{"product_id":"330103-00-05-90-02-00-3300-xl-8-mm-proximity-probe-bently-nevada","title":"330103-00-05-90-02-00 3300 XL 8 mm Proximity Probe | Bently Nevada","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-05-90-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary sensor for the 3300 XL 8 mm Proximity Transducer System. This eddy current probe enables non-contact, high-precision measurement of shaft vibration and position in critical rotating machinery. We guarantee this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the exact electrical and mechanical specifications required for OEM machinery protection.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThis specific 330103 configuration provides an extended cable length for direct connection to Proximitors® without intermediate extension cables in certain setups:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e90\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 Metres (29.5 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector\/Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™ connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo hazardous area approvals required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe probe functions as a high-frequency tuned circuit, delivering a voltage output proportional to the distance from the target.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCase Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTip Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePolyphenylene sulfide (PPS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.0 Meters (Integral Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-35 °C to +177 °C (-31 °F to +350 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 mm (80 mils) typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScale Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.87 V\/mm (200 mV\/mil) when properly matched\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended 9.0m Reach:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter integral cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for an extension cable in many installations. By removing the mid-point connection, you reduce the potential for signal contamination and mechanical failure at the junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeep-Reach Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-inch (127 mm) case length\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the probe to penetrate thick bearing housings or outer machine casings, ensuring the tip reaches the target shaft without requiring custom mounting sleeves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClickLoc™ Connection Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClickLoc™ connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a self-locking mechanism. It prevents the cable from backing out under high-vibration conditions, ensuring constant electrical contact and reducing the risk of \"NOT OK\" system status trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PPS tip and stainless steel case body resist moisture, oils, and chemical lubricants. This robust construction ensures long-term measurement stability inside hot, fluid-rich machine environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this 9.0m probe with an extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou should only use this probe with a Proximitor® calibrated for a 9.0-meter system. If you add an extension cable to this 9.0m probe, the total system length will exceed the standard 3300 XL calibration (usually 5m or 9m), resulting in significant measurement errors. This probe typically connects directly to the Proximitor®.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this probe require a special mounting bracket?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it uses standard M10x1 threads (or 3\/8-24 depending on specific series options). The 5.0-inch case length provides ample threading for standard brackets, though we recommend using the included locknuts to secure the final gap position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the probe is \"Brand New\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery unit we ship arrives in its original factory packaging with a clear Bently Nevada serial number. The factory seal and the pristine condition of the gold-plated ClickLoc™ connector and PPS tip confirm its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estatus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the correct gap voltage for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor most 3300 XL 8mm systems, setting the probe to -10.0 VDC (the center of the linear range) provides the best performance. Always use a calibrated Digital Multimeter (DVM) to verify the gap during the installation process.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53280006930616,"sku":"330103-00-05-90-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330103-00-03-10-02-00_01b126d6-0431-43ba-a95d-a167865467a1.jpg?v=1775706557","url":"https:\/\/www.globalpetroparts.com\/products\/330103-00-05-90-02-00-3300-xl-8-mm-proximity-probe-bently-nevada","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}