option\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for rack-mounted PLC integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClear LED indicators for module and application status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of Modbus TCP\/IP devices into PLC-based automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial environments requiring reliable client\/server communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh operating conditions supported by conformal-coated variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the difference between MVI56E-MNETC and MVI56E-MNETCXT?\u003c\/strong\u003e  A: The XT version includes conformal coating for extreme or harsh environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What voltage does the module require?\u003c\/strong\u003e  A: It consumes 800 mA at 5 VDC and 3 mA at 24 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication role does the module support?\u003c\/strong\u003e  A: It functions as both Modbus TCP\/IP client and server.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980100268216,"sku":"MVI56E-MNETC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETC.jpg?v=1773045388"},{"product_id":"mvi69-mcm-prosoft-modbus-master-slave-network-interface-module","title":"MVI69-MCM | ProSoft Modbus Master\/Slave Network Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e Modbus Master\/Slave Network Interface Module is a versatile communication solution developed by ProSoft Technology for Rockwell Automation’s CompactLogix and MicroLogix controllers. This module enables seamless integration with Modbus-compatible devices, including Modicon PLCs and third-party equipment. Supporting both master and slave configurations, the MVI69-MCM allows controllers to manage multiple devices on the same network, ensuring reliable data exchange and flexible system integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Rockwell Automation \/ Allen-Bradley brand)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Master\/Slave Network Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e CompactLogix and MicroLogix controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot Type:\u003c\/strong\u003e Single-slot (1769 standard module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Support:\u003c\/strong\u003e Ladder Logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Range:\u003c\/strong\u003e 110 to 115K baud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNode Address Range:\u003c\/strong\u003e 1–247\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e Max 800 mA at 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Standard 1769 single-slot module size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.68 lbs (approx. 0.31 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports both Modbus master and slave configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnables communication with Modicon PLCs and third-party Modbus devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReliable performance with wide baud rate support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible addressing for up to 247 nodes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of CompactLogix\/MicroLogix controllers with Modbus field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring Modbus protocol communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades where Modbus compatibility is essential\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the MVI69-MCM act as both a master and a slave?\u003c\/strong\u003e  A: Yes, it supports both configurations for flexible communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What controllers are compatible with the MVI69-MCM?\u003c\/strong\u003e  A: It works with Rockwell Automation’s CompactLogix and MicroLogix controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum baud rate supported?\u003c\/strong\u003e  A: The module supports baud rates up to 115K.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980100661432,"sku":"MVI69-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69-MCM2.jpg?v=1773045657"},{"product_id":"mvi69e-mbtcp-prosoft-modbus-tcp-ip-enhanced-communication-module","title":"MVI69E-MBTCP | ProSoft | Modbus TCP\/IP Enhanced Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module is engineered by ProSoft Technology to provide advanced networking capabilities for Rockwell Automation CompactLogix controllers. Designed for seamless integration, this module supports both client and server roles, enabling efficient communication with Modbus-compatible devices and SCADA systems. With diagnostic data available directly in controller tags, system health monitoring and decision-making are simplified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e CompactLogix processors with 1769 I\/O bus capability (v16 and above; not compatible with MicroLogix 1500)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnections Supported:\u003c\/strong\u003e Up to 20 client and 20 server connections simultaneously\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Capacity:\u003c\/strong\u003e Supports up to 10,000 words of data\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFloating Point Support:\u003c\/strong\u003e Enron and Daniel style implementations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Integration:\u003c\/strong\u003e Add-on Instruction creates UDTs for logical I\/O, status, and control definitions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdd-on Profile:\u003c\/strong\u003e Simplifies integration into CompactLogix systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Node health data available in controller tags\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Backed up within CompactLogix project (ACD file)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e Operates as a co-processor, reducing PLC scan time impact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (standard), -25°C to 70°C for \u003cstrong\u003eMVI69E-MBTCPXT\u003c\/strong\u003e variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExtreme Environment Protection:\u003c\/strong\u003e Conformal coating available in XT version\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Application Status (APP), Module Status (OK), ERR (unused)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnhanced Modbus TCP\/IP client\/server communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports SCADA and field device interface applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConformal-coated XT version for harsh environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimplified integration with CompactLogix controllers via add-on profiles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge data handling capacity with reduced PLC scan time impact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring Modbus TCP\/IP communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA integration with CompactLogix controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh environment installations supported by XT variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing enhanced Modbus TCP\/IP support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What controllers are supported by the MVI69E-MBTCP?\u003c\/strong\u003e  A: CompactLogix processors with 1769 I\/O bus capability version 16 and above.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many connections can the module handle?\u003c\/strong\u003e  A: Up to 20 client and 20 server connections simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the difference between MVI69E-MBTCP and MVI69E-MBTCPXT?\u003c\/strong\u003e  A: The XT version includes conformal coating for extreme or harsh environments.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980101349560,"sku":"MVI69E-MBTCP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69E-MBTCP.jpg?v=1773045970"},{"product_id":"mvi56e-mnet-prosoft-controllogix-modbus-tcp-ip-enhanced-client-server-module","title":"MVI56E-MNET | ProSoft ControlLogix Modbus TCP\/IP Enhanced Client\/Server Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module is designed by ProSoft Technology to provide reliable client\/server networking capabilities for Rockwell Automation’s ControlLogix systems. This single-slot module integrates seamlessly into ControlLogix chassis, enabling communication with Modbus-compatible devices and SCADA systems. With support for 5,000 registers, diagnostic monitoring, and conformal coating for protection, the MVI56E-MNET ensures robust performance in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley ControlLogix line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Client\/Server Enhanced Network Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e ControlLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56E-MNET\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC, 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Width:\u003c\/strong\u003e Single slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Rack:\u003c\/strong\u003e ControlLogix chassis (local or remote)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Size:\u003c\/strong\u003e 5,000 words, 16-bit registers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Add-On Instruction (AOI), Sample Ladder Logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Processor:\u003c\/strong\u003e ControlLogix processor version 10 or higher\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Port:\u003c\/strong\u003e One RJ45 Ethernet interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Rate:\u003c\/strong\u003e 10\/100 Mbps (Ethernet 10\/100 Base-T)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e ERR (Battery Status), APP (Application Status), OK (Module Status)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock:\u003c\/strong\u003e 30 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e Conformal-coated for durability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus TCP\/IP client\/server communication for ControlLogix systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports 5,000 registers with user-definable memory mapping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic data available in controller tags for system monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConformal coating for enhanced protection in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of ControlLogix controllers with Modbus TCP\/IP devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA system communication requiring Modbus protocol support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems needing reliable Ethernet-based connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh environment installations supported by conformal-coated design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What processors are compatible with the MVI56E-MNET?\u003c\/strong\u003e  A: ControlLogix processors version 10 or higher.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many registers does the module support?\u003c\/strong\u003e  A: Up to 5,000 16-bit registers with user-definable mapping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e  A: 0°C to 60°C for operation, -40°C to 85°C for storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI56-MNET\u003c\/strong\u003e – Standard Modbus TCP\/IP module with fewer advanced features.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e – Enhanced version with extended client\/server capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980106526904,"sku":"MVI56E-MNET","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETC_da172878-5f03-4daa-91ff-4a628f703e25.jpg?v=1773046157"},{"product_id":"prosoft-mvi46-mcm-slc-500-modbus-master-slave-communication-module","title":"ProSoft | MVI46-MCM | SLC 500 Modbus Master\/Slave Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI46-MCM\u003c\/strong\u003e Modbus Communication Module is a single-slot interface designed by ProSoft Technology for Rockwell Automation’s SLC 500 platform. This module enables seamless communication between SLC controllers and Modbus-compatible devices, supporting both master and slave configurations. With dual application ports and robust diagnostic indicators, the MVI46-MCM provides reliable data exchange in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI46-MCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley SLC 500 line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Master\/Slave Network Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SLC 500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI46-MCM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5.1 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Width:\u003c\/strong\u003e Single slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Rack:\u003c\/strong\u003e 1746 chassis (local and extended rack only)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Processors:\u003c\/strong\u003e SLC 5\/02 M0\/M1 capable processors or later models\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Port:\u003c\/strong\u003e RJ45 (DB-9M with supplied cable), RS-232 only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication Ports:\u003c\/strong\u003e Two RJ45 RS-232\/422\/485 ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Module status, backplane transfer status, application status, serial activity, error status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock:\u003c\/strong\u003e 30 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRegisters Supported:\u003c\/strong\u003e Up to 5,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommands per Port:\u003c\/strong\u003e Up to 100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports Modbus master and slave communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual application ports for flexible connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic LEDs for monitoring module and communication status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLadder Logic programming support for data transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy integration into SLC 500 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of SLC 500 controllers with Modbus-compatible field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring Modbus protocol communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing reliable Modbus master\/slave support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What controllers are compatible with the MVI46-MCM?\u003c\/strong\u003e  A: It works with SLC 5\/02 M0\/M1 capable processors and later models.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many registers does the module support?\u003c\/strong\u003e  A: Up to 5,000 registers can be defined.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication ports are available?\u003c\/strong\u003e  A: One RS-232 configuration port and two RS-232\/422\/485 application ports.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980117110968,"sku":"MVI46-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI46-MCM.jpg?v=1773046349"},{"product_id":"prosoft-mvi56-gsc-controllogix-generic-serial-ascii-interface-module","title":"ProSoft MVI56-GSC | ControlLogix Generic Serial ASCII Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56-GSC\u003c\/strong\u003e module from ProSoft Technology adds two configurable serial communication ports to Rockwell Automation ControlLogix processors. It is designed to handle ASCII-based protocols such as Modbus ASCII and Allen-Bradley DF1, enabling communication with a wide range of external devices. By offloading serial communication tasks from the processor, the module ensures efficient data handling without consuming CPU resources.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach port supports large ASCII string transfers, making the module suitable for barcode scanners, printers, weigh scales, and legacy PLCs. Its single-slot backplane-compatible design simplifies installation and integration into existing ControlLogix systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56-GSC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePlatform Compatibility:\u003c\/strong\u003e Rockwell ControlLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Generic Serial ASCII Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePorts:\u003c\/strong\u003e Two independent configurable serial ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e ASCII, Modbus ASCII, DF1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Options:\u003c\/strong\u003e Baud rate, data bits, stop bits, parity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e Single-slot backplane compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdds two fully configurable serial ports to ControlLogix processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports ASCII-based communication for broad device compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHandles large ASCII strings for complex messaging applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimplifies integration with legacy devices and SCADA systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackplane-compatible design for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnecting barcode readers, printers, and weigh scales\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrating legacy PLCs using Modbus ASCII or DF1 protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring serial communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What protocols does the MVI56-GSC support?\u003c\/strong\u003e  A: ASCII, Modbus ASCII, and Allen-Bradley DF1.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many serial ports are available?\u003c\/strong\u003e  A: Two independent configurable ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What types of devices can be connected?\u003c\/strong\u003e  A: Barcode scanners, printers, weigh scales, and legacy PLCs.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980117504184,"sku":"MVI56-GSC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI46-MCM_4827af85-201f-4c74-af5f-ead9d7774007.jpg?v=1773046552"},{"product_id":"mvi56-gec-prosoft-controllogix-generic-ascii-ethernet-communication-module","title":"MVI56-GEC | ProSoft ControlLogix Generic ASCII Ethernet Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56-GEC\u003c\/strong\u003e module from ProSoft Technology provides ASCII-based Ethernet communication capabilities for Rockwell Automation’s ControlLogix systems. Designed as a single-slot interface, it enables controllers to exchange ASCII data over Ethernet networks without consuming processor resources. With optical isolation and robust design, the MVI56-GEC ensures reliable communication in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56-GEC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley ControlLogix line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Generic ASCII Ethernet Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e ControlLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56-GEC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e 1 (single-slot module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRack Type:\u003c\/strong\u003e Local or remote ControlLogix chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Type:\u003c\/strong\u003e Ladder Logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e 10\/100 MB Ethernet-compatible port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Range:\u003c\/strong\u003e 110 to 115,200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e 500V from backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides ASCII Ethernet communication for ControlLogix processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports baud rates from 110 to 115,200 for flexible device integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptical isolation ensures protection from backplane interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic indicators for monitoring communication status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of ControlLogix controllers with ASCII-based Ethernet devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring ASCII protocol communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed communication requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy device connectivity via ASCII Ethernet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of communication does the MVI56-GEC support?\u003c\/strong\u003e  A: ASCII-based Ethernet communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the baud rate range?\u003c\/strong\u003e  A: 110 to 115,200 baud.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is the module protected from interference?\u003c\/strong\u003e  A: It features 500V optical isolation from the backplane.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980118290616,"sku":"MVI56-GEC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-GEC.jpg?v=1773046759"},{"product_id":"prosoft-5201-dfnt-mcm-ethernet-ip-to-modbus-master-slave-gateway-module","title":"ProSoft | 5201-DFNT-MCM | EtherNet\/IP to Modbus Master\/Slave Gateway Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e5201-DFNT-MCM\u003c\/strong\u003e Gateway Module from ProSoft Technology is designed to bridge EtherNet\/IP networks with Modbus Master\/Slave devices. This interface enables seamless communication between Rockwell Automation controllers and Modbus-compatible equipment, ensuring interoperability across diverse industrial systems. Compact and DIN rail mountable, the module is engineered for reliable operation in demanding environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e5201-DFNT-MCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to Modbus Master\/Slave Gateway Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs \/ Machine Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSubcategory:\u003c\/strong\u003e PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.97 lbs (approx. 