{"product_id":"abb-07kt92-gjr5250500r0262-07-kt-92-central-processing-unit","title":"ABB 07KT92 GJR5250500R0262\/07 KT 92 Central Processing Unit","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT92 (GJR5250500R0262)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a self-contained central processing unit for ABB’s Procontic and Procontic CS31 distributed control systems, part of the legacy 90 Series architecture. Unlike rack-based PLCs, this module integrates CPU, memory, digital\/analog I\/O, and communication interfaces into a single compact housing—ideal for standalone or small-scale process control applications.\u003c\/p\u003e\n\u003cp\u003eIt executes logic programs stored in 14 KB of FLASH EPROM and supports real-time monitoring and control via its onboard I\/O. Communication is handled through dual RS-232 ports (user-configurable for programming or HMI) and an RS-485 system bus for connecting remote I\/O or operator panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT92 (GJR5250500R0262)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: ABB Procontic, Procontic CS31 (90 Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCPU Memory\u003c\/strong\u003e: 14 KB FLASH EPROM (non-volatile program storage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e: 12 channels, 24 VDC, opto-isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e: 8 transistor outputs, 24 VDC, 0.5 A per channel (sinking)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e: 4 channels, ±10 V or 0–20 mA (software-selectable), 12-bit resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e: 2 channels, 0–20 mA or 4–20 mA, 12-bit resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 × RS-232 (configurable baud rate, protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × RS-485 (system bus for I\/O expansion or peer-to-peer links)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC ±10%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 254 mm (L) × 102 mm (W) × 152 mm (H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.7 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLocal control of pumps, valves, and tanks in water\/wastewater plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall boiler or burner management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandalone machinery control where minimal footprint is critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ: Can this CPU be expanded with additional I\/O?\u003c\/strong\u003e\u003cbr\u003eA: Yes—via the RS-485 system bus, it supports connection to remote I\/O modules within the Procontic CS31 family.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is programming software still available?\u003c\/strong\u003e\u003cbr\u003eA: ABB’s original PG5 or PCS tools are required. While no longer sold new, licensed copies and migration services are available through authorized support channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it differ from the 07KT98?\u003c\/strong\u003e\u003cbr\u003eA: The 07KT92 is for Procontic CS31 and includes integrated I\/O; the 07KT98 is a CPU-only unit for the Advant OCS platform with no local I\/O.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52513664434360,"sku":"07KT92 GJR5250500R0262","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/07KT98_332fcda6-5458-4ef7-8dfe-aaf6ffbcf7e9.jpg?v=1769771135","url":"https:\/\/www.globalpetroparts.com\/products\/abb-07kt92-gjr5250500r0262-07-kt-92-central-processing-unit","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}