{"product_id":"140noc77100-schneider-modicon-140-ethernet-ip-network-module","title":"140NOC77100 | Schneider Modicon | 140 Ethernet\/IP Network Module","description":"\u003ch3\u003eSchneider Electric 140NOC77100 Modicon Quantum Ethernet\/IP Network Module — RJ45, 10\/100 Mbit\/s, 128 Connections\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e140NOC77100\u003c\/strong\u003e is an \u003cstrong\u003eEthernet\/IP network module\u003c\/strong\u003e for Schneider Electric's \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e automation platform. It provides \u003cstrong\u003eRJ45-based 10\/100 Mbit\/s Ethernet connectivity\u003c\/strong\u003e with support for up to \u003cstrong\u003e128 simultaneous connections\u003c\/strong\u003e, enabling seamless integration of Quantum PLCs into Ethernet\/IP industrial networks. The module supports \u003cstrong\u003eSNMP network management\u003c\/strong\u003e, \u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e communication, and \u003cstrong\u003eUnity Pro \/ Concept\u003c\/strong\u003e configuration for distributed I\/O and peer-to-peer communication.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Quantum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Ethernet\/IP Network Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Port Protocol:\u003c\/strong\u003e Ethernet\/IP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Rate:\u003c\/strong\u003e 10\/100 Mbit\/s (auto-negotiation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Type:\u003c\/strong\u003e RJ45 (10BASE-T\/100BASE-TX)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Number of Connections:\u003c\/strong\u003e 128\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Services:\u003c\/strong\u003e SNMP (Simple Network Management Protocol), Modbus TCP\/IP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Management:\u003c\/strong\u003e SNMP v1\/v2c support for network monitoring and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Quantum backplane slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Software:\u003c\/strong\u003e Unity Pro, Concept\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Discontinued — replaced by BMENOC0301 (M580 Ethernet communication module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eArchitecture \u0026amp; Functionality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet\/IP Protocol:\u003c\/strong\u003e Full Ethernet\/IP scanner\/adapter support for integration with Rockwell Automation and other Ethernet\/IP-compatible devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP\/IP:\u003c\/strong\u003e Native Modbus TCP\/IP server\/client functionality for communication with HMI, SCADA, and other Modbus TCP devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSNMP Support:\u003c\/strong\u003e Network management via SNMP v1\/v2c for remote monitoring, fault detection, and performance optimization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e128 Simultaneous Connections:\u003c\/strong\u003e High connection capacity supports large-scale distributed systems with multiple clients and servers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-Negotiation:\u003c\/strong\u003e 10\/100 Mbit\/s auto-negotiation ensures compatibility with existing network infrastructure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRJ45 Connector:\u003c\/strong\u003e Standard RJ45 port for easy connection to Ethernet switches and industrial networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Server:\u003c\/strong\u003e Embedded Web server for module diagnostics and configuration monitoring (via standard Web browser)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the 140NOC77100 into a \u003cstrong\u003estandard I\/O slot\u003c\/strong\u003e on the Quantum backplane.\u003c\/li\u003e\n\u003cli\u003eConnect an \u003cstrong\u003eEthernet cable (Cat 5e\/6)\u003c\/strong\u003e from the RJ45 port to the industrial Ethernet switch or network hub.\u003c\/li\u003e\n\u003cli\u003eConfigure \u003cstrong\u003eIP address, subnet mask, and gateway\u003c\/strong\u003e via Unity Pro or Concept programming software.\u003c\/li\u003e\n\u003cli\u003eSet up \u003cstrong\u003eEthernet\/IP scanner configuration\u003c\/strong\u003e for peer-to-peer communication with other Ethernet\/IP devices.\u003c\/li\u003e\n\u003cli\u003eConfigure \u003cstrong\u003eModbus TCP\/IP server parameters\u003c\/strong\u003e (port 502) for HMI\/SCADA connectivity.\u003c\/li\u003e\n\u003cli\u003eEnable \u003cstrong\u003eSNMP\u003c\/strong\u003e for network management if required by your IT infrastructure.\u003c\/li\u003e\n\u003cli\u003eVerify \u003cstrong\u003elink LED\u003c\/strong\u003e and \u003cstrong\u003eactivity LED\u003c\/strong\u003e on the module front panel.\u003c\/li\u003e\n\u003cli\u003eTest communication via \u003cstrong\u003eping\u003c\/strong\u003e and \u003cstrong\u003eModbus TCP read\/write\u003c\/strong\u003e operations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is 140NOC77100 still in production?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e The 140NOC77100 is \u003cstrong\u003ediscontinued\u003c\/strong\u003e. Schneider Electric recommends the \u003cstrong\u003eBMENOC0301\u003c\/strong\u003e as the replacement for new M580 systems. For Quantum systems, consider upgrading to M580 with BMENOC0301.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 140NOC77100 and 140NOE77101?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003e140NOC77100\u003c\/strong\u003e is an \u003cstrong\u003eEthernet\/IP\u003c\/strong\u003e module (supports Ethernet\/IP scanner\/adapter + Modbus TCP). \u003cstrong\u003e140NOE77101\u003c\/strong\u003e is a \u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e module (Modbus TCP only, no Ethernet\/IP). Both provide RJ45 10\/100 Mbit\/s connectivity but with different protocol support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 140NOC77100 and BMENOC0301?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003e140NOC77100\u003c\/strong\u003e is for \u003cstrong\u003eQuantum\u003c\/strong\u003e systems (discontinued). \u003cstrong\u003eBMENOC0301\u003c\/strong\u003e is for \u003cstrong\u003eM580\u003c\/strong\u003e systems (current production), supporting both Ethernet\/IP and Modbus TCP simultaneously, with 3 RJ45 ports, RSTP ring topology, QoS, and embedded HTML5 Web server.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Ethernet\/IP devices can I connect?\u003c\/strong\u003e\u003cbr\u003eA: Up to \u003cstrong\u003e128 simultaneous connections\u003c\/strong\u003e total (combined Ethernet\/IP + Modbus TCP). The exact distribution depends on your application configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use 140NOC77100 with M580?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e 140NOC77100 is designed for \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e racks only. M580 uses BMENOC0301 or BMENOC0311 communication modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does 140NOC77100 support fiber optic?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e The 140NOC77100 has a single \u003cstrong\u003eRJ45 copper port\u003c\/strong\u003e. For fiber optic connectivity, use an external media converter or consider 140NOC78000 (if available) with SFP fiber option.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantum, Ethernet\/IP + Modbus TCP, RJ45:\u003c\/strong\u003e 140NOC77100 (legacy, if stock available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantum, Modbus TCP only:\u003c\/strong\u003e 140NOE77101 \/ 140NOE77111 (with FactoryCast Web server)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, Ethernet\/IP + Modbus TCP, 3×RJ45:\u003c\/strong\u003e BMENOC0301 (recommended replacement)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, Ethernet\/IP + Modbus TCP, 2×RJ45 + 1×SFP:\u003c\/strong\u003e BMENOC0311\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Protocol requirements (Ethernet\/IP vs Modbus TCP), number of connections needed, and system platform (Quantum vs M580) before ordering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor new projects:\u003c\/strong\u003e Migrate to M580 with BMENOC0301 for long-term support\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53759502876856,"sku":"140NOC77100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140NOC77100_50b5e31d-7f15-42f9-86bf-b2e1995ec302.png?v=1783925857","url":"https:\/\/www.globalpetroparts.com\/products\/140noc77100-schneider-modicon-140-ethernet-ip-network-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}