0.44 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported:\u003c\/strong\u003e EtherNet\/IP and Modbus Master\/Slave (MCM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10Base-T half-duplex RJ45 with link\/activity LEDs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 2 × DB9 female connectors (RS-232\/RS-422\/RS-485)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Rate:\u003c\/strong\u003e 110–115 kbps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1500 Vrms (Ethernet port)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2500 Vrms (Modbus port)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMinimum isolation between port-to-ground and port-to-logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 18–32 VDC via screw terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e DIN rail mountable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides communication between EtherNet\/IP and Modbus networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports both Modbus master and slave configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for DIN rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh isolation levels for reliable operation in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLED indicators for link and activity monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980119077048,"sku":"5201-DFNT-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5201-DFNT-MCM.jpg?v=1773047027"},{"product_id":"prosoft-mvi56-pdps-controllogix-profibus-dp-slave-communication-module","title":"ProSoft | MVI56-PDPS | ControlLogix PROFIBUS DP Slave Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56-PDPS\u003c\/strong\u003e PROFIBUS DP Slave Communication Module is engineered by ProSoft Technology to provide seamless integration of Rockwell Automation ControlLogix systems with PROFIBUS networks. Designed as a single-slot module, it supports high-speed communication and reliable data exchange, enabling controllers to act as PROFIBUS slave devices. With robust electrical isolation and diagnostic capabilities, the MVI56-PDPS ensures dependable operation in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56-PDPS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley ControlLogix line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP Slave Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e 1 (single-slot module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRack Type:\u003c\/strong\u003e Local or remote ControlLogix chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer:\u003c\/strong\u003e Ladder Logic programming support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e Up to 12 Mbps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePROFIBUS Node Address Range:\u003c\/strong\u003e 0–125\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Data Capacity:\u003c\/strong\u003e 122 words maximum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Rate:\u003c\/strong\u003e 110–115,200 baud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 5–24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnables ControlLogix processors to function as PROFIBUS DP slave devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-speed communication up to 12 Mbps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide node address range for flexible network integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical isolation for enhanced reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of ControlLogix controllers into PROFIBUS DP networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring slave device communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing PROFIBUS compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980119896248,"sku":"MVI56-PDPS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETC_e77d7df0-4a28-4ac2-8120-6fe372adac92.jpg?v=1773047192"},{"product_id":"mvi56-pdpmv1-prosoft-controllogix-profibus-dpv1-master-communication-module","title":"MVI56-PDPMV1 | ProSoft ControlLogix PROFIBUS DPV1 Master Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56-PDPMV1\u003c\/strong\u003e PROFIBUS DPV1 Master Communication Module is designed by ProSoft Technology to integrate Rockwell Automation ControlLogix systems with PROFIBUS DP networks. Acting as a master device, it enables controllers to manage and communicate with multiple PROFIBUS slave devices. With robust diagnostic indicators, high-speed communication, and CIPConnect® Ethernet routing support, the MVI56-PDPMV1 ensures reliable performance in complex automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56-PDPMV1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DPV1 Master Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC, 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational, 50 g non-operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5 g from 10 Hz to 150 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Module Status, Backplane Transfer Status, Application Status, Serial Activity, Error Status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Port:\u003c\/strong\u003e RJ45 (DB-9M with supplied cable), RS-232 only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Routing:\u003c\/strong\u003e CIPConnect® via 1756-ENBT, 1756-EN2T, or similar modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e RJ45 to DB-9M cables for each port, 6-foot RS-232 configuration cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides PROFIBUS DPV1 master communication for ControlLogix processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports CIPConnect® Ethernet routing for simplified configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic LEDs for monitoring module and communication status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes configuration cables for quick installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for reliable operation in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControlLogix systems requiring PROFIBUS DPV1 master functionality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation networks with multiple PROFIBUS slave devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol communication requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing PROFIBUS DP integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What role does the MVI56-PDPMV1 perform in a PROFIBUS network?\u003c\/strong\u003e  A: It acts as a PROFIBUS DPV1 master, managing communication with slave devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What accessories are included with the module?\u003c\/strong\u003e  A: RJ45 to DB-9M cables for each port and a 6-foot RS-232 configuration cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is Ethernet routing supported?\u003c\/strong\u003e  A: Through CIPConnect® using modules such as 1756-ENBT or 1756-EN2T.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI56-PDPS\u003c\/strong\u003e – PROFIBUS DP Slave communication module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e – Enhanced Modbus TCP\/IP communication module for ControlLogix.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980123074744,"sku":"MVI56-PDPMV1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-PDPMV1.jpg?v=1773047361"},{"product_id":"prosoft-mvi71-mcm-plc-5-modbus-master-slave-communication-module","title":"ProSoft MVI71-MCM PLC-5 Modbus Master\/Slave Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI71-MCM\u003c\/strong\u003e Modbus Master\/Slave Communication Module is designed by ProSoft Technology to provide Rockwell Automation PLC-5 controllers with Modbus protocol support. This single-slot module enables seamless communication with Modbus-compatible devices, supporting both master and slave configurations. With robust data handling and Ladder Logic integration, the MVI71-MCM ensures reliable interoperability across diverse automation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI71-MCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley PLC-5 line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Master\/Slave Network Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e PLC-5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI71-MCM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e 1 (single-slot module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRack Type:\u003c\/strong\u003e Local or remote PLC-5 chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer:\u003c\/strong\u003e Ladder Logic programming support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRegisters Supported:\u003c\/strong\u003e Up to 5,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus master and slave communication for PLC-5 controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports up to 5,000 registers for flexible data mapping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLadder Logic support for seamless programming\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReliable operation with 30 g shock resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of PLC-5 controllers with Modbus-compatible field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring Modbus protocol communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing Modbus connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What controllers are compatible with the MVI71-MCM?\u003c\/strong\u003e  A: It is designed for Rockwell Automation PLC-5 controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many registers does the module support?\u003c\/strong\u003e  A: Up to 5,000 registers can be defined.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the backplane current load requirement?\u003c\/strong\u003e  A: 800 mA at 5 VDC.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980125073592,"sku":"MVI71-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI71-MCM.jpg?v=1773047560"},{"product_id":"prosoft-mvi69e-mbs-compactlogix-modbus-serial-enhanced-communication-module","title":"ProSoft | MVI69E-MBS | CompactLogix Modbus Serial Enhanced Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI69E-MBS\u003c\/strong\u003e Modbus Serial Enhanced Communication Module is designed by ProSoft Technology to extend Rockwell Automation CompactLogix controllers with advanced Modbus serial communication capabilities. Supporting both master and slave configurations, this module allows seamless integration with Modbus-compatible devices across industrial networks. With flexible configuration options and high data throughput, the MVI69E-MBS ensures reliable communication in demanding automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI69E-MBS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley CompactLogix line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Serial Enhanced Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e CompactLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI69E-MBS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Tool:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Size Options:\u003c\/strong\u003e 60, 120, or 240 (16-bit integers)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Range:\u003c\/strong\u003e 110 to 115,200 baud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStop Bits:\u003c\/strong\u003e Configurable (1 or 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommands per Master Port:\u003c\/strong\u003e Up to 250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 500 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus serial communication for CompactLogix controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports both master and slave roles for flexible integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh command capacity per master port (250 commands)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple I\/O size options for scalable applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of CompactLogix controllers with Modbus-compatible field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring serial communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing Modbus serial connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What controllers are compatible with the MVI69E-MBS?\u003c\/strong\u003e  A: It is designed for Rockwell Automation CompactLogix controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many commands can each master port handle?\u003c\/strong\u003e  A: Up to 250 commands per master port.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What configuration tool is used?\u003c\/strong\u003e  A: ProSoft Configuration Builder (PCB).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e – Standard Modbus Master\/Slave module for CompactLogix.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI56-MCM\u003c\/strong\u003e – Modbus communication module for ControlLogix systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980129792184,"sku":"MVI69E-MBS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69E-MBS.jpg?v=1773047724"},{"product_id":"mvi56-adm-prosoft-controllogix-c-programmable-application-development-module","title":"MVI56-ADM | ProSoft ControlLogix ‘C’ Programmable Application Development Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56-ADM\u003c\/strong\u003e Application Development Module is a specialized single-slot interface designed for Rockwell Automation ControlLogix systems. Built to support custom applications written in the ‘C’ programming language, this module provides engineers with the flexibility to develop and deploy tailored solutions directly within the ControlLogix platform. With optical isolation, robust shock resistance, and Ladder Logic integration, the MVI56-ADM ensures reliable performance in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56-ADM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley ControlLogix line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e ‘C’ Programmable Application Development Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e ControlLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56-ADM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.00 lbs (5.44 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e 1 (single-slot module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRack Type:\u003c\/strong\u003e Local or remote ControlLogix chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Type:\u003c\/strong\u003e Ladder Logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Range:\u003c\/strong\u003e 110 to 115,200 baud\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e 500V from backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Port:\u003c\/strong\u003e RJ45\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides a programmable environment for custom ‘C’ applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeamless integration with ControlLogix processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptical isolation for enhanced reliability and protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLadder Logic support for data transfer and integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRobust design with 30 g operational shock resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDevelopment of custom communication drivers for ControlLogix systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of proprietary protocols into industrial automation networks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms requiring specialized data handling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing custom application support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What programming language does the MVI56-ADM support?\u003c\/strong\u003e  A: It supports applications written in the ‘C’ programming language.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is the module configured?\u003c\/strong\u003e  A: Configuration is performed via the RJ45 port.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the backplane current load requirement?\u003c\/strong\u003e  A: 800 mA at 5 VDC.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980130414776,"sku":"MVI56-ADM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETC_e0f33f98-deee-4fe3-a7f0-30c6574b00fe.jpg?v=1773047991"},{"product_id":"prosoft-mvi69-mnet-compactlogix-modbus-tcp-ip-communication-module","title":"ProSoft | MVI69-MNET | CompactLogix Modbus TCP\/IP Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI69-MNET\u003c\/strong\u003e Modbus TCP\/IP Communication Module is designed by ProSoft Technology to provide CompactLogix controllers with reliable Modbus TCP\/IP networking capabilities. This single-slot module enables seamless communication with Modbus-compatible devices, supporting up to 5,000 registers and 100 client commands. With Ladder Logic integration and robust electrical performance, the MVI69-MNET ensures dependable operation in industrial automation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI69-MNET\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley CompactLogix line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e CompactLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI69-MNET\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e 1 (single-slot module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Type:\u003c\/strong\u003e Ladder Logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRegisters Supported:\u003c\/strong\u003e Up to 5,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eClient Commands Supported:\u003c\/strong\u003e Up to 100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e Maximum 800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus TCP\/IP communication for CompactLogix controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports up to 5,000 registers for flexible data mapping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHandles up to 100 client commands for efficient communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact single-slot design for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLadder Logic support for seamless integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of CompactLogix controllers with Modbus TCP\/IP devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring Ethernet-based Modbus communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing Modbus TCP\/IP support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What controllers are compatible with the MVI69-MNET?\u003c\/strong\u003e  A: It is designed for Rockwell Automation CompactLogix controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many registers does the module support?\u003c\/strong\u003e  A: Up to 5,000 registers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum number of client commands supported?\u003c\/strong\u003e  A: Up to 100 client commands.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e – Enhanced Modbus TCP\/IP module with expanded features.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e – Modbus TCP\/IP communication module for ControlLogix systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980134510776,"sku":"MVI69-MNET","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69-MNET.jpg?v=1773048161"},{"product_id":"prosoft-mvi56e-mcmr-controllogix-enhanced-modbus-master-slave-communication-module","title":"ProSoft | MVI56E-MCMR ControlLogix Enhanced Modbus Master\/Slave Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI56E-MCMR\u003c\/strong\u003e Enhanced Modbus Master\/Slave Communication Module is designed by ProSoft Technology to provide ControlLogix processors with advanced Modbus protocol support. Backward-compatible with the earlier \u003cstrong\u003eMVI56-MCM\u003c\/strong\u003e, this single-slot module integrates seamlessly into 1756 ControlLogix backplanes. It features Ethernet connectivity for configuration and diagnostics, user-definable memory mapping, and a scrolling alphanumeric LED display for real-time status and error information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith support for RIUP (Remove and Insert Under Power), robust shock and vibration resistance, and extended operating temperature ranges in the XT version, the MVI56E-MCMR is engineered for reliable performance in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI56E-MCMR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Master\/Slave Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e ControlLogix 1756 backplane (single-slot)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 10\/100 MB with auto cable crossover detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Memory Mapping:\u003c\/strong\u003e Up to 10,000 16-bit registers, user-definable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Display:\u003c\/strong\u003e 4-character scrolling alphanumeric LED (status, IP, port, errors)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Support:\u003c\/strong\u003e ProSoft Discovery Service (PDS) for IP assignment and module detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRIUP Support:\u003c\/strong\u003e Remove and Insert Under Power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC, 3 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard: 0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eXT Version: -25°C to 70°C (-13°F to 158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational, 50 g non-operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5 g from 10 Hz to 150 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e ERR (Battery), APP (Application), OK (Module Status)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBackward-compatible with MVI56-MCM legacy modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet-based configuration and diagnostics with auto crossover detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge memory mapping capacity (10,000 registers)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time diagnostic display in plain English\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRIUP functionality for simplified maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eXT variant available for extended temperature ranges\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of ControlLogix controllers with Modbus-compatible devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems requiring master\/slave Modbus communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHarsh environment installations supported by XT version\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980140048568,"sku":"MVI56E-MCMR","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETC_d3f03193-b820-4afa-89b9-f518694db357.jpg?v=1773048301"},{"product_id":"prosoft-technology-plx32-eip-mbtcp-ethernet-ip-to-modbus-tcp-ip-gateway","title":"ProSoft Technology | PLX32-EIP-MBTCP | EtherNet\/IP to Modbus TCP\/IP Gateway","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e Gateway Module from ProSoft Technology is engineered to connect EtherNet\/IP and Modbus TCP\/IP networks seamlessly. With dual Ethernet ports, the gateway allows EtherNet\/IP and Modbus TCP\/IP traffic to operate on separate subnets while maintaining simultaneous access to shared process data. It also supports OPC UA, enabling three protocols to run independently without interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis gateway prioritizes data flow with multiple EtherNet\/IP I\/O connections, allowing different Requested Packet Intervals (RPIs) for status and control data. Integration is simplified through an embedded EDS Add-On Profile, reducing commissioning time. For disaster recovery, the PLX32-EIP-MBTCP includes an SD card slot for configuration file storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003ePLX32-EIP-MBTCP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to Modbus TCP\/IP Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e Two independent ports (supports subnet separation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported:\u003c\/strong\u003e EtherNet\/IP, Modbus TCP\/IP, OPC UA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Prioritization:\u003c\/strong\u003e Multiple EtherNet\/IP I\/O connections with configurable RPIs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntegration Support:\u003c\/strong\u003e Embedded EDS Add-On Profile\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Storage:\u003c\/strong\u003e SD card slot (SD card optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 2.0 lbs (0.9 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual Ethernet ports for subnet separation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimultaneous operation of EtherNet\/IP, Modbus TCP\/IP, and OPC UA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData prioritization for optimized control and monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimplified commissioning with embedded Add-On Profile\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSD card slot for disaster recovery and configuration backup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of EtherNet\/IP controllers with Modbus TCP\/IP devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms requiring multi-protocol communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation systems with mixed protocol requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisaster recovery planning with configuration file backup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980144079032,"sku":"PLX32-EIP-MBTCP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX32-EIP-MBTCP.jpg?v=1773048477"},{"product_id":"prosoft-technology-mvi46-mnet-slc-500-modbus-tcp-ip-interface-module","title":"ProSoft Technology | MVI46-MNET | SLC 500 Modbus TCP\/IP Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI46-MNET\u003c\/strong\u003e Modbus TCP\/IP Interface Module provides Rockwell Automation’s SLC 500 processors with direct connectivity to Modbus TCP\/IP networks. Designed as a single-slot solution, the module acts as an input\/output interface between the SLC backplane and Modbus TCP\/IP devices, ensuring reliable data exchange. It supports asynchronous data transfer, allowing processor operations to continue independently of network activity. With a 5,000-word register space and configurable parameters, the MVI46-MNET is a robust solution for industrial Ethernet communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI46-MNET\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology (Allen-Bradley SLC 500 line)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Interface Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SLC 500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e 1 (single-slot module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRack Compatibility:\u003c\/strong\u003e Local or remote SLC 500 chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRegisters Supported:\u003c\/strong\u003e Up to 5,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Type:\u003c\/strong\u003e Ladder Logic with M0\/M1 file transfer support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Interface:\u003c\/strong\u003e 10\/100 Base-T, TCP\/IP compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eClient\/Server Support:\u003c\/strong\u003e Configurable parameters for both roles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFloating Point Support:\u003c\/strong\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 800 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g operational\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 3 lbs (1.36 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus TCP\/IP communication for SLC 500 processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports asynchronous data transfer for efficient operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser-definable memory mapping for flexible applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e5,000-register capacity for large-scale data exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with Modicon Quantum processors, operator interface software, and Modbus-enabled devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980148568248,"sku":"MVI46-MNET","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI46-MNET.jpg?v=1773048647"},{"product_id":"mvi94-mcm-prosoft-flex-i-o-modbus-master-slave-communication-module","title":"MVI94-MCM | ProSoft | FLEX I\/O Modbus Master\/Slave Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI94-MCM\u003c\/strong\u003e Modbus Master\/Slave Communication Module is designed by ProSoft Technology to provide Rockwell Automation FLEX I\/O systems with Modbus protocol support. This single-slot module integrates seamlessly into the 1794 backplane, enabling communication with Modbus-compatible devices in both master and slave configurations. With dual serial ports, optical isolation, and flexible configuration options, the MVI94-MCM ensures reliable data exchange across industrial networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI94-MCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Master\/Slave Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Single-slot, 1794 backplane compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Can be installed in any slot of the FLEX I\/O backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e 20 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e 12–24 VDC, 340–170 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 55°C (32°F to 131°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Module status, backplane transfer status, application status, serial activity, error status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Port (PRT1):\u003c\/strong\u003e Mini-DIN, RS-232 with hardware handshaking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication Port (PRT2):\u003c\/strong\u003e Mini-DIN, RS-232\/422\/485 jumper selectable, 500V optical isolation from backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (with base):\u003c\/strong\u003e 9.4 cm × 9.4 cm × 6.9 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides Modbus master and slave communication for FLEX I\/O systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual serial ports with optical isolation for secure communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for easy installation in 1794 backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLED indicators for real-time diagnostics and monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports RS-232, RS-422, and RS-485 communication standards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of FLEX I\/O systems with Modbus-compatible field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation requiring Modbus protocol support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSCADA platforms with mixed communication requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system upgrades needing Modbus connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What backplane is the MVI94-MCM compatible with?