{"product_id":"1784-sd1-compactlogix-1-gb-secure-digital-sd-card-allen-bradley","title":"1784-SD1 CompactLogix 1 GB Secure Digital (SD) Card | Allen-Bradley","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1784-SD1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary industrial-grade non-volatile storage solution for modern ControlLogix and CompactLogix 5370 controller platforms. This 1-Gigabyte Secure Digital (SD) card stores critical project files, user-defined data logs, and firmware images, enabling rapid controller restoration without a PC. Unlike commercial-grade SD cards, the 1784-SD1 features a hardened architecture designed to withstand the thermal and mechanical stresses of factory-floor environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system utilizes the precise flash timing and endurance levels specified by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Gigabyte (1 GB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-Grade Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFile System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFAT16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 G @ 10 to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-Operating Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eESD Immunity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kV (Contact) \/ 8 kV (Air)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Endurance and Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1784-SD1 utilizes high-endurance flash cells that far exceed the write-cycle limits of consumer media. This prevents data corruption during frequent logging operations or repeated power-cycling events common in industrial facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Environmental Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card manages 2 G of vibration and up to 30 G of operational shock. These specifications ensure the memory remains seated and functional in cabinets mounted directly onto vibrating machinery or heavy-duty processing equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Controller Recovery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a processor fault or power loss, the 1784-SD1 allows the controller to reload the user program automatically. This feature eliminates the need for maintenance personnel to manually download code via a laptop, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced ESD Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith immunity up to 8 kV air discharge, the 1784-SD1 resists damage from static electricity during handling or insertion. This robustness protects the internal controller backplane from potential electrical transients during maintenance routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a standard commercial SD card instead of the 1784-SD1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. Commercial cards lack the vibration resistance and thermal specifications required for industrial controllers. Using non-industrial cards often leads to \"Media Fault\" errors, corrupted firmware, and voided hardware warranties.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1784-SD1 require formatting before installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1784-SD1 arrives factory-formatted with a specific 16-bit FAT16 file system optimized for Logix controllers. We recommend inserting the card directly into the controller without modification to maintain file structure integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the \"Load on Power Up\" feature work with this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou configure this setting within the Studio 5000 software. Once enabled, the controller checks the 1784-SD1 during every power cycle. If it detects a stored project, it clears the local volatile memory and loads the project from the SD card, ensuring the machine always runs the correct version of the code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this card compatible with older PLC-5 systems despite the \"Product Line\" listing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile some legacy documentation references the PLC-5 product line for peripheral accessories, this card primarily targets CompactLogix 5370 and ControlLogix 5570\/5580 controllers. Always verify your specific processor's hardware manual to confirm SD slot compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414141853880,"sku":"1784-SD1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1784-SD1.jpg?v=1777367328","url":"https:\/\/www.globalpetroparts.com\/products\/1784-sd1-compactlogix-1-gb-secure-digital-sd-card-allen-bradley","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}