{"product_id":"abb-ci830-3bse013252r1-s800-i-o-profibus-dp-v0-communication-interface","title":"ABB CI830 3BSE013252R1 S800 I\/O PROFIBUS DP-V0 Communication Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI830 (3BSE013252R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Fieldbus Communication Interface (FCI) for the S800 I\/O system. This module enables a cluster of S800 I\/O modules to communicate with a master controller over a PROFIBUS DP-V0 network. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the deterministic bridge required to translate field data into standard PROFIBUS protocols. It serves as the primary head station for remote I\/O clusters, managing both the ModuleBus communication and the external fieldbus link.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe CI830 utilizes standardized PROFIBUS protocols to integrate S800 I\/O into diverse control architectures:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI830 \/ 3BSE013252R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP-V0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 12 Mbit\/s (Autobaud)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 24 S800 Modules (with Optical Extension)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e58.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC (19.2 - 30V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic isolation to PROFIBUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Multi-Vendor Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI830 utilizes the industry-standard PROFIBUS DP-V0 protocol. This allows engineers to connect S800 I\/O clusters not only to ABB AC 800M controllers but also to third-party PLCs and DCS systems, protecting existing hardware investments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Deterministic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports baud rates up to 12 Mbit\/s with automatic baud rate detection. This ensures rapid data throughput and low-latency updates for time-critical process loops across the distributed network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Cluster Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single CI830 manages up to 12 I\/O modules on a single electrical ModuleBus. By utilizing optical Modulebus ports, you can extend this capacity to 24 modules, allowing for massive I\/O density from a single network node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Hardware Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features galvanic isolation between the PROFIBUS DP interface and the internal electronics. This barrier prevents ground loops and transient voltage spikes on the fieldbus from damaging the I\/O cluster or the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-facing LED indicators provide instant visual feedback on power status, module faults, and network activity. This transparency allows technicians to identify communication bottlenecks or hardware failures without specialized diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CI830 support PROFIBUS DP-V1 features?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CI830 specifically supports the DP-V0 cyclic data exchange protocol. If your application requires acyclic communication (DP-V1) for HART pass-through or advanced device management, we recommend the CI840 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the PROFIBUS station address on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI830 features two rotary switches on the front panel. You use these to manually set the station address (01-99) before powering up the module and connecting it to the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or used unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely not. We guarantee this CI830 (3BSE013252R1) is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware. It arrives in the original ABB factory-sealed packaging with all security labels and technical documentation intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CI830 require a specific baseplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must mount the CI830 on a compatible Module Termination Unit (MTU) such as the TU810, TU812, or TU814. The MTU provides the physical connections for the 24V DC power and the PROFIBUS DP cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53096057700536,"sku":"CI830 3BSE013252R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CI8303BSE013252R1.jpg?v=1774430786","url":"https:\/\/www.globalpetroparts.com\/products\/abb-ci830-3bse013252r1-s800-i-o-profibus-dp-v0-communication-interface","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}