{"product_id":"1746-nio4i-allen-bradley-slc-500-analog-combination-i-o-module","title":"1746-NIO4I | Allen Bradley | SLC 500 Analog Combination I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1746-NIO4I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision analog combination module for the SLC 500 PLC platform. This module integrates two input channels and two output channels into a single-slot form factor, providing a cost-effective solution for small-scale PID loops and process monitoring. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original condition\u003c\/strong\u003e, ensuring that your legacy systems maintain peak accuracy and operational continuity without the risks of used components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1746-NIO4I delivers professional-grade signal conversion and high-speed processing for industrial variables:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Combination (Input\/Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +20 mA; -10 to +10V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to +10V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit (Input); 14-bit (Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 microseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStep Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60ms (Input); 2.5ms (Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V Tested\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55mA @ 5V DC; 145mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Signal Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit input resolution allows the module to detect minute changes in process variables. This precision proves vital for applications requiring tight tolerances, such as chemical dosing or temperature regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Control Loop Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA lightning-fast 512-microsecond update time minimizes latency between signal detection and logic execution. This speed ensures that your SLC 500 system responds almost instantaneously to dynamic process fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy combining both inputs and outputs on a single card, the 1746-NIO4I frees up valuable chassis slots. This design optimizes cabinet space in compact machine builds where expansion room remains limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features 500V tested voltage isolation. This barrier protects the PLC backplane from field-side electrical noise and ground loops, preventing processor crashes and data corruption in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1746-NIO4I support current (mA) outputs as well as voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. While the inputs support both voltage (-10 to +10V) and current (-20 to +20 mA), the outputs on the 1746-NIO4I provide voltage signals only (-10 to +10V DC). If your application requires 4-20mA outputs, you must select an alternative module like the 1746-NO4I.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix voltage and current signals on the input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You configure each input channel independently. This flexibility allows you to monitor a pressure transducer (4-20mA) and a position sensor (0-10V) simultaneously using the same module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What terminal block does this module require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1746-NIO4I uses standard SLC 500 removable terminal blocks. This feature allows you to replace the module hardware without disconnecting individual field wires, significantly reducing maintenance downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this a refurbished unit, given that the SLC 500 is an older line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe guarantee this product is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original. We maintain high-quality, unused factory stock to support engineers who require the reliability of new hardware for their established SLC 500 installations.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53455508308152,"sku":"1746-NIO41","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1746-NIO41.jpg?v=1778556679","url":"https:\/\/www.globalpetroparts.com\/products\/1746-nio4i-allen-bradley-slc-500-analog-combination-i-o-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}