{"product_id":"abb-dai02-dai-02-h-b-freelance-2000-analog-input-module","title":"ABB DAI02 DAI 02 H\u0026B Freelance 2000 Analog Input Module","description":"\u003ch3\u003eABB DAI02 – 16-Channel Analog Input Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DAI02\u003c\/strong\u003e is a \u003cstrong\u003e16-channel analog input module\u003c\/strong\u003e designed for the ABB Freelance 2000 distributed control system. It acquires 0–10 VDC voltage signals from field sensors and transmits digital data to the controller for process monitoring and control.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 analog input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 0–10 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e ABB Freelance 2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersion:\u003c\/strong\u003e V3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 25 mm × 25 mm × 25 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eDAI02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eABB Freelance 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25 × 25 × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003cbr\u003eThe DAI02 accepts 0–10 VDC voltage signals. It does not accept 4–20 mA current signals. Use DAI01 for 4–20 mA inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003cbr\u003eThis module is designed exclusively for the ABB Freelance 2000 DCS platform. It is not compatible with AC500 or AC800M systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Density\u003c\/strong\u003e\u003cbr\u003eThe module provides 16 analog input channels in a single slot, maximizing I\/O density for voltage monitoring applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e\u003cbr\u003eThe module delivers standard analog input resolution suitable for process monitoring and control within the Freelance 2000 architecture.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Power down the Freelance 2000 I\/O rack. Verify all field devices are de-energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Insert the DAI02 module into the designated analog input slot. Press firmly until the retention clips engage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e Connect field sensor signal wires to the module terminals. Connect signal + to channel + and signal − to channel −.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e In the Freelance 2000 engineering station, assign channel tags and configure 0–10 V scaling for each input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Verify each channel reading against a calibrated voltage source. Confirm 0 V reads 0% and 10 V reads 100% of scaled range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cp\u003eChoose \u003cstrong\u003eDAI02\u003c\/strong\u003e for \u003cstrong\u003e16-channel 0–10 VDC analog input\u003c\/strong\u003e in Freelance 2000 systems. For 4–20 mA current inputs, select DAI01. For HART-enabled analog inputs, select DAI03. For RTD and thermocouple inputs, select DAI04.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53864900001976,"sku":"DAI02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DAI02_2.png?v=1786081750","url":"https:\/\/www.globalpetroparts.com\/products\/abb-dai02-dai-02-h-b-freelance-2000-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}