\u003c\/strong\u003e  A: It is compatible with the 1794 FLEX I\/O backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What communication standards are supported?\u003c\/strong\u003e  A: RS-232, RS-422, and RS-485.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module provide optical isolation?\u003c\/strong\u003e  A: Yes, the application port offers 500V optical isolation from the backplane.\u003c\/span\u003e\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980168982712,"sku":"MVI94-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI94-MCM-MHI.jpg?v=1773048804"},{"product_id":"mvi69l-mbs-prosoft-compactlogix-modbus-serial-lite-communication-module","title":"MVI69L-MBS | ProSoft | CompactLogix Modbus Serial Lite Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eMVI69L-MBS\u003c\/strong\u003e Modbus Serial Lite Communication Module was developed by ProSoft Technology to provide CompactLogix controllers with streamlined Modbus serial communication capabilities. Although now discontinued, it offered a lightweight solution for applications requiring basic Modbus master\/slave functionality. With a compact form factor and reduced power consumption, the MVI69L-MBS was well-suited for smaller automation systems where full-featured modules were not necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eMVI69L-MBS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ProSoft Technology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Serial Lite Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e CompactLogix\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI69L-MBS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs \/ Machine Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSubcategory:\u003c\/strong\u003e PLC Module \/ Rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.77 lbs (approx. 0.35 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Parameters:\u003c\/strong\u003e 110–115 kbps baud rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlot(s):\u003c\/strong\u003e Single-slot CompactLogix chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightweight Modbus serial communication solution for CompactLogix systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports master\/slave configurations with simplified functionality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design with reduced backplane load\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for applications requiring basic Modbus integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall-scale automation projects requiring Modbus connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration of CompactLogix controllers with Modbus-compatible devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCost-sensitive installations where enhanced modules are not required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the MVI69L-MBS still available?\u003c\/strong\u003e  A: No, this module has been discontinued by the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What baud rate range was supported?\u003c\/strong\u003e  A: 110–115 kbps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What was the typical use case for this module?\u003c\/strong\u003e  A: It was intended for lightweight Modbus serial communication in CompactLogix systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI69E-MBS\u003c\/strong\u003e – Enhanced Modbus Serial Communication Module with expanded features.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52980172423352,"sku":"MVI69L-MBS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69L-MBS.jpg?v=1773049003"},{"product_id":"prosoft-plx31-eip-mbtcp-prolinx-ethernet-ip-to-modbus-tcp-ip-gateway","title":"ProSoft PLX31-EIP-MBTCP ProLinx EtherNet\/IP to Modbus TCP\/IP Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft PLX31-EIP-MBTCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-speed communication gateway that bridges EtherNet\/IP and Modbus TCP\/IP networks. It allows Allen-Bradley Logix processors to exchange data effortlessly with Modbus TCP\/IP devices, such as power meters, VFDs, and flow controllers. This unit stands as a critical integration tool for multi-vendor automation environments. We supply this gateway as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring maximum network uptime and technical compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe PLX31-EIP-MBTCP utilizes a ruggedized hardware platform to maintain high-speed protocol translation under harsh conditions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24VDC nominal (Accepts 10 to 36 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e300 mA @ 24VDC (610 mA maximum at lower voltages)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 80°C (-40°F to 176°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC 60068-2-27 (15G Operational \/ 30G Non-Operational)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC 60068-2-6 (5G @ 10 to 150 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.38 x 1.99 x 4.38 inches (13.67 x 5.05 x 11.13 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePositive, Negative, and GND Terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe gateway operates reliably from -25°C to 70°C. This wide temperature range eliminates the need for expensive cabinet cooling or heating in most outdoor or high-heat manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Mechanical Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified to IEC 60068-2 shock and vibration standards, the PLX31-EIP-MBTCP withstands the physical stress of heavy industrial machinery. It maintains stable connections in applications involving mining equipment, compressors, or vibrating conveyors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Range DC Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe power circuit accepts any voltage between 10 and 36 VDC. This flexibility allows engineers to power the device from 12V battery systems or standard 24V industrial rails without requiring specialized voltage converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint for High-Density Racks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt under 2 inches wide, the module maximizes rail space. This compact profile allows for easy retrofitting into existing overcrowded control panels where space is at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Transparency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PLX31 architecture minimizes data latency during translation. It ensures that critical process variables from Modbus TCP\/IP devices reach the EtherNet\/IP controller fast enough for real-time logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PLX31-EIP-MBTCP act as both a Modbus TCP Client and Server?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The gateway supports simultaneous Client and Server roles. It can actively poll Modbus devices while concurrently serving data to other Modbus Masters or EtherNet\/IP scanners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the best way to mount this unit?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware includes a standard integrated DIN rail clip. Mount the unit vertically and ensure at least 1 inch of clearance above and below the device to facilitate natural convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support Power over Ethernet (PoE)?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The PLX31-EIP-MBTCP requires a dedicated DC power supply connected to the screw terminals (10 to 36 VDC). It does not draw power from the Ethernet cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the protocol mapping?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must use the ProSoft Configuration Builder (PCB) software. This utility allows you to define the internal data map and set up EtherNet\/IP Class 1 or Class 3 messaging for seamless integration with Studio 5000 projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53371800748216,"sku":"PLX31-EIP-MBTCP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBTCP.jpg?v=1776674267"},{"product_id":"prosoft-mvi56e-mnet-controllogix-modbus-tcp-ip-interface-module","title":"ProSoft MVI56E-MNET ControlLogix Modbus TCP\/IP Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a powerful Modbus TCP\/IP communication bridge within the Allen-Bradley ControlLogix platform. It enables ControlLogix processors to interface seamlessly with Modbus TCP\/IP-compatible devices, such as power meters, VFDs, and programmable controllers. By operating as both a Client and a Server, this module centralizes data collection and command distribution across industrial Ethernet networks. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory equipment\u003c\/strong\u003e, ensuring your automation architecture maintains peak data integrity and compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe MVI56E-MNET utilizes the ControlLogix backplane for power while providing dedicated RJ45 ports for high-speed network traffic.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology (for Allen-Bradley Systems)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP (Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA @ 5V DC; 3 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30G (Operating); 50G (Non-Operating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 to 140°F (0 to 60°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Character Scrolling LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLocal or Remote via Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Mode Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports simultaneous Client and Server applications. This allows a single ControlLogix chassis to pull data from field sensors while simultaneously acting as a data provider for an upper-level SCADA system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Remote Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers configure and diagnose the module directly through the dedicated Ethernet port. This eliminates the need for specialized serial cables or local physical access, drastically reducing maintenance time in large-scale facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Status Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated 4-character scrolling LED display provides immediate hardware and network status. Technicians identify IP address conflicts or communication errors at a glance without connecting a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for heavy industrial environments, the module withstands operating shocks up to 30G. This mechanical durability prevents signal loss or hardware failure in high-vibration applications like mining or heavy stamping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Backplane Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the ControlLogix backplane, the module achieves high-speed data transfers between the Modbus network and the PLC tags, ensuring minimal latency for time-critical control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this MVI56E-MNET unit a newer version of the MVI56-MNET?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"E\" stands for Enhanced. The MVI56E-MNET provides superior configuration options, an updated web server, and improved diagnostic tools compared to the legacy non-E version. It serves as a direct functional replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module draws all necessary power directly from the ControlLogix backplane. Ensure your chassis power supply has sufficient overhead for the 800 mA draw at 5V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software do I need to configure the Modbus registers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProSoft provides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft Configuration Builder (PCB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware. This tool allows you to map Modbus registers to ControlLogix tags through a user-friendly interface via the Ethernet port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I swap this module while the PLC is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile ControlLogix supports RIUP (Removal and Insertion Under Power), we recommend stopping the specific communication tasks in the PLC code before swapping to prevent data corruption in the Modbus registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53442026111160,"sku":"MVI56-MNET","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-MNET1.jpg?v=1778140967"},{"product_id":"prosoft-technology-ilx56-pbm-controllogix-profibus-dpv1-master-slave-network-module","title":"ProSoft Technology ILX56-PBM ControlLogix PROFIBUS DPV1 Master \/ Slave Network Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft Technology ILX56-PBM functions as a high-capacity PROFIBUS DPV1 Master\/Slave communication module designed for seamless slot integration into Allen-Bradley ControlLogix backplanes. This intelligent gateway module interfaces ControlLogix Programmable Automation Controllers (PACs) with decentralized PROFIBUS field devices, including variable speed drives, motor starters, instrument transmitters, and remote I\/O blocks. We distribute this network interface module exclusively in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure clean backplane pin contacts, native firmware validation, and immediate high-speed data mapping without field data corruption.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology (Rockwell Automation Partner)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eILX56-PBM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DPV0 \/ DPV1 (Master or Slave Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Data Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5000 Bytes Total Input\/Output Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw (24V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Enclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Ingress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Slot Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOccupies 1 Standard ControlLogix Chassis Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Category Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLCs \/ Machine Control Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Category Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC Communication Module \/ Rack Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs (0.91 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHandles Massive Data Payloads Across Fields:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module architecture processes up to 5000 bytes of cyclic and acyclic parameter data simultaneously. This large memory capacity enables system integrators to aggregate tracking data from multiple dense instrumentation clusters into a single ControlLogix chassis slot, reducing hardware module expenses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProvides Dual Master or Slave Mode Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis single hardware platform acts as either a PROFIBUS Master controlling remote plant sub-networks or as a downstream Slave reporting up to a larger Distributed Control System (DCS). This firmware flexibility simplifies spare parts inventory by consolidating two distinct network functions into one stock component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinisters Safe Maintenance with IP20 Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module faceplate and housing utilize a solid IP20 touch-safe design. This protective layout prevents maintenance technicians from making accidental finger contact with hot electrical terminals during routine system adjustments or adjacent wire routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlines Controller Memory Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module downloads cyclic PROFIBUS data profiles directly into user-defined data tags inside the host ControlLogix processor. This automatic internal tag generation bypasses complex ladder logic configuration routines and shortens commissioning time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run this module as a PROFIBUS DPV1 Master and a DPV0 Slave simultaneously on the same port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. You must configure the physical serial interface port to operate in one specific mode at a time (either as a Master node governing the line or as a single Slave station) within your ProSoft Configuration Builder software settings before linking the module to the active network trunk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this ProSoft communications module an authentic factory-new piece or a refurbished card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product is 100% brand new, authentic, and completely unused factory-original stock. It arrives inside its native manufacturer box with untouched static shielding wrap, factory validation inspection stamps, and pristine edge connectors completely intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation guidelines protect the module from picking up network grounding noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the 2.00 lbs module firmly into the standard 1756 chassis slot until the plastic top and bottom locking tabs click into position. Ensure your 1756 power supply module grounds cleanly to the main enclosure backplate, and connect the PROFIBUS network cable shield securely to the DB9 connector frame to drain away high-frequency electrostatic distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53478728958136,"sku":"ILX56-PBM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/ILX56-PBM.jpg?v=1779098111"},{"product_id":"prosoft-allen-bradley-an-x2-ab-dhrio-controllogix-communication-gateway-module","title":"ProSoft Allen Bradley AN-X2-AB-DHRIO ControlLogix Communication Gateway Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe AN-X2-AB-DHRIO acts as a high-speed communication gateway that bridges modern EtherNet\/IP networks with legacy Allen Bradley Data Highway Plus (DH+) and Remote I\/O (RIO) systems. This module enables newer ControlLogix and CompactLogix controllers to extract data from, or control, legacy PLC-5, SLC 500, PanelView HMIs, and legacy drive systems. It provides a non-disruptive, phased migration path for aging plant floor networks without requiring complete system rewiring or immediate hardware replacement. We guarantee this product arrives in 100% brand new, original factory condition.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology (for Allen Bradley systems)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Module \/ Gateway\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAN-X2-AB-DHRIO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherNet\/IP, Remote I\/O (RIO), Data Highway Plus (DH+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Communication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 x 10\/100 Mbps RJ45 EtherNet\/IP port\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e1 x Remote I\/O (RIO) \/ Data Highway Plus (DH+) port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e57.6 kbaud to 230.4 kbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRack Address Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 76 octal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacity Constraints\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 32 RIO racks\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eUp to 4 EtherNet\/IP drives\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eUp to 8 PanelView HMIs on a single network\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Controllers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix, CompactLogix, PLC-5, SLC 500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Main input) \/ 12 VDC internal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA to 200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower \u0026amp; Thermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.4 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Desktop mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to 85 °C (-40 °F to 185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg (0.69 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhased Legacy Migration Without Downtime:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis gateway eliminates the high risk of \"rip-and-replace\" upgrades. It permits a step-by-step modernization strategy where engineers replace old processors with ControlLogix CPUs while keeping the existing, functional RIO field racks and DH+ infrastructure completely intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Dual-Mount Design for Tight Spaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact housing supports both standard DIN rail clipping inside busy control enclosures and standalone desktop placement. This flexibility allows field engineers to deploy the unit inside crowded terminal boxes right at the legacy machine tap points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeb-Based Diagnostics and Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in RJ45 port hosts an onboard web server. Controls personnel configure network parameters, set baud rates, map rack numbers, and view real-time diagnostics directly via a standard web browser, avoiding the need for specialized, costly programming software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Legacy Device Density Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single gateway manages up to 32 RIO logical racks, up to 8 legacy PanelView terminals, or up to 4 EtherNet\/IP drives simultaneously. This high processing capacity replaces multiple legacy blue-hose scanner modules, drastically reducing cabinet power consumption and heat load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module run both DH+ and Remote I\/O (RIO) protocols at the exact same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The AN-X2-AB-DHRIO contains a single physical legacy port. You must configure the module firmware to operate either as a DH+ bridge or as a Remote I\/O scanner\/adapter during the initial web-based setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this item arrive with a factory warranty and original packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this AN-X2-AB-DHRIO gateway as a 100% brand new, authentic factory unit inside its original manufacturer packaging with all default factory seals intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the node address and network baud rates on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module discards legacy physical DIP switches. You access the configuration interface by typing the default IP address of the gateway into your web browser, which opens the configuration utility to select baud rates (57.6k, 115.2k, or 230.4k) and rack numbers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat external power source does the module require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module runs on a standard 24V DC external power supply. The internal electronics regulate this down to 12V DC with a maximum current draw of 200 mA, yielding a very low 2.4-watt thermal footprint inside your enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53493570437304,"sku":"AN-X2-AB-DHRIO","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AN-X2-AB-DHRIO.jpg?v=1779417964"},{"product_id":"prosoft-technology-mvi46-mcm-modbus-communication-module","title":"Prosoft Technology MVI46-MCM Modbus Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eProsoft Technology MVI46-MCM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI46-MCM\u003c\/strong\u003e Modbus Master\/Slave Network Interface Module, operates as a dedicated hardware component for serial data communication between SLC 500 rack systems and Modbus-compatible external devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI46-MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProsoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs (1.