{"product_id":"5x00321g01-westinghouse-ovation-profibus-dp-interface-module","title":"5X00321G01 | Westinghouse Ovation Profibus DP Interface Module","description":"\u003ch3\u003eEmerson Ovation 5X00321G01 – Profibus DP Interface Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 5X00321G01\u003c\/strong\u003e is a \u003cstrong\u003eProfibus DP communication interface module\u003c\/strong\u003e that bridges the Ovation DCS with Profibus DP fieldbus networks. It integrates Profibus-compatible devices including motor starters, remote I\/O, and smart instruments into the Ovation control architecture.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Profibus DP Interface \/ Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Profibus DP (Decentralized Peripherals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e 12 Mbps (automatic baud rate detection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC, backplane or local\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 118 mm × 28 mm × 93 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard Ovation I\/O rack or DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Diagnostic LEDs and software status registers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports redundant Profibus DP networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5X00321G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProfibus DP Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eProfibus DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 × 28 × 93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eOvation rack \/ DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED plus software status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfibus DP Versions\u003c\/strong\u003e\u003cbr\u003eThe module supports Profibus DP-V0 and DP-V1, covering cyclic data exchange and acyclic parameterization for industrial devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfibus Slave Capacity\u003c\/strong\u003e\u003cbr\u003eOne Profibus segment supports 126 addresses. Typical Ovation configurations manage 32–64 slaves per interface, limited by network topology and repeaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens ET200 Compatibility\u003c\/strong\u003e\u003cbr\u003eAny Profibus DP-certified slave device is compatible, including Siemens ET200, ABB CI541, and Pepperl+Fuchs remote I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003cbr\u003eDual 5X00321G01 modules configure for redundant Profibus DP communication with automatic failover.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Install 5X00321G01 into the Ovation communication slot or DIN rail carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Connect Profibus DP cable to the 9-pin D-Sub connector. Pin 3 = B-line (red), Pin 8 = A-line (green), shield to chassis ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e Activate termination resistors at both ends of the Profibus segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e In Ovation Developer Studio, add the Profibus DP network. Import the GSD file for each slave device and map I\/O data to controller tags.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Commission the network. Verify all slaves reach Data_Exchange state. Check diagnostic counters for timeouts or frame errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cp\u003eSelect \u003cstrong\u003e5X00321G01\u003c\/strong\u003e when integrating \u003cstrong\u003eProfibus DP devices\u003c\/strong\u003e into Ovation. For Profinet, Ethernet\/IP, or Modbus TCP devices, use the Ovation Ethernet link module (5X00419G02). For Modbus RTU serial devices, use 1C31166G01 or 1C31166G02 serial link controllers. Verify GSD file availability from device vendors before committing to Profibus DP architecture.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53864848294072,"sku":"5X00321G01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5X00321G01.png?v=1785815227","url":"https:\/\/www.globalpetroparts.com\/products\/5x00321g01-westinghouse-ovation-profibus-dp-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}