{"product_id":"1756-l73s-guardlogix-5570-safety-controller-allen-bradley","title":"1756-L73S GuardLogix 5570 Safety Controller | Allen Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1756-L73S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance GuardLogix 5570 safety controller, providing integrated safety and motion control in a single ControlLogix chassis. This processor executes both standard and safety-critical tasks simultaneously, achieving SIL 3 and PLe (Category 4) safety ratings when paired with its dedicated safety partner. It manages high-speed logic and complex safety algorithms across large-scale industrial applications. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and factory-original\u003c\/strong\u003e, ensuring your critical safety infrastructure operates with maximum integrity and compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1756-L73S leverages a dual-processor architecture to ensure diagnostic coverage and fault detection in high-risk environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGuardLogix 5570\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Partner Required\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-L7SP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-Volatile Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 GB (Ships with SD Card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Digital I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Analog I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 USB Port (Programming\/Online Edits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Tasks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Dedicated Task\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Tasks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 Tasks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.5 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety and Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module eliminates the need for independent safety systems. By running safety and standard code in one controller, engineers reduce hardware costs, simplify network architecture, and streamline data sharing between safety and standard logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Diagnostic Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe GuardLogix 5570 series significantly reduces safety reaction times. The processor executes safety tasks with dedicated priority, ensuring the system reaches a safe state instantly during an emergency event or hardware fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Memory Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 8MB of user memory and a dedicated 4MB for safety code, the 1756-L73S handles massive instruction sets without sacrificing scan times. The included 1GB non-volatile memory card secures your firmware and project files against power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Commissioning via USB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in USB port provides high-speed access for firmware updates, programming, and online diagnostics. This eliminates the requirement for complex network configurations during initial setup and field maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30V continuous isolation protects the internal processor logic from external electrical noise and backplane transients, ensuring stable operation in high-interference industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1756-L73S operate without the 1756-L7SP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. To achieve safety-rated functionality, you must pair the 1756-L73S with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-L7SP safety partner controller\u003c\/strong\u003e. The primary controller handles the standard and safety logic, while the partner provides the necessary redundancy and cross-checking required for SIL 3 compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit provided with the original factory seal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in their original Allen Bradley packaging. Each controller ships with its factory-installed 1GB SD card and documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller support ControlLogix redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-L73S does not support standard ControlLogix redundancy (e.g., via 1756-RM2). It focuses specifically on safety redundancy through the GuardLogix partner-processor architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage the safety signature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller utilizes a safety signature to lock and protect safety-critical code. Once you validate your safety program, you generate a unique signature that prevents unauthorized or accidental modifications to the safety logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53442055667896,"sku":"1756-L73S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1756-L73S.jpg?v=1778141985","url":"https:\/\/www.globalpetroparts.com\/products\/1756-l73s-guardlogix-5570-safety-controller-allen-bradley","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}