{"product_id":"1x00707h06-westinghouse-ovation-din-rail-mount-circuit-breaker","title":"1X00707H06 | Westinghouse Ovation | DIN Rail Mount Circuit Breaker","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 1X00707H06\u003c\/strong\u003e is a \u003cstrong\u003eDIN Rail Mount Circuit Breaker\u003c\/strong\u003e for Emerson Ovation distributed control systems. It provides \u003cstrong\u003e250V DC, 25A, 2-pole\u003c\/strong\u003e branch circuit protection with \u003cstrong\u003eUL489 certification\u003c\/strong\u003e, safeguarding Ovation I\/O modules and power supplies from overcurrent conditions in industrial control cabinets.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 1X00707H06\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e DIN Rail Mount Circuit Breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 250V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 25A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 2-pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e D-Trip (magnetic trip characteristic)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL489 Branch Circuit Rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson (formerly Westinghouse)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUL489 branch circuit protection for Ovation DCS power distribution\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting for standard industrial control cabinet installation\u003c\/li\u003e\n  \u003cli\u003eD-Trip characteristic provides fast response to short-circuit faults\u003c\/li\u003e\n  \u003cli\u003e250V DC rating suitable for Ovation 24V DC auxiliary power systems\u003c\/li\u003e\n  \u003cli\u003e2-pole configuration isolates both positive and negative conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C (-4°F to 140°F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the 1X00707H06 used for?\u003c\/h4\u003e\n\u003cp\u003eIt is a DIN rail mount circuit breaker providing overcurrent protection for Emerson Ovation DCS power distribution circuits.\u003c\/p\u003e\n\n\u003ch4\u003eWhat does D-Trip mean?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eD-Trip\u003c\/strong\u003e (or D-curve) indicates a magnetic trip characteristic with 10-20x rated current instantaneous trip, suitable for circuits with moderate inrush currents.\u003c\/p\u003e\n\n\u003ch4\u003eIs this UL listed?\u003c\/h4\u003e\n\u003cp\u003eYes — it carries \u003cstrong\u003eUL489 Branch Circuit\u003c\/strong\u003e certification, meeting North American electrical safety standards.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between 1X00707H06 and standard circuit breakers?\u003c\/h4\u003e\n\u003cp\u003eThe 1X00707H06 is specifically selected and cataloged by Emerson for Ovation DCS installations, ensuring compatibility with system voltage and current requirements.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003ch4\u003eSafety Precautions\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-energize the power source before installation\u003c\/li\u003e\n  \u003cli\u003eVerify circuit voltage and current ratings match the breaker\u003c\/li\u003e\n  \u003cli\u003eUse appropriate wire gauge for 25A rating (minimum 10 AWG)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStep-by-Step Procedure\u003c\/h4\u003e\n\u003col\u003e\n  \u003cli\u003eMount the breaker onto the DIN rail in the Ovation cabinet\u003c\/li\u003e\n  \u003cli\u003eConnect line side conductors to top terminals (polarity observed for DC)\u003c\/li\u003e\n  \u003cli\u003eConnect load side conductors to bottom terminals\u003c\/li\u003e\n  \u003cli\u003eTorque terminal screws to manufacturer specification\u003c\/li\u003e\n  \u003cli\u003eEnergize and verify proper operation via test button\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify total load current does not exceed 25A breaker rating\u003c\/li\u003e\n  \u003cli\u003eFor Ovation systems, use only Emerson-specified breakers for warranty compliance\u003c\/li\u003e\n  \u003cli\u003eConsider upstream coordination with panel main breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1X00781H01L — DIN-Rail Power Supply, 24VDC, 10A\u003c\/li\u003e\n  \u003cli\u003e1X00416H01 — Ovation Power Supply Module, WH5-2FF\u003c\/li\u003e\n  \u003cli\u003e1X00024H01 — Ovation AC Power Supply Module, WH1-2FF\u003c\/li\u003e\n  \u003cli\u003e1X00884H01 — PMOD Cavity Insert, Events Input Contact Input 32CH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53684530446520,"sku":"1X00707H06","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1X00102H01_2.png?v=1782979611","url":"https:\/\/www.globalpetroparts.com\/products\/1x00707h06-westinghouse-ovation-din-rail-mount-circuit-breaker","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}