{"product_id":"330130-080-01-05-bently-nevada-3300-xl-extension-cable","title":"330130-080-01-05 | Bently Nevada | 3300 XL Extension Cable","description":"\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eConfigured for signal transmission between eddy-current transducers and monitoring instrumentation in machinery protection systems, the \u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eBently Nevada 330130-080-01-05\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e (\u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e330130\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e Extension Cable) provides direct physical signal path continuity for proximity measurement chains.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330130\u003c\/strong\u003e: Base model number for 3300 XL series extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e080\u003c\/strong\u003e: Cable length of 8.0 meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Armored cable construction for mechanical protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Configuration option including specific agency approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-080-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.0 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 XL environmental range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (transmission line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Impedance\u003c\/td\u003e\n\u003ctd\u003e75 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 330130 extension cable maintains the characteristic impedance required for the 3300 XL proximity transducer system. Proper system operation relies on gap voltage validation, with target values typically centered at -10 VDC within the linear operating range. Deviations in cable length or impedance mismatch directly affect the accuracy of rotor dynamics measurements. The design utilizes high-frequency shielding to provide cross-talk suppression in industrial environments, preventing external electromagnetic interference from introducing noise into the transducer signal path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the armored cable be field-terminated or shortened?\u003c\/p\u003e\n\u003cp\u003eA: No. The electrical capacitance and impedance are factory-tuned to the specific length. Any modification to the cable structure or length will invalidate the system calibration and introduce measurement errors.\u003c\/p\u003e\n\u003cp\u003eQ: How should the cable armor be grounded?\u003c\/p\u003e\n\u003cp\u003eA: The armor provides mechanical protection. Ensure the armor is grounded per local electrical codes at the entry point of the junction box if required to maintain effective electromagnetic shielding and prevent ground loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all system power is isolated before disconnecting or connecting transducer components to prevent electrical transients.\u003c\/li\u003e\n\u003cli\u003eRoute the extension cable through dedicated conduit or cable trays to minimize mechanical stress and interference. Ensure the minimum bend radius is maintained to protect the internal coaxial structure.\u003c\/li\u003e\n\u003cli\u003eClean all connector pins with an appropriate electronic contact cleaner prior to mating to ensure optimal signal continuity and minimize resistance at the connection points.\u003c\/li\u003e\n\u003cli\u003eFinger-tighten all coaxial connections. Do not utilize mechanical tools, as over-torquing can damage the internal connector threads or center pin alignment.\u003c\/li\u003e\n\u003cli\u003eVerify that the total system length (Probe + Extension Cable) matches the configuration settings programmed in the monitor or Proximitor module.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53567950422200,"sku":"330130-080-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330130-080-01-05.png?v=1780983670","url":"https:\/\/www.globalpetroparts.com\/products\/330130-080-01-05-bently-nevada-3300-xl-extension-cable","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}