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Data Registers\u003c\/td\u003e\n\u003ctd\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (RS-232\/422\/485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Commands per Port\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network Protocol Conversion Latencies\u003c\/h3\u003e\n\u003cp\u003eThe MVI46-MCM module facilitates deterministic protocol conversion between the SLC 500 backplane and serial field devices. Given the serial nature of Modbus RTU\/ASCII protocols, communication latencies are primarily dictated by the selected baud rate and the volume of polling commands configured via ladder logic. The module supports a maximum of 100 commands per port, and users must account for the overhead of register data transfer through the backplane. Proper management of command polling intervals is required to minimize protocol conversion latencies and prevent scan-time spikes within the PLC processor.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be installed in a remote I\/O rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The MVI46-MCM is strictly compatible with local or extended rack configurations within the 1746 chassis family and does not support remote I\/O rack installations.\u003c\/p\u003e\n\u003cp\u003eQ: Is the configuration port capable of supporting RS-485 communication?\u003c\/p\u003e\n\u003cp\u003eA: No. The dedicated configuration port is exclusively defined as RS-232 and requires the supplied DB-9M cable for physical connection to a programming terminal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Configuration\u003c\/strong\u003e: The module occupies a single slot within the 1746 chassis. Ensure the backplane is de-energized prior to insertion to prevent potential damage to the module bus connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Shielding\u003c\/strong\u003e: When utilizing RS-422 or RS-485 application ports, use shielded twisted-pair cabling. Terminate the cable shield at one end only to mitigate ground loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations\u003c\/strong\u003e: Ensure the installation environment maintains a non-condensing relative humidity between 5% and 95%. Although the module is rated for up to 30 g of operational shock, ensure the chassis is mounted on a vibration-dampened surface to maintain the structural integrity of the backplane connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination\u003c\/strong\u003e: When using multi-drop RS-485 configurations, ensure the end-of-line termination resistors are applied according to the specific impedance requirements of the communication cable to prevent signal reflections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53533573841080,"sku":"MV146-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MV146-MCM.jpg?v=1780284717"},{"product_id":"prosoft-ps69-dps-profibus-dp-v1-slave-communication-module","title":"Prosoft PS69-DPS PROFIBUS DP-V1 Slave Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PS69-DPS\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP Slave Communication Module\u003c\/strong\u003e designed for the \u003cstrong\u003eSchneider Electric Modicon M340\u003c\/strong\u003e PAC platform. It enables seamless integration of M340 controllers into PROFIBUS DP networks, allowing high-speed cyclic data exchange with PROFIBUS DP master devices such as Siemens S7 PLCs, Rockwell ControlLogix systems, and other automation controllers. With support for up to \u003cstrong\u003e244 bytes of input and 244 bytes of output data\u003c\/strong\u003e, this module is ideal for hybrid automation environments requiring cross-brand interoperability.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PS69-DPS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP Slave Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft InRAx for Modicon M340\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0\/V1 Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Exchange:\u003c\/strong\u003e Up to 244 bytes input \/ 244 bytes output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 9.6 kbps to 12 Mbps (auto-detect)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 9-pin D-Sub female (PROFIBUS DP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e 24VDC via M340 rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e LED status indicators (RUN, ERR, COM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless M340 Integration:\u003c\/strong\u003e Plugs directly into Modicon M340 backplane as a native I\/O module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Data Throughput:\u003c\/strong\u003e Supports maximum PROFIBUS DP payload for extensive I\/O mapping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-Baud Detection:\u003c\/strong\u003e Automatically synchronizes with master baud rate from 9.6 kbps to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP-V1 Support:\u003c\/strong\u003e Enables acyclic parameter data exchange and extended diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e PCB software provides graphical network setup and GSD file management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Single-slot module saves valuable rack space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid manufacturing lines with Siemens and Schneider controllers\u003c\/li\u003e\n\u003cli\u003eWater treatment SCADA integrating M340 into PROFIBUS networks\u003c\/li\u003e\n\u003cli\u003eAutomotive assembly lines with multi-vendor PLC platforms\u003c\/li\u003e\n\u003cli\u003eProcess control systems requiring cross-brand I\/O sharing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF M340 rack power before module installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the PS69-DPS into any available I\/O slot on the Modicon M340 rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Connection:\u003c\/strong\u003e Connect the 9-pin D-Sub connector to the PROFIBUS DP network using shielded twisted-pair cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Ensure proper PROFIBUS termination resistors are installed at both ends of the bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSD File:\u003c\/strong\u003e Import the ProSoft GSD file into your PROFIBUS master configuration software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Use ProSoft Configuration Builder to define input\/output data lengths and module parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Setting:\u003c\/strong\u003e Set the PROFIBUS station address via rotary switches or software configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Up \u0026amp; Test:\u003c\/strong\u003e Apply power and verify communication status via diagnostic LEDs and master software\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the PS69-DPS compatible with Modicon M580?\u003c\/strong\u003e\u003cbr\u003e\nA: The PS69-DPS is specifically designed for \u003cstrong\u003eModicon M340\u003c\/strong\u003e racks. For M580 systems, consult ProSoft for compatibility or consider alternative communication solutions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of PS69-DPS modules per M340 rack?\u003c\/strong\u003e\u003cbr\u003e\nA: The number depends on available rack slots and power budget. Each module consumes one slot and standard backplane current.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this module act as a PROFIBUS master?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the PS69-DPS operates as a \u003cstrong\u003ePROFIBUS DP slave only\u003c\/strong\u003e. For master functionality, consider ProSoft PTQ-PDPMV1 or MVI69-PDPMV1 modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support PROFIBUS PA devices?\u003c\/strong\u003e\u003cbr\u003e\nA: The PS69-DPS supports standard PROFIBUS DP. For PA devices, a DP\/PA coupler or link is required.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your M340 rack has available slots and sufficient power capacity before ordering\u003c\/li\u003e\n\u003cli\u003eConfirm your PROFIBUS master supports the GSD file revision provided with the module\u003c\/li\u003e\n\u003cli\u003eUse shielded PROFIBUS cable (Type A) for reliable communication at high baud rates\u003c\/li\u003e\n\u003cli\u003eFor redundant PROFIBUS networks, plan for dual-cable infrastructure and redundant masters\u003c\/li\u003e\n\u003cli\u003eConsider the PS69-DPS-XT extended temperature variant for harsh environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53775952117944,"sku":"PS69-DPS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PS69-DPS_3.png?v=1784182920"},{"product_id":"ptq-pdpmv1-prosoft-rockwell-communication-interface-module","title":"PTQ-PDPMV1 | Prosoft | Rockwell Communication Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PTQ-PDPMV1\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP-V1 Master Network Interface Module\u003c\/strong\u003e designed for \u003cstrong\u003eSchneider Electric Quantum and Unity\u003c\/strong\u003e processor platforms. It enables Quantum PLCs to act as PROFIBUS DP masters, controlling up to \u003cstrong\u003e125 slave devices\u003c\/strong\u003e at speeds up to \u003cstrong\u003e12 Mbps\u003c\/strong\u003e. With support for both DPV0 cyclic data exchange and DPV1 acyclic parameter access, this module provides comprehensive integration of PROFIBUS devices into Modicon control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PTQ-PDPMV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP-V1 Master Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft InRAx for Quantum\/Unity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0 \/ DP-V1 Master\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Slaves:\u003c\/strong\u003e Up to 125 PROFIBUS DP devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 9.6 kbps to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane:\u003c\/strong\u003e Single-slot Quantum backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB) with GSD file import\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDPV1 Services:\u003c\/strong\u003e Class 1 and Class 2 acyclic read\/write\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Extended diagnostic data, alarm handling, live list monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports hot standby configurations (up to 4 modules per rack)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware:\u003c\/strong\u003e Flash-upgradable in the field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull DPV1 Master:\u003c\/strong\u003e Supports both cyclic I\/O and acyclic parameter data exchange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Device Count:\u003c\/strong\u003e Manages up to 125 PROFIBUS slaves from a single Quantum rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated GSD Parser:\u003c\/strong\u003e Automatically configures slave devices from manufacturer GSD files\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Standby Support:\u003c\/strong\u003e Enables redundant PROFIBUS master configurations for critical applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Live list, device status, and alarm monitoring via PCB software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnity Pro Compatible:\u003c\/strong\u003e Seamlessly integrates with Schneider Unity Pro programming environment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation turbine control with distributed I\/O\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas pipeline SCADA with PROFIBUS field instruments\u003c\/li\u003e\n\u003cli\u003eWater treatment plant integration of Siemens drives and sensors\u003c\/li\u003e\n\u003cli\u003eChemical processing with multi-vendor device networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the Quantum rack before module insertion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Install the PTQ-PDPMV1 in any available I\/O slot on the Quantum backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Wiring:\u003c\/strong\u003e Connect the 9-pin D-Sub connector to the PROFIBUS network bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Install termination resistors at both physical ends of the PROFIBUS segment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSD Import:\u003c\/strong\u003e Import slave device GSD files into ProSoft Configuration Builder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e Define slave addresses, I\/O mapping, and DPV1 parameters in PCB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnity Pro Integration:\u003c\/strong\u003e Add the module to your Unity Pro project and map I\/O variables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e If using hot standby, configure primary and backup modules per ProSoft guidelines\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up, verify live list, and confirm cyclic data exchange with all slaves\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PTQ-PDPMV1 and MVI69-PDPMV1?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePTQ-PDPMV1\u003c\/strong\u003e is for \u003cstrong\u003eSchneider Quantum\/Unity\u003c\/strong\u003e platforms, while the \u003cstrong\u003eMVI69-PDPMV1\u003c\/strong\u003e is for \u003cstrong\u003eRockwell CompactLogix\u003c\/strong\u003e. Both offer identical PROFIBUS DP-V1 master functionality on different PLC platforms.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module in a Quantum Hot Standby system?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the PTQ-PDPMV1 supports \u003cstrong\u003ehot standby redundancy\u003c\/strong\u003e configurations with up to 4 modules per rack for enhanced reliability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What cable type is recommended?\u003c\/strong\u003e\u003cbr\u003e\nA: Use \u003cstrong\u003ePROFIBUS Type A shielded twisted-pair cable\u003c\/strong\u003e (purple) for standard installations. Type B is acceptable for shorter runs at lower baud rates.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support PROFINET?\u003c\/strong\u003e\u003cbr\u003e\nA: No, this is a \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e master only. For PROFINET integration, consider ProSoft PLX31-EIP-PND or PLX32-EIP-PND gateways.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your Quantum CPU firmware supports ProSoft communication modules\u003c\/li\u003e\n\u003cli\u003eCalculate total PROFIBUS cable length and ensure it meets baud rate specifications\u003c\/li\u003e\n\u003cli\u003eStock spare GSD files from all slave device manufacturers for quick replacement\u003c\/li\u003e\n\u003cli\u003eFor networks exceeding 32 devices or long cable runs, plan for PROFIBUS repeaters\u003c\/li\u003e\n\u003cli\u003eConsider conformal-coated variant for installations in corrosive atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53775958212792,"sku":"PTQ-PDPMV1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-ADM.png?v=1784182868"},{"product_id":"prosoft-mvi69-pdpmv1-profibus-dpv1-master-module","title":"Prosoft MVI69-PDPMV1 PROFIBUS DPV1 Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69-PDPMV1\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP-V1 Master\/Slave Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation CompactLogix\u003c\/strong\u003e platform. It installs directly into a 1769 CompactLogix rack, enabling CompactLogix controllers to communicate with up to \u003cstrong\u003e125 PROFIBUS DP slave devices\u003c\/strong\u003e at speeds up to \u003cstrong\u003e12 Mbps\u003c\/strong\u003e. Operating as an independent communication co-processor, it offloads PROFIBUS protocol handling from the CompactLogix CPU, ensuring deterministic real-time performance.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI69-PDPMV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP-V1 Master\/Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI69 InRAx for CompactLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Rockwell CompactLogix L2, L3 series; MicroLogix 1100\/1400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0 \/ DP-V1 Master \u0026amp; Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Slaves (Master Mode):\u003c\/strong\u003e 125 devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 9.6 kbps to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 9-pin D-Sub female (PROFIBUS DP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 500 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Buffer:\u003c\/strong\u003e Large read\/write data buffers for high-throughput applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Mode Operation:\u003c\/strong\u003e Configurable as either PROFIBUS DP Master or Slave for flexible network roles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent Processor:\u003c\/strong\u003e Onboard co-processor manages entire PROFIBUS protocol stack, offloading CompactLogix CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Data Mapping:\u003c\/strong\u003e PROFIBUS data mapped directly to CompactLogix tags via simple read\/write operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Communication:\u003c\/strong\u003e 12 Mbps maximum baud rate ensures real-time deterministic data exchange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP-V1 Acyclic:\u003c\/strong\u003e Supports parameter configuration and diagnostic data exchange with intelligent field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e No complex ladder logic required — data exchange via standard tag database\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompactLogix integration of Siemens drives, valves, and remote I\/O\u003c\/li\u003e\n\u003cli\u003ePackaging lines with PROFIBUS-enabled servo controllers\u003c\/li\u003e\n\u003cli\u003eAutomotive body shops with mixed Rockwell\/Siemens control architectures\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems with distributed PROFIBUS motor starters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF CompactLogix rack power before module installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the MVI69-PDPMV1 into any available I\/O slot on the 1769 rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection:\u003c\/strong\u003e Connect the 9-pin D-Sub to the PROFIBUS network using shielded cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Switches:\u003c\/strong\u003e Set the PROFIBUS station address using the rotary switches on the module front\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module to your Studio 5000\/RSLogix 5000 project as a generic 1769 module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Use ProSoft Configuration Builder to define master\/slave mode, baud rate, and device configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTag Mapping:\u003c\/strong\u003e Map PROFIBUS I\/O data to CompactLogix controller tags for seamless program access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up, verify module status LEDs, and confirm data exchange with PROFIBUS devices\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the MVI69-PDPMV1 operate as both master and slave simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the module operates in either \u003cstrong\u003eMaster mode\u003c\/strong\u003e or \u003cstrong\u003eSlave mode\u003c\/strong\u003e per configuration. It cannot perform both roles simultaneously.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this compatible with ControlLogix 5580 (L8x) controllers?\u003c\/strong\u003e\u003cbr\u003e\nA: The MVI69-PDPMV1 is designed for \u003cstrong\u003eCompactLogix L2\/L3\u003c\/strong\u003e and \u003cstrong\u003eMicroLogix 1100\/1400\u003c\/strong\u003e. For ControlLogix 1756 chassis, use the \u003cstrong\u003eMVI56-PDPMV1\u003c\/strong\u003e instead.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many PROFIBUS devices can I connect?\u003c\/strong\u003e\u003cbr\u003e\nA: In Master mode, up to \u003cstrong\u003e125 PROFIBUS DP slaves\u003c\/strong\u003e can be managed, limited by network timing and data payload.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic tools are available?\u003c\/strong\u003e\u003cbr\u003e\nA: ProSoft Configuration Builder provides live list monitoring, device status, error counters, and packet capture for troubleshooting.