{"product_id":"5x00300g02-emerson-ovation-profibus-dp-interface-module","title":"5X00300G02 | Emerson Ovation | Profibus DP Interface Module","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 5X00300G02\u003c\/strong\u003e is a \u003cstrong\u003eProfibus DP Interface Module\u003c\/strong\u003e for the Emerson Ovation distributed control system (DCS). It enables \u003cstrong\u003ehigh-speed communication between Ovation controllers and Profibus DP field devices\u003c\/strong\u003e, supporting seamless integration of third-party I\/O, drives, and smart devices into the Ovation control architecture. Note: Some suppliers list this as an Ethernet communication or analog output module; verify exact functionality with your supplier before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 5X00300G02\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Profibus DP Interface Module (per DCSCenter official description)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Profibus DP communication interface for Ovation DCS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Profibus DP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 kg (per some suppliers); 2 kg (per others); 1.2 kg (per others)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 220 × 89 × 31 mm (per some suppliers); 173 × 100 × 42 mm (per others); 134 × 173 × 40 mm (per others)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Thailand\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson (formerly Westinghouse)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProfibus DP master\/slave interface for third-party device integration\u003c\/li\u003e\n  \u003cli\u003eHigh-speed deterministic communication with field devices\u003c\/li\u003e\n  \u003cli\u003eCompatible with Ovation DCS controller architecture\u003c\/li\u003e\n  \u003cli\u003eRugged industrial design for harsh environments\u003c\/li\u003e\n  \u003cli\u003eSupports redundant communication paths (when configured)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C (-40°F to 158°F) (per most suppliers)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the 5X00300G02 used for?\u003c\/h4\u003e\n\u003cp\u003ePer official DCSCenter documentation, it is a \u003cstrong\u003eProfibus DP Interface Module\u003c\/strong\u003e for Emerson Ovation DCS, enabling communication with Profibus DP field devices. Some suppliers list it as an Ethernet or analog module — verify exact functionality before ordering.\u003c\/p\u003e\n\n\u003ch4\u003eWhat does \"Profibus DP\" mean?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProfibus DP\u003c\/strong\u003e (Decentralized Peripherals) is a high-speed industrial fieldbus protocol for deterministic communication between controllers and distributed I\/O devices.\u003c\/p\u003e\n\n\u003ch4\u003eWhy do different suppliers list different specifications?\u003c\/h4\u003e\n\u003cp\u003eThere is significant inconsistency in supplier listings for 5X00300G02. The \u003cstrong\u003emost reliable source (DCSCenter) identifies it as a Profibus DP Interface\u003c\/strong\u003e. Other suppliers may have incorrect listings or may be referencing different regional variants.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between 5X00300G01 and 5X00300G02?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003e5X00300G01\u003c\/strong\u003e is a related module (possibly an earlier revision or different interface type). The \u003cstrong\u003e5X00300G02\u003c\/strong\u003e is the Profibus DP interface variant. Consult Emerson for specific differences.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003ch4\u003eSafety Precautions\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-energize the Ovation rack before installation\u003c\/li\u003e\n  \u003cli\u003eUse proper ESD protection when handling the module\u003c\/li\u003e\n  \u003cli\u003eVerify Profibus DP cable specification and termination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStep-by-Step Procedure\u003c\/h4\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the Ovation I\/O rack\u003c\/li\u003e\n  \u003cli\u003eAlign the module with the rack slot and insert firmly\u003c\/li\u003e\n  \u003cli\u003eSecure the module retaining clips\u003c\/li\u003e\n  \u003cli\u003eConnect Profibus DP cable to the module connector\u003c\/li\u003e\n  \u003cli\u003eEnsure proper bus termination at network ends\u003c\/li\u003e\n  \u003cli\u003ePower up and verify module status LEDs\u003c\/li\u003e\n  \u003cli\u003eConfigure Profibus DP network via Ovation engineering station\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCritical:\u003c\/strong\u003e Verify exact module functionality (Profibus DP vs Ethernet vs Analog) with your supplier before ordering\u003c\/li\u003e\n  \u003cli\u003eConfirm Profibus DP device compatibility and baud rate requirements\u003c\/li\u003e\n  \u003cli\u003eEnsure proper bus termination for reliable communication\u003c\/li\u003e\n  \u003cli\u003eFor new projects, consider current-generation Ovation communication modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5X00300G01 — Related interface module (earlier revision or variant)\u003c\/li\u003e\n  \u003cli\u003e5X00300G02 — Profibus DP Interface Module (this part, per DCSCenter)\u003c\/li\u003e\n  \u003cli\u003e5X00321G01 — Profibus DP Interface PMOD\u003c\/li\u003e\n  \u003cli\u003e5X00419G02 — Ethernet Link Controller with Time Stamp\u003c\/li\u003e\n  \u003cli\u003e5X00583G01 — Communication module for heterogeneous systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53712736616632,"sku":"5X00300G02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5X00481G01_2.png?v=1782979612","url":"https:\/\/www.globalpetroparts.com\/products\/5x00300g02-emerson-ovation-profibus-dp-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}