{"product_id":"abb-ai830a-3bse040662r1-s800-i-o-analog-input-module","title":"ABB AI830A 3BSE040662R1 S800 I\/O Analog Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AI830A (3BSE040662R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog input interface within the S800 I\/O system. This module specifically handles resistance temperature detectors (RTD) and resistive potentiometers. It provides eight independent channels for precise temperature monitoring in complex industrial environments. By integrating this module, operators gain reliable data acquisition capabilities for critical thermal processes, ensuring system stability and safety. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe AI830A delivers robust performance through the following technical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-wire RTD: Pt100, Cu10, Ni100, Ni120; Potentiometer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Cycle Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 + 95 * (number of active channels) ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGroupwise isolated from ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.6 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCMRR (50\/60Hz)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;120 dB (at 10Ω load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 °C (+32 to +131 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04: G3 (Harsh Environment Rated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a Common Mode Rejection Ratio (CMRR) of over 120 dB. This ensures signal integrity even in high-interference environments where electromagnetic noise typically degrades sensor accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith G3-level corrosion protection according to ISA-S71.04, the AI830A withstands atmospheric contaminants found in chemical plants and refineries. It maintains long-term operational life where standard modules often fail due to oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-mounted LEDs provide instant visual feedback (Fault, Run, Warning). The module internal logic constantly supervises for open-circuits, short-circuits, and power supply irregularities, significantly reducing troubleshooting downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Marine Application:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtensive marine certifications (ABS, BV, DNV, LR) allow for seamless integration into maritime and offshore automation systems, meeting strict vibration and environmental standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AI830A support 2-wire or 4-wire RTD configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module specifically supports 3-wire RTD configurations. The 3-wire setup provides an excellent balance by compensating for lead wire resistance, ensuring higher accuracy than 2-wire systems without the complexity of 4-wire wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a channel experiences a short circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module's built-in supervision detects short-circuit and open-circuit conditions immediately. It triggers a \"Channel Error\" status and activates the \"F\" (Fault) or \"W\" (Warning) LED on the front panel to alert maintenance personnel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module in hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The AI830A carries ATEX Zone 2 and Class 1 Division 2 certifications, making it suitable for installation in areas where explosive gases may occasionally be present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the update cycle time vary?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module calculates the update cycle based on active channels (\u003cspan class=\"math-inline\"\u003e$150 + 95 \\times n$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ems). To optimize system responsiveness, you can disable unused channels within the control software to decrease the overall cycle time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53172561772728,"sku":"AI830A 3BSE040662R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AI830A.jpg?v=1774835508","url":"https:\/\/www.globalpetroparts.com\/products\/abb-ai830a-3bse040662r1-s800-i-o-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}