{"title":"Yokogawa Power Supply \u0026 Battery","description":"\u003cp\u003eSystem uptime begins with stable power. This category focuses on the essential power infrastructure for Yokogawa DCS racks and modules. We offer a selection of Power Supply Units (PSU) designed for clean, redundant power delivery to sensitive control hardware, as well as the specialized backup batteries required to maintain system memory and configuration during power fluctuations. Given the critical role these components play in preventing data loss and hardware resets, we prioritize units that meet Yokogawa’s strict voltage regulation and heat dissipation standards, providing a secure foundation for your entire automation rack.\u003c\/p\u003e","products":[{"product_id":"pw484-51-yokogawa-centum-cs-3000-power-supply-new-japan","title":"PW484-51 | Yokogawa CENTUM CS 3000 Power Supply New Japan","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa PW484-51 S1 CENTUM VP 24V DC Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-51 (Model: PW484-51)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized power supply module engineered for the Yokogawa CENTUM VP and CS 3000 Distributed Control Systems (DCS). Operating as a core infrastructure component, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-51 (Style S1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts input power into highly stable, regulated 24V DC to energize control processors, I\/O modules, and complex communication interfaces.\u003c\/p\u003e\n\u003cp\u003eThis \"S1\" hardware revision represents an updated design over the legacy PW484-50, offering improved component longevity and thermal efficiency. The module is built for mission-critical reliability, supporting dual-redundant configurations. In a duplex setup, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-51 (Part Number: PW484-51)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules share the system load; if one fails, the partner module assumes full power delivery instantaneously, ensuring zero process downtime. Note that this specific unit is provided without the front cover, making it ideal for integration into existing secured racks or for specific maintenance replacements where the original cover is retained.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-51 (Model: PW484-51)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the robust electrical foundation required for high-availability industrial automation.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 313.501px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003ePW484-51\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eStyle Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eStyle S1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eRegulated DC for system backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eUp to 5 A continuous (load dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eDual-redundant \"Pair \u0026amp; Spare\" support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003e\u0026gt;85% typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eOvervoltage, overcurrent, and short-circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eHRDY, ALM, and Status LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003e900g (0.9 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 27.7254%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2212%; height: 19.5938px;\"\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505413746872,"sku":"PW484-51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/12._f7879e5f-d8c3-43fa-96e9-dc0cc4730827.jpg?v=1769496383"},{"product_id":"yokogawa-nfpw444-50-part-nfpw444-50-redundant-dcs-power","title":"Yokogawa NFPW444-50 Part # NFPW444-50 | Redundant DCS Power","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa NFPW444-50 24V DC Field Control Station Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50 (Model: NFPW444-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency DC-to-DC power supply module designed for Yokogawa’s CENTUM VP and CS 3000 Field Control Stations (FCS). Specifically engineered to accept a 24 V DC input, this module is critical for industrial sites utilizing centralized battery backup systems or DC power grids. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50 (Part Number: NFPW444-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a highly stable +5.1 V DC output to energize control processors and internal communication circuitry, ensuring deterministic system performance.\u003c\/p\u003e\n\u003cp\u003eAs a \"Basic Type\" with the -50 suffix, this module is designed for standard industrial environments where explosion protection is not required. It is built for high-availability architectures, supporting dual-redundant configurations. In redundant mode, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50 (Model: NFPW444-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules share the load across the backplane; if a failure is detected in one unit, the second module assumes the full 7.8 A rated current load without a voltage dip, preventing volatile memory loss or processor resets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50 (Model: NFPW444-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers precise voltage regulation and robust current delivery for critical DCS infrastructure.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 316.501px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 22.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 22.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 22.5938px;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Supply Module (24 V DC Input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e21.6 V to 31.2 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e+5.1 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e0 to 7.8 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003eDual redundant operation supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eExplosion Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003eNone (Standard Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003eNatural convection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 19.5938px;\"\u003e\u003cspan\u003e0.6 kg (Net) \/ 1.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 47.6294%; height: 39.1875px;\"\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e W \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.3172%; height: 39.1875px;\"\u003e\u003cspan\u003e13.0 cm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 4.97 cm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 14.65 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505428721848,"sku":"NFPW441-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/13._29c48c7a-1b46-430e-8e1b-eb244b6188bc.jpg?v=1769496648"},{"product_id":"yokogawa-spw481-53-power-module-style-s1-g3-conformal","title":"Yokogawa SPW481-53 Power Module | Style S1 G3 Conformal","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa SPW481-53 Style S1 100-120V AC Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW481-53 (Model: SPW481-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized system power supply module engineered for Yokogawa’s CENTUM VP and CS 3000 Distributed Control Systems (DCS). Specifically designed for 100-120V AC input environments, this module provides the regulated DC power necessary to drive control processors, I\/O modules, and communication interfaces within a Field Control Station (FCS).\u003c\/p\u003e\n\u003cp\u003eAs a premium hardware revision, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW481-53 (Part Number: SPW481-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to ISA Standard G3 specifications, featuring conformal coating for protection against corrosive gases. It also supports an extended operating temperature range from -20°C to 70°C, making it suitable for remote instrument enclosures and harsh industrial climates. To ensure mission-critical uptime, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW481-53 (Model: SPW481-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 1:1 dual-redundant configurations, allowing for bumpless power failover in the event of a module or source failure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW481-53 (Model: SPW481-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines environmental resilience with high-precision voltage regulation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSPW481-53\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyle Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyle S1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–120 V AC (Range: 80–132 V AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 (Conformal Coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C (Extended Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports dual redundant operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage, overcurrent, and short-circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-panel LEDs (Power, Alarm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;85% typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg (Net) \/ 1.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505440649400,"sku":"SPW481-53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/14._0536ca89-cb2a-4d4a-9926-f9648e6bc6f2.jpg?v=1769497060"},{"product_id":"pw302-yokogawa-100-240v-ac-redundant-dcs-power-supply","title":"PW302 Yokogawa | 100-240V AC Redundant DCS Power Supply","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eYokogawa PW302 CENTUM CS 3000 \/ VP Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePW302 (Model: PW302)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a foundational power supply unit engineered for Yokogawa’s CENTUM CS 3000 and CENTUM VP Distributed Control Systems (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is responsible for converting universal AC input into a stable,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eregulated DC voltage to power the control processors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eI\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand internal bus communication interfaces within the Field Control Station (FCS).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIn mission-critical industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epower stability is paramount.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePW302 (Part Number: PW302)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeatures an advanced circuit design that filters electrical noise and protects downstream sensitive electronics from voltage surges and short circuits.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically designed to support 1:\u003c\/span\u003e\u003cspan class=\"\"\u003e1 dual-redundant configurations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen two\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePW302\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emodules are installed in a redundant rack,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethey perform active load-sharing; if one unit fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe other assumes the full load instantaneously without a dip in output voltage,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring the DCS remains operational without process interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePW302 (Model: PW302)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high efficiency and long-term reliability in continuous-process industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePW302\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM CS 3000 \/ CENTUM VP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 V AC (Range: 80–264 V AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Regulated internal bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5 A continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;85% typical at full load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant \"Pair \u0026amp; Spare\" support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage, overcurrent, and thermal shutdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 150 mm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505442287800,"sku":"PW302","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/15._d5dd4b3d-8c7f-4046-8a30-b845626c925d.jpg?v=1769497430"},{"product_id":"yokogawa-pw502-power-module-style-s1-100-240v-ac-psu","title":"Yokogawa PW502 Power Module | Style S1 100-240V AC PSU","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa PW502 Style S1 CENTUM VP Power Supply Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW502 (Model: PW502)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability power supply module specifically engineered for Yokogawa’s CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). As a critical infrastructure component within the Field Control Station (FCS), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW502 (Style S1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides regulated DC power to control processors, I\/O modules, and bus repeaters, ensuring deterministic system performance in mission-critical automation environments.\u003c\/p\u003e\n\u003cp\u003eDesigned for maximum uptime, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW502 (Part Number: PW502)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports dual-redundant configurations. In a duplex setup, two modules operate in parallel to share the load; should one unit detect an internal fault or loss of input voltage, the secondary unit assumes the full load instantaneously without any interruption to the process. This \"bumpless\" transition is vital for industries such as oil refining, chemical processing, and power generation, where even a momentary power dip can lead to costly system trips.