{"product_id":"900b01-0001-honeywell-analog-output-module","title":"900B01-0001 Honeywell Analog Output Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B01-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance, isolated analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell HC900 Control System\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour independent channels\u003c\/strong\u003e, enabling precise control of field devices such as actuators, control valves, and Variable Frequency Drives (VFDs). With robust isolation and flexible signal options, this module is ideal for deterministic process control in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eEach channel is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanically isolated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the backplane and other channels, protecting the controller logic from ground loops and electrical interference. Its wide operating temperature and humidity ranges ensure reliable performance in both indoor control rooms and harsh remote process enclosures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900B01-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell HC900 Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Isolated Analog Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, 0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Backplane Powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 mA per channel (internal logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field and logic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.8 cm x 7.8 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.72 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulating Valve Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivering precise 4–20 mA signals to actuators in steam or liquid flow loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Speed Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlling pump or fan speeds via VFDs using 0–10 V signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging industrial dampers and heating elements in large-scale facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulating fuel-to-air ratios through analog actuator positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 900B01-0001 support current (4–20 mA) output?\u003c\/strong\u003e\u003cbr\u003eYes. It supports both current loops (4–20 mA, 0–20 mA) and voltage outputs (0–10 VDC), making it a universal analog output module for the HC900.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal block is required for this module?\u003c\/strong\u003e\u003cbr\u003eThe module typically uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20-terminal block (Part Number 900TE1-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field wiring. This is usually ordered separately or as part of an I\/O kit.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52521149825208,"sku":"900B01-0001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900B01-00011_505185a4-3340-4215-8306-96d9c234ce43.jpg?v=1770017080","url":"https:\/\/www.globalpetroparts.com\/products\/900b01-0001-honeywell-analog-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}