{"product_id":"10208-2-1-honeywell-relay-output-module","title":"10208\/2\/1 | Honeywell Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10208\/2\/1\u003c\/strong\u003e is a \u003cstrong\u003eRelay Output Module\u003c\/strong\u003e for the Honeywell FSC (Fail Safe Control) system. It provides \u003cstrong\u003e10 channels\u003c\/strong\u003e of relay contact outputs, supporting both resistive and inductive loads up to \u003cstrong\u003e70W\u003c\/strong\u003e with a maximum voltage of \u003cstrong\u003e36 Vdc\u003c\/strong\u003e, ideal for applications requiring galvanically isolated switching.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 10208\/2\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Honeywell FSC (Fail Safe Control)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e \u003cstrong\u003e10 channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Relay contacts (passive)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e \u003cstrong\u003e36 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switched Power:\u003c\/strong\u003e \u003cstrong\u003e70W\u003c\/strong\u003e (resistive or inductive loads)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e \u003cstrong\u003e2 A\u003c\/strong\u003e per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Switched Power:\u003c\/strong\u003e 100 W \/ 1000 VA (per channel ratings)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Material:\u003c\/strong\u003e Gold-flush silver-cadmium oxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\n  \u003cul\u003e\n    \u003cli\u003e5 VDC: 25 mA\u003c\/li\u003e\n    \u003cli\u003e24 VDC: 120 mA\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e \u003cstrong\u003e4 TE, 3 HE\u003c\/strong\u003e (= 4 HP, 3U)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 259g (0.57 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TÜV, UL\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10 passive relay contact outputs for versatile load switching\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between channels and system logic\u003c\/li\u003e\n\u003cli\u003eSupports both resistive and inductive loads\u003c\/li\u003e\n\u003cli\u003eHigh-quality contact material for extended electrical life\u003c\/li\u003e\n\u003cli\u003eVoltage-free contacts allow flexible external circuit design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay-based safety interlock systems\u003c\/li\u003e\n\u003cli\u003eAlarm annunciation and signaling\u003c\/li\u003e\n\u003cli\u003eMotor contactor control\u003c\/li\u003e\n\u003cli\u003eValve solenoid control via relay isolation\u003c\/li\u003e\n\u003cli\u003eLegacy device integration requiring contact outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the relay contacts voltage-free?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the 10208\/2\/1 provides \u003cstrong\u003epassive relay contacts\u003c\/strong\u003e (voltage-free), allowing connection to external circuits at different voltage levels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum load per channel?\u003c\/strong\u003e\u003cbr\u003e\nA: The maximum switched power is \u003cstrong\u003e70W\u003c\/strong\u003e with a maximum voltage of \u003cstrong\u003e36 Vdc\u003c\/strong\u003e and maximum current of \u003cstrong\u003e2A\u003c\/strong\u003e per channel.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the FSC rack before installation.\u003c\/li\u003e\n\u003cli\u003eInsert the module into the designated I\/O slot (4 TE, 3 HE).\u003c\/li\u003e\n\u003cli\u003eConnect relay contacts to field circuits observing load ratings.\u003c\/li\u003e\n\u003cli\u003eInstall suppression devices for inductive loads if required.\u003c\/li\u003e\n\u003cli\u003eVerify contact operation via FSC diagnostic tools.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor 12-channel relay outputs, consider \u003cstrong\u003e10208\/1\/1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFor solid-state 24Vdc outputs, consider \u003cstrong\u003e10201\/2\/1\u003c\/strong\u003e or \u003cstrong\u003e10206\/2\/1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEnsure load characteristics (resistive\/inductive) are within rated specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53827429105848,"sku":"10208\/2\/1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1020821_2_r180.png?v=1785223030","url":"https:\/\/www.globalpetroparts.com\/products\/10208-2-1-honeywell-relay-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}