{"product_id":"9905-463-woodward-protech-gii-de-energize-to-trip-safety-unit","title":"9905-463 Woodward | ProTech-GII De-Energize-to-Trip Safety Unit","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 9905-463 ProTech-GII TMR Digital Overspeed Protection Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-463 (Model: 9905-463)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity safety instrument designed for the absolute protection of critical rotating machinery. As a core component of the Woodward ProTech-GII series, this module provides independent, ultra-high-speed overspeed detection for gas, steam, and hydro turbines. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-463 (Part Number: 9905-463)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis architected with Triple Modular Redundancy (TMR), utilizing three completely independent CPUs and speed signal paths to eliminate single points of failure.\u003c\/p\u003e\n\u003cp\u003eThis specific version is configured for De-Energize-to-Trip (DET) operation. In this fail-safe mode, the internal safety relays remain energized during normal turbine operation. Should the system detect an overspeed condition, a hardware fault, or a total loss of control power, the relays instantly de-energize to trigger an emergency shutdown. With a deterministic hardware-based response time of less than 12 milliseconds, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-463 (9905-463)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures compliance with the most stringent industrial safety standards in power generation and petrochemical sectors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-463 (Part Number: 9905-463)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates redundant speed sensing with high-resolution digital logic.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e9905-463\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProTech-GII Overspeed Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Modular Redundant (TMR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoting Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-out-of-3 (2oo3) Hardware-based Voting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTrip Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDe-Energize-to-Trip (DET) \/ Fail-Safe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 12 ms (Total response from detection to relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Redundant inputs supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Independent Magnetic Pickups (MPUs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Form-A \/ Form-C Safety Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU (RS-485) \/ Modbus TCP (Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Industrial Metal Enclosure)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.59 kg (3.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52519425278136,"sku":"9905-463","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/125..jpg?v=1769997599","url":"https:\/\/www.globalpetroparts.com\/products\/9905-463-woodward-protech-gii-de-energize-to-trip-safety-unit","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}