{"product_id":"136188-01-bently-nevada-3500-series-ethernet-communication-gateway-module","title":"136188-01 | Bently Nevada | 3500 Series Ethernet Communication Gateway Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 136188-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-speed communication bridge within the 3500 Series Machinery Protection System. This module facilitates the transfer of critical machine health data from the internal backplane to external Ethernet networks. It ensures that host computers and Distributed Control Systems (DCS) receive real-time status updates and static data without interfering with primary protection functions. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to guarantee the highest cybersecurity and data throughput standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136188-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTCP\/IP Ethernet \/ Modbus over Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Form Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack-Mountable I\/O \/ Communication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Throughput\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed static data polling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Data Streaming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 136188-01 bypasses legacy serial bottlenecks. It streams vibration, position, and temperature data directly to your plant network via robust Ethernet protocols, supporting faster decision-making for plant operators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Hardened Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-voltage industrial environments generate significant electrical noise. This module incorporates advanced shielding to maintain signal integrity, ensuring that data transmission remains stable even when located near large motors or variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless DCS Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports industry-standard Modbus protocols. This allows the 3500 system to talk directly to your PLC or DCS without requiring expensive third-party protocol converters, simplifying the overall system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Cabinet Solution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 136188-01 design optimizes rack real estate. It installs into the standard 3500 chassis without requiring specialized power taps or external cooling hardware, making it ideal for retrofitting existing cabinets with limited space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 136188-01 require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module draws its operating power directly from the 3500 rack backplane. This reduces wiring complexity and ensures that the communication gateway initializes simultaneously with the rest of the machinery protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the IP settings on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou perform all network configurations using the 3500 Rack Configuration Software. Connecting a configuration PC to the rack allows you to set static IPs or define the Modbus registers for your specific monitoring requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a direct replacement for legacy serial interface modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 136188-01 provides modern Ethernet capabilities that significantly outperform older RS232\/RS485 serial interfaces. It offers higher bandwidth and easier connectivity for modern System 1™ software environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify that I am receiving a 100% Brand New unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach 136188-01 ships in original factory-sealed anti-static packaging. The unit includes a verified serial number and date code from the Bently Nevada USA facility, ensuring it has never seen previous field service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53462540058808,"sku":"136188-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/136188-01.jpg?v=1778731100","url":"https:\/\/www.globalpetroparts.com\/products\/136188-01-bently-nevada-3500-series-ethernet-communication-gateway-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}