{"product_id":"5441-695-woodward-simplex-dataforth-field-terminal-module-ftm","title":"5441-695 Woodward Simplex DataForth Field Terminal Module (FTM)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 5441-695\u003c\/strong\u003e is a \u003cstrong\u003eSimplex DataForth Field Terminal Module (FTM)\u003c\/strong\u003e designed for the \u003cstrong\u003eMicroNet\u003c\/strong\u003e and \u003cstrong\u003eNetCon 5000\u003c\/strong\u003e control system families. It serves as a \u003cstrong\u003esignal conditioning and conversion interface\u003c\/strong\u003e between field sensors and the control system, converting various sensor input signals to a standardized \u003cstrong\u003e0–5 VDC input\u003c\/strong\u003e compatible with Woodward's 24\/8 Analog I\/O modules. The 5441-695 features \u003cstrong\u003e24 channels of 0–5 VDC input\u003c\/strong\u003e and \u003cstrong\u003e8 channels of 4–20 mA output\u003c\/strong\u003e, with each channel independently configurable using plug-in \u003cstrong\u003eDataForth SCM7B isolated converters\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Simplex DataForth Field Terminal Module (FTM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Woodward MicroNet \/ NetCon 5000 \/ 5441 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 24 channels, 0–5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8 channels, 4–20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion:\u003c\/strong\u003e Converts sensor signals to 0–5 VDC for 24\/8 Analog module compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-in Converters:\u003c\/strong\u003e Modified DataForth SCM7B isolated converters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Output Range:\u003c\/strong\u003e 1 to 4 V per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Powered via cable connector (no external power required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Not required — plug-and-play operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e Independent per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Two high-density analog\/digital cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Feature:\u003c\/strong\u003e Supports Simplex DataForth FTMs in place of standard 24\/8 FTMs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1000 g (1 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSupported DataForth Plug-in Converter Types\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple (K-Type):\u003c\/strong\u003e 1784-1028 (DataForth PN: SCM7B47K-1574)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD (100 Ohm, European Curve):\u003c\/strong\u003e 1784-655 (DataForth PN: SCM7B34-1459)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4–20 mA Input:\u003c\/strong\u003e 1784-659 (DataForth PN: SCM7BPT-1460)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0–5 VDC Input:\u003c\/strong\u003e 1784-657 (DataForth PN: SCM7BPT)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 Input + 8 Output Channels:\u003c\/strong\u003e High-density I\/O for comprehensive signal handling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDataForth SCM7B Technology:\u003c\/strong\u003e Industry-leading isolated signal conditioning with modified bandwidth and temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-in Modularity:\u003c\/strong\u003e Each of the 12 FTM slots accepts any SCM7B converter type for flexible configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Calibration Required:\u003c\/strong\u003e Factory-calibrated plug-in modules eliminate field calibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo External Power:\u003c\/strong\u003e Modules powered directly through cable connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Isolation:\u003c\/strong\u003e Galvanic isolation prevents ground loops and noise interference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplex Configuration:\u003c\/strong\u003e Supports non-redundant (simplex) MicroNet\/NetCon systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKnown Issue — Fuse Rating (April 2014 – June 2016)\u003c\/h3\u003e\n\u003cp\u003eDataForth FTM modules shipped from Woodward between \u003cstrong\u003eApril 2014 and June 2016\u003c\/strong\u003e may contain \u003cstrong\u003eincorrectly rated fuses\u003c\/strong\u003e. The standard fuse is \u003cstrong\u003e100 mA 250 V\u003c\/strong\u003e, but some units were shipped with \u003cstrong\u003e1.25 A 250 V fuses\u003c\/strong\u003e. While this substitution does not affect CE compliance or standard operation in CSA Class 1, Division 2 and ATEX Group II, Category 3 locations, customers using \u003cstrong\u003eCurrent Input Plug-in modules\u003c\/strong\u003e are at higher risk for transmitter damage in the event of a dead short. Woodward completed rework activities on \u003cstrong\u003eJune 15, 2016\u003c\/strong\u003e. Rework kits are available for field replacement.