{"product_id":"2711p-t10c22d8s-allen-bradley-panelview-plus-7-terminal","title":"2711P-T10C22D8S | Allen-Bradley | PanelView Plus 7 Terminal","description":"\u003cp\u003eConfigured for graphical operator interface visualization in industrial control networks, the \u003cstrong\u003eAllen-Bradley 2711P-T10C22D8S\u003c\/strong\u003e (\u003cstrong\u003e2711P-T10C22D8S\u003c\/strong\u003e HMI Terminal) provides direct human-machine interaction and real-time data monitoring. The unit features a 10.4-inch thin-film-transistor (TFT) touch screen capable of rendering 800 x 600 SVGA resolution with 18-bit color graphics, facilitating operator command input and process status reporting via an integrated 24 V DC power supply.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T10C22D8S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.84 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e267 x 214 x 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.4-inch TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e800 x 600 SVGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e2-Port Ethernet DLR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-T10C22D8S is engineered for integration within high-availability industrial networks, specifically supporting Device Level Ring (DLR) topology via its dual-port Ethernet interface. This configuration ensures deterministic communication between the HMI and the controller, minimizing recovery time in the event of a single-point network failure. Effective utilization of this interface requires verification of firmware flash compatibility to maintain synchronization with the backplane bus communication velocity of the connected controller platform. Proper network configuration prevents data packet collisions and ensures real-time updates for critical process parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this terminal support field replacement of the backlight?\u003c\/p\u003e\n\u003cp\u003eA: No. The backlight assembly is integrated into the display module. Field maintenance is restricted to cleaning the touch surface and replacing the protective bezel overlay or the input power terminal block.\u003c\/p\u003e\n\u003cp\u003eQ: Can the dual Ethernet ports be configured for independent IP addresses?\u003c\/p\u003e\n\u003cp\u003eA: No. The two Ethernet ports on this terminal are internally switched to support DLR or linear network topologies; they operate within the same subnet and share a single logical IP address.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout\u003c\/strong\u003e: Utilize the provided template to ensure accurate dimensions for panel mounting. Maintain a minimum of 50 mm clearance on all sides of the terminal to ensure adequate ventilation and prevent thermal buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Connect the chassis ground terminal to the equipment grounding bus using a low-impedance conductor (min 2.5 mm squared). Do not daisy-chain ground connections; connect each device directly to the cabinet ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e: Ensure the mounting gasket is seated evenly against the cabinet surface to maintain the IP rating. Tighten mounting clips in a cross-pattern to achieve uniform pressure distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief\u003c\/strong\u003e: Utilize cable ties to secure Ethernet and power cables to the cabinet frame near the entry point, preventing mechanical stress on the RJ45 and power terminal connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53559511875768,"sku":"2711P-T10C22D8S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2711P-T10C22D9P_861ebc22-5b0f-4063-8141-762dc18e0b32.jpg?v=1780891196","url":"https:\/\/www.globalpetroparts.com\/products\/2711p-t10c22d8s-allen-bradley-panelview-plus-7-terminal","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}