{"product_id":"81001-717-01-r-allen-bradley-rfi-emi-shielding-fiberglass-filter","title":"81001-717-01-R | Allen Bradley | RFI\/EMI Shielding Fiberglass Filter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 81001-717-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a specialized industrial filtration component designed for high-density electrical enclosures. This 432x795mm fiberglass module performs a dual-role: it captures airborne particulates while providing essential attenuation for Radio Frequency Interference (RFI) and Electromagnetic Interference (EMI). We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Original\u003c\/strong\u003e, ensuring your control system maintains environmental integrity and electromagnetic compliance in high-noise manufacturing zones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 81001-717-01-R utilizes reinforced fiberglass media to balance airflow efficiency with shielding capabilities:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e81001-717-01-R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade Fiberglass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e432 x 795 mm (approx. 17 x 31.3 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRFI\/EFI\/EMI Noise Suppression \u0026amp; Air Filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Accessories \/ Noise Filters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.00 lbs (1.36 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Cabinets, Drive Enclosures, Control Rooms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Phase Interference Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis filter incorporates specialized fiberglass density to disrupt RFI and EMI pathways. It prevents high-frequency noise from entering or exiting the cabinet, protecting sensitive PLC logic and analog signals from erratic behavior caused by nearby high-power drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Particulate Capture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe deep-bed fiberglass construction traps fine dust and industrial contaminants. This prevents the buildup of conductive debris on internal circuit boards, which otherwise leads to short circuits and thermal hotspots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Pressure Drop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 432x795mm surface area maintains a low static pressure drop. This engineering choice allows cooling fans to move maximum air volume, ensuring internal power components stay within their rated operating temperature ranges during continuous duty cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical and Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe fiberglass media resists degradation from common industrial vapors and high cabinet temperatures. This durability ensures the filter maintains its structural shape and shielding effectiveness throughout its entire service interval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Enclosure Fit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe exact 432x795mm dimensions ensure a tight seal within standard Allen Bradley panel intake frames. This precise fit eliminates \"air bypass,\" forcing all incoming air through the filtration and shielding media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this 81001-717-01-R filter 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this product arrives in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition in its original factory packaging. Each filter retains its full structural rigidity and shielding properties, as used or cleaned filters often suffer from compromised fiberglass density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this filter require a specific mounting orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Always install the 81001-717-01-R with the airflow direction indicated on the frame. Installing the filter backwards can increase airflow resistance and reduce the effectiveness of the EMI shielding layer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace this RFI\/EMI filter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplacement frequency depends on your facility's air quality. However, maintenance teams typically replace these filters during scheduled 6-month or 12-month PM (Preventative Maintenance) cycles to ensure optimal cooling and noise suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this filter be washed and reused?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe do not recommend washing fiberglass RFI\/EMI filters. Water or compressed air can damage the specialized fibers and the conductive coatings required for noise suppression, which may result in a loss of EMI shielding effectiveness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53453090259128,"sku":"81001-717-01-R","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/81001-717-01-R1.jpg?v=1778485545","url":"https:\/\/www.globalpetroparts.com\/products\/81001-717-01-r-allen-bradley-rfi-emi-shielding-fiberglass-filter","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}