{"product_id":"1783-etap1f-allen-bradley-stratix-ethernet-ip-fiber-tap","title":"1783-ETAP1F | Allen-Bradley Stratix EtherNet\/IP Fiber Tap","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1783-ETAP1F\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential connectivity for Device Level Ring (DLR) topologies, enabling non-DLR devices to connect to high-availability networks. This module integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo copper RJ45 ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eone single-port fiber interface\u003c\/strong\u003e, allowing seamless transition between standard Ethernet cabling and long-distance fiber optics. It acts as a critical node in industrial automation, ensuring network resiliency and reducing downtime in the event of a cable failure. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, original factory stock to guarantee optimal signal integrity for your mission-critical infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1783-ETAP1F offers high-performance throughput with the following technical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTap Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiber, Single-Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Copper (RJ45), 1 Fiber Optic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC (Range: 20.4–27.6V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower\/Heat Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCopper Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 (IEC 60603-7), Cat5e Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Wire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.33…3.3 mm² (22…12 AWG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eT5 (North American \u0026amp; IEC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.49 cm x 3.5 cm x 13.16 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.76 kg (1.67 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Distance Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe fiber optic port overcomes the 100-meter limitation of standard copper Ethernet. It enables reliable data transmission across large factory floors or between separate buildings while providing total immunity to electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Availability Ring Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis tap enables the integration of single-port devices into a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDevice Level Ring (DLR)\u003c\/strong\u003e. By doing so, it maintains network communication even if one segment of the ring breaks, providing a self-healing architecture for continuous production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified DIN Rail Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact, slim profile saves valuable space in crowded control cabinets. The open-style enclosure dissipates heat efficiently, allowing for a T5 temperature rating suitable for diverse industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Wiring Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DC power terminal supports both solid and stranded copper wire with a wide gauge range (22–12 AWG). This flexibility allows engineers to utilize existing power distribution architectures without requiring specialized adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why should I choose the 1783-ETAP1F over the standard 1783-ETAP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"1F\" designation indicates a fiber optic port. Use this model if your network topology requires long-distance runs or must pass through areas with high electrical noise that would degrade signals on copper lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require specialized software for configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou can configure the tap via its internal web server or through Studio 5000 Logix Designer software. It supports standard EtherNet\/IP objects for diagnostic monitoring within your PLC program.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of fiber cable does the 1783-ETAP1F require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must use fiber cables compatible with the specific transceiver specifications of the unit (check the specific series label for Multi-mode vs Single-mode requirements) and ensure clean connections to prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I replace a failed unit with this \"Brand New\" stock without reprogramming?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, provided you match the IP address settings (via rotary switches or software) and the firmware compatibility with your existing DLR supervisor, the 1783-ETAP1F will integrate into the ring immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53286060556472,"sku":"1783-ETAP1F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1783-ETAP1F1.jpg?v=1775812955","url":"https:\/\/www.globalpetroparts.com\/products\/1783-etap1f-allen-bradley-stratix-ethernet-ip-fiber-tap","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}