{"product_id":"1715-if16-allen-bradley-controllogix-redundant-i-o-16-point-analog-input-module","title":"1715-IF16 | Allen-Bradley ControlLogix Redundant I\/O 16-Point Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1715-IF16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, 16-point analog input module specifically engineered for the 1715 Redundant I\/O platform. This module provides critical data acquisition for fault-tolerant systems, ensuring continuous operation in high-availability environments like oil and gas, power generation, and chemical processing. It bridges the gap between field sensors and the ControlLogix controller while maintaining system integrity during hardware maintenance. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, direct from factory-sealed stock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1715-IF16 utilizes a rugged hardware architecture to handle complex analog signals under harsh industrial conditions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-Point Analog Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18 to 32 Volts DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Watts Maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-25 to 70 °C (-13 to 158 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e22 to 16 AWG Shielded Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Category:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCategory 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.25 lbs (0.57 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 1715 Redundant I\/O Adapters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Continuity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1715-IF16 architecture supports redundant pair configurations. If one module fails, the secondary module maintains the input signal without interrupting the process, eliminating costly downtime in critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Thermal Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard I\/O modules, the 1715-IF16 operates reliably across an expanded temperature range of -25 to 70 °C. This resilience allows for installation in remote field enclosures where climate control is unavailable or unreliable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy requiring Category 2 shielded wiring (22 to 16 AWG), the module effectively rejects electromagnetic interference (EMI). This ensures clean data transmission from field transmitters even in electrically noisy environments near high-voltage drives or motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy-Efficient Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module limits power dissipation to just 4 Watts. This low thermal output prevents heat buildup within high-density control cabinets, extending the lifespan of adjacent electronic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Replacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1715 platform allows for Removal and Insertion Under Power (RIUP). Maintenance teams replace faulty modules while the system remains live, ensuring the Human Interface Station (HIS) never loses visibility of the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1715-IF16 require a specific terminal base for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module must seat into a 1715-A3IO or 1715-A2IO I\/O base unit. This base facilitates the redundant backplane connection and provides the landing points for field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module in a non-redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While designed for redundancy, the 1715-IF16 functions as a standard high-density analog input module. However, you maximize its value in \"Dual\" or \"Redundant\" modes where uptime is the priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of analog signals does it support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1715-IF16 typically processes standard 4-20mA or 0-20mA current loops. Always verify your transmitter scaling and loop power requirements before final commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the module meets the Category 2 wiring standard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUtilize shielded twisted-pair cables and ensure proper grounding at the terminal base or the chassis ground bar. Following these guidelines prevents common-mode noise from corrupting your 16-bit analog data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53371868807352,"sku":"1715-IF16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1715-IF16.jpg?v=1776676556","url":"https:\/\/www.globalpetroparts.com\/products\/1715-if16-allen-bradley-controllogix-redundant-i-o-16-point-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}