{"product_id":"1701-06-141377-01-bently-nevada-isolator-terminal-base","title":"1701\/06 141377-01 | Bently Nevada | Isolator Terminal Base","description":"\u003cp\u003eConfigured for signal conditioning and noise reduction in machinery monitoring networks, the \u003cstrong\u003eBently Nevada 1701\/06 141377-01\u003c\/strong\u003e (\u003cstrong\u003e1701\/06\u003c\/strong\u003e Isolator Terminal Base) provides direct physical execution of galvanic isolation between vibration sensors and monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e141377-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 mm x 203 mm x 508 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1701\/06 terminal base provides essential signal integrity by decoupling the field-mounted sensor ground from the monitoring system rack ground. This isolation is critical to prevent ground loops that introduce 50\/60 Hz electrical interference into the vibration signal. By ensuring that the eddy-current probe scaling and signal transmission remain undistorted by common-mode noise, the unit maintains the accuracy of rotor dynamics measurements. Effective cross-talk suppression is achieved by minimizing the capacitive coupling of signals within the terminal block, ensuring that high-frequency dynamic vibration data is transmitted with high signal-to-noise ratios.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this terminal base be used in non-Bently Nevada vibration monitoring applications?\u003c\/p\u003e\n\u003cp\u003eA: The terminal base is a passive connectivity component and is compatible with any monitoring system requiring galvanic isolation between industrial vibration transducers and signal processing electronics.\u003c\/p\u003e\n\u003cp\u003eQ: Are there restrictions on the wire gauges used for the screw terminals?\u003c\/p\u003e\n\u003cp\u003eA: The screw terminals are designed to accommodate 12-22 AWG wiring. Ensure all connections are fully tightened to maintain low-resistance signal paths, especially when transmitting low-voltage signals from proximity transducers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Secure the module to a grounded DIN rail to ensure physical stability. Ensure the rail has adequate mechanical clearance to support the 508 mm length of the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: While the unit provides galvanic isolation, ensure that the monitoring system side of the loop is correctly tied to the designated system ground to provide a stable reference for the transducer signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Management\u003c\/strong\u003e: Organize field wiring away from high-voltage power lines. Utilize shielded cabling for all sensor inputs to maximize the benefits of the terminal base's isolation capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Integrity\u003c\/strong\u003e: Periodically verify that screw terminal connections are secure, as thermal expansion and machine vibration can lead to loose connections over long operational cycles.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53601505181880,"sku":"1701\/06 141377-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/141377-01.png?v=1781752516","url":"https:\/\/www.globalpetroparts.com\/products\/1701-06-141377-01-bently-nevada-isolator-terminal-base","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}