{"product_id":"8c-pain01-honeywell-analog-input-module","title":"8C-PAIN01 Honeywell Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAIN01 (Spare P\/N: 51454356-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edifferential analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision signal acquisition\u003c\/strong\u003e, featuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000 VDC optical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto safeguard control logic from field-side electrical surges and ground loops.\u003c\/p\u003e\n\u003cp\u003eUnlike standard single-ended input modules, the 8C-PAIN01 employs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-impedance differential voltage inputs\u003c\/strong\u003e, providing excellent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommon-mode noise rejection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein electrically noisy industrial environments. It supports a wide variety of signal types, including bi-directional current and standard voltage loops, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex process monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industries such as power generation and refining.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart \/ Spare Number\u003c\/td\u003e\n\u003ctd\u003e51454356-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh-impedance differential voltage, optically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1000 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Input Ranges\u003c\/td\u003e\n\u003ctd\u003e−40 to +40 mA, 0–20 mA, 0–10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB @ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e120% (2 s) \/ 150% (0.1 s) of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e5.1 × 26.7 × 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Context\u003c\/h2\u003e\n\u003cp\u003eThe 8C-PAIN01 is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eapplications where signal integrity is critical\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring high-voltage battery arrays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring small voltage drops across shunt resistors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision analog loops in power plants and refineries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000 V isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that even in the event of a field-side fault, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controller remains protected\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the differential input on the 8C-PAIN01?\u003c\/strong\u003e\u003cbr\u003eA: The differential design measures the voltage difference between two points while rejecting common-mode voltage, greatly reducing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMI and noise errors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 8C-PAIN01 support 4–20 mA loops?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module can be configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e−40 to +40 mA\u003c\/strong\u003e, covering standard industrial 4–20 mA instrumentation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52511100272824,"sku":"8C-PAIN01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/8C-PAIN011.jpg?v=1769670775","url":"https:\/\/www.globalpetroparts.com\/products\/8c-pain01-honeywell-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}