{"product_id":"10213-2-3-honeywell-fail-safe-digital-output-module","title":"10213\/2\/3 | Honeywell Fail-Safe Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10213\/2\/3\u003c\/strong\u003e is a \u003cstrong\u003eFail-Safe Digital Output Module\u003c\/strong\u003e for the Honeywell FSC (Fail Safe Control) system. It provides \u003cstrong\u003e4 channels\u003c\/strong\u003e of \u003cstrong\u003e48 V DC\u003c\/strong\u003e fail-safe outputs at \u003cstrong\u003e0.75 A\u003c\/strong\u003e per channel, designed for safety-critical applications requiring higher voltage operation.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 10213\/2\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fail-Safe Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Honeywell FSC (Fail Safe Control)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e \u003cstrong\u003e4 channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e \u003cstrong\u003e48 V DC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e \u003cstrong\u003e0.75 A\u003c\/strong\u003e per channel (750 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe Design:\u003c\/strong\u003e Component failure results in de-energized output (safe state)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Functions:\u003c\/strong\u003e Tests ability to output logic '0' and '1' within process safety time\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e Standard FSC module format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TÜV, UL\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFail-safe design for safety-critical 48Vdc applications\u003c\/li\u003e\n\u003cli\u003eHigher voltage operation for specialized industrial devices\u003c\/li\u003e\n\u003cli\u003eSelf-test verification ensures output integrity\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation protects system backplane\u003c\/li\u003e\n\u003cli\u003eCompact form factor for FSC rack integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e48Vdc safety interlock systems\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown valve control\u003c\/li\u003e\n\u003cli\u003eHigh-voltage relay driver applications\u003c\/li\u003e\n\u003cli\u003eProcess safeguarding in petrochemical industries\u003c\/li\u003e\n\u003cli\u003ePower generation safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage options are available in the 10213 series?\u003c\/strong\u003e\u003cbr\u003e\nA: The 10213 series includes \u003cstrong\u003e10213\/2\/1 (110Vdc, 0.32A)\u003c\/strong\u003e, \u003cstrong\u003e10213\/2\/2 (60Vdc, 0.67A)\u003c\/strong\u003e, and \u003cstrong\u003e10213\/2\/3 (48Vdc, 0.75A)\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with 24Vdc systems?\u003c\/strong\u003e\u003cbr\u003e\nA: No, the 10213\/2\/3 is specifically designed for \u003cstrong\u003e48 Vdc\u003c\/strong\u003e operation. For 24Vdc applications, use 10201\/2\/1 or 10215\/2\/1.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the FSC rack before installation.\u003c\/li\u003e\n\u003cli\u003eVerify 48 Vdc power supply availability.\u003c\/li\u003e\n\u003cli\u003eInsert the module into the designated I\/O slot.\u003c\/li\u003e\n\u003cli\u003eConnect 48 Vdc field power to the module terminals.\u003c\/li\u003e\n\u003cli\u003eWire field devices observing proper polarity.\u003c\/li\u003e\n\u003cli\u003ePerform functional testing and self-test verification.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor 110Vdc applications, use \u003cstrong\u003e10213\/2\/1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFor 60Vdc applications, use \u003cstrong\u003e10213\/2\/2\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFor loop-monitored 48Vdc outputs, consider \u003cstrong\u003e10216\/2\/3\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53827428188344,"sku":"10213\/2\/3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1020121_2_ca07c4b0-cae1-4906-84c8-a4dd19c1bd93.png?v=1785223045","url":"https:\/\/www.globalpetroparts.com\/products\/10213-2-3-honeywell-fail-safe-digital-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}