{"product_id":"8c-paiha1-51454470-275-honeywell-hart-analog-input-module","title":"8C-PAIHA1 51454470-275 Honeywell HART Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAIHA1 (P\/N: 51454470-275)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART-enabled analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It provides reliable signal acquisition for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 analog input channels\u003c\/strong\u003e, acting as the interface between precision field instruments and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controller\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSupporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART protocol pass-through\u003c\/strong\u003e, the module enables access to secondary variables and diagnostic data from smart transmitters, allowing enhanced asset management without additional wiring. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density Series 8 form factor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes cabinet space requirements while maintaining strong\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation and noise immunity\u003c\/strong\u003e, making it suitable for continuous operation in demanding process environments.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e8C-PAIHA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454470-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eHART 5 \/ 6 \/ 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 8 Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eCompact Series 8 Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 × 12.7 × 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eHigh-availability process control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Context\u003c\/h2\u003e\n\u003cp\u003eThe 8C-PAIHA1 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-critical and high-uptime operations\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical and refinery facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffshore oil \u0026amp; gas platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale power generation plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHART integration enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote device diagnostics, calibration checks, and health monitoring\u003c\/strong\u003e, reducing maintenance effort and unplanned downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 8C-PAIHA1 support redundancy?\u003c\/strong\u003e\u003cbr\u003eA: Yes. When used with the appropriate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant termination assembly\u003c\/strong\u003e, the module can be installed in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain operation during a hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main advantage of HART functionality?\u003c\/strong\u003e\u003cbr\u003eA: HART allows access to device-specific diagnostics and secondary variables—such as internal sensor status and temperature—that are not available through a standard 4–20 mA signal alone.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52511086313656,"sku":"8C-PAIHA1 51454470-275","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/8C-PAIHA1_51454470-275.jpg?v=1769670775","url":"https:\/\/www.globalpetroparts.com\/products\/8c-paiha1-51454470-275-honeywell-hart-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}