{"product_id":"140aci03000-schneider-modicon-quantum-analog-input-module","title":"140ACI03000 Schneider Modicon Quantum Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140ACI03000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC platform, designed for accurate industrial signal acquisition. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 differential input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1–5 V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals, delivering stable and repeatable measurements. An integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-pole low-pass filter (−3 dB @ 15 Hz)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuppresses high-frequency noise, ensuring reliable process data in electrically noisy environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140ACI03000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e4–20 mA \/ 1–5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 20 MΩ (voltage) \/ 250 Ω (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e5 ms update rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \/ Linearity\u003c\/td\u003e\n\u003ctd\u003e±0.04% linearity error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Filtering\u003c\/td\u003e\n\u003ctd\u003eSingle-pole low-pass (−3 dB @ 15 Hz ±20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32°F to 140°F (0°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eAdvanced Diagnostics\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140ACI03000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates proactive fault detection to improve system reliability:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroken wire detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor 4–20 mA loops when current falls below threshold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUndervoltage monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor 1–5 V inputs indicating signal degradation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese diagnostics reduce troubleshooting time and help prevent unplanned downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eCommonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess control and monitoring systems\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePressure, flow, and level measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and batch processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation auxiliaries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide loop power for 4–20 mA signals?\u003c\/strong\u003e\u003cbr\u003eNo. External loop power or a field power supply is required to drive current through the internal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e250 Ω precision resistors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan voltage and current inputs be mixed on the same module?\u003c\/strong\u003e\u003cbr\u003eYes, but each channel (or channel group) must be correctly wired and configured in software to match the assigned signal type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal block is recommended?\u003c\/strong\u003e\u003cbr\u003eThe standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum 40-pin terminal block (140XTS00200)\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52505487835320,"sku":"140ACI03000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140ACI030001.jpg?v=1769496347","url":"https:\/\/www.globalpetroparts.com\/products\/140aci03000-schneider-modicon-quantum-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}