{"product_id":"abb-di814-3bur001454r1-s800-i-o-digital-input-module","title":"ABB DI814 3BUR001454R1 S800 I\/O Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB DI814 (3BUR001454R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density digital interface within the S800 I\/O family. This module manages 16 independent channels and utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent sourcing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal type to interface with field devices such as switches, pushbuttons, and proximity sensors. It converts 24V DC field signals into logic data for the controller, enabling precise monitoring of discrete process states. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control architecture benefits from the latest factory specifications and maximum reliability.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe DI814 provides robust data acquisition through the following technical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (2 groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V d.c.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Sourcing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range \"0\"\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 5 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range \"1\"\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 to 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFilter Times (Selectable)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2, 4, 8, 16 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 meters (656 yards)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGroupwise isolated from ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp. 1.8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModulebus Current (+5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Group Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module architecture divides the 16 channels into two distinct groups of eight. This design isolates electrical faults within one group, preventing a localized wiring surge or ground fault from compromising the entire module’s operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelectable digital filter times (ranging from 2ms to 16ms) allow engineers to eliminate contact bounce and high-frequency EMI. This ensures the controller receives clean, debounced signals even in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Thermal Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA typical power dissipation of only 1.8 W minimizes heat buildup within the I\/O cabinet. This efficiency allows for higher packing density on the DIN rail and reduces the cooling requirements for the overall enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front-facing LED array displays the status of all 16 channels simultaneously alongside Fault (F), Run (R), and Warning (W) indicators. This visual feedback accelerates field loop-checks and pinpoints hardware issues without the need for external diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtensive Field Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports field cable lengths up to 600 meters. This capability allows for the direct connection of remote sensors in large-scale facilities, eliminating the need for intermediate junction boxes or signal amplifiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between DI814 and current sinking modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DI814 utilizes a current sourcing configuration. In this setup, the module provides the current to the field device. When the field contact closes, the current flows into the module input to register a logic \"1\". This differs from sinking modules where the field device must provide the current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle process voltage failures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DI814 performs continuous supervision of the process voltage for each group. If the voltage drops below operational thresholds, the module triggers a Warning or Error status and illuminates the corresponding front LED to alert the operator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DI814 protect sensors from overcurrent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module handles the logic, the specific Module Termination Unit (MTU) paired with the DI814 often provides current limiting for sensor power. Always verify your MTU selection to ensure integrated fuse protection for your field circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for safety-critical (SIL) applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The DI814 is a standard digital input module. For High Integrity or Safety Instrumented Systems (SIS), you must select the \"HI\" designated modules within the S800 range that meet specific SIL certification requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53172609089720,"sku":"DI814 3BUR001454R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DI814.jpg?v=1774839752","url":"https:\/\/www.globalpetroparts.com\/products\/abb-di814-3bur001454r1-s800-i-o-digital-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}