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your CompactLogix CPU model is in the compatibility list (L2x, L3x series)\u003c\/li\u003e\n\u003cli\u003eEnsure your 1769 rack power supply can deliver 500 mA @ 5VDC for this module\u003c\/li\u003e\n\u003cli\u003eFor ControlLogix 1756 platforms, select MVI56-PDPMV1 instead of MVI69-PDPMV1\u003c\/li\u003e\n\u003cli\u003eUse PROFIBUS connectors with built-in termination switches for easier maintenance\u003c\/li\u003e\n\u003cli\u003ePlan GSD file management carefully — keep backups of all slave device GSD files\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53775958868152,"sku":"MVI69-PDPMV1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI69L-MBS2.jpg?v=1773049004"},{"product_id":"prosoft-mvi56-mnetc-modbus-tcp-ip-multi-client-communication-module","title":"Prosoft MVI56-MNETC Modbus TCP\/IP Multi Client Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-MNETC\u003c\/strong\u003e is a \u003cstrong\u003eModbus TCP\/IP Multi-Client Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. Designed for the 1756 ControlLogix chassis, this module enables ControlLogix PACs to simultaneously operate as both \u003cstrong\u003eModbus TCP Client (Master)\u003c\/strong\u003e and \u003cstrong\u003eServer (Slave)\u003c\/strong\u003e, supporting up to \u003cstrong\u003e30 client connections and 20 server connections\u003c\/strong\u003e. With a 10\/100 Mbps Ethernet port and user-definable memory mapping of up to 5000 registers, it is the ideal solution for integrating Modbus devices into ControlLogix environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56-MNETC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP Multi-Client\/Server Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56 for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45 (auto-crossover)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP Clients:\u003c\/strong\u003e Up to 30 simultaneous connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP Servers:\u003c\/strong\u003e Up to 20 simultaneous connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Mapping:\u003c\/strong\u003e 5000 16-bit registers (user-definable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Function Codes:\u003c\/strong\u003e 01, 02, 03, 04, 05, 06, 15, 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC; 3 mA @ 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e LED indicators + Web server for remote monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Client Architecture:\u003c\/strong\u003e Connect to up to 30 Modbus TCP slave devices simultaneously from one ControlLogix rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Role:\u003c\/strong\u003e Operates as both Client and Server, enabling peer-to-peer communication between PLCs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Data Buffer:\u003c\/strong\u003e 5000-register memory map supports extensive I\/O and data table transfers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Server Diagnostics:\u003c\/strong\u003e Built-in HTTP server provides real-time status monitoring without additional software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCIPconnect Support:\u003c\/strong\u003e Enables remote configuration and diagnostics via EtherNet\/IP or ControlNet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWrite Protection:\u003c\/strong\u003e Hardware jumper prevents unauthorized configuration changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding automation integration of HVAC controllers, VFDs, and power meters\u003c\/li\u003e\n\u003cli\u003eWater\/wastewater SCADA with distributed Modbus TCP RTUs\u003c\/li\u003e\n\u003cli\u003eSolar farm inverter monitoring and control\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas wellhead data aggregation into ControlLogix\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF ControlLogix rack power before installing the MVI56-MNETC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available slot on the 1756-Ax chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to your plant Ethernet network using Cat 5e or better cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module to your project using the ProSoft AOP or generic Ethernet module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Define client connections (IP addresses, function codes, register maps) and server parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTag Mapping:\u003c\/strong\u003e Map Modbus registers to ControlLogix controller tags via the imported L5X routine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Settings:\u003c\/strong\u003e Configure IP address, subnet mask, and gateway via PCB or DHCP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Use ModScan or ModSim utilities to verify Modbus TCP communication before commissioning\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MVI56-MNETC and MVI56E-MNETC?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e is the enhanced version with dual Ethernet ports, higher connection capacity, and improved diagnostics. The \u003cstrong\u003eMVI56-MNETC\u003c\/strong\u003e provides single-port Modbus TCP connectivity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module with CompactLogix?\u003c\/strong\u003e\u003cbr\u003e\nA: No, the MVI56-MNETC is for \u003cstrong\u003eControlLogix 1756\u003c\/strong\u003e racks only. For CompactLogix, use \u003cstrong\u003eMVI69-MNET\u003c\/strong\u003e or \u003cstrong\u003eMVI69-MNETC\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support Modbus RTU over serial?\u003c\/strong\u003e\u003cbr\u003e\nA: The MVI56-MNETC is \u003cstrong\u003eEthernet-only\u003c\/strong\u003e (Modbus TCP). For serial Modbus RTU\/ASCII on ControlLogix, consider \u003cstrong\u003eMVI56-MCM\u003c\/strong\u003e or \u003cstrong\u003eMVI56E-MCM\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I update firmware?\u003c\/strong\u003e\u003cbr\u003e\nA: Firmware updates are performed via the ProSoft Configuration Builder utility or through the module's web interface using a .bin file from ProSoft's website.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCalculate total client connections needed — if exceeding 30, deploy multiple MVI56-MNETC modules\u003c\/li\u003e\n\u003cli\u003eEnsure your 1756 power supply has sufficient 5V capacity (800 mA per module)\u003c\/li\u003e\n\u003cli\u003eUse managed Ethernet switches with IGMP snooping for multicast traffic optimization\u003c\/li\u003e\n\u003cli\u003eFor redundant Ethernet, upgrade to MVI56E-MNETC with dual-port switch capability\u003c\/li\u003e\n\u003cli\u003ePlan IP address allocation carefully to avoid conflicts with HMI, SCADA, and other network devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53775960408248,"sku":"MVI56-MNETC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETC_2_e44e6541-738b-4a54-a681-694e5d439d99.png?v=1784182900"},{"product_id":"prosoft-plx32-eip-pnd-ethernet-ip-to-profinet-device-gateway","title":"Prosoft PLX32-EIP-PND EtherNet\/IP to PROFINET Device Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX32-EIP-PND\u003c\/strong\u003e is a \u003cstrong\u003edual-port EtherNet\/IP to PROFINET Device Gateway\u003c\/strong\u003e that enables seamless bi-directional data exchange between \u003cstrong\u003eRockwell Automation EtherNet\/IP controllers\u003c\/strong\u003e and \u003cstrong\u003eSiemens PROFINET IO controllers\u003c\/strong\u003e. Featuring two independent Ethernet ports with embedded switch functionality, this gateway allows devices on different subnets to communicate transparently. It is ideal for hybrid manufacturing environments integrating Allen-Bradley and Siemens control platforms without complex programming or protocol conversion overhead.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX32-EIP-PND\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to PROFINET Device Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX30 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 2 × 10\/100 Mbps RJ45 (embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Interface:\u003c\/strong\u003e 2 × 10\/100 Mbps RJ45 (embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Role:\u003c\/strong\u003e Adapter (Server) or Scanner (Client)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Role:\u003c\/strong\u003e Device (Slave)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer:\u003c\/strong\u003e Bi-directional, up to 1440 bytes per direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C (standard); -40°C to +75°C (XT variant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, ATEX, IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Port Design:\u003c\/strong\u003e Independent Ethernet switches on both sides enable flexible network topologies and subnet isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Data Mapping:\u003c\/strong\u003e No programming required — data maps directly between EtherNet\/IP tags and PROFINET IO data records\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous Protocols:\u003c\/strong\u003e Acts as EtherNet\/IP Adapter and PROFINET Device simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-MDIX:\u003c\/strong\u003e Automatic crossover detection eliminates need for special Ethernet cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e Built-in HTTP server for real-time status monitoring, packet capture, and firmware updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Option:\u003c\/strong\u003e XT variant available for corrosive or high-humidity environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive assembly lines integrating Rockwell PLCs with Siemens ET200 distributed I\/O\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; beverage packaging with Allen-Bradley controllers and Siemens V90 servo drives\u003c\/li\u003e\n\u003cli\u003ePharmaceutical batch processing with FDA validation requiring mixed-vendor platforms\u003c\/li\u003e\n\u003cli\u003eSteel mill rolling mill automation with mixed Rockwell\/Siemens control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount Gateway:\u003c\/strong\u003e Secure the PLX32-EIP-PND to a DIN rail in an IP20-rated control cabinet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) to the power connector; verify PWR LED illuminates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Side:\u003c\/strong\u003e Connect Port 1 or 2 to your Rockwell EtherNet\/IP network (Stratix switch recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Side:\u003c\/strong\u003e Connect Port 1 or 2 to your Siemens PROFINET network (SCALANCE switch recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Configuration:\u003c\/strong\u003e Use the PLX50 Configuration Utility to set IP addresses for both network interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Define input\/output data blocks mapping EtherNet\/IP assembly instances to PROFINET slots\/subslots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the gateway as a generic EtherNet\/IP module in your ControlLogix project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTIA Portal:\u003c\/strong\u003e Import the GSDML file and add the gateway as a PROFINET device in your Siemens project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Verify data exchange by monitoring tags in Studio 5000 and TIA Portal simultaneously\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PLX31-EIP-PND and PLX32-EIP-PND?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePLX31\u003c\/strong\u003e has \u003cstrong\u003esingle Ethernet ports\u003c\/strong\u003e on each side (simpler topology), while the \u003cstrong\u003ePLX32\u003c\/strong\u003e has \u003cstrong\u003edual Ethernet ports with embedded switches\u003c\/strong\u003e on each side, supporting daisy-chain or ring topologies.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this gateway require programming in the PLC?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the gateway operates transparently. Once configured, data flows automatically between mapped memory areas without ladder logic.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this for safety-rated (PROFIsafe) communication?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the PLX32-EIP-PND does not support PROFIsafe or CIP Safety. It is designed for standard process data exchange only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is VLAN tagging supported?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the gateway supports \u003cstrong\u003eIEEE 802.1Q VLAN tagging\u003c\/strong\u003e for network segmentation and traffic prioritization.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose PLX32 over PLX31 if you need daisy-chain topology or device-level ring (DLR) on either side\u003c\/li\u003e\n\u003cli\u003eVerify your EtherNet\/IP scanner supports the gateway's assembly instance sizes\u003c\/li\u003e\n\u003cli\u003eEnsure your PROFINET controller (S7-1200\/1500, ET200) supports the GSDML file revision\u003c\/li\u003e\n\u003cli\u003eFor installations near welding or chemical processing, order the XT (extended temperature\/conformal coat) variant\u003c\/li\u003e\n\u003cli\u003ePlan data block sizes carefully — larger blocks consume more PLC memory but reduce communication overhead\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776312991928,"sku":"PLX32-EIP-PND","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX32-EIP-MBTCP.png?v=1784182925"},{"product_id":"prosoft-mvi56-afc-advanced-flow-computer-module","title":"Prosoft MVI56-AFC Advanced Flow Computer Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-AFC\u003c\/strong\u003e is an \u003cstrong\u003eAdvanced Flow Computer Module\u003c\/strong\u003e designed for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. It installs directly into a 1756 ControlLogix chassis, providing \u003cstrong\u003eAGA, GPA, ISO, and API-compliant\u003c\/strong\u003e flow calculations for custody transfer and process measurement applications. This module eliminates the need for external flow computers by performing all metering calculations — including orifice, turbine, ultrasonic, and Coriolis meter types — directly on the ControlLogix backplane.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56-AFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Advanced Flow Computer Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56 for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Types:\u003c\/strong\u003e Orifice, nozzle, venturi, turbine, ultrasonic, Coriolis, vortex, PD meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculation Standards:\u003c\/strong\u003e AGA-3, AGA-7, AGA-8, AGA-9, AGA-11, GPA 2172, ISO 5167, API MPMS Chapter 11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun Capacity:\u003c\/strong\u003e Up to 8 meter runs per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB) with flow wizard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Interface:\u003c\/strong\u003e Direct tag mapping to ControlLogix controller tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarming:\u003c\/strong\u003e Configurable high\/low alarms, flow direction, maintenance flags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Flow Computing:\u003c\/strong\u003e Performs all flow calculations on the ControlLogix backplane — no external flow computer required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Standard Compliance:\u003c\/strong\u003e Supports AGA, GPA, ISO, and API standards for global custody transfer acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Meter Types:\u003c\/strong\u003e Handles orifice, turbine, ultrasonic, Coriolis, and other primary devices in one module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Run Support:\u003c\/strong\u003e Up to 8 independent meter runs reduce hardware count in multi-stream applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Data:\u003c\/strong\u003e Flow rates, totals, averages, and diagnostic data available as native ControlLogix tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudit Trail:\u003c\/strong\u003e Event logging and alarm history for regulatory compliance and custody transfer auditing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas custody transfer metering stations\u003c\/li\u003e\n\u003cli\u003eRefinery product flow measurement and allocation\u003c\/li\u003e\n\u003cli\u003eChemical plant reactor feed flow control\u003c\/li\u003e\n\u003cli\u003eWater district billing and consumption monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF ControlLogix rack power before installing the MVI56-AFC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available slot on the 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module to your project using the ProSoft AOP or generic module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Launch ProSoft Configuration Builder and create a new flow computer project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Configuration:\u003c\/strong\u003e Select meter type (orifice, turbine, etc.), pipe diameter, fluid properties, and calculation standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Mapping:\u003c\/strong\u003e Map differential pressure, temperature, and pressure transmitter signals to module input tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Setup:\u003c\/strong\u003e Configure high\/low flow alarms, maintenance flags, and event logging parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownload \u0026amp; Verify:\u003c\/strong\u003e Download configuration to the module and verify flow calculations against hand calculations\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module replace a traditional flow computer?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eYes\u003c\/strong\u003e, the MVI56-AFC performs all flow calculation functions internally, eliminating the need for separate flow computers in most applications while maintaining custody transfer compliance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What transmitter signals does it require?\u003c\/strong\u003e\u003cbr\u003e\nA: The module requires \u003cstrong\u003edifferential pressure, static pressure, and temperature\u003c\/strong\u003e inputs (typically 4–20 mA) mapped through ControlLogix analog input modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for LNG or cryogenic applications?\u003c\/strong\u003e\u003cbr\u003e\nA: The module supports \u003cstrong\u003eAGA-8\u003c\/strong\u003e and \u003cstrong\u003eISO 6976\u003c\/strong\u003e calculations for natural gas. For cryogenic LNG, verify specific fluid property requirements against the module's supported equations of state.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I run multiple meter types simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, each of the \u003cstrong\u003e8 runs\u003c\/strong\u003e can be configured independently with different meter types and calculation standards.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your calculation standard requirements (AGA-3 vs ISO 5167) before configuration\u003c\/li\u003e\n\u003cli\u003eEnsure your ControlLogix analog input modules support the required transmitter resolution (typically 16-bit)\u003c\/li\u003e\n\u003cli\u003eFor multi-run applications, plan tag memory carefully — each run generates multiple status and totalizer tags\u003c\/li\u003e\n\u003cli\u003eConsider redundant transmitter configurations for custody transfer applications per API guidelines\u003c\/li\u003e\n\u003cli\u003eOrder the XT variant for outdoor installations or corrosive environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776371876024,"sku":"MVI56-AFC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-DFCM_r180.png?v=1784182867"},{"product_id":"rockwell-prosoft-ilx34-mbs485-modbus-serial-module","title":"Rockwell Prosoft ILX34-MBS485 Modbus Serial Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft ILX34-MBS485\u003c\/strong\u003e is a \u003cstrong\u003eModbus Serial Communication Module\u003c\/strong\u003e designed for \u003cstrong\u003eRockwell Automation CompactLogix L1 controllers and Point I\/O adapters\u003c\/strong\u003e. It provides a single RS-485 serial port supporting both \u003cstrong\u003eModbus RTU Master and Slave\u003c\/strong\u003e modes, enabling CompactLogix systems to communicate with Modbus RTU devices such as variable frequency drives, motor starters, power meters, and remote terminal units (RTUs). With baud rates up to \u003cstrong\u003e38.4 kbps\u003c\/strong\u003e and support for up to \u003cstrong\u003e247 node addresses\u003c\/strong\u003e, this module is a cost-effective solution for serial device integration.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ILX34-MBS485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus Serial Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft ILX34 for CompactLogix\/Point I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e CompactLogix L1, Point I\/O adapters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e 1 × RS-485 (2-wire or 4-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 2400, 4800, 9600, 19200, 38400 bps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Format:\u003c\/strong\u003e 7 or 8 data bits; 1 or 2 stop bits; None, Even, Odd parity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Modbus RTU (Master or Slave); Modbus ASCII (Slave only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNode Address Range:\u003c\/strong\u003e 1 to 247\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Function Codes:\u003c\/strong\u003e 01, 02, 03, 04, 05, 06, 08, 15, 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Studio 5000 with ProSoft AOI; RSLogix 5000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 70°C (standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Designed for CompactLogix L1 and Point I\/O, minimizing control panel space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Mode:\u003c\/strong\u003e Configurable as Modbus RTU Master or Slave for flexible network roles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Baud Range:\u003c\/strong\u003e Supports both legacy (2400 bps) and modern (38.4 kbps) serial devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Integration:\u003c\/strong\u003e Add-On Instruction (AOI) simplifies configuration and tag mapping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e TX\/RX and status LEDs provide immediate visual communication feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Serial Port:\u003c\/strong\u003e Electrical isolation protects against ground loops and transient voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompactLogix integration of legacy Modbus RTU variable frequency drives\u003c\/li\u003e\n\u003cli\u003eBuilding automation power meter and energy monitoring networks\u003c\/li\u003e\n\u003cli\u003eWater\/wastewater SCADA with distributed Modbus RTU telemetry\u003c\/li\u003e\n\u003cli\u003eMaterial handling conveyor motor control via serial Modbus\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF CompactLogix\/Point I\/O rack power before module installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the ILX34-MBS485 into the appropriate adapter slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Wiring:\u003c\/strong\u003e Connect RS-485 A\/B lines to the terminal block; observe polarity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Install 120 Ω termination resistors at both ends of the RS-485 bus if required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Import the ProSoft AOI and add the module to your I\/O configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter Configuration:\u003c\/strong\u003e Set baud rate, parity, node address, and master\/slave mode via module properties\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTag Mapping:\u003c\/strong\u003e Map Modbus registers to CompactLogix controller tags using the AOI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Use ModScan or similar tool to verify serial communication before full commissioning\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with CompactLogix L2\/L3?\u003c\/strong\u003e\u003cbr\u003e\nA: The ILX34-MBS485 is specifically designed for \u003cstrong\u003eCompactLogix L1 and Point I\/O adapters\u003c\/strong\u003e. For L2\/L3, consider \u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e or \u003cstrong\u003eMVI69-MBS\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this for Modbus ASCII?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the module supports \u003cstrong\u003eModbus ASCII mode\u003c\/strong\u003e in Slave configuration only. RTU mode is recommended for new designs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum cable length?\u003c\/strong\u003e\u003cbr\u003e\nA: RS-485 supports up to \u003cstrong\u003e1,200 meters (4,000 feet)\u003c\/strong\u003e at lower baud rates. Use shielded twisted-pair cable and maintain proper termination.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many devices can I poll as a master?\u003c\/strong\u003e\u003cbr\u003e\nA: As a Modbus RTU Master, the module can communicate with up to \u003cstrong\u003e247 slave devices\u003c\/strong\u003e, though practical limits depend on baud rate and response timeout settings.