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine control system analog signal conditioning (temperature, pressure, flow)\u003c\/li\u003e\n\u003cli\u003eEngine management system sensor interfacing\u003c\/li\u003e\n\u003cli\u003eGenerator control panel RTD and thermocouple input processing\u003c\/li\u003e\n\u003cli\u003eIndustrial process control 4–20 mA transmitter signal conversion\u003c\/li\u003e\n\u003cli\u003eMicroNet Simplex and MicroNet Plus I\/O expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInsert module into card guides in MicroNet\/NetCon chassis\u003c\/li\u003e\n\u003cli\u003eConnect to motherboard via high-density analog\/digital cables\u003c\/li\u003e\n\u003cli\u003eSecure with two screws at top and bottom of front panel\u003c\/li\u003e\n\u003cli\u003eInstall DataForth SCM7B plug-in converters into any of the 12 FTM slots\u003c\/li\u003e\n\u003cli\u003eConnect field sensor wiring to FTM terminal blocks\u003c\/li\u003e\n\u003cli\u003eVerify signal conversion accuracy via Woodward diagnostic software\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eRemoval Procedure\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eToggle the two handles at top and bottom of the module outward\u003c\/li\u003e\n\u003cli\u003eModule will move out just far enough for boards to disengage motherboard connectors\u003c\/li\u003e\n\u003cli\u003eCarefully extract the module from chassis\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many channels does 5441-695 have?\u003c\/strong\u003e\u003cbr\u003eA: 24 input channels (0–5 VDC) and 8 output channels (4–20 mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What plug-in converters are used?\u003c\/strong\u003e\u003cbr\u003eA: Modified DataForth SCM7B isolated converters. Available types include thermocouple (K-type), RTD (100Ω), 4–20 mA input, and 0–5 VDC input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the FTM require calibration?\u003c\/strong\u003e\u003cbr\u003eA: No. The FTM and its plug-in modules do not require calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are the plug-in modules powered?\u003c\/strong\u003e\u003cbr\u003eA: They are powered directly through the cable connector — no external power connections to the FTM are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 5441-695 and 5441-697?\u003c\/strong\u003e\u003cbr\u003eA: 5441-695 is the Simplex FTM; 5441-697 is the TMR (Triple Modular Redundancy) FTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Was there a fuse issue with this module?\u003c\/strong\u003e\u003cbr\u003eA: Yes, modules shipped between April 2014 and June 2016 may have 1.25A fuses instead of the correct 100mA fuses. Verify fuse rating if your unit falls within this date range.\u003c\/p\u003e\n\n\u003ch3\u003eModel Selection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5441-695 = \u003cstrong\u003eSimplex DataForth FTM\u003c\/strong\u003e (24 in \/ 8 out) for non-redundant systems\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003eTMR redundant systems\u003c\/strong\u003e, use 5441-697 instead\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003ehigh-density discrete I\/O\u003c\/strong\u003e (24 in \/ 12 out), consider 5441-693 or 5441-694\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003erelay interface\u003c\/strong\u003e, consider 5441-413 (32 ch) or 5441-419 (16 ch)\u003c\/li\u003e\n\u003cli\u003eVerify required plug-in converter types (TC, RTD, 4–20 mA, 0–5V) before ordering\u003c\/li\u003e\n\u003cli\u003eCheck fuse rating if unit was manufactured between April 2014 and June 2016\u003c\/li\u003e\n\u003cli\u003eConfirm MicroNet\/NetCon chassis slot availability and cable compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53789938483384,"sku":"5441-695","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5441-693_3.png?v=1784278432","url":"https:\/\/www.globalpetroparts.com\/products\/5441-695-woodward-simplex-dataforth-field-terminal-module-ftm","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}