{"product_id":"2711p-rdt10c-allen-bradley-panelview-plus-display-module","title":"2711P-RDT10C | Allen-Bradley | PanelView Plus Display Module","description":"\u003cp\u003eConfigured for process visualization in control environments, the \u003cstrong\u003eAllen-Bradley 2711P-RDT10C\u003c\/strong\u003e (\u003cstrong\u003e2711P-RDT10C\u003c\/strong\u003e Operator Interface) provides direct physical execution of graphical display functions. This display module, designed for the PanelView Plus 1000 series, incorporates a 10.4-inch color TFT touchscreen to interface with host logic modules, enabling operator interaction with control system parameters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-RDT10C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.81 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eDisplay Module Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RDT10C serves as the visual front-end for PanelView Plus 1000 architectures. As a display-only module, it relies on the coupled logic module for communication protocol handling. Firmware flash compatibility is mandatory; ensure that the display module firmware is compatible with the version installed on the logic module to prevent graphical artifacts or touchscreen input registration errors. Deterministic network performance remains the responsibility of the host controller and communication module; however, verify that the terminal's refresh rate settings are synchronized with the PLC communication polling interval to ensure operator data reflects current process states.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 2711P-RDT10C display module compatible with all PanelView Plus 1000 logic modules?\u003c\/p\u003e\n\u003cp\u003eA: This module is designed for the PanelView Plus 1000 platform. Compatibility with specific logic module variants must be verified against the hardware revision matrix to ensure electrical and mechanical inter-module communication is supported.\u003c\/p\u003e\n\u003cp\u003eQ: Can this display module be replaced while the logic module is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be disconnected from the logic module prior to unseating the display module. Hot-swapping the display module assembly can lead to backplane connector damage or unexpected electrical transients that may disrupt the logic module's operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Align the display module with the logic module's interface connector. Ensure that the mechanical latching points are fully engaged to provide structural integrity when mounted in an enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGasket Sealing\u003c\/strong\u003e: Inspect the perimeter gasket for any debris or physical damage prior to installation. A compromised gasket will fail to maintain the NEMA\/IP rating of the host enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen Care\u003c\/strong\u003e: Do not use abrasive cleaning agents on the touchscreen surface. Use only lint-free cloths and non-conductive, mild cleaning solutions to prevent scratching the TFT overlay or damaging the touch-sensitive grid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the terminal assembly is properly bonded to the cabinet chassis through the mounting hardware to maintain shielding against electromagnetic interference that may affect the display's color uniformity or touchscreen accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53542658474168,"sku":"2711P-RDR10C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2711P-T10C4D8_5edca77e-ea86-4f5e-93aa-58c0ef55065d.jpg?v=1780480400","url":"https:\/\/www.globalpetroparts.com\/products\/2711p-rdt10c-allen-bradley-panelview-plus-display-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}