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your CompactLogix L1 or Point I\/O adapter has available slots before ordering\u003c\/li\u003e\n\u003cli\u003eFor multi-port serial applications, consider MVI69-MCM (dual serial) instead\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cable (Belden 9841 or equivalent) for reliable RS-485 communication\u003c\/li\u003e\n\u003cli\u003ePlan node addressing carefully to avoid conflicts with existing Modbus devices\u003c\/li\u003e\n\u003cli\u003eIf operating in high-RF environments, use ferrite cores on serial cables near the module\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776420405432,"sku":"ILX34-MBS485","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-HARTr180.png?v=1784182870"},{"product_id":"rockwell-prosoft-mvi56-101m-master-communication-module","title":"Rockwell Prosoft MVI56-101M Master Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-101M\u003c\/strong\u003e is an \u003cstrong\u003eIEC 60870-5-101 Master Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. It enables ControlLogix PACs to communicate as \u003cstrong\u003eIEC 60870-5-101 masters\u003c\/strong\u003e with remote terminal units (RTUs), intelligent electronic devices (IEDs), and substation automation equipment over serial communication links. Compliant with the global standard for power utility telecontrol, this module is essential for SCADA integration in electrical utility and energy management applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56-101M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e IEC 60870-5-101 Master Serial Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56 for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e IEC 60870-5-101 (Master, balanced and unbalanced)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 2 × RS-232\/RS-485 (software selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 300 bps to 64 kbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Link Address:\u003c\/strong\u003e 1 to 65534\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Address:\u003c\/strong\u003e 1 to 65534\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInformation Objects:\u003c\/strong\u003e Single-point, double-point, measured value, integrated total, step position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60870-5-101 Compliant:\u003c\/strong\u003e Fully implements the international standard for power system telecontrol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Serial Ports:\u003c\/strong\u003e Two independent channels support redundant communication paths or multiple RTU networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced \u0026amp; Unbalanced:\u003c\/strong\u003e Supports both transmission modes for compatibility with diverse RTU equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive ASDU Support:\u003c\/strong\u003e Handles all standard information objects including single commands, setpoints, and time synchronization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e Supports clock synchronization commands (C_CS ACT) for event timestamp alignment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Tag Mapping:\u003c\/strong\u003e IEC 101 data points map directly to ControlLogix tags for seamless SCADA integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical utility SCADA with remote substation RTUs\u003c\/li\u003e\n\u003cli\u003eRenewable energy farm monitoring (wind, solar) with IEC 101-compliant controllers\u003c\/li\u003e\n\u003cli\u003eWater treatment plant telemetry over serial radio or fiber modems\u003c\/li\u003e\n\u003cli\u003eRailway signaling and traction power monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF ControlLogix rack power before installing the MVI56-101M\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available slot on the 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Connection:\u003c\/strong\u003e Connect RS-232 or RS-485 cables to the serial ports based on RTU requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module to your project and configure the generic module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Define data link addresses, common addresses, ASDU types, and information object addresses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTU Mapping:\u003c\/strong\u003e Map IEC 101 information objects to ControlLogix controller tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Sync:\u003c\/strong\u003e Enable clock synchronization if event timestamping is required by your SCADA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Verify communication using the PCB diagnostic monitor and confirm data exchange with RTUs\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between IEC 60870-5-101 and IEC 60870-5-104?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eIEC 101\u003c\/strong\u003e operates over \u003cstrong\u003eserial communication\u003c\/strong\u003e (RS-232\/485), while \u003cstrong\u003eIEC 104\u003c\/strong\u003e uses \u003cstrong\u003eTCP\/IP over Ethernet\u003c\/strong\u003e. The MVI56-101M is for serial IEC 101 only. For Ethernet IEC 104, consider \u003cstrong\u003eMVI56-104M\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can this module operate as an IEC 101 slave?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003eMVI56-101M\u003c\/strong\u003e is a \u003cstrong\u003eMaster\u003c\/strong\u003e module. For Slave functionality, consult ProSoft for availability or alternative solutions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this suitable for protective relay communication?\u003c\/strong\u003e\u003cbr\u003e\nA: While IEC 101 is primarily for SCADA telecontrol, it can exchange data with protective relays supporting IEC 101 protocol. For dedicated relay protocols (IEC 61850), consider \u003cstrong\u003eMVI56E-61850S\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What cable distance is supported?\u003c\/strong\u003e\u003cbr\u003e\nA: RS-232 supports up to \u003cstrong\u003e15 meters\u003c\/strong\u003e; RS-485 supports up to \u003cstrong\u003e1,200 meters\u003c\/strong\u003e. Use fiber modems or radio links for longer distances.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your RTUs support IEC 60870-5-101 and confirm their data link address range\u003c\/li\u003e\n\u003cli\u003eFor redundant serial paths, use both ports with independent communication channels\u003c\/li\u003e\n\u003cli\u003eEnsure your serial cables are properly shielded and grounded for substation EMI immunity\u003c\/li\u003e\n\u003cli\u003ePlan information object address mapping to avoid overlaps with existing SCADA databases\u003c\/li\u003e\n\u003cli\u003eConsider the XT variant for outdoor cabinet installations subject to temperature extremes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776541614264,"sku":"MVI56-101M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-MCMR_2r180.png?v=1784182857"},{"product_id":"rockwell-prosoft-ilx69-pbs-profibus-slave-communication-module","title":"Rockwell Prosoft ILX69-PBS PROFIBUS Slave Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft ILX69-PBS\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP Slave Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation CompactLogix and MicroLogix\u003c\/strong\u003e platforms. It enables CompactLogix controllers to operate as \u003cstrong\u003ePROFIBUS DP slaves\u003c\/strong\u003e, allowing PROFIBUS DP masters (such as Siemens S7 PLCs or ProSoft master modules) to read and write data from the CompactLogix system. With support for \u003cstrong\u003eDP-V0 cyclic data\u003c\/strong\u003e and \u003cstrong\u003eDP-V1 acyclic messaging\u003c\/strong\u003e, this module provides robust interoperability in mixed-vendor automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ILX69-PBS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft ILX69 for CompactLogix\/MicroLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Rockwell CompactLogix, MicroLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0 \/ DP-V1 Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Connector:\u003c\/strong\u003e 9-pin D-Sub female\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × RJ45 (10\/100 Mbps) for configuration\/diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cyclic Input Data:\u003c\/strong\u003e 244 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cyclic Output Data:\u003c\/strong\u003e 244 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcyclic Data:\u003c\/strong\u003e DPV1 Class 1 read\/write supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Setting:\u003c\/strong\u003e Rotary switches (0–99) or software configuration (0–125)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB); Studio 5000 AOI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e +5VDC via backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 131.6 × 92.1 × 39.3 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 152 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL\/cUL Class 1 Div 2, CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative CompactLogix Integration:\u003c\/strong\u003e Plugs directly into 1769 CompactLogix backplane as standard I\/O module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP-V1 Support:\u003c\/strong\u003e Enables acyclic parameter access and extended diagnostics from PROFIBUS masters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Diagnostics:\u003c\/strong\u003e Dedicated RJ45 port for web-based diagnostics and remote firmware updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Addressing:\u003c\/strong\u003e Rotary switches for quick address assignment or software configuration for addresses above 99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSD Card Slot:\u003c\/strong\u003e Removable memory card stores configuration for rapid field replacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Small footprint ideal for space-constrained control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompactLogix systems integrated into Siemens-dominated PROFIBUS networks\u003c\/li\u003e\n\u003cli\u003eAutomotive plants with mixed Rockwell\/Siemens control architectures\u003c\/li\u003e\n\u003cli\u003ePackaging OEM machines requiring PROFIBUS slave interface for customer integration\u003c\/li\u003e\n\u003cli\u003eProcess skids with CompactLogix controllers interfacing to DCS PROFIBUS masters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the CompactLogix rack before module installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the ILX69-PBS into any available 1769 slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Connection:\u003c\/strong\u003e Connect the 9-pin D-Sub to the PROFIBUS network bus cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Setting:\u003c\/strong\u003e Set the rotary switches to the desired PROFIBUS station address (1–99)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Setup:\u003c\/strong\u003e Connect the RJ45 port to your laptop for initial configuration via web interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the module using the ProSoft AOP or generic 1769 module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Define input\/output data lengths, DPV1 parameters, and module behavior\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSD File:\u003c\/strong\u003e Provide the ProSoft GSD file to your PROFIBUS master system engineer for network integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up and verify cyclic data exchange via master diagnostic tools\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ILX69-PBS operate as a PROFIBUS master?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, this module is a \u003cstrong\u003ePROFIBUS DP slave only\u003c\/strong\u003e. For master functionality on CompactLogix, use \u003cstrong\u003eILX69-PBM\u003c\/strong\u003e or \u003cstrong\u003eMVI69-PDPMV1\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I set an address above 99?\u003c\/strong\u003e\u003cbr\u003e\nA: Set both rotary switches to \u003cstrong\u003e0\u003c\/strong\u003e and configure the address via the \u003cstrong\u003ePCB software or Studio 5000 tag\u003c\/strong\u003e (supports 0–125).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the Ethernet port required for operation?\u003c\/strong\u003e\u003cbr\u003e\nA: No, the Ethernet port is for \u003cstrong\u003econfiguration and diagnostics only\u003c\/strong\u003e. PROFIBUS communication operates independently via the DB9 connector.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this with Micro800 controllers?\u003c\/strong\u003e\u003cbr\u003e\nA: The ILX69-PBS is designed for \u003cstrong\u003eCompactLogix and MicroLogix\u003c\/strong\u003e. For Micro800, consult ProSoft for compatible gateway solutions.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your PROFIBUS master system engineer has the correct GSD file before commissioning\u003c\/li\u003e\n\u003cli\u003eFor redundant PROFIBUS networks, plan for dual-cable infrastructure at the master level\u003c\/li\u003e\n\u003cli\u003eUse the SD card to back up configurations — store spares with pre-loaded configs for rapid replacement\u003c\/li\u003e\n\u003cli\u003eEnsure proper PROFIBUS termination at both ends of the bus segment\u003c\/li\u003e\n\u003cli\u003eConsider ILX69-PBS-XT for installations in hazardous or extreme temperature environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776587194552,"sku":"MVI56-101MILX69-PBS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-PDPMV1_r180.png?v=1784182887"},{"product_id":"plx51-pbm-rockwell-prosoft-profibus-dp-modbus-serial-gateway","title":"PLX51-PBM | Rockwell Prosoft | PROFIBUS DP Modbus Serial Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX51-PBM\u003c\/strong\u003e is a \u003cstrong\u003estand-alone PROFIBUS DPV0\/DPV1 Master or Slave Gateway\u003c\/strong\u003e that bridges \u003cstrong\u003ePROFIBUS DP networks\u003c\/strong\u003e to \u003cstrong\u003eEtherNet\/IP or Modbus (RTU\/TCP)\u003c\/strong\u003e systems. Unlike rack-mounted modules, this DIN-rail gateway operates independently, enabling any EtherNet\/IP scanner or Modbus master to access PROFIBUS devices without PLC backplane constraints. Configurable as either a \u003cstrong\u003ePROFIBUS Master\u003c\/strong\u003e (managing up to 125 slaves) or \u003cstrong\u003eMultiple Slaves\u003c\/strong\u003e, it offers unmatched flexibility for brownfield integration and multi-protocol environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX51-PBM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP Master\/Slave to EtherNet\/IP or Modbus Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX50 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Interface:\u003c\/strong\u003e 1 × RS-485 (DB9 female), DPV0\/DPV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 2 × RJ45 (10\/100 Mbps, embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Interfaces:\u003c\/strong\u003e Modbus TCP\/IP, Modbus RTU-RS232, Modbus RTU-RS485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster Mode:\u003c\/strong\u003e Up to 125 PROFIBUS slaves; 2 KB device\/status data\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlave Mode:\u003c\/strong\u003e Multiple PROFIBUS slave emulation (up to 32 addresses)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 9.6 kbps to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, ATEX, IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Versatility:\u003c\/strong\u003e Bridges PROFIBUS to EtherNet\/IP, Modbus TCP, Modbus RTU-232, or Modbus RTU-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster\/Slave Flexibility:\u003c\/strong\u003e Configurable as PROFIBUS Master or multiple Slaves per application requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet Switch:\u003c\/strong\u003e Dual RJ45 ports enable daisy-chain topology without external switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDPV1 Messaging:\u003c\/strong\u003e Supports acyclic parameter read\/write and alarm handling for intelligent devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacket Capture:\u003c\/strong\u003e Built-in PROFIBUS and Modbus packet capture for advanced troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e HTTP server provides status monitoring, event logs, and firmware update capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrating legacy PROFIBUS devices into modern EtherNet\/IP control architectures\u003c\/li\u003e\n\u003cli\u003eSCADA systems requiring Modbus TCP access to Siemens PROFIBUS field instruments\u003c\/li\u003e\n\u003cli\u003eMigration projects replacing old PLCs while retaining existing PROFIBUS I\/O infrastructure\u003c\/li\u003e\n\u003cli\u003eTest benches and commissioning tools for PROFIBUS device verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Snap the PLX51-PBM onto a standard 35 mm DIN rail in an IP20 cabinet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) to the power connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Wiring:\u003c\/strong\u003e Connect the DB9 port to the PROFIBUS network using shielded cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Connection:\u003c\/strong\u003e Connect RJ45 Port 1 to your EtherNet\/IP network (or Port 2 for daisy-chain)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Connection (if used):\u003c\/strong\u003e Connect serial Modbus devices to the RS-232\/485 terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLX50 Configuration:\u003c\/strong\u003e Install PLX50 Utility, discover the gateway, and select Master or Slave mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSD Management:\u003c\/strong\u003e Import slave device GSD files and configure device parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Map PROFIBUS I\/O data to EtherNet\/IP assembly instances or Modbus registers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Use the utility's live list and diagnostic monitor to verify network health\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the PLX51-PBM operate as both master and slave simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the module operates in either \u003cstrong\u003eMaster mode\u003c\/strong\u003e or \u003cstrong\u003eSlave mode\u003c\/strong\u003e at any given time. Mode selection is made during configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Do I need a PLC to use this gateway?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the PLX51-PBM is a \u003cstrong\u003estand-alone gateway\u003c\/strong\u003e. It can bridge PROFIBUS to EtherNet\/IP or Modbus without any specific PLC backplane requirement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many Modbus TCP connections does it support?\u003c\/strong\u003e\u003cbr\u003e\nA: The gateway supports up to \u003cstrong\u003e40 TCP connections\u003c\/strong\u003e and \u003cstrong\u003e10 CIP connections\u003c\/strong\u003e on the EtherNet\/IP side.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I update firmware in the field?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, firmware updates are performed via the \u003cstrong\u003ePLX50 Configuration Utility\u003c\/strong\u003e or through the web interface using digitally signed firmware files.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose stand-alone PLX51-PBM over rack-mounted modules when you need protocol bridging without PLC dependency\u003c\/li\u003e\n\u003cli\u003eVerify your PROFIBUS network baud rate and ensure all slave devices support the selected rate\u003c\/li\u003e\n\u003cli\u003eFor EtherNet\/IP integration, confirm your scanner supports the gateway's assembly instance sizes\u003c\/li\u003e\n\u003cli\u003eUse the packet capture feature during commissioning to resolve timing or data mismatch issues\u003c\/li\u003e\n\u003cli\u003eOrder the XT variant for installations in extreme temperatures or corrosive atmospheres\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776590504120,"sku":"PLX51-PBM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX51-PBS_2r180.png?v=1784182829"},{"product_id":"plx31-eip-sie-rockwell-prosoft-ethernet-ip-gateway-module","title":"PLX31-EIP-SIE | Rockwell Prosoft | EtherNet\/IP Gateway Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-SIE\u003c\/strong\u003e is an \u003cstrong\u003eEtherNet\/IP to Siemens Industrial Ethernet (S7) Gateway\u003c\/strong\u003e that enables bi-directional data exchange between \u003cstrong\u003eRockwell Automation EtherNet\/IP controllers\u003c\/strong\u003e and \u003cstrong\u003eSiemens S7-series PLCs\u003c\/strong\u003e. Supporting \u003cstrong\u003eS7 Communication over ISO-on-TCP (RFC1006)\u003c\/strong\u003e, this gateway allows ControlLogix and CompactLogix systems to read and write data blocks, process inputs\/outputs, and access markers in Siemens S7-300, S7-400, S7-1200, and S7-1500 controllers without additional middleware or OPC servers.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX31-EIP-SIE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to Siemens S7 Communication Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX30 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens S7 Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45 (ISO-on-TCP \/ RFC1006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS7 Connections:\u003c\/strong\u003e Up to 8 concurrent S7 connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS7 PLC Support:\u003c\/strong\u003e S7-300, S7-400, S7-1200, S7-1500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Areas:\u003c\/strong\u003e DB (Data Blocks), I (Inputs), Q (Outputs), M (Markers), T (Timers), C (Counters)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Buffer:\u003c\/strong\u003e 4 MB shared RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative S7 Protocol:\u003c\/strong\u003e Implements Siemens S7 communication directly — no OPC server or custom software required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-PLC Support:\u003c\/strong\u003e Connects to up to 8 Siemens PLCs simultaneously from one gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Data Mapping:\u003c\/strong\u003e Maps S7 data blocks directly to EtherNet\/IP assembly instances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Performance:\u003c\/strong\u003e Configurable scan intervals as low as 10 ms per connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Single-port design for simple point-to-point or switched network integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e Built-in HTTP server for connection status, error counters, and packet statistics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive manufacturing with Rockwell assembly lines and Siemens welding cells\u003c\/li\u003e\n\u003cli\u003ePower generation with Siemens turbine governors and Rockwell safety systems\u003c\/li\u003e\n\u003cli\u003eWater treatment integrating Siemens S7 pump stations into ControlLogix SCADA\u003c\/li\u003e\n\u003cli\u003ePharmaceutical batch processing with Siemens reactors and Rockwell packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Install the PLX31-EIP-SIE on a 35 mm DIN rail in a control cabinet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) to the power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connection:\u003c\/strong\u003e Connect both RJ45 ports to a common Ethernet switch or separate subnets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS7 PLC Setup:\u003c\/strong\u003e In TIA Portal or STEP 7, enable S7 communication and configure connection resources\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLX50 Configuration:\u003c\/strong\u003e Define S7 PLC IP addresses, TSAPs, and data block mappings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Setup:\u003c\/strong\u003e Configure assembly instance sizes to match mapped S7 data lengths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the gateway as a generic EtherNet\/IP module in your ControlLogix project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Verify data exchange by monitoring mapped tags in Studio 5000 and TIA Portal\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PLX31-EIP-SIE and MVI56E-SIE?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePLX31-EIP-SIE\u003c\/strong\u003e is a \u003cstrong\u003estand-alone DIN-rail gateway\u003c\/strong\u003e bridging EtherNet\/IP to S7. The \u003cstrong\u003eMVI56E-SIE\u003c\/strong\u003e is an \u003cstrong\u003ein-chassis ControlLogix module\u003c\/strong\u003e that performs the same function within the 1756 rack.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the Siemens PLC require special programming?\u003c\/strong\u003e\u003cbr\u003e\nA: Only standard \u003cstrong\u003eS7 communication\u003c\/strong\u003e must be enabled in the Siemens CPU properties. No additional function blocks or programming are required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I access S7-1500 optimized data blocks?\u003c\/strong\u003e\u003cbr\u003e\nA: The gateway accesses \u003cstrong\u003estandard (non-optimized)\u003c\/strong\u003e data blocks. For optimized DBs in S7-1500, create a non-optimized copy or use symbolic access alternatives.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is VLAN tagging supported?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the gateway supports \u003cstrong\u003eIEEE 802.1Q VLAN tagging\u003c\/strong\u003e for network segmentation between IT and OT domains.