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW502 (Model: PW502)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines a compact modular footprint with robust electrical protection and high efficiency.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePW502\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyle Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyle S1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Unit for Repeater \/ FCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 V AC (Universal Input, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Regulated Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5 A continuous (load dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Dual-Redundant (Primary\/Backup) Operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;85% typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage, Overcurrent, Short-circuit, and Thermal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Convection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 cm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 12.7 cm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 20.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg (Note: Corrected industrial weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505460768952,"sku":"PW502","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/16._2c871772-7075-4c9b-ba33-7cc12e55161b.jpg?v=1769497801"},{"product_id":"pw482-11-yokogawa-100-240vac-redundant-dcs-power-supply","title":"PW482-11 Yokogawa | 100-240VAC Redundant DCS Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa PW482-11 CENTUM VP \/ CS 3000 Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-11 (Model: PW482-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability power supply unit specifically designed for Yokogawa’s CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module serves as a cornerstone of the Field Control Station (FCS), converting universal AC input into stable, regulated DC power required to drive control processors, I\/O modules, and system communication interfaces.\u003c\/p\u003e\n\u003cp\u003eAs an advanced hardware revision over the legacy PW482-10, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-11 (Part Number: PW482-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures improved component longevity and thermal management. It is engineered for mission-critical availability, supporting 1:1 dual-redundant configurations. In a redundant setup, if one\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-11 (Model: PW482-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efails or loses input power, the partner module assumes the full load instantaneously with a \"bumpless\" transition, ensuring no disruption to real-time process control or data integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-11 (Model: PW482-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates robust electrical protection with universal input flexibility for global industrial standards.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePW482-11\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated DC power for Processors \u0026amp; I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 V AC (Universal, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.3 A (Typical @ 60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5 A (Continuous, load dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports dual redundant (Duplex) operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;85% typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage, overcurrent, and thermal protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 cm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 2.5 cm \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e 20.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5–0.8 kg (Net)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505472401592,"sku":"PW482-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/17._70de838a-8401-4e41-a750-b077af72841b.jpg?v=1769498060"},{"product_id":"yokogawa-pw482-50-part-pw482-50-redundant-psu-module","title":"Yokogawa PW482-50 Part # PW482-50 | Redundant PSU Module","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa PW482-50 Style S2 CENTUM VP Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-50 (Model: PW482-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability power supply module specifically engineered for the Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module serves as a critical electrical regulator for the Field Control Station (FCS), converting AC input into the stabilized DC power necessary to drive control processors, I\/O modules, and internal communication bus architectures.\u003c\/p\u003e\n\u003cp\u003eAs an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS2 hardware style revision\u003c\/strong\u003e, this module represents an optimized design over legacy versions, offering improved thermal resilience and component longevity. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-50 (Part Number: PW482-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis particularly valued for its wide temperature operational capacity, supporting stable performance in environments ranging from -20°C to 70°C. To ensure mission-critical system uptime, it supports 1:1 dual-redundant configurations, allowing for a bumpless power failover that prevents process interruption or volatile memory loss in the event of a module failure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW482-50 (Model: PW482-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines wide-range input flexibility with industrial-grade protection logic.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 354.688px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003ePW482-50\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eHardware Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eStyle S2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 21.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 21.5938px;\"\u003e\u003cspan\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 39.1875px;\"\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 39.1875px;\"\u003e\u003cspan\u003e220–240 V AC (Standard) \/ 100–240 V AC (Universal support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003e24 V DC (Regulated Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 39.1875px;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 39.1875px;\"\u003e\u003cspan\u003e-20°C to +70°C (Extended range version)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003eUp to 5 A continuous (load dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003e\u0026gt;85% typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eProtection Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003eOvervoltage, Overcurrent, Short-circuit, and Thermal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003eDual redundant operation supported (Pair \u0026amp; Spare)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003e800g (Net) \/ 2.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 28.7483%; height: 19.5938px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.1983%; height: 19.5938px;\"\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52505509396664,"sku":"PW482-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/18._c6b3114a-26a9-491c-aee0-cc7f2ce981e2.jpg?v=1769498481"},{"product_id":"yokogawa-aai143-part-aai143-s00-16-ch-analog-input","title":"Yokogawa AAI143 Part # AAI143-S00 | 16-CH Analog Input","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa AAI143-S00 16-Channel Isolated Analog Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143-S00 (Model: AAI143)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module designed for Yokogawa’s CENTUM VP, CENTUM CS 3000, and ProSafe-RS control systems. Engineered as a standard type acquisition unit, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143-S00 (Order Number: AAI143-S00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 16 isolated channels for processing 4 to 20 mA DC signals from field transmitters. This module is essential for precise monitoring of critical process variables such as pressure, temperature, and flow in high-availability industrial environments.\u003c\/p\u003e\n\u003cp\u003eWhat distinguishes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143-S00 (Part Number: AAI143-S00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its robust galvanic isolation and high-speed data update period of 10 ms, which ensures that the DCS (Distributed Control System) receives real-time, interference-free data. The module supports both 2-wire and 4-wire transmitter configurations, adjustable via on-board pins for each individual channel. With an accuracy of ±16 µA and a withstanding voltage of 1500 V AC, it represents Yokogawa’s commitment to Expertise and Reliability (E-E-A-T) in process automation and safety instrumented systems (SIS).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143-S00 (Model: AAI143-S00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-density I\/O nodes, delivering stable transmitter power and rapid signal conversion.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAAI143-S00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CS 3000 \/ ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Module (Standard Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels, Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±16 µA (±0.1% of full scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.0 V or higher (at 20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower ON: 270–350 Ω; Power OFF: ≥ 500 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC for 1 minute (Input to System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllowable Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 mA (5 V DC), 540 mA (24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Drift\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±16 µA \/ 10 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (Net) \/ 4.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure clamp, MIL connector, or KS1 dedicated cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52511024185528,"sku":"AAI143-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/20._44fa1af0-01b9-4a81-a966-c3935a1464a7.jpg?v=1769667478"},{"product_id":"spw482-53-yokogawa-dcs-rack-mount-240w-power-supply","title":"SPW482-53 | Yokogawa DCS Rack-Mount 240W Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa SPW482-53 Power Supply Module 220-240V AC for CENTUM VP\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW482-53 (Model: SPW482)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability power supply module engineered for the Yokogawa CENTUM VP and CS 3000 distributed control systems (DCS). Serving as a critical backbone for system stability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW482-53 (Order Number: SPW482-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts standard 220–240 V AC utility power into a regulated DC output required by system node racks and high-density I\/O modules. This unit is specifically designed for 24\/7 continuous operation in mission-critical industrial sectors, including oil and gas refining, chemical processing, and power generation.\u003c\/p\u003e\n\u003cp\u003eAdhering to strict industrial standards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW482-53 (Part Number: SPW482-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures built-in redundancy support, allowing dual modules to be installed in a single rack to prevent system downtime in the event of a power component failure. Its fanless, natural convection cooling design eliminates a common point of mechanical failure, while integrated protection circuits guard against overvoltage and short-circuits. This level of Expertise and Authority ensures that the DCS remains operational even under fluctuating electrical conditions in harsh plant environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPW482-53 (Model: SPW482-53)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for the FIO (Field I\/O) subsystem, delivering precise voltage regulation for sensitive electronic components.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSPW482-53\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPW Power Supply Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220–240 V AC (Range: 170–264 V AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 V DC (Regulated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥ 85%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural convection (Fanless)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant configuration supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvervoltage, Overload, and Short-circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED status indicators (Ready\/Fault)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Node Rack (FIO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 x 130 x 30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52511039520952,"sku":"SPW482-53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/21._3a8f6d2e-ff3c-406a-aef3-4e41ecc0f815.jpg?v=1769667695"},{"product_id":"s9341fa-yokogawa-centum-vp-xl-esb-bus-termination-unit","title":"S9341FA Yokogawa | CENTUM VP \/ XL ESB Bus Termination Unit","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa S9341FA ESB Bus Connector Unit with Terminator\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9341FA (Model: S9341FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical infrastructure component designed for the Enhanced System Bus (ESB) within Yokogawa’s CENTUM VP and CENTUM XL distributed control systems. Functioning as a specialized connector unit with an integrated terminator, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9341FA (Order Number: S9341FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis installed at the physical end of an ESB bus line. Its primary engineering purpose is to match the characteristic impedance of the transmission line, thereby absorbing electrical signals and preventing signal reflections that could otherwise lead to data corruption or communication timeouts between controllers and I\/O nodes.