{"product_id":"140noe77101-schneider-electric-quantum-ethernet-tcp-ip-module","title":"140NOE77101 Schneider Electric Quantum Ethernet TCP\/IP Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e140NOE77101 (Part Number: 140NOE77101)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet communication interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It connects Quantum PLCs to standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet TCP\/IP networks\u003c\/strong\u003e, enabling peer-to-peer communication, HMI\/SCADA connectivity, and programming.\u003c\/p\u003e\n\u003cp\u003eThe module supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebuilt-in HTTP server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor remote diagnostics and monitoring, handles intensive data traffic efficiently, and includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflash memory for firmware updates\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × RJ45, 10\/100 Mbps, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServices Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP (Client\/Server), HTTP Web Server, BOOTP\/DHCP, SNMP, FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware or hardware (MAC Address)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmbedded Web Server\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData Editor, Rack Viewer, Ethernet Statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 mA from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s (Full\/Half Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: RUN, ERR, COL\u003cbr\u003eNetwork: ACT, LINK, 100MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.345 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale distributed control systems (DCS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData logging and remote telemetry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterlocking between multiple PLC racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with SCADA systems (Ignition, Wonderware, FactoryTalk View)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot Standby (HSBY) compatible\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-availability communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNot for ERIO scanning\u003c\/strong\u003e; use 140NOC series for Ethernet Remote I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeb server access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia standard browser using module IP; no special software required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52506591592632,"sku":"140NOE77101","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140NOE771012.jpg?v=1769496347","url":"https:\/\/www.globalpetroparts.com\/products\/140noe77101-schneider-electric-quantum-ethernet-tcp-ip-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}