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose PLX31 for stand-alone installations; choose MVI56E-SIE for in-chassis ControlLogix integration\u003c\/li\u003e\n\u003cli\u003eVerify your Siemens CPU has sufficient S7 connection resources (one per gateway connection)\u003c\/li\u003e\n\u003cli\u003eUse a single subnet if possible to simplify routing; dual subnets require proper gateway configuration\u003c\/li\u003e\n\u003cli\u003ePlan DB numbering carefully — document all accessed data blocks for maintenance reference\u003c\/li\u003e\n\u003cli\u003eFor high-availability systems, deploy redundant gateways with managed switch failover\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776590897336,"sku":"PLX31-EIP-SIE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBS_2.png?v=1784182836"},{"product_id":"plx31-eip-sie-rockwell-prosoft-ethernet-ip-gateway-module-副本","title":"Rockwell Prosoft PLX82-EIP-61850 EtherNet\/IP to IEC 61850 Gateway Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX82-EIP-61850\u003c\/strong\u003e is an \u003cstrong\u003eEtherNet\/IP to IEC 61850 Gateway\u003c\/strong\u003e designed to bridge \u003cstrong\u003eRockwell Automation EtherNet\/IP controllers\u003c\/strong\u003e with \u003cstrong\u003eIEC 61850-compliant intelligent electronic devices (IEDs)\u003c\/strong\u003e in substation automation and power utility applications. It enables ControlLogix and CompactLogix systems to exchange \u003cstrong\u003eMMS (Manufacturing Message Specification)\u003c\/strong\u003e data, \u003cstrong\u003eGOOSE (Generic Object Oriented Substation Events)\u003c\/strong\u003e messages, and \u003cstrong\u003esampled values\u003c\/strong\u003e with protective relays, meters, and bay controllers without requiring dedicated IEC 61850 expertise.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX82-EIP-61850\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to IEC 61850 Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX80 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 2 × 10\/100 Mbps RJ45 (embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61850 Interface:\u003c\/strong\u003e 2 × 10\/100 Mbps RJ45 (embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e IEC 61850-8-1 MMS, GOOSE, ACSI; EtherNet\/IP I\/O \u0026amp; Explicit Messaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical Nodes:\u003c\/strong\u003e GGIO, LLN0, MMXU, CSWI, PTOC, XCBR, and 40+ standard logical nodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOOSE Support:\u003c\/strong\u003e Send\/receive up to 256 GOOSE messages with VLAN priority\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e SNTP \/ IEEE 1588 PTP (SOE resolution ≤ 1 ms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Capacity:\u003c\/strong\u003e 10,000-point register space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility; IEDScout; SCL Manager\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 61850 Ed. 2, CE, UL, cULus, RoHS, IEC 61000-4 (EMC Level 4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIED-Level Integration:\u003c\/strong\u003e Presents ControlLogix data as standard IEC 61850 logical nodes — no custom programming required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance GOOSE:\u003c\/strong\u003e 256 concurrent GOOSE messages with VLAN tagging for protection signaling and interlocking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Time Sync:\u003c\/strong\u003e IEEE 1588 PTP support ensures SOE (Sequence of Events) resolution under 1 millisecond\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Network Isolation:\u003c\/strong\u003e Independent Ethernet switches separate the EtherNet\/IP process network from the IEC 61850 substation LAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCL File Support:\u003c\/strong\u003e Imports ICD\/CID\/SCD files for automatic IED configuration and data object mapping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Features:\u003c\/strong\u003e IP whitelisting, SSL\/TLS encryption, and Syslog audit logging for NERC CIP compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSubstation automation integrating Rockwell PLCs with IEC 61850 protective relays\u003c\/li\u003e\n\u003cli\u003eWind farm SCADA with IEC 61850 turbine controllers and ControlLogix plant control\u003c\/li\u003e\n\u003cli\u003eSolar inverter aggregation via IEC 61850 MMS into EtherNet\/IP DCS networks\u003c\/li\u003e\n\u003cli\u003eHydroelectric governor modernization with mixed IEC 61850 and legacy protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Install the PLX82-EIP-61850 in a substation control cabinet with proper grounding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC) from a substation-grade DC supply (battery-backed preferred)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Network:\u003c\/strong\u003e Connect Port 1\/2 to the plant EtherNet\/IP network (Stratix or equivalent switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61850 Network:\u003c\/strong\u003e Connect Port 1\/2 to the substation IEC 61850 process bus or station bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCL Import:\u003c\/strong\u003e Obtain ICD\/CID files from relay vendors and import into PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLogical Node Mapping:\u0026lt;\/\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776591257784,"sku":"PLX82-EIP-61850","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX82-EIP-PNCr180.png?v=1784182870"},{"product_id":"rockwell-prosoft-mvi56e-sie-industrial-ethernet-client-communication-module","title":"Rockwell Prosoft MVI56E-SIE  Industrial Ethernet Client Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-SIE\u003c\/strong\u003e is a \u003cstrong\u003eSiemens Industrial Ethernet (S7) Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. Installing directly into a 1756 ControlLogix chassis, this module enables ControlLogix PACs to communicate natively with \u003cstrong\u003eSiemens S7-200, S7-300, S7-400, S7-1200, and S7-1500 PLCs\u003c\/strong\u003e using the \u003cstrong\u003eS7 Communication protocol over ISO-on-TCP (RFC1006)\u003c\/strong\u003e. With support for up to \u003cstrong\u003e20 concurrent S7 connections\u003c\/strong\u003e and \u003cstrong\u003e5000 registers\u003c\/strong\u003e of data mapping, it eliminates the need for OPC servers or external gateways in mixed-vendor automation environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56E-SIE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Siemens S7 Industrial Ethernet Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56E Enhanced for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 5570 and later (including 5580 series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Siemens S7 Communication (ISO-on-TCP, RFC1006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ-45 (auto-MDIX)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Connections:\u003c\/strong\u003e Up to 20 concurrent S7 connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Buffer:\u003c\/strong\u003e 5000 16-bit registers; 4 MB shared RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Areas:\u003c\/strong\u003e DB, I, Q, M, T, C (timers\/counters read-only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Interval:\u003c\/strong\u003e Configurable down to 10 ms per connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 4-character alphanumeric scrolling LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e RoHS, CE, IECEx, UL\/cULus\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative S7 Protocol Execution:\u003c\/strong\u003e Full S7 protocol stack onboard — no external gateway or OPC server needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Connection Density:\u003c\/strong\u003e Up to 20 simultaneous S7 connections to distributed Siemens PLCs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Scanning:\u003c\/strong\u003e Independent task scheduling with 10 ms minimum scan interval for real-time performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Logix Integration:\u003c\/strong\u003e Appears as standard 1756 I\/O module with UDTs and diagnostic tags in Studio 5000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Diagnostics:\u003c\/strong\u003e Scrolling 4-character LED display provides real-time connection status and error codes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure \u0026amp; Upgradeable:\u003c\/strong\u003e Supports static IP, VLAN tagging, and field firmware updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive body-in-white integrating Siemens welding robots with Rockwell conveyors\u003c\/li\u003e\n\u003cli\u003ePower plant coordinated control between Siemens turbine governors and Rockwell safety PLCs\u003c\/li\u003e\n\u003cli\u003eWastewater treatment plant SCADA with legacy S7-300 pump stations and new ControlLogix\u003c\/li\u003e\n\u003cli\u003ePharmaceutical batch systems with Siemens reactor controllers and Rockwell packaging lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF ControlLogix rack power before installing the MVI56E-SIE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available non-zero slot on the 1756-Ax chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to your plant network using Cat 5e or better cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module using the ProSoft AOP or generic Ethernet module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS7 PLC Configuration:\u003c\/strong\u003e In TIA Portal\/STEP 7, enable S7 communication and note the TSAP (rack\/slot-based)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Define S7 PLC IP addresses, TSAPs, data block addresses, and scan intervals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTag Mapping:\u003c\/strong\u003e Map S7 data areas to ControlLogix controller tags via the generated L5X routine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Monitor Connection_Status, Error_Code, and Bytes_Transferred tags for health verification\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MVI56E-SIE and PLX31-EIP-SIE?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003eMVI56E-SIE\u003c\/strong\u003e is an \u003cstrong\u003ein-chassis 1756 module\u003c\/strong\u003e for ControlLogix backplane integration. The \u003cstrong\u003ePLX31-EIP-SIE\u003c\/strong\u003e is a \u003cstrong\u003estand-alone DIN-rail gateway\u003c\/strong\u003e for applications without ControlLogix or requiring network separation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I read and write S7-1500 optimized data blocks?\u003c\/strong\u003e\u003cbr\u003e\nA: The MVI56E-SIE accesses \u003cstrong\u003estandard (non-optimized)\u003c\/strong\u003e data blocks. For S7-1500 optimized access, use symbolic addressing alternatives or create non-optimized DB copies.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many data blocks can I access per connection?\u003c\/strong\u003e\u003cbr\u003e\nA: You can define \u003cstrong\u003eup to 256 mixed-type data blocks\u003c\/strong\u003e per connection, supporting BOOL, INT, DINT, REAL, and STRING data types.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a license?\u003c\/strong\u003e\u003cbr\u003e\nA: No additional software license is required beyond the ProSoft Configuration Builder, which is included.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify ControlLogix chassis firmware is version 20 or higher for full MVI56E compatibility\u003c\/li\u003e\n\u003cli\u003eEnsure your 1756 power supply has sufficient 5V capacity (800 mA per MVI56E module)\u003c\/li\u003e\n\u003cli\u003eDocument all TSAP configurations (typically 03.02 for rack 0, slot 2) for each S7 PLC\u003c\/li\u003e\n\u003cli\u003eUse managed Ethernet switches with IGMP snooping for multicast traffic optimization\u003c\/li\u003e\n\u003cli\u003eStock a spare module with identical firmware revision to minimize replacement downtime\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776591749304,"sku":"MVI56E-SIE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETR_2r180.png?v=1784182832"},{"product_id":"mvi56e-61850s-prosoft-server-communication-module","title":"MVI56E-61850S | Prosoft Server Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-61850S\u003c\/strong\u003e is an \u003cstrong\u003eIEC 61850 Server Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation ControlLogix\u003c\/strong\u003e platform. It transforms a ControlLogix PAC into a fully compliant \u003cstrong\u003eIEC 61850 Intelligent Electronic Device (IED)\u003c\/strong\u003e, enabling seamless integration with utility SCADA, energy management systems (EMS), and substation automation networks. Supporting \u003cstrong\u003eMMS, GOOSE, and ACSI services\u003c\/strong\u003e, this module allows non-intelligent electrical equipment (transformers, breakers, switchgear) to present standardized IEC 61850 data models to upper-level systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MVI56E-61850S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e IEC 61850 Server Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56E Enhanced for ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix 1756 chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e IEC 61850-8-1 MMS, GOOSE, ACSI, SCL (ICD\/CID\/SCD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45 (optional SFP fiber)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical Nodes:\u003c\/strong\u003e GGIO, LLN0, MMXU, CSWI, PTOC, XCBR, and 40+ standard nodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOOSE Messages:\u003c\/strong\u003e Send\/receive up to 256 GOOSE messages with VLAN priority\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Capacity:\u003c\/strong\u003e 10,000 16-bit registers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e SNTP \/ IEEE 1588 PTP (SOE resolution ≤ 1 ms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB), IEDScout, SCL Manager\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 800 mA @ 5VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (-XT variant: -25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 61850 Ed. 2, CE, UL, cULus, RoHS, IEC 61000-4 Level 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIED Virtualization:\u003c\/strong\u003e Presents ControlLogix data as standard IEC 61850 logical nodes — no relay programming required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance GOOSE:\u003c\/strong\u003e 256 concurrent GOOSE messages with VLAN tagging and MAC filtering for protection signaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation-Grade Time Sync:\u003c\/strong\u003e IEEE 1588 PTP support delivers ≤ 1 ms SOE resolution for fault analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMassive Data Capacity:\u003c\/strong\u003e 10,000-point register space covers entire 110 kV substation data requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Architecture:\u003c\/strong\u003e Backplane expansion supports up to 4 modules for 500 kV hub-station applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-Click Diagnostics:\u003c\/strong\u003e Built-in web server displays IED tree, GOOSE counters, and MMS session status\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSubstation automation retrofitting legacy transformers and breakers into IEC 61850 SCADA\u003c\/li\u003e\n\u003cli\u003eRenewable energy farm integration (wind\/solar) with utility IEC 61850 control centers\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution with ControlLogix monitoring and IEC 61850 EMS reporting\u003c\/li\u003e\n\u003cli\u003eMicrogrid control with battery energy storage systems (BESS) communicating via IEC 61850\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the ControlLogix rack before installing the MVI56E-61850S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available 1756 slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to the substation station bus or process bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000 Setup:\u003c\/strong\u003e Add the module using the ProSoft AOP and import generated UDTs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogical Node Configuration:\u003c\/strong\u003e In PCB, map ControlLogix tags to IEC 61850 logical nodes (GGIO, MMXU, etc.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOOSE Setup:\u003c\/strong\u003e Configure publisher\/subscriber datasets, VLAN IDs, and AppIDs per substation design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCL Export:\u003c\/strong\u003e Generate ICD\/CID files from PCB and provide to system integrator for SCD compilation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Sync:\u003c\/strong\u003e Configure PTP grandmaster IP or SNTP server for event timestamping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e Enable IP whitelisting and SSL\/TLS encryption per NERC CIP requirements\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module act as an IEC 61850 client?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003eMVI56E-61850S\u003c\/strong\u003e operates as an \u003cstrong\u003eIEC 61850 Server (IED)\u003c\/strong\u003e. For Client\/SCADA master functionality, consult ProSoft for alternative solutions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support IEC 61850-9-2 LE sampled values?\u003c\/strong\u003e\u003cbr\u003e\nA: The MVI56E-61850S primarily supports \u003cstrong\u003eMMS and GOOSE\u003c\/strong\u003e. For \u003cstrong\u003eSampled Values (SV)\u003c\/strong\u003e process bus applications, verify specific firmware support or consult ProSoft.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many logical nodes can I configure per module?\u003c\/strong\u003e\u003cbr\u003e\nA: The module supports \u003cstrong\u003e40+ standard logical node types\u003c\/strong\u003e with a total data capacity of \u003cstrong\u003e10,000 registers\u003c\/strong\u003e, typically sufficient for a complete 110 kV bay.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the failover time for redundant configurations?\u003c\/strong\u003e\u003cbr\u003e\nA: When deployed in dual-module redundant configurations with proper switch configuration, failover times are \u003cstrong\u003e\u0026lt; 50 ms\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWork with your substation design engineer early to define logical node assignments and LNType selections\u003c\/li\u003e\n\u003cli\u003eRequest ICD files from all IED vendors before commissioning to compile the SCD file\u003c\/li\u003e\n\u003cli\u003eUse PTP (not SNTP) if your protection engineer requires SOE resolution under 4 ms\u003c\/li\u003e\n\u003cli\u003ePlan for 4-module expansion if designing a 500 kV hub station with multiple bays\u003c\/li\u003e\n\u003cli\u003eOrder the -XT variant for outdoor installations or substations without HVAC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776593551544,"sku":"MVI56E-61850S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MNETCR_3.png?v=1784182786"},{"product_id":"5201-mnet-mcm-prosoft-modbus-tcp-ip-to-modbus-master-slave-gateway","title":"5201-MNET-MCM | Prosoft Modbus TCP\/IP to Modbus Master\/Slave Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft 5201-MNET-MCM\u003c\/strong\u003e is a \u003cstrong\u003eModular Communication Manager\u003c\/strong\u003e designed for \u003cstrong\u003eRockwell Automation ControlLogix and CompactLogix\u003c\/strong\u003e platforms. This versatile module provides simultaneous \u003cstrong\u003eModbus TCP\/IP and Modbus RTU\/ASCII\u003c\/strong\u003e communication, enabling PLCs to act as both master and slave across multiple networks. With an \u003cstrong\u003eembedded web server\u003c\/strong\u003e for remote configuration and diagnostics, the 5201-MNET-MCM simplifies integration of third-party devices such as drives, meters, and RTUs into Logix environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5201-MNET-MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modular Communication Manager (Modbus TCP\/RTU\/ASCII)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft 5200 Communication Manager\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Rockwell ControlLogix, CompactLogix (via 1756 or 1769 backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e 1 × RS-232 (DB9)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e Modbus TCP\/IP (Master\/Slave), Modbus RTU (Master\/Slave), Modbus ASCII (Master\/Slave), EtherNet\/IP Adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP Clients:\u003c\/strong\u003e Up to 10 simultaneous client connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP Servers:\u003c\/strong\u003e Up to 5 MBAP + 5 encapsulated server connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Serial:\u003c\/strong\u003e Configurable as RS-232 or RS-485 (2-wire\/4-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Web browser, ProSoft Configuration Studio, RSLogix 5000\/Studio 5000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Backplane powered (5VDC\/24VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, FCC, ATEX (model dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Protocol Flexibility:\u003c\/strong\u003e Simultaneous Modbus TCP, RTU, and ASCII support in one module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Master\/Slave:\u003c\/strong\u003e Operates as Modbus Master or Slave on both Ethernet and serial interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Web Server:\u003c\/strong\u003e Configure, monitor, and diagnose via any standard web browser — no specialized software required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Logix Integration:\u003c\/strong\u003e Data maps directly to PLC I\/O data areas (N7, B3, etc.) for immediate program access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Storage:\u003c\/strong\u003e Configuration retained in internal memory across power cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Single-slot module minimizes rack space requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-brand production lines integrating Siemens VFDs, Schneider meters, and Rockwell PLCs\u003c\/li\u003e\n\u003cli\u003eWater treatment SCADA with legacy Modbus RTU telemetry and modern Modbus TCP SCADA\u003c\/li\u003e\n\u003cli\u003eBuilding automation HVAC integration via Modbus serial and Ethernet BMS networks\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas wellhead data aggregation from Modbus RTU flow computers into ControlLogix\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF rack power before installing the 5201-MNET-MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available I\/O slot on the ControlLogix or CompactLogix rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to your plant network using Cat 5e cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Connection:\u003c\/strong\u003e Connect RS-232\/485 serial devices to the DB9 port using appropriate cabling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Configuration:\u003c\/strong\u003e Access the module's default IP via web browser and configure network parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Setup:\u003c\/strong\u003e Define Modbus TCP client\/server settings and serial port parameters (baud, parity, mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Map Modbus registers to PLC data files using the configuration interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the module to your project and reference the mapped data tags in ladder logic\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module with Micro800 controllers?\u003c\/strong\u003e\u003cbr\u003e\nA: The 5201-MNET-MCM is designed for \u003cstrong\u003eControlLogix and CompactLogix\u003c\/strong\u003e platforms. For Micro800, consult ProSoft for compatible communication adapters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support EtherNet\/IP explicit messaging?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the module includes an \u003cstrong\u003eEtherNet\/IP Adapter interface\u003c\/strong\u003e for integration into EtherNet\/IP scanner networks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many serial devices can I connect?\u003c\/strong\u003e\u003cbr\u003e\nA: The single serial port supports \u003cstrong\u003eone RS-232\/485 network\u003c\/strong\u003e. For multi-drop RS-485, up to 247 devices can be addressed via Modbus RTU.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the web interface secure?\u003c\/strong\u003e\u003cbr\u003e\nA: The embedded web server provides configuration and monitoring. For secure environments, deploy behind a firewall or VPN as the module does not support HTTPS natively.