\u003c\/p\u003e\n\u003cp\u003eIn high-speed industrial networks, maintaining signal integrity is paramount for system Expertise and Trustworthiness (E-E-A-T). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9341FA (Part Number: S9341FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the \"handshake\" between the Field Control Station (FCS) and remote I\/O modules remains deterministic and error-free. Built with industrial-grade components in Singapore, this unit is designed to withstand the thermal and electromagnetic rigors of 24\/7 process environments, supporting hot-swappable maintenance to ensure zero system downtime during network expansions or part replacements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9341FA (Model: S9341FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides reliable termination for ESB networks, featuring a compact form factor for efficient rack integration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS9341FA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB (Enhanced System Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Unit with Integrated Terminator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal reflection suppression and bus termination\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP, CENTUM XL, CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecialized ESB bus interface ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Resistor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in precision impedance matching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Maintains bus continuity during replacement)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (via bus interface)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32.8 × 107.5 × 130 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (with industrial packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingapore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52511040274616,"sku":"S9341FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/4._2558f71c-1185-4a47-8e90-9cd1f696d6d5.jpg?v=1769667977"},{"product_id":"yokogawa-s9342fa-new-2-channel-bus-interface-slave-unit","title":"Yokogawa S9342FA | New 2-Channel Bus Interface Slave Unit","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa S9342FA CENTUM VP ESB Bus Interface Connector Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9342FA (Model: S9342FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 2-channel bus interface connector unit designed for Yokogawa’s Enhanced System Bus (ESB). Within a CENTUM VP or CS 3000 distributed control system (DCS), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9342FA (Order Number: S9342FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical junction point, allowing for the stable branching and termination of communication lines between the Field Control Station (FCS) and remote I\/O nodes. This module is engineered to maintain signal impedance and prevent electrical reflections, ensuring that high-speed data packets are transmitted without corruption across the network.\u003c\/p\u003e\n\u003cp\u003eUnlike basic single-channel terminators, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9342FA (Part Number: S9342FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures dual-channel capabilities, supporting more complex network topologies and redundant bus configurations. It is an essential component for system reliability, particularly in large-scale process plants where long cable runs can introduce signal noise. The module’s Japan-sourced manufacturing ensures the highest standards of Expertise and Trustworthiness (E-E-A-T), providing a ruggedized solution for continuous 24\/7 operation in hazardous or demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9342FA (Model: S9342FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for the FIO (Field I\/O) subsystem, delivering specialized termination and interface logic for distributed control networks.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS9342FA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Channel Bus Interface \/ Connector Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CS 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB (Enhanced System Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBus signal termination and node interfacing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Supplied via backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Supports maintenance without system interruption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Yokogawa System Node Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 x 108 x 130 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (300g)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52511041192120,"sku":"S9342FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/14.1_fbab5a8e-a079-44a1-965e-cc0eaffcd823.jpg?v=1769668284"},{"product_id":"yokogawa-s9343fa-esb-bus-terminator-for-centum-vp-control-systems","title":"Yokogawa S9343FA ESB Bus Terminator for CENTUM VP Control Systems","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa S9343FA\u003c\/strong\u003e Advanced Field Control System component is a dedicated ESB Bus Terminator engineered to maintain stable and reliable communication across Yokogawa’s Enterprise System Bus (ESB). Designed with precision for industrial automation environments, it ensures optimal signal integrity and system protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Termination\u003c\/strong\u003e: Eliminates signal reflection at the end of the ESB bus, ensuring consistent data transmission.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e: Integrated circuitry absorbs transient overvoltage and electrical surges, safeguarding connected devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Endpoint Functionality\u003c\/strong\u003e: Acts as the physical termination point, simplifying ESB bus configuration and reducing installation complexity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Fully compliant with Yokogawa ESB bus architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eESB Bus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eS9343FA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSignal termination, surge and overvoltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eEnd-point installation on ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eStandard ESB bus voltage range (refer to Yokogawa manual for details)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Scope\u003c\/td\u003e\n\u003ctd\u003eYokogawa DCS systems, ESB-based devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuild Quality\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade design for long-term reliability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e: Installed at the bus endpoint to stabilize communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eESB Device Integration\u003c\/strong\u003e: Enhances performance and lifespan of ESB-connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the S9343FA required for every ESB bus installation?\u003c\/strong\u003e  A: Yes, termination is essential to prevent signal reflection and ensure stable communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it be used with non-Yokogawa ESB devices?\u003c\/strong\u003e  A: It is optimized for Yokogawa ESB systems but may function with compatible ESB architectures.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53021892149432,"sku":"S9343FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9341FA2__1.jpg?v=1773735996"},{"product_id":"yokogawa-s9562fa-universal-signal-conditioner-connector-unit","title":"Yokogawa S9562FA Universal Signal Conditioner Connector Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa S9562FA\u003c\/strong\u003e Connector Unit is a precision-engineered signal conditioning device designed to deliver stable and accurate measurement performance in demanding industrial environments. Built with robust construction and optimized for integration into Yokogawa systems, it ensures reliable conversion and conditioning of multiple input signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Measurement Accuracy\u003c\/strong\u003e: ±0.1% of reading, ensuring dependable performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile Input Compatibility\u003c\/strong\u003e: Supports voltage, current, thermocouple, RTD, and strain gauge inputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible Output Options\u003c\/strong\u003e: Provides voltage and current outputs for seamless integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Design\u003c\/strong\u003e: Dimensions of 90 × 60 × 30 mm, weight 0.3 kg, suitable for space-constrained installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable Operation\u003c\/strong\u003e: Functions reliably across a wide temperature range from -10°C to +55°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable Power Supply\u003c\/strong\u003e: Operates on 24 VDC, ensuring consistent performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSignal Conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eS9562FA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew and original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 × 60 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, thermocouple, RTD, strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003eDependent on input type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcess Control Systems\u003c\/strong\u003e: Ensures accurate signal conditioning for sensors and transmitters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLaboratory Measurement\u003c\/strong\u003e: Provides reliable conversion for diverse input signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Automation\u003c\/strong\u003e: Enhances system stability and measurement precision in harsh environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the S9562FA handle multiple input types simultaneously?\u003c\/strong\u003e  A: It supports a wide range of input types, but configuration is required per installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is calibration necessary after installation?\u003c\/strong\u003e  A: Yes, calibration is recommended to achieve optimal accuracy.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53021898244280,"sku":"S9562FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9562FA.jpg?v=1773736290"},{"product_id":"s9564fa-yokogawa-i-o-interface-connector-unit-for-field-control-station","title":"S9564FA | Yokogawa I\/O Interface Connector Unit for Field Control Station","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9564FA (S9564FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance connector interface engineered by Yokogawa for use within the CENTUM series Distributed Control Systems (DCS). This unit facilitates the critical physical link between field-side instrumentation and the system's I\/O modules, ensuring the integrity of signal paths for real-time data acquisition. By utilizing gold-plated contact surfaces, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9564FA (S9564FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeffectively minimizes contact resistance and prevents signal attenuation, which is essential for maintaining the high-fidelity feedback required in process automation.\u003c\/p\u003e\n\u003cp\u003eConstructed from reinforced ABS and designed to meet stringent industrial EMI standards, the module provides a secure and vibration-resistant connection point. Its compact footprint allows for efficient density within the Field Control Station (FCS) cabinet, supporting a wide range of operating temperatures and ensuring consistent uptime in harsh processing environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9564FA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEquipment Category\u003c\/strong\u003e: Industrial Interface Connector Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Plating\u003c\/strong\u003e: Corrosion-resistant gold plating for high-conductivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e: 24 VDC (Standard logic level)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Performance\u003c\/strong\u003e: Functional from -20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Grade\u003c\/strong\u003e: Reinforced ABS (Industrial-grade polymer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Dimensions\u003c\/strong\u003e: 135 mm x 85 mm x 30 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.32 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFixing Method\u003c\/strong\u003e: Supports DIN rail mounting or direct panel integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Compatibility\u003c\/strong\u003e: Fully compatible with CENTUM VP\/CS 3000 FCS and I\/O sub-systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9564FA (S9564FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard requirement for refinery, chemical, and pharmaceutical automation layouts where reliable wiring termination is critical. It is specifically used in the marshaling cabinets of Yokogawa control systems to organize and protect complex multi-core cable runs from field transmitters to the controller rack.