{"product_id":"1762-l40bwa-micrologix-1200-controller-allen-bradley","title":"1762-L40BWA MicroLogix 1200 Controller | Allen-Bradley","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-L40BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a powerhouse within the MicroLogix 1200 family, providing high-density I\/O in a compact, cost-effective package. This controller targets applications requiring significant discrete I\/O counts without the footprint of a modular rack system. It manages complex logic via 24 onboard 24V DC inputs and 16 robust relay outputs. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, factory-sealed to guarantee the integrity of your mission-critical automation processes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V AC (Auto-Sensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 (20 Standard, 4 Fast 24V DC Inputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 kΩ (Inputs 0-3); 2.7 kΩ (Inputs 4+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Leakage Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 mA (Off-state)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.791 Nm (7 lb-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Input Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller combines 20 standard inputs with 4 high-speed \"Fast\" inputs. These fast inputs interface directly with high-frequency pulse devices like encoders or flow meters, eliminating the need for expensive dedicated counter modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Relay Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 relay outputs handle both AC and DC loads across a wide voltage range. This flexibility allows the 1762-L40BWA to switch solenoids, motor starters, and pilot lights directly from the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite the 40-point density, the unit dissipates only 22 Watts of heat. This efficiency prevents thermal buildup in small wall-mount enclosures and extends the lifespan of adjacent electronic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal blocks support a torque rating of 0.791 Nm. This high clamping force secures wiring against the constant vibrations found in pumping stations and conveyor headers, preventing intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I expand the I\/O capacity of the 1762-L40BWA?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The MicroLogix 1200 bus supports 1762 expansion modules. You simply remove the expansion port cover on the right side of the unit to add analog, digital, or specialty modules to match your evolving system requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model require a separate 24V DC power supply for logic?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 1762-L40BWA accepts 120\/240V AC line voltage. It features an internal power supply that energizes the CPU and provides power for the integrated I\/O. However, you must provide external 24V DC for the input sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 4 \"Fast\" inputs?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInputs 0 through 3 support high-speed latching and pulse-catching. If your application involves high-speed packaging or counting pulses faster than a standard PLC scan time, these inputs ensure you never miss a trigger event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the memory non-volatile?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1762-L40BWA stores the user program in flash memory. While the unit retains the program without power, we recommend using a backup battery (1747-BA) if you need to preserve retentive data values during extended power outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414099615928,"sku":"1762-L40BWA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1762-L40BWA.jpg?v=1777364749","url":"https:\/\/www.globalpetroparts.com\/products\/1762-l40bwa-micrologix-1200-controller-allen-bradley","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}