{"product_id":"aai143-h50-a4s00-yokogawa-centum-vp-16-channel-hart-analog-input-module","title":"AAI143-H50\/A4S00 | Yokogawa CENTUM VP 16-Channel HART Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI143-H50\/A4S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density, isolated analog input interface for the CENTUM VP Distributed Control System (DCS). This module captures 4 to 20 mA signals from 16 independent channels, enabling precise process monitoring for mission-critical loops. By integrating the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART protocol\u003c\/strong\u003e, it facilitates bidirectional digital communication, allowing the DCS to extract device diagnostics and secondary variables from smart field instruments. This configuration includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/A4S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption, featuring a factory-integrated Pressure Clamp Terminal Block (Model ATA4S-00). We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe AAI143-H50\/A4S00 utilizes a specific suffix and option logic to define its communication and termination capabilities:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAAI143\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 16-Channel Analog Input Module (4-20 mA, Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication: Supports Integrated HART Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy: Supports dual-redundant configuration with standard switch-over\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration: Basic type hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/A4S00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTermination: Includes Pressure Clamp Terminal Block (Model ATA4S-00)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AAI143-H50\/A4S00 delivers high-performance data acquisition and robust signal integrity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16, fully isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHART Protocol (Superimposed on analog signal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure Clamp (Screwless) via ATA4S-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Update Period:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC between input and system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(Typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AAI143-H50\/A4S00 addresses specific industrial deployment challenges through its hybrid termination and communication design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Screwless Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/A4S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epressure clamp terminal block eliminates the need for manual screw tightening. Technicians insert wires directly to establish a gas-tight, vibration-resistant connection. This reduces installation labor by 50% and prevents signal loss in high-vibration environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Device Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated HART support removes the requirement for external HART multiplexers. The DCS captures diagnostic alerts—such as sensor drift or transmitter failure—directly from the field, facilitating a transition from reactive to predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull galvanic isolation between the 16 channels prevents ground loop currents from corrupting process data. This architecture ensures that an electrical fault on a single transmitter remains contained, protecting the central DCS backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"Suffix 5\" designation ensures the module supports dual-redundant configurations. In the event of a hardware failure, the system executes an instantaneous switch-over to the standby module, maintaining continuous process visibility without signal bumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \/A4S00 Pressure Clamp over standard terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/A4S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block maintains constant spring tension on the wire. Unlike traditional screw terminals that can loosen due to thermal cycling or mechanical vibration, the pressure clamp ensures a permanent, maintenance-free electrical contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the AAI143-H50\/A4S00 with non-HART transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module functions as a high-precision standard 4-20 mA analog input module for conventional devices. The HART communication features remain available for use whenever you upgrade to smart field instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module supply power to 2-wire transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When integrated into the CENTUM VP I\/O nest, the module distributes the necessary loop power to 2-wire transmitters while simultaneously capturing the 4-20 mA signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs any special software required to use the HART features?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the hardware natively supports HART signals, you must enable HART communication within the Yokogawa System View configuration to pass digital diagnostics to your Asset Management System (AMS).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53297063395512,"sku":"AAI143-H50\/A4S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AAI841-S002_e9394dbd-0746-4ed2-9e50-173496f46858.jpg?v=1776159248","url":"https:\/\/www.globalpetroparts.com\/products\/aai143-h50-a4s00-yokogawa-centum-vp-16-channel-hart-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}