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the gold plating benefit the S9564FA interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGold does not oxidize in industrial environments. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9564FA (S9564FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses this plating to ensure that low-voltage analog signals (such as 4-20mA or 1-5V) remain accurate over years of operation without the risk of contact corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be swapped while the FCS is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, as a passive connection interface, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9564FA (S9564FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerally supports modular maintenance. However, engineers should verify that disconnecting specific I\/O loops will not trigger safety interlocks or process alarms within the DCS software environment.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53021902536888,"sku":"S9564FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9564FA.jpg?v=1773736881"},{"product_id":"yokogawa-s9345fa-esb-bus-interface-connector-unit-for-fa-m3-systems","title":"Yokogawa S9345FA ESB Bus Interface Connector Unit for FA-M3 Systems","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA (S9345FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized interface connector unit engineered by Yokogawa to facilitate high-speed data acquisition and communication over the Enterprise System Bus (ESB). This unit serves as a critical structural and electrical backbone for modular control architectures, allowing for the stable integration of various functional modules into the FA-M3 and CENTUM control environments. By providing a streamlined connection point for the ESB bus, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA (S9345FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic performance and minimal signal latency across the system backplane.\u003c\/p\u003e\n\u003cp\u003eDesigned with a focus on industrial scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA (S9345FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports versatile configurations. Its modular footprint is built to Japanese precision standards, ensuring long-term mechanical stability and electrical reliability in high-vibration or electromagnetically noisy industrial settings. This connector unit is essential for engineers seeking to build customized, high-density I\/O arrays that require seamless synchronization with a master Field Control Station.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e: ESB Bus Interface \/ Connector Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: FA-M3 Series and compatible ESB Bus hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Configuration Support\u003c\/strong\u003e: Compatible with base modules in 4, 5, 6, 9, 13, and 16-slot variations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Japan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e: 1.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: Industrial-grade housing optimized for thermal dissipation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Architecture\u003c\/strong\u003e: High-speed Enterprise System Bus (ESB) protocol support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Direct backplane integration for logic-level communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA (S9345FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis predominantly utilized in large-scale Distributed Control Systems (DCS) where remote I\/O expansion is necessary. It is a vital component in power plant automation, water treatment facilities, and pharmaceutical manufacturing lines where the reliability of the ESB bus link directly impacts process safety and efficiency.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the S9345FA improve system scalability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA (S9345FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a standardized interface that allows various I\/O and communication modules to be hot-swapped or expanded without redesigning the primary bus topology. This modular approach significantly reduces downtime during system upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with non-Yokogawa hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9345FA (S9345FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically tuned for the Yokogawa ESB Bus electrical characteristics and the FA-M3 mechanical form factor. Using this unit with third-party bus architectures is not recommended as it may lead to impedance mismatch and signal corruption.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53021933109432,"sku":"S9345FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9562FA_37e72fd3-766e-4b20-99a7-6e7c1aedc320.jpg?v=1773737023"},{"product_id":"s9548fa-yokogawa-2-4v-1900mah-system-backup-battery-pack","title":"S9548FA | Yokogawa 2.4V 1900mAh | System Backup Battery Pack","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9548FA\u003c\/strong\u003e is a specialized industrial battery assembly designed for Yokogawa Distributed Control Systems (DCS), specifically within the CENTUM VP and CS 3000 hardware families. This high-capacity nickel-metal hydride (Ni-MH) or lithium-based rechargeable pack provides the critical DC voltage required to maintain volatile memory (SRAM) and system configuration data during primary power interruptions. By ensuring that the Field Control Station (FCS) retains its internal parameters, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9548FA\u003c\/strong\u003e prevents the loss of revolution counters and user-defined logic during maintenance or unplanned outages.\u003c\/p\u003e\n\u003cp\u003eConstructed for high reliability in industrial control environments, this battery unit features a stable 2.4V output and a 1900mAh capacity, offering extended discharge times compared to standard backup cells. It is typically housed in a protective casing with a keyed connector to ensure secure, vibration-resistant installation within the CPU or power supply module of the Yokogawa rack.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Yokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9548FA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEquipment Type\u003c\/strong\u003e: Backup Battery Pack \/ Memory Support Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: 2.4V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e: 1900 mAh\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCell Chemistry\u003c\/strong\u003e: Industrial Grade rechargeable cells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Yokogawa CENTUM VP, CS 3000, and compatible Field Control Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e: SRAM Data Retention and Real-Time Clock (RTC) support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e: Specialized multi-pin industrial lead\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 0.15 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: Optimized for internal control cabinet environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOperational Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9548FA (S9548FA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for any Yokogawa DCS installation in refineries, chemical plants, and power utility sites. It acts as the final safeguard for process data, ensuring that when power is restored, the system can perform a warm start rather than a cold reboot, significantly reducing recovery time and preventing the need for manual parameter re-entry.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the S9548FA battery pack be replaced?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa generally recommends a preventative maintenance cycle of 2 to 3 years for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9548FA\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e, depending on the ambient temperature of the cabinet. High temperatures can accelerate the chemical depletion of the cells.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the battery fails during a power outage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9548FA\u003c\/strong\u003e is depleted, the Field Control Station will lose its internal memory contents. Upon power restoration, the system will trigger a \"Battery Alarm\" and require a full software download from the Engineering Workstation to restore operations.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53021976199352,"sku":"S9548FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9548FA.jpg?v=1773737380"},{"product_id":"s9260de-01-yokogawa-digital-input-output-module-process-control","title":"S9260DE-01 | Yokogawa | Digital Input\/Output Module | Process Control","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa S9260DE-01\u003c\/strong\u003e Digital Input\/Output Module is a compact, dual-function I\/O unit engineered for advanced process automation. By combining 16 digital input channels and 16 digital output channels in one device, it reduces panel space requirements and simplifies wiring. Built to Yokogawa’s industrial-grade standards, it delivers fast response times, robust isolation, and reliable performance in demanding environments such as oil and gas, chemical processing, and power generation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated I\/O Design\u003c\/strong\u003e: Combines input and output channels in a single module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Speed Response\u003c\/strong\u003e: ≤ 1 ms response time for real-time control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: Optical isolation ensures safety and noise immunity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact and Efficient\u003c\/strong\u003e: Optimized for reduced wiring and simplified installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e: Allows replacement without system shutdown.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCertified Compliance\u003c\/strong\u003e: CE, UL, CSA, and RoHS standards met.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eS9260DE-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input\/Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e~7 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor (open collector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMax. 0.3 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between I\/O and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e≤ 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 V DC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5%–95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBase or node unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e: Provides reliable digital signal handling for automation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Facilities\u003c\/strong\u003e: Suitable for oil, gas, chemical, and power generation plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety-Critical Systems\u003c\/strong\u003e: Optical isolation enhances protection against electrical noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which systems support the S9260DE-01?\u003c\/strong\u003e  A: It integrates with Yokogawa DCS and ER bus-based control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels are included?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: 16 digital inputs and 16 digital outputs in one module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does it provide isolation?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: Yes, optical isolation is built in for safety and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of outputs are supported?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: Transistor (open collector) outputs for dependable actuation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it be replaced during operation?\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e A: Yes, hot-swap functionality allows replacement without shutting down the system.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022053499064,"sku":"S9260DE-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9260DE-01.jpg?v=1773737697"},{"product_id":"s9681db-0-yokogawa-high-performance-4-channel-digital-oscilloscope","title":"S9681DB-0 | Yokogawa High-Performance 4-Channel Digital Oscilloscope","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9681DB-0 (S9681DB-0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced digital oscillography solution engineered for precision signal analysis in high-frequency electronic environments. Designed for research and development, telecommunications, and complex circuit debugging, this 4-channel instrument provides the necessary bandwidth and sampling density to capture transient phenomena with high fidelity. By utilizing a 10-bit vertical resolution architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9681DB-0 (S9681DB-0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers significantly higher signal detail compared to standard 8-bit systems, allowing for the detection of subtle noise and quantization artifacts in high-speed data streams.\u003c\/p\u003e\n\u003cp\u003eThe unit features a robust triggering engine, supporting complex logic, pulse width, and video-specific triggers. Its compact 80mm height profile makes it suitable for rack-mount integration or high-density benchtop use. Built to withstand industrial conditions, it operates reliably across a wide temperature range, ensuring stable measurements even in non-climate-controlled testing facilities.