{"product_id":"abb-ci857-3bse018144r1-system-800xa-insum-communication-interface","title":"ABB CI857 3BSE018144R1 System 800xA INSUM Communication Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI857 (3BSE018144R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the dedicated Master interface for ABB’s INSUM (Integrated System for User-optimized Motor control) within the System 800xA architecture. This module enables AC 800M controllers to integrate seamlessly with intelligent Motor Control Centers (MCC), providing real-time supervision and control over motor starters and switchgear. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new original equipment\u003c\/strong\u003e, ensuring full technical compliance with G3 harsh environment standards for mission-critical industrial applications.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe CI857 utilizes a high-speed CEX-Bus connection to provide deterministic data throughput between the controller and the INSUM network.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArticle Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE018144R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB's INSUM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRole\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaster\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ-45 female (8-pin)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHI Controller Compatible\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Units on CEX Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical 24V Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 compliant (ISA 71.04)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e700 g (1.5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI857 works directly with High Integrity (HI) Controllers. This allows engineers to implement complex motor control strategies within safety-instrumented systems without compromising SIL ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Resistance in Harsh Zones:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects the internal circuitry against atmospheric pollutants. This solves the common industrial pain point of hardware failure in wastewater treatment or chemical processing plants where corrosive gases often degrade standard electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient System Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHot Swap\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctionality. Technicians replace units while the controller remains energized, significantly reducing Mean Time to Repair (MTTR) and preventing unnecessary process shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact CEX-Bus Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a narrow width of only 59 mm, the CI857 maximizes rail space. This compact design allows for the installation of up to 6 units on a single CEX-bus, facilitating large-scale motor networking in restricted cabinet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the CI857 with non-INSUM Ethernet protocols?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CI857 specifically runs ABB's proprietary INSUM protocol to communicate with intelligent motor starters. For standard Ethernet or Modbus TCP applications, you must select the appropriate CI-series module (e.g., CI867).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CI857 support redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific module does not support line or module redundancy. For applications requiring high-availability communication, ensure your network topology accounts for the single-master nature of the CI857.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine, factory-sealed ABB part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this CI857 3BSE018144R1 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand arrives in original ABB packaging. We do not sell refurbished or \"new-surplus\" units with compromised service lives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type does the RJ-45 port require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes standard 8-pin RJ-45 connectors. For optimal performance and noise immunity, especially in G3 environments, use high-quality shielded twisted pair (STP) cables compliant with ABB's INSUM installation guidelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53098112319672,"sku":"CI857 3BSE018144R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CI8303BSE013252R12_eca0cd4f-992c-41e3-aeec-9bbe9b11fffd.jpg?v=1774492627","url":"https:\/\/www.globalpetroparts.com\/products\/abb-ci857-3bse018144r1-system-800xa-insum-communication-interface","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}