{"product_id":"2711c-t10c-allen-bradley-panelview-component-c1000-touchscreen-terminal","title":"2711C-T10C | Allen Bradley | PanelView Component C1000 Touchscreen Terminal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2711C-T10C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-efficiency operator interface within the PanelView Component C1000 series. This 10-inch color terminal streamlines machine-level control by providing a sharp\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$640 \\times 480$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eresolution display for real-time data visualization. It supports multi-vendor environments, allowing direct connection to both Rockwell and third-party controllers like Siemens and Modbus-based devices. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Original\u003c\/strong\u003e, ensuring peak performance for your automation architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eColor Transmissive TFT Active Matrix LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.4-inch (211 x 158 mm active area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e640 x 480 VGA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Touch (1 Million Actuations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–30V DC (24V DC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Watts (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 (DF1\/DH-485), RS-485, USB Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBacklight Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50,000 Hours Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.69 lbs (1.67 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2711C-T10C integrates RS-232 and RS-485 ports natively. This enables the terminal to communicate with Siemens MPI and Modbus devices without requiring expensive external protocol converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrowser-Based Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis HMI eliminates the need for complex software installations. Engineers design and edit applications directly through a web browser (Internet Explorer or Firefox), simplifying on-site modifications and remote troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Power Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit consumes only 5 Watts of power. This low thermal footprint permits installation in smaller, non-ventilated enclosures without risking heat-induced processor throttling or display degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe analog touchscreen withstands over 1 million physical presses. This rugged construction ensures reliable input response in high-traffic production environments where operators wear gloves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 2711C-T10C replace older PanelView Standard units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the PanelView Component series uses different design software, its multi-vendor communication capabilities allow it to take over tasks previously handled by older 10-inch terminals. Verify your existing communication protocol (DF1 or DH-485) before migrating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle the \"Obsolete\" status for a new project?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough Rockwell classifies this series as discontinued, we stock\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits. This allows you to maintain existing machine designs without the massive engineering costs of upgrading to a different HMI platform or modifying panel cutouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary maintenance requirement for the backlight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe backlight provides a 50,000-hour service life but remains non-replaceable. To maximize longevity, we recommend utilizing the integrated screen saver functions to dim the display during periods of inactivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit operates on a standard 24V DC industrial power loop. Ensure your power supply maintains a range between 18V and 30V DC to prevent communication drops or hardware resets during motor starts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53446789791928,"sku":"2711C-T10C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2711C-T10C.jpg?v=1778227049","url":"https:\/\/www.globalpetroparts.com\/products\/2711c-t10c-allen-bradley-panelview-component-c1000-touchscreen-terminal","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}