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9681DB-0\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Bandwidth\u003c\/strong\u003e: Up to 2 GHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e: 5 GSa\/s (Giga-samples per second)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 4 Analog Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e: 10 bits (High-definition acquisition)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e: 2 Mbytes per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHorizontal Resolution\u003c\/strong\u003e: 2.5 ns\/div\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime Base Range\u003c\/strong\u003e: 5 ns\/div to 10 s\/div\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger Logic\u003c\/strong\u003e: Edge, Pulse Width, Delay, Video, and Advanced Logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Suite\u003c\/strong\u003e: Voltage, Current, Frequency, Phase, and Peak-to-Peak\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Footprint\u003c\/strong\u003e: 300 mm (L) x 250 mm (W) x 80 mm (H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Weight\u003c\/strong\u003e: 3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e: -20°C to +60°C (0 to 95% RH non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Tolerance\u003c\/strong\u003e: -40°C to +80°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication \u0026amp; Laboratory Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9681DB-0 (S9681DB-0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a primary tool for engineers working on high-speed serial bus analysis, power integrity testing, and RF component characterization. Its 2 GHz bandwidth is particularly effective for troubleshooting LVDS, HDMI, and DDR memory interfaces where fast rise times require high-frequency response to avoid signal rounding and inaccurate jitter measurements.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the S9681DB-0 support active probes for high-impedance testing?\u003c\/strong\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9681DB-0 (S9681DB-0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis compatible with Yokogawa’s range of active and differential probes. Utilizing active probing is recommended for 2 GHz measurements to minimize circuit loading and maintain signal bandwidth at the probe tip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 10-bit resolution benefit my measurements?\u003c\/strong\u003eCompared to 8-bit oscilloscopes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS9681DB-0 (S9681DB-0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides four times the vertical resolution. This allows for more precise measurements of small signal components riding on top of larger DC offsets, which is essential for power rail ripple analysis and sensor signal conditioning.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022064640184,"sku":"S9681DB-0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9260DE-01_d98ae2cb-cd19-4cb9-a565-3c90cc5d7f7a.jpg?v=1773737974"},{"product_id":"s9841da-yokogawa-fa-m3-centum-mixed-analog-digital-i-o-module","title":"S9841DA | Yokogawa | FA-M3 \/ CENTUM | Mixed Analog\/Digital I\/O Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa S9841DA\u003c\/strong\u003e is a hybrid I\/O module designed for integration with FA-M3 controllers and CENTUM distributed control systems. It combines analog input capability with discrete digital outputs in a single compact unit, reducing cabinet space requirements and simplifying system architecture. With sub-millisecond response times and galvanic isolation, it ensures reliable performance in high-speed industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHybrid I\/O Design\u003c\/strong\u003e: 8 configurable analog\/digital input channels plus 8 dedicated digital outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Speed Processing\u003c\/strong\u003e: \u0026lt;1 ms logic response for deterministic control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Protection\u003c\/strong\u003e: 1500 V AC galvanic isolation between field and logic circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact and Efficient\u003c\/strong\u003e: Low power consumption (~2 W) with hot-swappable maintenance capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial-Grade Reliability\u003c\/strong\u003e: Rugged construction for EMI-heavy environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eS9841DA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMixed Analog\/Digital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 configurable analog\/digital sensing channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0–24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eStandard digital output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC dielectric strength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eHot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eFA-M3 controllers, CENTUM DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcess Control Skids\u003c\/strong\u003e: Compact integration of analog sensors and digital actuators.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBoiler and Utility Systems\u003c\/strong\u003e: Monitoring temperature\/pressure while controlling limit switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChemical Dosing Units\u003c\/strong\u003e: Mixed input\/output handling for precise dosing control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWater Treatment Plants\u003c\/strong\u003e: Flexible monitoring and actuation in filtration and pumping systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How do the hybrid inputs function?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: Inputs can be configured for analog or digital sensing depending on wiring and software setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the module suitable for safety instrumented systems (SIS)?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: It is primarily intended for basic process control (BPCS). Suitability for SIS depends on SIL requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the module be replaced online?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: Yes, it supports hot-swapping for maintenance without system shutdown.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022070800568,"sku":"S9841DA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9562FA_ac65edde-b027-4c4b-a998-506ab649aab9.jpg?v=1773738406"},{"product_id":"yokogawa-spw484-53-24v-dc-industrial-power-supply-module","title":"Yokogawa SPW484-53 24V DC Industrial Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa SPW484-53\u003c\/strong\u003e Power Module is a ruggedized DC power supply unit engineered to deliver stable and efficient power to automation systems. Designed for Field Control Units, remote I\/O modules, and other control devices, it ensures reliable operation even in environments with electrical noise and harsh industrial conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulti-Voltage Output\u003c\/strong\u003e: Provides regulated 5 V DC, 3.3 V DC, and 24 V DC outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Efficiency\u003c\/strong\u003e: Operates at up to 85% efficiency, reducing thermal load.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRobust Electrical Protection\u003c\/strong\u003e: Over-voltage detection at ≤32 V, dielectric strength of 500 V AC to ground.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable Performance\u003c\/strong\u003e: Maintains tolerance of +20% \/ -10% at 24 V DC input, supporting up to 11 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e: Built for long-term use in demanding automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSPW484-53\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 3.3 V DC, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e5 V DC: 2 A, 3.3 V DC: 1 A, 24 V DC: 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC ± tolerance (+20% \/ -10%), max 11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e178 mm (W) × 191 mm (D) × 197 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eCable connection to field power supply terminal (EP+, EP-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eTrigger level ≤32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e≥500 V AC to ground for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e≤0.4 pF between output and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField Control Units (FCU)\u003c\/strong\u003e: Provides stable power for distributed control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRemote I\/O Modules\u003c\/strong\u003e: Ensures reliable voltage supply for extended automation networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Control Devices\u003c\/strong\u003e: Suitable for powering controllers and auxiliary modules in harsh conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What devices can the SPW484-53 power?\u003c\/strong\u003e  A: It is designed for Yokogawa Field Control Units, remote I\/O modules, and compatible control devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does it include over-voltage protection?\u003c\/strong\u003e  A: Yes, it detects over-voltage at 32 V or below to protect connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it operate in high-temperature environments?\u003c\/strong\u003e  A: Yes, it functions reliably from -20°C to +60°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How is it connected to the system?\u003c\/strong\u003e  A: Via cable connection to the field power supply terminal (EP+, EP-).\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022072012984,"sku":"SPW484-53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/SPW484-53.jpg?v=1773738633"},{"product_id":"nfpw442-51-yokogawa-fcn-autonomous-controller-power-supply-module","title":"NFPW442-51 | Yokogawa | FCN Autonomous Controller | Power Supply Module","description":"\u003ch2 class=\"\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442-51 (NFPW442-51)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability alternating current power supply unit specifically engineered for the Yokogawa STARDOM FCN (Field Control Node) autonomous controller series.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module converts a high-voltage AC input (220-240 V) into the regulated DC power required to drive the FCN backplane,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCPU,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand associated I\/O modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned as a core component for distributed control and monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442-51 (NFPW442-51)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensures the continuous operation of autonomous logic in mission-critical infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis specific hardware revision is the standard,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enon-explosion-proof variant,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for general industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA key technical advantage of the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442-51 (NFPW442-51)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the inclusion of the ISA Standard G3 option,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding enhanced conformal coating.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis protective layer allows the hardware to resist corrosion in harsh environments where high concentrations of reactive gases or moisture are present,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly extending the service life of the controller hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBrand\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Designation\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSpecific Config Code\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442-51\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHardware Category\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAutonomous Controller Power Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e220 V AC to 240 V AC (Single Phase)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Frequency\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtection Level\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eISA Standard G3 (Environmental Conformal Coating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExplosion Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNone (Standard Type)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Dimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e14.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 cm (H) x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 cm (W) x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 cm (D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Weight\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Series\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSTARDOM FCN \/ FCJ Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation Slot\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDedicated Power Supply Slot in FCN Base Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"\"\u003e\u003cstrong\u003eOperational Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442-51 (NFPW442-51)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis predominantly utilized in STARDOM-based control systems for upstream oil and gas production,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewater treatment facilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand renewable energy monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts compact 50mm width allows for high-density installation in electrical cabinets.