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your PLC platform (1756 vs 1769) to ensure correct module ordering\u003c\/li\u003e\n\u003cli\u003eFor applications requiring only Modbus TCP, consider MVI56-MNETC for higher connection counts\u003c\/li\u003e\n\u003cli\u003eUse RS-485 (2-wire) for multi-drop serial networks; RS-232 is limited to point-to-point\u003c\/li\u003e\n\u003cli\u003eDocument all Modbus register maps and device addresses before configuration\u003c\/li\u003e\n\u003cli\u003eConsider the 5201-MNET-MCM-WEB variant for enhanced web server capabilities\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776593748152,"sku":"5201-MNET-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5201-DFNT-MCM_2_6ce24b8b-9d4b-46e6-ae56-2f8ff89e42a9.png?v=1784182923"},{"product_id":"plx31-mbtcp-mbs4-prosoft-modbus-tcp-ip-to-modbus-master-slave-gateway","title":"PLX31-MBTCP-MBS4 | Prosoft Modbus TCP\/IP to Modbus Master\/Slave Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX31-MBTCP-MBS4\u003c\/strong\u003e is a \u003cstrong\u003eModbus TCP\/IP to Modbus Serial (RTU\/ASCII) 4-Port Gateway\u003c\/strong\u003e that enables high-speed bi-directional data transfers between \u003cstrong\u003eModbus TCP\/IP-enabled PACs\/SCADA systems\u003c\/strong\u003e and \u003cstrong\u003eModbus serial devices\u003c\/strong\u003e. Featuring four independent serial ports, this gateway can connect up to \u003cstrong\u003e400 Modbus serial devices\u003c\/strong\u003e (100 per port), dramatically reducing the number of gateways required in large-scale distributed automation systems. It is ideal for SCADA, power monitoring, and building management applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX31-MBTCP-MBS4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modbus TCP\/IP to Modbus Serial 4-Port Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX30 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 4 × RS-232\/RS-485 (software selectable per port)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP:\u003c\/strong\u003e Client (Master) and Server (Slave) modes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Serial:\u003c\/strong\u003e RTU and ASCII (Master or Slave per port)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Device Capacity:\u003c\/strong\u003e Up to 400 devices (100 per port at 32 devices per segment)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +80°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, ATEX, IECEx (model dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Serial Ports:\u003c\/strong\u003e Independent RS-232\/485 ports reduce gateway count and wiring complexity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Device Density:\u003c\/strong\u003e Supports up to 400 serial Modbus devices from a single Ethernet connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Protocol Bridge:\u003c\/strong\u003e Transparently converts Modbus TCP to Modbus RTU\/ASCII without PLC programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Port Configuration:\u003c\/strong\u003e Each port independently configurable as Master or Slave, RTU or ASCII\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e Built-in HTTP server for port status monitoring, traffic statistics, and firmware updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Option:\u003c\/strong\u003e Available for corrosive or high-humidity environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCADA systems polling large numbers of Modbus RTU flow meters and power monitors\u003c\/li\u003e\n\u003cli\u003eBuilding automation integrating legacy Modbus serial HVAC controllers into BACnet\/IP over Modbus TCP\u003c\/li\u003e\n\u003cli\u003eWater\/wastewater treatment with distributed Modbus serial pump controllers and valve actuators\u003c\/li\u003e\n\u003cli\u003eSolar farm inverter monitoring via Modbus RTU serial strings aggregated to central Modbus TCP SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Snap the PLX31-MBTCP-MBS4 onto a 35 mm DIN rail in an IP20 cabinet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) to the power connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to your Modbus TCP\/IP network\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Wiring:\u003c\/strong\u003e Connect Modbus serial devices to Ports 1–4 using shielded twisted-pair cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Install 120 Ω termination resistors at both ends of each RS-485 segment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLX50 Configuration:\u003c\/strong\u003e Define Modbus TCP client\/server settings and serial port parameters (baud, parity, mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Mapping:\u003c\/strong\u003e Map Modbus TCP registers to specific serial ports and slave addresses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Use the web interface to verify communication statistics on all four serial ports\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all four serial ports operate simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eYes\u003c\/strong\u003e, all four ports operate independently and simultaneously, each with its own baud rate and protocol settings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum baud rate per serial port?\u003c\/strong\u003e\u003cbr\u003e\nA: Each serial port supports baud rates up to \u003cstrong\u003e115.2 kbps\u003c\/strong\u003e (standard Modbus RTU limit).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this gateway require a PLC?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the PLX31-MBTCP-MBS4 is a \u003cstrong\u003estand-alone gateway\u003c\/strong\u003e. It bridges Modbus TCP to serial without any PLC backplane requirement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use RS-232 and RS-485 on different ports simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, each port is \u003cstrong\u003eindependently configurable\u003c\/strong\u003e as either RS-232 or RS-485 (2-wire or 4-wire).\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCalculate total serial device count and divide by 100 to determine if one gateway is sufficient\u003c\/li\u003e\n\u003cli\u003eUse RS-485 (2-wire) for multi-drop networks; reserve RS-232 for single point-to-point connections\u003c\/li\u003e\n\u003cli\u003ePlan cable routing to keep each RS-485 segment under 1,200 meters for reliable 9600 bps operation\u003c\/li\u003e\n\u003cli\u003eFor installations near VFDs or welding equipment, use shielded cable with proper grounding\u003c\/li\u003e\n\u003cli\u003eOrder the conformal-coated variant for coastal, chemical, or wastewater treatment environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776594305208,"sku":"MBTCP-MBS4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBS_1_1r180_d246ba2e-5360-46f5-a04d-21dba60e3913.png?v=1784182735"},{"product_id":"prosoft-plx31-eip-pnd-ethernet-ip-to-profinet-io-device-gateway","title":"Prosoft PLX31-EIP-PND EtherNet\/IP to PROFINET IO Device Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX31-EIP-PND\u003c\/strong\u003e is an \u003cstrong\u003eEtherNet\/IP to PROFINET Device Gateway\u003c\/strong\u003e that enables seamless bi-directional data exchange between \u003cstrong\u003eRockwell Automation EtherNet\/IP controllers\u003c\/strong\u003e and \u003cstrong\u003eSiemens PROFINET IO controllers\u003c\/strong\u003e. This compact single-port gateway transparently maps data between EtherNet\/IP assembly instances and PROFINET IO data records, allowing ControlLogix and CompactLogix systems to communicate with Siemens ET200 distributed I\/O, V90 servo drives, and other PROFINET devices without complex programming or protocol expertise.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX31-EIP-PND\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e EtherNet\/IP to PROFINET Device Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX30 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Interface:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Role:\u003c\/strong\u003e Adapter (Server)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Role:\u003c\/strong\u003e Device (Slave)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Transfer:\u003c\/strong\u003e Bi-directional, up to 1440 bytes per direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Protocol Bridge:\u003c\/strong\u003e No programming required — data maps directly between EtherNet\/IP and PROFINET\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Single-Port Design:\u003c\/strong\u003e Cost-effective solution for simple point-to-point or switched network integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Role Operation:\u003c\/strong\u003e Simultaneously presents EtherNet\/IP Adapter data and PROFINET Device data\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-MDIX:\u003c\/strong\u003e Automatic crossover detection eliminates special Ethernet cabling requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e Built-in HTTP server for real-time status monitoring and configuration backup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Option:\u003c\/strong\u003e XT variant available for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive assembly integrating Rockwell PLCs with Siemens ET200SP distributed I\/O\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; beverage packaging with Allen-Bradley controllers and Siemens V90 servo systems\u003c\/li\u003e\n\u003cli\u003ePharmaceutical batch processing requiring mixed-vendor control platform communication\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems with Siemens G120C drives on PROFINET and Rockwell scanners on EtherNet\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Secure the PLX31-EIP-PND to a 35 mm DIN rail in an IP20 control cabinet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) to the power connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Side:\u003c\/strong\u003e Connect the EtherNet\/IP RJ45 to your Rockwell network (Stratix switch recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Side:\u003c\/strong\u003e Connect the PROFINET RJ45 to your Siemens network (SCALANCE switch recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Configuration:\u003c\/strong\u003e Use PLX50 Configuration Utility to assign IP addresses to both network interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Define input\/output data blocks mapping EtherNet\/IP assembly to PROFINET slots\/subslots\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the gateway as a generic EtherNet\/IP module in your ControlLogix project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTIA Portal:\u003c\/strong\u003e Import the GSDML file and add the gateway as a PROFINET device in your Siemens project\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PLX31-EIP-PND and PLX32-EIP-PND?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePLX31\u003c\/strong\u003e has \u003cstrong\u003esingle Ethernet ports\u003c\/strong\u003e for basic point-to-point or switched connections. The \u003cstrong\u003ePLX32\u003c\/strong\u003e has \u003cstrong\u003edual Ethernet ports with embedded switches\u003c\/strong\u003e on each side, supporting daisy-chain or ring topologies.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this gateway require programming in the PLC?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the gateway operates transparently. Once configured, data flows automatically between mapped memory areas without ladder logic.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this for safety-rated (PROFIsafe) communication?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, the PLX31-EIP-PND does not support PROFIsafe or CIP Safety. It is designed for standard process data exchange only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is VLAN tagging supported?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the gateway supports \u003cstrong\u003eIEEE 802.1Q VLAN tagging\u003c\/strong\u003e for network segmentation and traffic prioritization.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose PLX31 for simple star or switched topologies; upgrade to PLX32 for daisy-chain or device-level ring (DLR)\u003c\/li\u003e\n\u003cli\u003eVerify your EtherNet\/IP scanner supports the gateway's assembly instance sizes\u003c\/li\u003e\n\u003cli\u003eEnsure your PROFINET controller (S7-1200\/1500, ET200) supports the GSDML file revision\u003c\/li\u003e\n\u003cli\u003eFor installations near welding or chemical processing, order the XT (extended temperature\/conformal coat) variant\u003c\/li\u003e\n\u003cli\u003ePlan data block sizes carefully — larger blocks consume more PLC memory but reduce communication overhead\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776595058872,"sku":"PLX31-EIP-PND","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX31-EIP-MBTCP1.jpg?v=1776674267"},{"product_id":"plx32-eip-sie-prosoft-communication-gateway-module","title":"PLX32-EIP-SIE Prosoft Communication Gateway Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft PLX32-EIP-SIE\u003c\/strong\u003e is a \u003cstrong\u003edual-port EtherNet\/IP to Siemens Industrial Ethernet (S7) Gateway\u003c\/strong\u003e that enables robust bi-directional data exchange between \u003cstrong\u003eRockwell Automation EtherNet\/IP networks\u003c\/strong\u003e and \u003cstrong\u003eSiemens S7-series PLCs\u003c\/strong\u003e. Featuring \u003cstrong\u003edual embedded Ethernet switches\u003c\/strong\u003e on both sides, this gateway supports daisy-chain, ring, and star topologies while providing network segmentation between EtherNet\/IP and Siemens S7 domains. It is the ideal solution for large-scale hybrid automation systems requiring high-availability communication between Rockwell and Siemens control platforms.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PLX32-EIP-SIE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Dual-Port EtherNet\/IP to Siemens S7 Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft PLX30 Gateway Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Interface:\u003c\/strong\u003e 2 × 10\/100 Mbps RJ45 (embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens S7 Interface:\u003c\/strong\u003e 2 × 10\/100 Mbps RJ45 (embedded switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Siemens S7 Communication (ISO-on-TCP, RFC1006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS7 PLC Support:\u003c\/strong\u003e S7-300, S7-400, S7-1200, S7-1500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Connections:\u003c\/strong\u003e Up to 8 concurrent S7 connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Areas:\u003c\/strong\u003e DB, I, Q, M, T, C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Buffer:\u003c\/strong\u003e 4 MB shared RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft PLX50 Configuration Utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 10–36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cULus, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Port Redundancy:\u003c\/strong\u003e Embedded switches on both sides enable ring topologies and cable redundancy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segmentation:\u003c\/strong\u003e Physically separates EtherNet\/IP process control network from Siemens S7 engineering network\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative S7 Protocol:\u003c\/strong\u003e Full ISO-on-TCP implementation — no OPC server, middleware, or custom programming required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-PLC Connectivity:\u003c\/strong\u003e Up to 8 simultaneous S7 connections to distributed Siemens controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Performance:\u003c\/strong\u003e Configurable scan intervals as low as 10 ms for real-time process synchronization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb-Based Diagnostics:\u003c\/strong\u003e Built-in HTTP server for connection monitoring, error logging, and remote firmware updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge automotive plants with Rockwell assembly lines and Siemens body-in-white welding controllers\u003c\/li\u003e\n\u003cli\u003ePower generation with Siemens DCS turbine control and Rockwell BOP (Balance of Plant) systems\u003c\/li\u003e\n\u003cli\u003eSteel mill hot rolling with Siemens drive systems and Rockwell Level 2 process control\u003c\/li\u003e\n\u003cli\u003eChemical processing with Siemens S7-400 safety systems and Rockwell batch management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Install the PLX32-EIP-SIE on a 35 mm DIN rail with proper chassis grounding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Apply 24VDC (10–36VDC range) from an industrial-grade power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Network:\u003c\/strong\u003e Connect Port 1\/2 to your Rockwell EtherNet\/IP network (Stratix or DLR-capable switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens S7 Network:\u003c\/strong\u003e Connect Port 1\/2 to your Siemens Industrial Ethernet (SCALANCE or equivalent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Configuration:\u003c\/strong\u003e Use PLX50 Configuration Utility to set IP addresses, subnet masks, and gateways for both networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS7 PLC Setup:\u003c\/strong\u003e In TIA Portal\/STEP 7, enable S7 communication and configure TSAPs for each connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Define S7 data block addresses and map to EtherNet\/IP assembly instances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the gateway as a generic EtherNet\/IP module with matching assembly sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Testing:\u003c\/strong\u003e If using ring topology, verify RSTP or DLR failover by disconnecting one cable\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between PLX31-EIP-SIE and PLX32-EIP-SIE?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003ePLX31\u003c\/strong\u003e has \u003cstrong\u003esingle Ethernet ports\u003c\/strong\u003e for basic point-to-point or switched connections. The \u003cstrong\u003ePLX32\u003c\/strong\u003e has \u003cstrong\u003edual embedded switches\u003c\/strong\u003e on each side, supporting daisy-chain, ring, and redundant network architectures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use Device Level Ring (DLR) on the EtherNet\/IP side?\u003c\/strong\u003e\u003cbr\u003e\nA: The PLX32-EIP-SIE supports \u003cstrong\u003elinear and star topologies\u003c\/strong\u003e via its embedded switch. For full DLR beacon-based ring support, verify specific firmware capabilities or use a Stratix switch for DLR management.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this support Siemens S7-1500 R\/H redundant systems?\u003c\/strong\u003e\u003cbr\u003e\nA: The gateway can connect to \u003cstrong\u003eS7-1500 R\/H systems\u003c\/strong\u003e by configuring separate connections to each redundant CPU. Consult ProSoft for specific R\/H integration guidelines.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is there a limit to data block size per connection?\u003c\/strong\u003e\u003cbr\u003e\nA: The gateway supports large data transfers, but practical limits depend on S7 PDU size (typically \u003cstrong\u003e240–960 bytes\u003c\/strong\u003e per request depending on CPU model). Split large data sets across multiple connections if needed.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose PLX32 over PLX31 if your network architecture requires daisy-chaining or cable redundancy\u003c\/li\u003e\n\u003cli\u003eVerify your S7-1500 CPUs have sufficient S7 connection resources (one per gateway connection)\u003c\/li\u003e\n\u003cli\u003eUse managed switches with IGMP snooping if multicast traffic (e.g., Profinet mDNS) is present\u003c\/li\u003e\n\u003cli\u003ePlan IP address schemes to avoid conflicts between EtherNet\/IP and Siemens S7 subnets\u003c\/li\u003e\n\u003cli\u003eFor high-availability applications, deploy redundant PLX32 gateways with HSR\/PRP or managed switch failover\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776595091640,"sku":"PLX32-EIP-SIE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PLX32-EIP-SIE_2.png?v=1784182924"},{"product_id":"mvi56e-mcmxt-prosoft-technology-modbus-master-slave-enhanced-comm-module","title":"MVI56E-MCMXT | Prosoft Technology Modbus Master\/Slave Enhanced Comm Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-MCMXT\u003c\/strong\u003e is an \u003cstrong\u003eenhanced Modbus Master\/Slave Communication Module\u003c\/strong\u003e designed for the \u003cstrong\u003eRockwell Automation ControlLogix platform\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Enhanced Modbus Master\/Slave Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft MVI56E (Logix-XT™)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Allen-Bradley ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e 2 independently configurable (RS-232\/RS-485\/RS-422)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Modbus RTU, Modbus ASCII\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Configuration:\u003c\/strong\u003e Each port can be Master or Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Capacity:\u003c\/strong\u003e 10,000 16-bit registers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Integration:\u003c\/strong\u003e Modbus data appears as I\/O data to ControlLogix processor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Storage:\u003c\/strong\u003e RSLogix\/Studio 5000 (no additional software required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 4-character scrolling alphanumeric LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscovery Service:\u003c\/strong\u003e ProSoft Discovery Service (PDS) for automatic IP assignment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Yes (for harsh\/corrosive environments)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Extended range (higher than standard MVI56E-MCM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackward Compatibility:\u003c\/strong\u003e Compatible with MVI56 modules (no program changes required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 800 mA @ 5V DC (backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature (Standard):\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 142 mm × 30 mm × 133 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, cUL, RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Independent Ports:\u003c\/strong\u003e Two serial ports can operate on same or different Modbus networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Master\/Slave Configuration:\u003c\/strong\u003e Each port independently configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Data Database:\u003c\/strong\u003e 10,000-word database for extensive device data collection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXT Extended Temperature:\u003c\/strong\u003e Conformal coating and wider temperature range for extreme environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless ControlLogix Integration:\u003c\/strong\u003e Modbus data mapped directly to processor I\/O tags\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Configuration:\u003c\/strong\u003e Configuration stored in RSLogix\/Studio 5000 project\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackward Compatible:\u003c\/strong\u003e Drop-in replacement for MVI56-MCM without program changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess control in harsh chemical environments\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas field automation\u003c\/li\u003e\n\u003cli\u003eOutdoor SCADA installations\u003c\/li\u003e\n\u003cli\u003ePower generation in extreme climates\u003c\/li\u003e\n\u003cli\u003eMarine and offshore platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall in single 1756 ControlLogix slot (local or remote rack)\u003c\/li\u003e\n\u003cli\u003eConnect serial cables to Port 1 and\/or Port 2\u003c\/li\u003e\n\u003cli\u003eConfigure port parameters (baud rate, parity, protocol) via Studio 5000\u003c\/li\u003e\n\u003cli\u003eSet Master\/Slave mode per port\u003c\/li\u003e\n\u003cli\u003eMap Modbus registers to ControlLogix I\/O tags\u003c\/li\u003e\n\u003cli\u003eVerify communication via LED status indicators\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MVI56E-MCM and MVI56E-MCMXT?\u003c\/strong\u003e\u003cbr\u003eA: MVI56E-MCM is for standard process applications; MVI56E-MCMXT has conformal coating and extended temperature range for harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require additional configuration software?\u003c\/strong\u003e\u003cbr\u003eA: No. Configuration is stored in the RSLogix\/Studio 5000 project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I replace an MVI56-MCM with MVI56E-MCMXT?\u003c\/strong\u003e\u003cbr\u003eA: Yes, all MVI56E products are backward compatible with MVI56 modules.\u003c\/p\u003e\n\u003ch3\u003eModel Selection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMVI56E-MCMXT = \u003cstrong\u003eExtended Temperature Modbus Module\u003c\/strong\u003e for harsh environments\u003c\/li\u003e\n\u003cli\u003eFor standard environments, use MVI56E-MCM (lower cost)\u003c\/li\u003e\n\u003cli\u003eFor Modbus TCP\/IP, use MVI56E-MNETC or MVI56E-MNETCR\u003c\/li\u003e\n\u003cli\u003eVerify ControlLogix firmware compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53800507506872,"sku":"MVI56E-MCMXT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56E-MCMXT_b4660f7a-cd82-4815-bb96-a1bc8d77afdb.png?v=1784796181"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/prosoft.oembed?page=3","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}