{"product_id":"2711p-t10c15d8-allen-bradley-panelview-plus-6-operator-terminal","title":"2711P-T10C15D8 | Allen Bradley | PanelView Plus 6 Operator Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 2711P-T10C15D8\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711P-T10C15D8\u003c\/strong\u003e Operator Terminal, operates as a dedicated hardware component for process visualization and real-time machine diagnostics within EtherNet\/IP enabled controller architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T10C15D8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.07 lbs (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.4 inch TFT display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W (2.9 A at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM \/ 512 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 (VGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T10C15D8 integrates into EtherNet\/IP networks, maintaining communication velocity through a 10\/100 Ethernet interface. Deterministic data exchange with Logix5000 controllers is managed via the Windows CE 6.0 operating system, which handles tag updates and alarm management cycles. Firmware flash compatibility is managed through the USB host ports, ensuring the terminal maintains alignment with FactoryTalk View Studio ME project requirements. I\/O density scaling and tag throughput are dependent on system RAM availability, with optimal performance maintained under standard application complexity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this HMI be powered by a 120 VAC source?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit is designed exclusively for 18–30 VDC input. A regulated industrial power supply must be utilized if only AC power is present within the control cabinet.\u003c\/p\u003e\n\u003cp\u003eQ: Is the resistive analog touchscreen assembly field-replaceable?\u003c\/p\u003e\n\u003cp\u003eA: No. The touchscreen is integrated into the front bezel and display assembly. Component failure requires the replacement of the entire display module.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit support storage expansion?\u003c\/p\u003e\n\u003cp\u003eA: Yes. An integrated SD card slot is available behind the unit to expand non-volatile storage capacity for data logging and recipe management files.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Preparation:\u003c\/strong\u003e Cut the enclosure panel according to the manufacturer specifications. Ensure the surface is flat and clean to maintain the NEMA 4X\/IP66 seal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the terminal into the panel cutout and engage the provided mounting levers. Tighten the levers to apply constant pressure, ensuring the gasket is compressed evenly against the enclosure frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum of 2 inches (50 mm) of clearance behind the unit to allow for convective heat dissipation and access to the SD card slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Connect the 24 VDC power supply to the terminal input. Use shielded cabling for the DC supply to minimize EMI and terminate the chassis ground stud to the main cabinet ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Usage:\u003c\/strong\u003e Use the Ethernet port for primary communication with Logix5000 controllers. Reserve the USB ports for maintenance tasks, such as application uploads, firmware updates, or peripheral keyboard\/mouse connection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53523370934456,"sku":"2711P-T10C15D8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2711P-T10C4D8_56ddbf8f-88f9-4318-a469-96d85804e067.jpg?v=1780026241","url":"https:\/\/www.globalpetroparts.com\/products\/2711p-t10c15d8-allen-bradley-panelview-plus-6-operator-terminal","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}