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe G3-rated coating makes it particularly effective in wastewater treatment plants and chemical facilities where airborne corrosive agents are a constant concern for sensitive electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the benefit of the Suffix 1 (G3 Option) on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe \"1\" in the suffix of\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eNFPW442-51 (NFPW442-51)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eindicates compliance with ISA S71.\u003c\/span\u003e\u003cspan class=\"\"\u003e04 Severity Level G3.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis means the module is treated with a specialized coating to prevent corrosion of copper and silver components,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich is vital for long-term stability in harsh industrial atmospheres.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan the NFPW442 be used in a redundant power configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the STARDOM FCN chassis typically allows for dual power supply modules. Installing two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW442-51 (NFPW442-51)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits provides the system with hardware redundancy; if one unit loses AC input or fails, the second unit will seamlessly maintain the controller load.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022094622904,"sku":"NFPW442-51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NFPW442-50.jpg?v=1773738879"},{"product_id":"pw301-yokogawa-power-supply-module-power-quality-monitoring","title":"PW301 | Yokogawa | Power Supply Module | Power Quality Monitoring","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa PW301\u003c\/strong\u003e Power Supply Module is part of Yokogawa’s advanced power quality monitoring suite, designed to deliver precise measurement and analysis of electrical parameters. This module supports comprehensive monitoring of voltage, current, and frequency, while offering long-term data logging and transient waveform capture for detailed diagnostics. With integrated communication protocols and real-time display, the PW301 ensures reliable performance in both industrial and commercial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e: Voltage up to 1000 V AC, current up to 600 A AC (via CT).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Monitoring\u003c\/strong\u003e: Operates across 45–65 Hz range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e: Long-term storage capability plus transient waveform capture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e: RS-232, Ethernet, Modbus, and additional protocols for remote monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Display\u003c\/strong\u003e: LCD screen for immediate visualization of power parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Reliability\u003c\/strong\u003e: Operates from -10°C to +50°C, humidity tolerance up to 90% non-condensing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePW301\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module \/ Power Quality Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eUp to 600 A AC (with CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003eLong-term storage, transient waveform capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, Ethernet, Modbus, others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD for real-time monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0–90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Facilities\u003c\/strong\u003e: Continuous monitoring of electrical systems for stability and efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommercial Buildings\u003c\/strong\u003e: Power quality analysis to ensure compliance and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUtility Systems\u003c\/strong\u003e: Long-term logging for diagnostics and predictive maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum voltage the PW301 can measure?\u003c\/strong\u003e  A: It supports measurement up to 1000 V AC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can it log data for extended periods?\u003c\/strong\u003e  A: Yes, it supports long-term data storage for several months.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does it allow remote monitoring?\u003c\/strong\u003e  A: Yes, via Ethernet, RS-232, Modbus, and other supported protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is transient analysis supported?\u003c\/strong\u003e  A: Yes, waveform snapshots can be captured for transient event analysis.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022184898744,"sku":"PW301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PW301.jpg?v=1773739185"},{"product_id":"pw702-yokogawa-ac-input-5-1vdc-29a-controller-power-supply-unit","title":"PW702 | Yokogawa AC Input | 5.1VDC 29A Controller Power Supply Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa PW702\u003c\/strong\u003e Power Supply Unit is a high-capacity PSU designed to deliver stable DC output for demanding industrial automation systems. Built to handle heavy current loads, it ensures reliable operation of controllers, I\/O modules, and other critical devices. Its compact yet durable design makes it suitable for installations requiring consistent performance in space-constrained environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAC Input Range\u003c\/strong\u003e: Operates on 220–240 V AC, 50\/60 Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Output Capacity\u003c\/strong\u003e: Provides +5.1 V DC at up to 29 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Dimensions\u003c\/strong\u003e: Approx. 25.4 × 7.6 × 27.9 cm (10\" × 3\" × 11\").\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLightweight Design\u003c\/strong\u003e: Weighs ~2 kg for easy installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable Performance\u003c\/strong\u003e: Designed for continuous operation in industrial settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePW702\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Unit (PSU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e29 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e26 × 8 × 28 cm (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePower source for controllers, I\/O modules, and automation devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e: Provides stable power for control modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Automation\u003c\/strong\u003e: Supports high-current loads in manufacturing and process plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Installations\u003c\/strong\u003e: Suitable for cabinets with limited space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum output current of the PW702?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: It delivers up to 29 A at +5.1 V DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What input voltage range does it support?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: 220–240 V AC at 50\/60 Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How heavy is the unit?\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e A: Approximately 2 kg, making it relatively lightweight for its capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What applications is it best suited for?\u003c\/strong\u003e  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: Powering controllers, I\/O modules, and automation hardware requiring stable DC supply.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022232936632,"sku":"PW702","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PW702.jpg?v=1773739373"},{"product_id":"pw442-50-yokogawa-100-240vac-input-24vdc-5a-power-supply-module","title":"PW442-50 | Yokogawa 100-240VAC Input | 24VDC 5A Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa PW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module is engineered to deliver regulated and stable DC power for mission-critical automation platforms. Designed for long-term reliability, it ensures consistent voltage regulation under varying load conditions, making it suitable for high-availability architectures such as CENTUM and ProSafe systems. With integrated protection features and robust isolation, the PW442-50 provides dependable performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Input Range\u003c\/strong\u003e: Auto-selects between 100–120 VAC or 200–240 VAC, 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated Output\u003c\/strong\u003e: Supplies 24 V DC at up to 5 A, with 120 W typical capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Efficiency\u003c\/strong\u003e: ≥ 80% conversion efficiency with ±1% load regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Ripple\u003c\/strong\u003e: ≤ 50 mVp-p for clean power delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e: Overload, overvoltage, short-circuit, and thermal safeguards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Strength\u003c\/strong\u003e: ≥ 1500 VAC between input and output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e: Natural convection, no external cooling required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e: MTBF \u0026gt; 150,000 hours under typical operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePW442-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100–120 VAC \/ 200–240 VAC (auto-select)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMax. 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e120 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥ 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \u0026amp; Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 50 mVp-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOverload, overvoltage, short-circuit, thermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20–70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Strength\u003c\/td\u003e\n\u003ctd\u003e≥ 1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eBase-mounted in system rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM, ProSafe, subsystem racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 150,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCENTUM Systems\u003c\/strong\u003e: Provides stable power for distributed control system racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProSafe Platforms\u003c\/strong\u003e: Ensures reliable supply for safety instrumented systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubsystem Racks\u003c\/strong\u003e: Supports redundant configurations for uninterrupted operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which systems are compatible with the PW442-50?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It integrates with Yokogawa CENTUM, ProSafe, and subsystem racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support redundancy?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Yes, redundant operation is supported for enhanced reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protections are included?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Overload, overvoltage, short-circuit, and thermal protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long is the expected service life?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: MTBF exceeds 150,000 hours under typical conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is external cooling required?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: No, it uses natural convection cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be hot-swapped?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Hot-swapping depends on rack configuration; many Yokogawa racks support controlled replacement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022278713528,"sku":"PW442-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NFPW442-50_fdc79e99-b50e-4e28-b0bc-c0c177c06ea4.jpg?v=1773739559"},{"product_id":"yokogawa-pw481-10-power-supply-module-centum-cs-vp-systems","title":"Yokogawa PW481-10 | Power Supply Module Centum CS\/VP Systems","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa PW481-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module is a compact and reliable PSU designed to provide regulated AC-to-DC conversion for Yokogawa Centum CS and Centum VP systems. Built with industrial-grade durability, it ensures consistent performance under varying load conditions and supports optional explosion protection for installations in hazardous environments.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable AC Input\u003c\/strong\u003e: Operates on 100–120 V AC ±10%, 50\/60 Hz ±3 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Power Delivery\u003c\/strong\u003e: Maximum consumption of 200 VA with exclusive connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and Lightweight\u003c\/strong\u003e: Dimensions ~26 × 8 × 28 cm, weight ~1 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Designed for Centum CS and Centum VP platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Safety Feature\u003c\/strong\u003e: Explosion protection available for specialized applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability\u003c\/strong\u003e: Engineered for continuous operation in demanding industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePW481-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003ctd\u003e200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eExclusive input\/output connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e26 × 8 × 28 cm (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCentum CS, Centum VP systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003eExplosion protection available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Systems\u003c\/strong\u003e: Provides stable power for Centum CS\/VP controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation\u003c\/strong\u003e: Suitable for continuous operation in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Areas\u003c\/strong\u003e: Optional explosion protection for compliance with safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the PW481-10 support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It operates on 100–120 V AC ±10%, 50\/60 Hz ±3 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is explosion protection available?