{"product_id":"abb-tpm810-800-series-turbine-protection-module","title":"ABB TPM810 800 Series Turbine Protection Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TPM810\u003c\/strong\u003e is the \u003cstrong\u003eTurbine Protection Module\u003c\/strong\u003e (Application Module) of the ABB \u003cstrong\u003e800 Series S+ Turbine\u003c\/strong\u003e protection system. It works in conjunction with the \u003cstrong\u003eCPM810 Common Processor Module\u003c\/strong\u003e and \u003cstrong\u003eTBU810 Terminal Base Unit\u003c\/strong\u003e to form the complete \u003cstrong\u003eTP800 Turbine Protection Module\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e TPM810\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 800 Series Turbine Protection Module (Application Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e Symphony Plus S+ Turbine \/ System 800xA \/ Profibus-capable DCS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Field I\/O signal conditioning and digitization for turbine protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly:\u003c\/strong\u003e Plugs into TBU810 Terminal Base Unit together with CPM810\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e MCF5272 with 16 MB Flash, 25 MHz, 16 MB DRAM (on CPM810)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Profibus DP (via CPM810), Modbus (standalone mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e +24 VDC ±5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Current (no field I\/O):\u003c\/strong\u003e 210 mA typical, 300 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption (no field I\/O):\u003c\/strong\u003e 6.0 W typical, 7.2 W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Inputs:\u003c\/strong\u003e 2 channels (active or passive probes), 0–12,000 Hz, 0.1 Hz accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Inputs (LV1-6):\u003c\/strong\u003e Up to 48 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Voltage Inputs (HV1-2):\u003c\/strong\u003e Up to 150 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs (DI1-2):\u003c\/strong\u003e Up to 220 VAC\/VDC (generator breaker, turbine reset)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs (DI3-5):\u003c\/strong\u003e 24\/48 VDC (miscellaneous trip functions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Inputs (AI1-2):\u003c\/strong\u003e 4–20 mA or 1–5 V (generator MW, intermediate steam pressure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Driver Outputs (DO1-6):\u003c\/strong\u003e 6 independent relay driver outputs, configurable matrix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (Overspeed Trip):\u003c\/strong\u003e \u0026lt; 8 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (Trip Anticipation \/ Load Drop):\u003c\/strong\u003e \u0026lt; 18 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e IEC\/EN 61508 SIL3 certified by TÜV Rheinland (for 2oo3 redundancy, de-energized to trip, periodic overspeed test)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail via TBU810 Terminal Base Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 119 × 106 × 44 mm (L×H×W) — per supplier data\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.16 kg — per supplier data\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTP800 System Architecture\u003c\/h3\u003e\n\u003cp\u003eThe TP800 Turbine Protection Module is comprised of three basic components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPM810\u003c\/strong\u003e — Common Processor Module: executes software algorithms and handles Profibus communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPM810\u003c\/strong\u003e — Turbine Protection Module (this module): conditions and digitizes field I\/O signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTBU810\u003c\/strong\u003e — Terminal Base Unit: houses CPM810 and TPM810, provides field I\/O and Profibus terminations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional expansion modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eROM810v2\u003c\/strong\u003e — Relay Output Module: 2 relays per module (2-Form C), 3 A @ 150 VDC \/ 5 A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eROM830\u003c\/strong\u003e — 2oo3 Voter Module: electronic voting for redundant trip solenoids\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCM810\u003c\/strong\u003e — Phase Current Module: interfaces to generator CTs for power load unbalance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEIM810\u003c\/strong\u003e — Extended I\/O Module: additional hardwired I\/O for standalone applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIM810\u003c\/strong\u003e — Serial Interface Module: firmware upgrade and standalone configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine overspeed protection\u003c\/li\u003e\n\u003cli\u003eGas turbine protection systems\u003c\/li\u003e\n\u003cli\u003eHydro turbine safety systems\u003c\/li\u003e\n\u003cli\u003eLoad drop anticipation (LDA)\u003c\/li\u003e\n\u003cli\u003ePower load unbalance (PLU) protection\u003c\/li\u003e\n\u003cli\u003eTrip anticipation and acceleration protection\u003c\/li\u003e\n\u003cli\u003eStandalone or DCS-integrated turbine protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can TPM810 operate standalone without a DCS?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when paired with CPM810 in the TBU810, the TP800 can operate in standalone mode using the SIM810 serial interface module for configuration via Turbine Automation Power Tools software. Profibus is not required in standalone mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What redundancy schemes does TP800 support?\u003c\/strong\u003e\u003cbr\u003eA: TP800 supports 1oo2, 2oo3 (TMR), and other common protection schemes. For SIL3 certification, a 2oo3 configuration with independent power supplies, de-energized-to-trip logic, and periodic overspeed testing is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between TPM810 and VPM810?\u003c\/strong\u003e\u003cbr\u003eA: TPM810 is the Turbine Protection Module for TP800. VPM810 is the Valve Positioning Module for VP800. Both use the same CPM810 processor and TBU810 base but have different analog I\/O circuitry for their respective functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is TPM810 compatible with non-ABB DCS systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the TP800 system can integrate with any Profibus DP-capable DCS platform via the onboard Profibus interface, or operate completely standalone with hardwired I\/O.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TBU810 Terminal Base Unit on standard 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eInstall the CPM810 Common Processor Module into the left slot of the TBU810.\u003c\/li\u003e\n\u003cli\u003eInstall the TPM810 Turbine Protection Module into the right slot of the TBU810.\u003c\/li\u003e\n\u003cli\u003eConnect +24 VDC power supply to the TBU810 power terminals.\u003c\/li\u003e\n\u003cli\u003eWire speed probe inputs (active or passive) to the designated speed input terminals.\u003c\/li\u003e\n\u003cli\u003eWire digital inputs (generator breaker, turbine reset, trip functions) per the application wiring diagram.\u003c\/li\u003e\n\u003cli\u003eWire analog inputs (generator MW, steam pressure) if power load unbalance or trip anticipation is enabled.\u003c\/li\u003e\n\u003cli\u003eConnect Profibus DP cable to the TBU810 Profibus port for DCS integration (optional for standalone).\u003c\/li\u003e\n\u003cli\u003eAttach ROM810v2 Relay Output Modules as needed for trip solenoid driving.\u003c\/li\u003e\n\u003cli\u003eConfigure protection parameters via Profibus (DCS mode) or SIM810 serial interface (standalone mode).\u003c\/li\u003e\n\u003cli\u003ePerform overspeed test to verify proper operation of protection functions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53844419281080,"sku":"TPM810","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TPM810_2.png?v=1785480399","url":"https:\/\/www.globalpetroparts.com\/products\/abb-tpm810-800-series-turbine-protection-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}