{"product_id":"abb-ci857-3bse018144r1-system-800xa-insum-communication-interface-副本","title":"CI853 3BSE018103R1 | ABB | System 800xA Dual RS-232 Communication Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI853 (3BSE018103R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance, dual-channel RS-232 communication interface for the AC 800M controller family. This module enables seamless point-to-point connectivity with third-party devices using COMLI or MODBUS RTU protocols. By mounting directly to the CEX-Bus, the CI853 expands the controller's peripheral reach to include modems, printers, and legacy PLC systems. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new original equipment\u003c\/strong\u003e, ensuring full technical compliance for your mission-critical automation infrastructure.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe CI853 provides two independent serial channels within a compact, DIN-rail mountable form factor.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BSE018103R1 (CI853K01)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCOMLI, MODBUS RTU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 x RS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 bps to 19,200 bps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaster or Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ-45 female (8-pin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to +55 °C (+32 to +131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eG3 compliant (ISA 71.04)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarine Certificates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABS, BV, DNV-GL, LR\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e59 mm (W) x 185 mm (H) x 127.5 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e700 g (including base)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Connectivity Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI853 features two independent channels in a single 59 mm wide module. This high-density design optimizes cabinet space while providing versatile communication paths for varied serial peripherals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Integrity System Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis interface works directly with High Integrity (HI) Controllers. This allows engineers to implement non-interfering serial communications within safety-critical environments without compromising system SIL ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects the internal circuitry against atmospheric pollutants and corrosive gases. This feature ensures long-term hardware availability in demanding sectors like oil and gas or chemical processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance with Hot Swap:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHot Swap\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctionality. Technicians replace the module while the system remains energized, significantly reducing Mean Time to Repair (MTTR) and avoiding costly process interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Maritime Approval:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComprehensive marine certifications (ABS, DNV-GL, etc.) qualify this module for offshore platforms and vessel automation, where vibration and humidity requirements exceed standard industrial specs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CI853 act as both a Master and a Slave?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The CI853 supports both Master and Slave configurations for COMLI and MODBUS RTU protocols, providing maximum flexibility when integrating with third-party SCADA or PLC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type does the RJ-45 port require for RS-232?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit utilizes an 8-pin RJ-45 connector for serial signals. You must use specifically pinned adapters or cables to convert the RJ-45 interface to standard DB9 or DB25 connectors required by your field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this kit include the baseplate?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The 3BSE018103R1 (CI853K01) designation identifies the complete kit, which includes the CI853 communication module and the necessary TP853 baseplate for CEX-Bus mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine, factory-sealed ABB unit?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. We guarantee that this CI853 3BSE018103R1 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware. It ships in factory packaging with all security seals and documentation intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53098122248376,"sku":"CI853 3BSE018103R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CI8303BSE013252R12_d27a96df-0d2f-4710-9c15-f8c1c016e81a.jpg?v=1774492813","url":"https:\/\/www.globalpetroparts.com\/products\/abb-ci857-3bse018144r1-system-800xa-insum-communication-interface-%e5%89%af%e6%9c%ac","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}