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Yes, an optional version includes explosion protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What systems are supported?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It is compatible with Yokogawa Centum CS and Centum VP systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How heavy is the module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Approximately 1 kg, making it lightweight and easy to install.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022318690488,"sku":"PW481-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PW481-50.jpg?v=1773739751"},{"product_id":"pw481-50-yokogawa-centum-dcs-ac-power-supply-module","title":"PW481-50 | Yokogawa CENTUM DCS | AC Power Supply Module","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50 (PW481-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance AC power supply unit engineered for Yokogawa’s Distributed Control Systems (DCS). This module serves as a direct, upgraded replacement for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-10\u003c\/strong\u003e, offering enhanced electrical stability and improved thermal efficiency for Field Control Units (FCU). It is designed to convert wide-range AC utility power into the stabilized DC voltages necessary to drive the system backplane, processor cards, and I\/O interface modules.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-availability industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50 (PW481-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a robust internal filtration system that shields sensitive control logic from line noise and voltage transients. Its heavy-duty chassis is optimized for the physical rigors of control cabinet mounting, ensuring consistent power delivery in 24\/7 process industries such as petrochemical refining and power generation.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Yokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy Compatibility\u003c\/strong\u003e: Direct replacement for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-10\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: Auto-ranging 100-120 VAC \/ 220-240 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Rails\u003c\/strong\u003e: Regulated +12 VDC and +24 VDC (System dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Footprint\u003c\/strong\u003e: 11 cm (W) x 28 cm (D) x 26 cm (H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 3.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e: Natural convection \/ Internal heat dissipation design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Dedicated PSU slot within Yokogawa Field Control Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Integration \u0026amp; Upgrade Path\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50 (PW481-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the preferred choice for facilities undergoing system lifecycle management. By replacing aging\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50 (PW481-50)\u003c\/strong\u003e, engineers can improve the overall MTBF (Mean Time Between Failures) of their control racks. The module is fully compatible with existing rack backplanes, requiring no additional wiring modifications for most standard CENTUM configurations.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PW481-50 be used in a redundant power configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50 (PW481-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for use in dual-redundant setups. In a standard Yokogawa FCU, two modules work in parallel to share the load; if one fails, the remaining unit immediately assumes the full load without interrupting the process control intelligence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary differences between the PW481-50 and the older PW481-10?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the form factor remains identical for compatibility, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481-50 (PW481-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes modernized internal components that offer better resistance to heat and improved power factor correction, making it a more reliable and energy-efficient solution for modern DCS cabinets.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022320132280,"sku":"PW481-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PW481-50_e8c08c71-f525-4736-a582-4bddfb4ac636.jpg?v=1773742830"},{"product_id":"pw481-50-yokogawa-centum-dcs-ac-power-supply-module-副本","title":"PW484-11 | Yokogawa CENTUM VP 100-120V AC Power Supply Module","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized AC-to-DC power conversion module engineered for Yokogawa’s CENTUM VP Distributed Control System (DCS). This hardware provides the high-stability logic power required by Field Control Units (FCU), FIO node units, and Optical ESB Bus Repeater modules. Designed for high-availability environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the control backplane receives a regulated voltage supply, shielding sensitive internal processors from input line fluctuations.\u003c\/p\u003e\n\u003cp\u003eBuilt for mission-critical infrastructure, the module occupies the P1 and P2 slots of the node unit, allowing for a dual-redundant power configuration. This architecture enables seamless failover; should one module lose input power, the redundant partner immediately assumes the full electrical load without interrupting the process control intelligence. Its compact Japanese engineering facilitates high-density mounting in industrial control cabinets, providing long-term reliability for continuous 24\/7 operations.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Yokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Category\u003c\/strong\u003e: Industrial Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Requirement\u003c\/strong\u003e: 100–120 V AC (Tolerance: ±10%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e: 50\/60 Hz (Tolerance: ±3 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e: 200–230 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Positions\u003c\/strong\u003e: Standard P1–P2 redundant slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterconnect\u003c\/strong\u003e: Proprietary high-security exclusive connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Mass\u003c\/strong\u003e: Approximately 1.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 49.7 mm (W) × 199.5 mm (H) × 149 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Environment Compatibility\u003c\/strong\u003e: CENTUM VP DCS, FIO Node Units, Optical ESB Repeater Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufactured In\u003c\/strong\u003e: Japan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Profile\u003c\/strong\u003e: Continuous duty in heavy industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOperational Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-11 (PW484-11)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis predominantly utilized in the primary control racks of oil refineries, chemical processing plants, and power utilities. It is the preferred power solution for FIO (Field Input\/Output) nodes where reliable communication with the central controller is paramount. Its vibration-resistant and thermally optimized design makes it suitable for onsite control rooms located near heavy machinery.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the PW484-11 with different PW48x models in a redundant setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor optimal electrical balancing and synchronization of the redundancy logic, it is highly recommended to use two identical\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-11 \u003c\/strong\u003emodules. Mixing different revisions or voltage types can lead to premature wear or system alarms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary symptoms of a failing power module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsually, the system will trigger a \"PSU Alarm\" on the HIS (Human Interface Station). Physically, the status LED on the front of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewill change from green to red or turn off entirely, indicating an input failure or internal fault.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022380130488,"sku":"PW484-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9260DE-01_5e6bc306-9489-4ceb-a11b-de30b7152898.jpg?v=1773743391"},{"product_id":"nfpw444-50-yokogawa-power-supply-module-24-vdc-input","title":"NFPW444-50 | Yokogawa | Power Supply Module | 24 VDC Input","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFPW444-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module is a compact DC input unit designed to deliver regulated output for Yokogawa control systems. Built for reliability, it ensures stable +5.1 V DC output with high current capacity, making it suitable for demanding automation environments. With multiple model variations, including standard and basic types, as well as a one-phase version, the NFPW444-50 provides flexibility for different installation requirements.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Input Operation\u003c\/strong\u003e: Rated input voltage of 24 V DC, with tolerance range from 21.6 to 31.2 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated Output\u003c\/strong\u003e: Provides +5.1 V DC with up to 7.8 A output current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Size\u003c\/strong\u003e: Dimensions ~14.65 × 4.97 × 13 cm, weight ~0.6 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Variants\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1S = One-phase version for single-phase load or neutral-phase connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 = Standard type without explosion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 = Basic type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Reliability\u003c\/strong\u003e: Designed for continuous operation in Yokogawa system racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e21.6–31.2 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0–7.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e~14.65 × 4.97 × 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Variants\u003c\/td\u003e\n\u003ctd\u003e1S (1-phase), 5 (standard), 0 (basic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Control Systems (DCS)\u003c\/strong\u003e: Provides stable DC supply for Yokogawa racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation\u003c\/strong\u003e: Suitable for continuous operation in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Configurations\u003c\/strong\u003e: Flexible installation options with multiple model variants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the NFPW444-50 support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It operates on 24 V DC nominal, with a range of 21.6–31.2 V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the rated output current?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Up to 7.8 A at +5.1 V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are different versions available?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Yes, including 1S (one-phase), 5 (standard type), and 0 (basic type).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How heavy is the unit?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Approximately 0.6 kg.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022381539512,"sku":"NFPW444","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/NFPW442-50_6f6c5c0d-66ee-45a1-89bb-d318ff4778d5.jpg?v=1773743672"},{"product_id":"yokogawa-spw481-13-power-supply-module-fault-supervised-psu","title":"Yokogawa SPW481-13 Power Supply Module | Fault-Supervised PSU","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SPW481-13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module is a specialized PSU designed to deliver stable DC output while providing advanced fault supervision and relay functionality. Built for reliability in industrial automation environments, it ensures consistent power delivery and clear system status indication. With programmable relay outputs and compliance to ISA G3 standards, the SPW481-13 is engineered for applications requiring both dependable power and integrated monitoring.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Input Operation\u003c\/strong\u003e: Supports 100–120 V AC, 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e: Provides regulated DC output with up to 2.5 A current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Supervision\u003c\/strong\u003e: Includes fused and fault-supervised outputs for external device protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e: Three programmable, fused, potential-free relay outputs for versatile control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire\/Fault Indication\u003c\/strong\u003e: One programmable current-sinking output for FIRE and one for FAULT status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Reliability\u003c\/strong\u003e: Operates from -20°C to +70°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: Meets ISA Standard G3 for industrial durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design\u003c\/strong\u003e: Weight ~1.5 kg, suitable for control cabinet installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSPW481-13\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3 programmable, fused, potential-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire\/Fault Outputs\u003c\/td\u003e\n\u003ctd\u003e1 programmable current-sinking FIRE, 1 FAULT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Control Systems\u003c\/strong\u003e: Provides stable power with integrated fault monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety-Critical Installations\u003c\/strong\u003e: Fire and fault outputs ensure clear system status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomation Cabinets\u003c\/strong\u003e: Compact design suitable for space-constrained environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the SPW481-13 support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It operates on 100–120 V AC, 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many relay outputs are available?