{"product_id":"330104-00-10-10-02-00-bently-nevada-3300-xl-8mm-proximity-probe","title":"330104-00-10-10-02-00 | Bently Nevada | 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e330104-00-10-10-02-00\u003c\/strong\u003e operates as a high-precision, non-contact eddy current sensor within the industry-standard 3300 XL 8mm proximity transducer platform. This heavy-duty hardware transducer measures static shaft position, axial thrust, and dynamic radial vibration on critical rotating assets, including high-pressure steam turbines, heavy centrifugal fans, and industrial gearboxes.\u003c\/p\u003e\n\u003cp\u003eThe probe tip projects a continuous high-frequency electromagnetic field toward the target shaft, reading micro-inch changes in gap distance with absolute precision. This continuous data stream allows plant operators to detect mechanical anomalies like shaft imbalance or bearing wear before structural damage happens. We supply this mission-critical hardware exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e, which guarantees an unblemished Polyphenylene Sulfide (PPS) tip, untouched gold-plated coaxial contact pins, and pristine factory-stamped calibration profiles.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model number options define the exact mechanical footprint and deployment engineering of the probe structure. The table below decodes the specific design choices for the 330104-00-10-10-02-00 configuration:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eArchitectural Meaning \u0026amp; Engineering Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003e00\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm unthreaded section (Fully threaded barrel body configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003e10\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm total case length housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003e10\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (3.3 feet) total integrated cable length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector \u0026amp; Cable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003e02\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003ccode\u003e00\u003c\/code\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals not required (Standard non-hazardous area deployment)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe list below outlines the primary electrical, physical, and environmental parameters governing the performance of this 3300 XL probe:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensing Tip Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm nominal diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTip Core Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePolyphenylene Sulfide (PPS) high-performance glass-filled engineering plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThreaded Barrel Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAISI 303 stainless steel structural body\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Sizing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 3\/8-24 UNF-2A thread pattern\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear Operating Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 mm (80 mils) total displacement window\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Scale Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.87 V\/mm (200 mV\/mil) when combined with a matching 3300 XL Proximitor sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-51 °C to +177 °C (-60 °F to +350 °F) continuous exposure limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGold-plated ClickLoc miniature coaxial male connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimizes Depth Positioning via a 100mm Fully Threaded Barrel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 100 mm continuous thread design (\u003ccode\u003e10\u003c\/code\u003e\u003cspan\u003e \u003c\/span\u003ecase length with\u003cspan\u003e \u003c\/span\u003e\u003ccode\u003e00\u003c\/code\u003e\u003cspan\u003e \u003c\/span\u003eunthreaded length) allows installers to fine-tune the depth orientation inside thick-walled bearing caps. This extended threading gives technicians the flexibility to position the probe tip at the exact linear voltage sweet spot without ordering custom brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecures Electrical Continuity via ClickLoc Coaxial Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe miniature coaxial interface utilizes a specialized locking ring mechanism. This design resists persistent machinery vibrations and high-frequency resonance inside the fluid housing, preventing the cable connection from rattling loose and avoiding false machine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResists Thermal Fatigue at High-Speed Rotor Housings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe glass-filled PPS tip material withstands severe thermal cycling and exposure to hot synthetic lubricants. The chemical-resistant tip maintains its shape and structural integrity under constant pressure and high temperatures, ensuring reliable gap measurements over years of operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat total electrical system length does this 1.0-meter probe require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330104-00-10-10-02-00 includes an integrated 1.0-meter cable (Option\u003cspan\u003e \u003c\/span\u003e\u003ccode\u003e10\u003c\/code\u003e). To maintain the required 200 mV\/mil scale factor, the overall system must measure exactly 5.0 meters or 9.0 meters. Therefore, technicians must connect this probe to either a 4.0-meter or an 8.0-meter extension cable before routing the signal to the final 3300 XL Proximitor sensor block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should technicians set the physical mechanical gap during a live installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must monitor the DC gap voltage using a digital multimeter hooked up to the Proximitor sensor output terminals while installing the probe. Thread the probe slowly into the mounting port until the multimeter registers approximately -10.0V DC, which represents the precise midpoint of the 2.0 mm linear operating range. Once set, torque the exterior locknut to the factory specification to lock the barrel in place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must installers avoid running this probe close to surrounding side metals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe eddy current field radiates outward from the 8mm tip in a distinct conical shape. If you insert the probe into a narrow mounting hole with insufficient side clearance, the surrounding metal walls will intersect the electromagnetic field, causing cross-talk and distorting the linearity of the output. Maintain a clear radial air gap of at least 3 times the probe tip diameter (24 mm) to prevent edge distortion errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53486749253816,"sku":"330104-00-10-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330104-00-09-10-02-00_2964aca9-19b8-4775-95e9-a21811666edb.png?v=1779262471","url":"https:\/\/www.globalpetroparts.com\/products\/330104-00-10-10-02-00-bently-nevada-3300-xl-8mm-proximity-probe","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}