{"product_id":"5201-mnet-mcm-prosoft-modbus-tcp-ip-to-modbus-master-slave-gateway","title":"5201-MNET-MCM | Prosoft Modbus TCP\/IP to Modbus Master\/Slave Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft 5201-MNET-MCM\u003c\/strong\u003e is a \u003cstrong\u003eModular Communication Manager\u003c\/strong\u003e designed for \u003cstrong\u003eRockwell Automation ControlLogix and CompactLogix\u003c\/strong\u003e platforms. This versatile module provides simultaneous \u003cstrong\u003eModbus TCP\/IP and Modbus RTU\/ASCII\u003c\/strong\u003e communication, enabling PLCs to act as both master and slave across multiple networks. With an \u003cstrong\u003eembedded web server\u003c\/strong\u003e for remote configuration and diagnostics, the 5201-MNET-MCM simplifies integration of third-party devices such as drives, meters, and RTUs into Logix environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 5201-MNET-MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Modular Communication Manager (Modbus TCP\/RTU\/ASCII)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft 5200 Communication Manager\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Rockwell ControlLogix, CompactLogix (via 1756 or 1769 backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × 10\/100 Mbps RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e 1 × RS-232 (DB9)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e Modbus TCP\/IP (Master\/Slave), Modbus RTU (Master\/Slave), Modbus ASCII (Master\/Slave), EtherNet\/IP Adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP Clients:\u003c\/strong\u003e Up to 10 simultaneous client connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus TCP Servers:\u003c\/strong\u003e Up to 5 MBAP + 5 encapsulated server connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Serial:\u003c\/strong\u003e Configurable as RS-232 or RS-485 (2-wire\/4-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Web browser, ProSoft Configuration Studio, RSLogix 5000\/Studio 5000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Backplane powered (5VDC\/24VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, FCC, ATEX (model dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Protocol Flexibility:\u003c\/strong\u003e Simultaneous Modbus TCP, RTU, and ASCII support in one module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Master\/Slave:\u003c\/strong\u003e Operates as Modbus Master or Slave on both Ethernet and serial interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Web Server:\u003c\/strong\u003e Configure, monitor, and diagnose via any standard web browser — no specialized software required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Logix Integration:\u003c\/strong\u003e Data maps directly to PLC I\/O data areas (N7, B3, etc.) for immediate program access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Storage:\u003c\/strong\u003e Configuration retained in internal memory across power cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Single-slot module minimizes rack space requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-brand production lines integrating Siemens VFDs, Schneider meters, and Rockwell PLCs\u003c\/li\u003e\n\u003cli\u003eWater treatment SCADA with legacy Modbus RTU telemetry and modern Modbus TCP SCADA\u003c\/li\u003e\n\u003cli\u003eBuilding automation HVAC integration via Modbus serial and Ethernet BMS networks\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas wellhead data aggregation from Modbus RTU flow computers into ControlLogix\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Turn OFF rack power before installing the 5201-MNET-MCM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the module into any available I\/O slot on the ControlLogix or CompactLogix rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 port to your plant network using Cat 5e cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Connection:\u003c\/strong\u003e Connect RS-232\/485 serial devices to the DB9 port using appropriate cabling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Configuration:\u003c\/strong\u003e Access the module's default IP via web browser and configure network parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Setup:\u003c\/strong\u003e Define Modbus TCP client\/server settings and serial port parameters (baud, parity, mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Mapping:\u003c\/strong\u003e Map Modbus registers to PLC data files using the configuration interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the module to your project and reference the mapped data tags in ladder logic\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module with Micro800 controllers?\u003c\/strong\u003e\u003cbr\u003e\nA: The 5201-MNET-MCM is designed for \u003cstrong\u003eControlLogix and CompactLogix\u003c\/strong\u003e platforms. For Micro800, consult ProSoft for compatible communication adapters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it support EtherNet\/IP explicit messaging?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the module includes an \u003cstrong\u003eEtherNet\/IP Adapter interface\u003c\/strong\u003e for integration into EtherNet\/IP scanner networks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How many serial devices can I connect?\u003c\/strong\u003e\u003cbr\u003e\nA: The single serial port supports \u003cstrong\u003eone RS-232\/485 network\u003c\/strong\u003e. For multi-drop RS-485, up to 247 devices can be addressed via Modbus RTU.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the web interface secure?\u003c\/strong\u003e\u003cbr\u003e\nA: The embedded web server provides configuration and monitoring. For secure environments, deploy behind a firewall or VPN as the module does not support HTTPS natively.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your PLC platform (1756 vs 1769) to ensure correct module ordering\u003c\/li\u003e\n\u003cli\u003eFor applications requiring only Modbus TCP, consider MVI56-MNETC for higher connection counts\u003c\/li\u003e\n\u003cli\u003eUse RS-485 (2-wire) for multi-drop serial networks; RS-232 is limited to point-to-point\u003c\/li\u003e\n\u003cli\u003eDocument all Modbus register maps and device addresses before configuration\u003c\/li\u003e\n\u003cli\u003eConsider the 5201-MNET-MCM-WEB variant for enhanced web server capabilities\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776593748152,"sku":"5201-MNET-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5201-DFNT-MCM_2_6ce24b8b-9d4b-46e6-ae56-2f8ff89e42a9.png?v=1784182923","url":"https:\/\/www.globalpetroparts.com\/products\/5201-mnet-mcm-prosoft-modbus-tcp-ip-to-modbus-master-slave-gateway","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}