{"product_id":"330106-05-30-10-02-05-bently-nevada-3300-xl-8-mm-reverse-mount-probes","title":"330106-05-30-10-02-05 | Bently Nevada | 3300 XL 8 mm Reverse Mount Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330106-05-30-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330106\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReverse Mount Probe utilized to execute non-contacting shaft displacement and dynamic vibration measurements across 3500 Machinery Protection System platforms. The module operates via high-frequency eddy-current generation, translating physical proximity changes into corresponding electrical voltage variations when connected to a 3300 XL Proximitor Sensor.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe complete model nomenclature breakdown for this configuration is defined as follows:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330106\u003c\/strong\u003e: Base model number for 3300 XL 8 mm Reverse Mount Probe (3\/8-24 UNF-2A thread parameters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Specifies the unthreaded length option of 0.5 inches (12.7 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e30\u003c\/strong\u003e: Specifies the case length option of 3.0 inches (76.2 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option designating a 1.0 metre (3.3 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector Option specifying a miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency Approval Option designating multiple regional certifications including CSA, ATEX, and IECEx intrinsic safety mandates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330106-05-30-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard reverse mount probe weight class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm (0.5 inches) unthreaded length, 76.2 mm (3.0 inches) case length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor loop (Driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Case Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 or 304 stainless steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Validation and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eMechanical deployment of this transducer relies on physical gap voltage validation to ensure accurate data capture of rotor dynamics. During static adjustment within the reverse mount housing, the probe position must be manipulated relative to the shaft target until a steady-state value of -10 VDC is obtained at the Proximitor output layer. This voltage calibration maps the physical target position to the absolute center of the linear transduction range, which spans 2.0 mm (80 mils). Maintaining this calibrated gap ensures the conversion complies with the factory eddy-current probe scaling factor of 7.87 V\/mm (200 mV\/mil), while integrated cable shielding provides cross-talk suppression against adjacent sensor loops within the machinery casing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does Option 05 agency approval affect field installation parameters?\u003c\/p\u003e\n\u003cp\u003eA: Option 05 indicates certified compliance for explosive atmospheres under ATEX, IECEx, and CSA frameworks. Installation requires routing the sensor circuit through a matching certified intrinsic safety barrier inside the local enclosure to restrict loop energy under fault conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What output behavior occurs at the monitor rack if the ClickLoc connector unlatches during active machinery operation?\u003c\/p\u003e\n\u003cp\u003eA: An unlatched connector forces an open-circuit state across the proximity circuit loop. The Proximitor detects this resistance shift and drives its voltage output to maximum saturation, prompting the monitor card to trigger a NOT OK fault code and inhibit false relay tripping.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Insertion Alignment\u003c\/strong\u003e: Manually thread the 3\/8-24 UNF-2A probe housing into the reverse mount sleeve bracket. Ensure no cross-threading occurs before torque is applied to the locknut assembly to prevent damage to the 76.2 mm case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Bend Path Limitations\u003c\/strong\u003e: Maintain a minimum bend radius of 25.4 mm (1.0 inch) along all segments of the 1.0-meter coaxial cable. Sharp kinks or compressed routing paths degrade insulation layers and compromise shielding performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Separation Requirements\u003c\/strong\u003e: The ClickLoc connector and internal coaxial shield must remain isolated from any contact with the machine chassis or housing. Use insulated junction boxes and matching protective terminal sleeves to maintain a single-point grounding layout at the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Surface Inspection\u003c\/strong\u003e: Confirm the targeted shaft observation track matches calibration criteria and is free of surface scratches or structural magnetism, as these conditions cause electrical runout errors that distort vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53504089161912,"sku":"330106-05-30-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330101-00-08-05-02-00_4caddd64-5220-4814-8afd-d97bfdb69d99.jpg?v=1779687674","url":"https:\/\/www.globalpetroparts.com\/products\/330106-05-30-10-02-05-bently-nevada-3300-xl-8-mm-reverse-mount-probes","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}