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Three programmable, fused, potential-free relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it provide fire\/fault indication?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Yes, it includes one FIRE and one FAULT programmable current-sinking output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What standards does it comply with?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It meets ISA Standard G3 for industrial reliability.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022384128184,"sku":"SPW481-13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/SPW481-13.jpg?v=1773743861"},{"product_id":"yokogawa-pw701-120vac-distributed-control-system-power-supply-module","title":"Yokogawa PW701 | 120VAC | Distributed Control System Power Supply Module","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701 (PW701)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity power supply module engineered for Yokogawa’s legacy and specialized control rack architectures. This unit is designed to provide the foundational logic power required for high-density PLC and DCS configurations, converting a 120VAC primary input into the stabilized DC rails necessary for backplane communication. Built for long-term industrial reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701 (PW701)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that processor cards and I\/O modules receive consistent, ripple-free voltage, which is essential for maintaining deterministic control in process automation.\u003c\/p\u003e\n\u003cp\u003eThe module features a ruggedized chassis designed for thermal efficiency and resistance to industrial electromagnetic interference (EMI). Its robust internal circuitry is protected against over-voltage and over-current conditions, acting as a critical safeguard for the sensitive electronics integrated within the control rack. Whether utilized as a primary power source or as part of a maintenance spare strategy, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701 (PW701)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a vital component for ensuring system uptime in heavy industrial environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEquipment Category\u003c\/strong\u003e: System Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 120V AC (Nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Function\u003c\/strong\u003e: Backplane and Logic Power Distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e: 2.02 kg (Approx. 4.45 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Form Factor\u003c\/strong\u003e: Rack-mountable PLC\/DCS Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Dedicated PSU slot within compatible Yokogawa racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Features\u003c\/strong\u003e: Integrated fuse protection and voltage regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e: Natural convection within the rack chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701 (PW701)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis predominantly deployed in established manufacturing facilities, power plants, and chemical processing sites where reliable logic power is mandatory. It is specifically used to support the central processing units and high-speed communication modules that manage critical process loops. Its heavy-duty construction makes it particularly suitable for environments where electrical stability is challenged by large inductive motor loads.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the PW701 compatible with 240VAC input systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701 (PW701)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically rated for 120VAC input. For 240V environments, a different power module variant (such as the PW702) must be utilized to prevent hardware damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended replacement interval for this power module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW701 (PW701)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for continuous duty, it is recommended to inspect the unit every 3-5 years for capacitor aging or thermal stress, especially if operated in high-temperature control cabinets.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022389993656,"sku":"PW701","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/PW701.jpg?v=1773744026"},{"product_id":"yokogawa-pw484-10-power-supply-module-24-vdc-input","title":"Yokogawa PW484-10 Power Supply Module | 24 VDC Input","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa PW484-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module is a compact and efficient DC input unit designed to provide regulated output for Yokogawa automation systems. As part of the PW48x series, it ensures stable and reliable power delivery to CENTUM VP Distributed Control Systems, Field Control Units (FCU), and FIO Node Units. With its lightweight design and robust construction, the PW484-10 is suitable for continuous operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Input Operation\u003c\/strong\u003e: Rated input voltage of 24 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Output Supply\u003c\/strong\u003e: Provides regulated DC output for Yokogawa system racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Dimensions\u003c\/strong\u003e: Space-efficient design for cabinet integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Reliability\u003c\/strong\u003e: Built for long-term operation in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Designed for CENTUM VP, FCU, and FIO Node Units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePW484-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eRegulated DC (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PW48x module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, FCU, FIO Node Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCENTUM VP Systems\u003c\/strong\u003e: Provides stable DC supply for distributed control system racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Control Units\u003c\/strong\u003e: Ensures reliable operation of FCU modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFIO Node Units\u003c\/strong\u003e: Supplies regulated DC power for flexible I\/O configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the PW484-10 support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It operates on 24 V DC input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which systems are compatible with the PW484-10?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: It integrates with Yokogawa CENTUM VP, FCU, and FIO Node Units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How heavy is the module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Approximately 1.0 kg, making it lightweight and easy to install.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it part of a series?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003cbr\u003eA: Yes, it belongs to the PW48x series of power supply modules.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53022390452408,"sku":"PW484-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/S9260DE-01_107a0174-a09d-49f3-8a81-54b5c25b19f1.jpg?v=1773744190"},{"product_id":"aai543-s50-yokogawa-centum-vp-16-channel-analog-output-module","title":"AAI543-S50 | Yokogawa CENTUM VP 16-Channel Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI543-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density analog output interface within the CENTUM VP distributed control system. This module commands field actuators, valves, and positioners by delivering 16 isolated 4 to 20 mA signals. It integrates full HART communication capabilities, allowing the control system to access secondary variables and diagnostic data from \"smart\" field devices without additional hardware. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring maximum loop integrity and synchronization for critical process control applications.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe AAI543-S50 utilizes specific suffix codes to define its operational and safety characteristics:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAAI543\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 16-Channel Analog Output Module (4-20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard type hardware architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy support with standard switch-over; no explosion protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic hardware type configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AAI543-S50 offers deterministic signal delivery and high-voltage isolation for industrial output loops.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16, fully isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAvailable (Integrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Load Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 750\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Update Period:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±48\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003eA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC (Output to system) for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit-Open Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriggers at less than 0.65 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±16\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003eA \/ 10 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e230 mA (5 V DC); 540 mA (24 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AAI543-S50 addresses specific process stability and maintenance challenges through advanced signal conditioning:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstantaneous Response for Fast Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 10 ms data update period eliminates control lag. This speed enables the module to manage high-speed valves and surge protection systems where delay directly impacts plant safety and product quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Data Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module transparently passes HART signals between the field device and the DCS. This allows maintenance teams to perform remote calibration and monitor device health parameters (\u003cspan class=\"math-inline\"\u003e$PV, SV, TV, QV$\u003c\/span\u003e) directly from the control room, significantly reducing the need for field inspections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Load Driving Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith support for load resistances up to 750\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e, this module drives signals over long cable runs without loss of accuracy. This proves critical in large-scale refineries and offshore platforms where actuators reside hundreds of meters from the I\/O nest.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Configuration Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuffix \"5\" indicates the module supports dual-redundant deployment. In this setup, the system maintains output continuity during a module switch-over, preventing process upsets and ensuring 24\/7 operational availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the AAI543-S50 handle a broken field wire?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module incorporates an automatic circuit-open detection function. If the loop current drops below 0.65 mA, the module flags a diagnostic error to the system, allowing operators to identify cable damage or actuator failure immediately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with non-HART devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The AAI543-S50 functions as a standard 4 to 20 mA analog output module for conventional actuators while remaining ready to communicate with HART-enabled devices whenever you upgrade your field instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal types are compatible with the AAI543-S50?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports multiple connection methods, including pressure clamp terminals for direct wiring, MIL connector cables for high-density integration, and dedicated KS1 cables for Yokogawa-specific termination boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1500V AC withstanding voltage protect the DCS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The 1500V isolation barrier prevents high-voltage transients on the field side from migrating to the sensitive system backplane, effectively shielding the central processor from catastrophic electrical failures.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53296823632056,"sku":"AAI543-S50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AAI543-S00.jpg?v=1776151486"}],"url":"https:\/\/www.globalpetroparts.com\/collections\/yokogawa-power-supply-battery.oembed","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}